• Title/Summary/Keyword: 충진

Search Result 1,588, Processing Time 0.028 seconds

Dynamic Adsorptive Characteristics of Dual Adsorbents Bed Packed with Activated Carbon and Zeolite 13X for Benzene Adsorption (활성탄 및 제올라이트 13X를 충진한 이중흡착층 내에서 벤젠의 동적흡착 특성)

  • Kang, Sung-Won;Suh, Sung-Sup;Min, Byung-Hoon
    • Clean Technology
    • /
    • v.10 no.3
    • /
    • pp.159-168
    • /
    • 2004
  • Benzene adsorption experiment was carried out for activated carbon and zeolite 13X adsorbents. Single column and dual column packed with two adsorbents were used to investigate the dynamic adsorptive characteristics. Effect of feed flow rate on the breakthrough curve was not significant. Specific adsorption amount of benzene for activated carbon was larger than that for zeolite 13X. On the contrary, adsorption amount per column volume was larger for zeolite 13X column because the density of zeolite 13X was larger. In the dynamic experiment using dual adsorbents column, length of mass transfer zone was changed by the feed direction. Breakthrough time was longer and breakthrough curve was sharper when activated carbon was packed in feed inlet and zeolite 13X was packed in column outlet. Also breakthrough time and breakthrough curve slope were affected by the packing ratio of the two adsorbents.

  • PDF

The study on the properties of binary mixture(crystalline silica/AIN) filled EMC(Epoxy Molding Compounds) (결정성 실리카/질화 알루미늄 혼합충진에 따른 EMC의 물성 연구)

  • 김원호;홍용우;배종우;황영훈;김부웅
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.4
    • /
    • pp.41-48
    • /
    • 1999
  • Silica is the most popular materials as a filler of EMC for microelectronic packaging. However, because of its low thermal conductivity, the use of silica is restricted to parts requiring high thermal dissipation. The superior fluidity of EMC can be achieved with a combination of filler size distribution. In this study, physical properties of EMC filled with the crystalline silica(13$\mu\textrm{m}$) which have high fluidity and low cost and the AlN(2 $\mu\textrm{m}$) which have high thermal conductivity and low coefficient of thermal expansion were evaluated by changing the AlN/silica ratios. As a result of the evaluation of physical properties of EMC, the optimum mixing ratio of AlN/crystalline silica was 0.3/0.7. In this condition, binary mixture(AlN/crystalline silica) filled EMC showed superior properties, i.e., in the thermal conductivity, CTE, dielectric constant, flexural strength, and thermal shock resistance without reduction of fluidity.

  • PDF

Study on the Ozone Generation and Decomposition of Trichloroethylene Using Dielectric Ball Materials filled Barrier Discharge (유전체 볼 충진 배리어 방전을 이용한 오존 생성 및 TCE 분해처리에 관한 연구)

  • Han, Sang-Bo
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.431-437
    • /
    • 2019
  • This work was carried out ozone generation and TCE decomposition characteristics using dielectric ball materials filled barrier discharge reactor and catalyst's reactor for ozone decomposition. Ozone concentration generated from $Al_2O_3$ or $TiO_2$ filled barrier discharge reactor was so high compared with non-filled discharge reactor. This reactor is good discharge structure for generating the high ozone concentration. In addition, TCE decomposition rate and COx conversion rate increased using $MnO_2$ filled discharge reactor, because ozone was decomposed at the same discharge space on the surface of $MnO_2$ catalysts. To identify the $MnO_2$ catalytic effects, TCE decomposition rate reached to 100[%] by the decomposition of ozone at $MnO_2$ catalyst's reactor by the arrangement of $Al_2O_3$ filled discharge reactor and $MnO_2$ catalyst reactor. Finally, $MnO_2$ catalyst is good materials for the decomposition of ozone and this process will be useful for decomposing VOCs such as TCE.

Minimized Priming Volume for Open Heart Surgery in Neonates and Infants (신생아와 유아 심장 수술 시 심폐기회로 충진액의 최소화)

  • Kim, Woong-Han;Chang, Hyoung-Woo;Yang, Sung-Won;Cho, Jae-Hee;Lee, Kyung-Hoon;Baek, In-Hyuk;Kwak, Jae-Gun;Park, Chun-Soo;Lee, Jeong-Ryul;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.418-425
    • /
    • 2009
  • Background: Cardiopulmonary bypass (CPB) involves use of an initial priming volume which can cause side effects such as hemodilution, transfusion, inflammatory reaction and edema. Hence, there have been efforts made tore-duce the initial priming volume. We compared this traditional method to a CPB method that uses a minimized priming volume (MPV). Material and Method: For 97 patients who underwent congenital cardiac surgery between July 2007 to June 2008, we discussed each case and decided which method to use. We reviewed the medical records and cardiopulmonary bypass sheets of the patients. Result: We used a MPV method for 46 patients, and a traditional method for the other 51. There were no significant differences in preoperative and intraoperative characteristics between the two groups, such as body weight, age, cardiopulmonary bypass time, lowest body temperature, etc. However, the priming volume was much smaller in the MPV group than the traditional group (p<0.001). The volume of initially mixed packed RBC was also much smaller in the MPV group (p<0.001). There were no significant differences in postoperative mortality and neurologic complications. Conclusion: We could significantly reduce the initial priming volume and initially mixed pRBC volume with the revised CPB method. We suggest that this method be used more widely for congenital cardiac surgery.

Effect of Non-Conducting Filler Additions on Anisotropic Conductive Adhesives(ACAs) Properties and the Reliability of ACAs Flip Chip on Organic Substrates (이방성 전도 접착제 물성과 유기 기판 플립 칩의 신뢰성에 미치는 비전도성 충진재의 영향)

  • Im, Myeong-Jin;Baek, Gyeong-Uk
    • Korean Journal of Materials Research
    • /
    • v.10 no.3
    • /
    • pp.184-190
    • /
    • 2000
  • We investigated the effect of filler content on the thermo-mechanical properties of modified ACA composite materials by incorporation of non-conducting fillers and the reliability of flip chip assembly on organic substrates using modified ACA composite materials. For the characterization of modified ACA s composites with different content of non-conducting fillers, differential scanning calorimeter (DSC), and thermo-gravimetric analyzer (TGA), dynamic mechanical analyzer (DMA), and thermo-mechnical analyzer (TMA) were utilized. As the non-conducting filler content increased, CTE values decreased and storage modulus at room temperature increased. In addition, the increase in the content of filler brought about the increase of Tg^{DSC}$ and $Tg^{TMA}$. However, the TGA behaviors stayed almost the same. Contact resistance changes were measured during reliability tests such as thermal cycling, high humidity and temperature, and high temperature at dry condition. It was observed that reliability results were significantly affected by CTEs of ACA materials especially at the thermal cycling test. Results showed that flip chip assembly using modified ACA composites with lower CTEs and higher modulus by loading non-conducting fillers exhibited better contact resistance behavior than conventional ACAs without non-conducting fillers.

  • PDF

일산화탄소 제거를 위한 정화통용 첨착금속화합물 촉매의 특성

  • 박재만;김덕기;신채호;신창섭
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.11a
    • /
    • pp.301-304
    • /
    • 2002
  • 화재대피용 방독마스크의 주요한 기능은 상온에서의 일산화탄소 제거이며, 가장 효과적인 방법은 촉매에 의한 것이다. 일산화탄소 제거를 위한 호흡용 보호구의 정화통 충진재로써 범용으로 쓰이는 촉매는 Hopcalite로 Cu와 Mn이 혼합된 산화물 촉매이다. 그러나 이들 촉매는 상온에서 CO의 제거효율이 낮아 많은 양을 충진해야 하는 어려움이있다.(중략)

  • PDF

Feasibility Study of Applying EMMC Process to Recirculation Water Treatment System in High Density Seawater Aquaculture Farm through Laboratory Scale Reactor Operation (실험실규모 반응조 운전을 통한 고밀도 해산어 양식장 순환수 처리공정으로서 EMMC공정의 적용 가능성 연구)

  • Jeong Byung Gon;Kim Byung Hyo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.3
    • /
    • pp.116-121
    • /
    • 2004
  • Treatability tests were conducted to study the feasibility of EMMC process as a recycling-water treatment system in high density seawater aquaculture farm. To study the effect of organic and ammonia nitrogen loading rate on system performance, hydraulic retention time was reduced gradually from 12hr to 10min. The conclusions are can be summarized as follows. When the system HRT was reduced from 12hr to 2hr gradually, there was little noticeable change(reduction) in ammonia nitrogen removal efficiencies. However, removal efficiencies were decreased dramatically when the system was operated under the HRT of less than 2hr. In case of organics(COD), there was no dramatic change in removal efficiencies depending on HRT reduction. COD removal efficiencies were maintained successfully higher than 9% when the system was operated at tile HRT of 10 min. System performances depending on media packing ratio in the reactors were also evaluated. There were little differences in each reactor performances depending on media packing ratio in reactor when the reactors were operated under the HRT of longer than 1hr. However, differences in reactor performances were considerably evident when the reactors were operated under the HRT of shorter than 1hr. When comparing reactor performance among 25%, 50%,7 5% packed reactor, it can be judged that media packing ratio more than 50% plays no significant role in increasing reactor performance. For this reason, packing the media less than 50% is more reasonable way in view of economic. Such a tendency shown in COD removal efficiencies well agreed with the variation of ammonia-nitrogen removal efficiencies according to the media packing ratio in reactors at each HRT. Difference in effluent ammonia-nitrogen concentration between 50% media packing reactor and 75% media packing reactor was negligible. When comparing with the results of 25% packing reactor, difference was not so great.

  • PDF

Study on the Development of Simultaneous Analytical Method for the Residual Organic Chloride Pesticides by Gas Chromatography (기체 크로마토그래피를 이용한 유기 염소계 잔류 농약 동시 분석 방법 개발에 관한 연구)

  • Kim, Woo-Seong;Lee, Bong-Hun;Park, Heung-Jai
    • Journal of Environmental Science International
    • /
    • v.5 no.5
    • /
    • pp.561-567
    • /
    • 1996
  • A method for the simultaneous analysis of 31 residual organic chloride pesticides was studied using gas chromatography. Prepared analytical samples were injected to gas chromatography (HP 5890 Series II plus) on the Ultra-2 column with ECD. The packing materials for column were changed as the following reagents ; florisil and alumina N, The residual solution was loaded to column and was elected pith erection solvents ; ether : benzene (2 : 8) solution, hexane : benzene (1 : 1) solution, dichloromethane, acetone, and methanol. The analytical results showed that 6 kinds of organic chlorides were not detected when florisil (first condition) was used as the column packing material. The nondetected 6 kinds of organic chlorides in the first analytical condition were detected and the recoveries of thrin-pesticides were increased, in particular, captan and captafol, but the recoveries of benzene hexachloride compounds were decreased when dichloromethane and methanol were added as elution solvents (pac'king material was florisil as in the first condition). The recoveries of dichlornuanid, chlorofenvinfos, folpet, and dicofol were increased and that of aldrin was increased, but those of captan and captafol were not good when alumina N was used as the packing material. To detect simultaneously thrin-pesticides, captan, and captafol, florisil and alumina N were used as the packing materials. The elution result showed that captan and captafol were not detected. This was because the column was activated insufficiently. The analytical method was the best (31 kinds of organic chlorides in the residual pesticides were detected sharply and showed high sensitivity) when the column (packing materials were florisil and alumina N: together) was fuliy activated and the impurities were removed using various elution solvents.

  • PDF

A Study on the Forming Technology of Multi-stage Aircell Filling Valves (다단 에어셀 충진 밸브성형기술에 관한 연구)

  • Kim, Mi-Suk;Park, Dong-Sam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.57-64
    • /
    • 2017
  • Today, due to the environmental regulations regarding air pollution in the EU, the use of EPS (Styrofoam) as the cushioning material in the packaging industry is decreasing. In effect, air cushioning based cushioning materials are rapidly expanding into the market and replacing EPS, due to their excellent buffering ability and environmental friendliness. This is a new selective filling type air filling material manufacturing technology that affords improvements in the amount of raw materials required, its processing and its aesthetic appearance compared to the conventional air filling cushioning materials. In this study, a multi-stage air cell filling valve molding technology is developed based on selective filling technology, which allows packages to be selectively filled in various forms by applying valve forming structure technology. This multi-stage air cell filling valve molding technology is a technique in which a plurality of injection ports are formed by laminating three layers of films, viz. a first injection film, a valve film, and a second injection film having valve ends. In the conventional technology, a separate external air injection path for injecting air into a plurality of connected air bags is needed. However, in the proposed system, an external air injection path is formed inside the air bag, Due to the lack of need for an injection furnace, the raw material and process are reduced and air is injected and then discharged, while the air bag is reduced in length to 63 ~ 66% of its normal value. The outer surface of the outer air injection path is integrated inside by maintaining the original length of the cross section, while the unnecessary folded air is injected into the interior of the air bag, This smart air filling type cushioning material manufacturing technology constitutes a big improvement over the existing technologies.

A Study on Bond Strength of Cement-Based Filler and Flexural Strength of RC Beam Strengthened with GFRP by Filler Thickness (시멘트계 충진제의 접착 성능 및 보강 두께에 따른 GFRP 보강 RC보의 휨 성능에 대한 연구)

  • Choi, Ha-Jin;Choi, Young-Woong;Park, Jong-Chul;Jung, Si-Young;Choi, Oan-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.144-152
    • /
    • 2010
  • In this study, cement-based filler is used as an adhesive instead of organic adhesive, epoxy because there were problems under wet condition. First, the bond strength of cement-based filler was measured and the result was satisfied with KS F 4716. However, in case of wet condition, bond strength of epoxy adhesive decreased $0.73N/mm^2$ in 7 days and $0.84N/mm^2$ in 14 days from pilot test. This implies that there would be a problem on reinforced concrete structure in wet condition, such as tunnel and sewage box. In the second experiment, the flexural strength of RC beams with GFRP using different thickness of cement-based filler was investigated, and the result was indicated 113%, 66%, 75% increase in 10mm, 20mm, 30mm thickness, respectively. From the result, it was known that 10mm filler thickness produces stable bond performance.