Development of a rapid HPLC method for the determination of penciclovir in human plasma using a monolithic column and its application to a bioequivalence study (모노리틱 칼럼을 이용한 혈장 중 펜시를로버의 HPLC 신속분석법 개발 및 이를 이용한 생물학적동등성시험)

  • Kim, Jin Hee;Park, Ah Yeon;Jung, Eun Ha;Lee, Cheol Woo;Lee, Tae Ho;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.323-330
    • /
    • 2007
  • A simple and rapid HPLC method with fluorescence detection(FLD) for quantitation of penciclovir in human plasma using a monolithic column was developed and validated. Penciclovir and ganciclovir(internal standard, I.S.) were separated on a Chromolith column RP-18e ($4.6{\times}100mm$) with a mobile phase consisting of a mixture of (A) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (3/97, pH 2.5) and (B) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (50/50, pH 2.5) at a flow gradient of $1.6{\sim}4.0mL/min$. The retention times of penciclovir and internal standard were less than 4.0 min. Calibration curve was linear ($R^2=0.9994$) over a concentration range of $0.1{\sim}5{\mu}g/mL$. Intra-day precision, accuracy and inter-day precision were 1.36~8.55 %, 92.8~100.0 % and 0.93~5.62 %, respectively with a limit of quantitation at $0.1{\mu}g/mL$. The present HPLC-FLD method is sensitive, precise and accurate. The method described herein has been successfully used for the bioequivalence study of a famciclovir formulation product after oral administration to healthy Korean volunteers.

Field Applicability Evaluation Experiment for Ultra-high Strength (130MPa) Concrete (초고강도(130MPa) 콘크리트의 현장적용성 평가에 관한 실험)

  • Choonhwan Cho
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.20-31
    • /
    • 2024
  • Purpose: Research and development of high-strength concrete enables high-rise buildings and reduces the self-weight of the structure by reducing the cross-section, thereby reducing the thickness of beams and slabs to build more floors. A large effective space can be secured and the amount of reinforcement and concrete used to designate the base surface can be reduced. Method: In terms of field construction and quality, the effect of reducing the occurrence of drying shrinkage can be confirmed by studying the combination of low water bonding ratio and minimizing bleeding on the concrete surface. Result: The ease of site construction was confirmed due to the high self-charging property due to the increased fluidity by using high-performance water reducing agents, and the advantage of shortening the time to remove the formwork by expressing the early strength of concrete was confirmed. These experimental results show that the field application of ultra-high-strength concrete with a design standard strength of 100 MPa or higher can be expanded in high-rise buildings. Through this study, we experimented and evaluated whether ultra-high-strength concrete with a strength of 130 MPa or higher, considering the applicability of high-rise buildings with more than 120 floors in Korea, could be applied in the field. Conclusion: This study found the optimal mixing ratio studied by various methods of indoor basic experiments to confirm the applicability of ultra-high strength, produced 130MPa ultra-high strength concrete at a ready-mixed concrete factory similar to the real size, and tested the applicability of concrete to the fluidity and strength expression and hydration heat.

A STUDY ON MICROLEAKAGE OF SEALED AMALGAM RESTORATION (Sealed amalgam restoration의 미세누출에 관한 연구)

  • Lee, Sang-Heon;Lee, Jae-Cheoun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.54-61
    • /
    • 2000
  • Amalgam, though a widely used dental material, does not bond to the tooth substrate Therefore, retentive preparation of the cavity is necessary. Such amalgam restorations, until corrosion products form and plug the margin, will show significant marginal leakage. Unless this is prevented early on, saliva and bacteria may enter the cavity causing postoperative hypersensitivity, dissolution and collapse of the restoration, discoloration of the margin and secondary caries, leading to shortened life-span of the restoration and pulpal pathosis. Recently, a method of restoration has been introduced whereby tooth material can be preserved, cavity margin can be sealed and preventive treatment of pit and fissure can be administered while retaining all the advantages of conventional amalgam restorations. Such sealed amalgams involve removing the carious lesion without extending the cavity for prevention and using pit and fissure sealants to seal cavity margins and pit and fissures to reduce microleakage. In this study, finishing of the amalgam and sealant application were performed after different intervals following of amalgam restoration to compare the microleakage of sealed and conventional amalgam restorations. Thirty bicuspids were prepared with Class V cavity preparations on the buccal and lingual surfaces. After amalgam placement, they were divided into the following groups and treated accordingly. Group 1 : Polishing after 24 hours Group 2 : Immediate sealant application without polishing Group 3 : No polishing, but sealant applied after thermocycling 500 times After treatment, the samples were thermocycled 500 times between $5^{\circ}C$ and $55^{\circ}C$ with a dwell time of 30 seconds. After thermocycling, the samples were dipped into 1% methylene blue kept in a $37^{\circ}C$ incubator at 100% humidity for 24 hours. The teeth were then embedded in resin and cut bucco-lingually along the tooth axis and observed with a stereomicroscope to determine the degree of microleakage, The following results were obtained : 1. Group 2 showed the least microleakeage, while group 1 showed the greatest. 2. Group 1 showed significantly greater microleakage compared to group 2 (p<0.05). However, no significant differences were found between group 1 and 3(p>0.05). No significant differences in microleakage were also found between cup 2 and 3(p<0.05).

  • PDF

Precessing of Smoked Dried and Powdered, Sardine for Instant Soup (정어리 분말수우프의 가공)

  • Oh, Kwang-Soo;Chung, Bu-Kil;Kim, Myung-Chan;Sung, Nak-Ju;Lee, Eung-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.17 no.2
    • /
    • pp.149-157
    • /
    • 1988
  • This study was carried out to prepare the flavoring substance using sardine for instant soup, and to examine the taste compounds and storage stability of the product. In preparation of product, raw sardine are gutted, boiled for 10 minutes and smoked 3 times to $9{\sim}10%$ moisture content at $80^{\circ}C$ for 8 hours. The smoked-dried sardine meat were followed to be 50 mesh of particle size. The powdered-dried sardine were mixed 4.0% sugar, 20.0% table salt, 3.0% monosodium glutamate, 0.2% black pepper, 0.2% garlic powder and 0.2% onion powder, Finally the powdered instant soup product were vacuum packed in a laminated film(PET/A1 foil/CPP) bag, and then stored at room temperature for 120 days. The effect of smoking on enhancing flavor and on preventing lipid oxidation of product during storage were observed. From the chemical analysis and omission test, the principal taste compounds of product were IMP, 478.2mg/l00g; free amino acids such as glutamic acid, histidine, arginine, phenylalaine 3292.5mg/l00g; non-volatile organic acids such as lactic acid, ${\alpha}-ketoglutaric$ acid, 712.2mg/l00g; total creatinine 409.0mg/100g, and small amount of betaine, TMAO. Fatty acid composition of product were mainly consisted of polyenoic acids such as 20:5, 22:6, followed by saturated acids, monoenoic acid. The major fatty acid were 16:0, 16:1, 18:1, 20:5 and 22:6. From the results of sensory evaluation and chemical experiments during storage, the vacuum packed product were good condition for preserving the quality during storage for 120 days. We may conclude that the quality of present product was not inferior to that of seasoning powder of anchovy on the market, and it can be commercialized as a flavoring substance in preparing soup and broth.

  • PDF

A STUDY ON THE MICROLEAKAGE OF DENTIN BONDING SYSTEMS (상아질 접착제의 미세누출에 관한 연구)

  • Son, Jeong-Min;Choi, Nam-Ki;Kim, Seon-Mi;Yang, Kyu-Ho;Park, Yang, Ji-il
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.4
    • /
    • pp.619-627
    • /
    • 2008
  • The objective of this study was to compare the microleakage of five adhesive systems in the enamel and dentin of permanent teeth. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of 25 extracted human molar teeth. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM), Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL) and G-Bond (GB). The results were as follows: 1. At the enamel margins, PL showed the highest leakage value(0.85), and others showed values of SB(0.55), GB(0.50), SM(0.35) and SE(0.25) in decreasing order. There were statistically significant differences in PL vs. SM and PL vs. SE(p<0.05). 2. At the dentin margins, GB showed the highest leakage value(2.10), and others showed values of SE(1.45), PL(1.40), SB(1.05), SM(0.70) in decreasing order. There were statistically significant differences in GB vs. SB and GB vs. SM(p<0.05). 3. Dentin margins showed high dye penetration rate than enamel margins in all material tested groups and there were statistically significant differences for SE, PL and GB.

  • PDF

THERMAL CHANGE AND MICROHARDNESS IN CURING COMPOSITE RESIN ACCORDING TO VARIOUS CURING LIGHT SYSTEM (광중합기에 따른 복합레진 중합시 온도 변화와 미세경도에 관한 연구)

  • Lee, Dong-Jin;Kim, Dae-Eop;Yang, Yong-Sook;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.391-399
    • /
    • 2004
  • The purpose of this study was to compare curing efficiency of newly developed curing units to traditional halogen curing unit by measuring thermal change and surface microhardness according to curing light system. Materials and mathods : The types of curing units were traditional low intensity halogen light(Optilux 360), plasma arc light(Flipo), low heat plasma arc light(Aurys), low intensity LED(Starlight), and high intensity LED(Freelight2). Temperature at the tip of light guide was measured by a digital thermometer using K-type thermocouple. And after resin was filled to 2, 3, 4mm teflon mold, bottom temperature measured during curing. After 24 hours, microhardness of top surface and bottom surface of each resin specimen were measured. Results : The result of this study can be summarized as follows, 1. As measuring temperature of curing unit tips, Flipo is the highest as $52.4^{\circ}C,\;Freelight2(37.86^{\circ}C),\;Optilux360(32.68^{\circ}C),\;Aurys(32.34^{\circ}C),\;and\;Starlight(26.14^{\circ}C)$ were followed. 2. Flipo and Freelight2 were the highest similarly and Optilux360 and Aurys were similarly next and Starlight was lowest in temperature of bottom surface of resin mold. 3. Microhardness of top surface were generally similar, and Aurys was relatively low. 4. Optilux 360 and Freelight2 were the highest, and Flipo, Starlight, and Aurys were followed in microhardness of bottom surface. Conclusions : The results suggest that careful use of Flipo and Freelight2 might be able to cure greater depth of resin composite and do not cause thermal problems than other curing units.

  • PDF

HARDNESS OF COMPOSITE RESIN CURED BY HIGH INTENSITY HALOGEN LIGHT (고강도 할로겐광으로 중합한 복합레진 수복재의 경도)

  • Park, Jong-Seok;Lee, Kwang-Hee;Kim, Dae-Eup;Kim, Seong-Hyeong;Ahn, Ho-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.471-479
    • /
    • 2001
  • The purpose of this study was to compare the effect of the high intensity halogen light $(850\sim1000mW/cm^2)$ with that of the conventional halogen light $(400mW/cm^2)$ on the hardness of composite resin. Three resin composites (Z-100, 3M, U.S.A. : Tetric Ceram, Vivadent, Liechtenstein; SureFil, Dentsply, U.S.A.) were filed in the stainless steel moulds which were 4mm in diameter and 2, 3, 4, and 5mm in depth, respectively. They were cured under the four different modes : (1) conventional mode, 40 seconds at $400mW/cm^2$; (2) 'ramp' mode, 10 seconds at 100 to $1000mW/cm^2$ plus 10 seconds at $1000mW/cm^2$; (3) 'boost' mode, 10 seconds at $1000mW/cm^2$; and (4) 'standard' mode, 20 seconds at $850mW/cm^2$. The surface hardnesses of the top and the bottom of the resin samples were measured with a microhardness tester (MXT70, Matsuzawa, Japan). The top surface hardness was not significantly different among the curing modes. The bottom surface hardness was generally the highest in the conventional mode and the lowest in the high intensity boost mode. There was no significant difference in the bottom surface hardness between the conventional mode and the high intensity standard mode in 2mm depth. The results suggest that the curing time of the high intensity halogen light $(850mW/cm^2)$ should be at least 20 seconds to produce the equal level of the bottom surface hardness of 2mm resin composite as compared to the hardness produced by the conventional halogen light $(400mW/cm^2)$.

  • PDF

Preparation and Keeping Quality of Vacuum Packed Seasoned-Dried Sardine (진공포장 정어리 조미건제품의 제조 및 품질안정성)

  • LEE Eung-Ho;KIM Jin-Soo;KIM Han-Ho;LEE Jin-Kyung;OH Kwang-Soo;KWON Chil-Sung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.1
    • /
    • pp.52-59
    • /
    • 1986
  • As one of trials to process instant sardine foods which can be preserved at room temperature, three kinds of products were prepared as seasoned-dried product (control, C), liquid smoked seasoned-dried product(S) and antioxidant treated seasoned-dried product(E), and their processing conditions and quality stability during storage were examined. Raw sardines were dressed, steamed and then filleted. The sardine fillets were seasoned with the mixed seasoning solution containing $28.0\%$ of sorbitol, $14.0%$ of sugar, $5.6\%$ of table salt, $1.8\%$ of monosodium glutamate, $0.6\%$ of garlic powder and $50.0\%$ of water at $5^{\circ}C$ for 15 hours, and dipped for 45 seconds in $10\%$ Smoke-EZ solution. After liquid smoking, the seasoned and liquid smoked sardine fillets were dried at $45^{\circ}C$ for 4 hours, vacuum packed in laminated plastic film bag(polyester/casted polypropylene= $12{\mu}m/70{\mu}m,\;15{\times}16cm$), and finally pasteurized in water at $95^{\circ}C$ for 30 minutes. The results obtained from chemical and microbial experiments during storage are as follows : the moisture contents, water activity and pH of the products showed little change, and VBN of them slightly increased during storage. The TBA value and POV of the products (E, S) were lower than those of control product(C) considerably. In color values, L value (linghtness) decreased while a and b value (red and yellow) revealed a tendency to increase during storage. The fatty acid composition of the products were similar to those of raw sardine, the predominant fatty acids were 16:0, 20:5, 18:1 and 22:6. The products (E, S) have a good preservative effect on highly unsturated fatty acids during storage. Viable cell counts of those products were negative and histamine contents were less than 2.0 mg/100 g. Among the texture profiles, hardness, elasticity and cohesiveness of the products slightly decreased during storage. Judging from the sensory evaluations, liquid smoked seasoned-dried product(S) was the most desirable, and the products could be preserved in good condition for 40 days at $25{\pm}3^{\circ}C$.

  • PDF

EFFECT OF INTERMITTENT POLYMERIZATION ON THE RATE OF POLYMERIZATION SHRINKAGE AND CUSPAL DEFLECTION IN COMPOSITE RESIN (복합 레진의 간헐적 광중합 방법이 중합 수축 속도와 치아의 교두 변위에 미치는 영향)

  • Kim, Min-Kyung;Park, Sung-Ho;Seo, Deog-Gyu;Song, Yun-Jung;Lee, Yoon;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.341-351
    • /
    • 2008
  • This study investigated the effect of intermittent polymerization on the rate of polymerization shrinkage and cuspal deflection in composite resins. The linear polymerization shrinkage of each composite was measured using the custom-made linometer along with the light shutter specially devised to block the light at the previously determined interval. Samples were divided into 4 groups by light curing method; Group 1) continuous light (60s with light on); Group 2) intermittent light (cycles of 3s with 2s light on & 1s with light off for 90s): Group 3) intermittent light (cycles of 2s with 1s light on & 1s with light off for 120s); Group 4) intermittent light (cycles of 3s with 1s light on & 2s with light off for 180s). The amount of linear polymerization shrinkage was measured and its maximum rate (Rmax) and peak time (PT) in the first 15 seconds were calculated. For the measurement of cuspal deflection of teeth, MOD cavities were prepared in 10 extracted maxillary premolars. Reduction in the intercuspal distance was measured by the custom-made cuspal deflection measuring machine. ANOVA analysis was used for the comparison of the light curing groups and t-test was used to determine significant difference between the composite resins. Pyramid showed the greater amount of polymerization shrinkage than Heliomolar (p < 0.05). There was no significant difference in the linear polymerization shrinkage among the groups. The Rmax was group 4 < 3, 2 < 1 in Heliomolar and group 3 < 4 < 2, 1 in Pyramid (p < 0.05). Pyramid demonstrated greater cuspal deflection than Heliomolar. The cuspal deflection in Heliomolar was group 4 < 3 < 2, 1 and group 4, 3 < 2, 1 in Pyramid (p < 0.05). It was concluded that the reduced rate of polymerization shrinkage by intermittent polymerization can help to decrease the cuspal deflection.

Evaluation of the Removal Characteristics of Pollutants in Storm Runoff Depending on the Media Properties (여재 특성에 따른 강우 유출수 내 오염물질 제거특성 평가)

  • Kim, Tae-Gyun;Cho, Kang-Woo;Song, Kyung-Guen;Yoon, Min-Hyuk;Ahn, Kyu-Hong;Hong, Sung-Kwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.483-490
    • /
    • 2009
  • The aims of this study were to evaluate the removal efficiency for various pollutants in urban storm runoff by a filtration device, and to determine design parameters depending on filter media properties. Appropriate selection of filter media will affect the size and life time of the filtration device. Sets of column tests were performed in order to evaluate the removal efficiency by perlite and a synthetic resin. An investigation of surface properties including CEC (cation exchange capacity) and zeta-potential suggested that the perlite had a superior adsorption capability for cationic pollutants. TCODcr and turbidity were analyzed to investigate the removal characteristic of particulate pollutant. In both columns, the particles in the collected storm runoff was almost completely capture with a small EBCT (empty bed contact time) of 2.5 minutes. Complete clogging at the EBCT of 2.5 minutes occurred after 630 minutes in the perlite column and 810 minutes in the resin column. The removal efficiency of TCODcr and turbidity at the EBCT of 2.5 minutes decreased to below 70% due to an wall effect. The removal efficiency for dissolved pollutant (SCODcr) was negligible due to the insufficient contact time for adsorption. The removal of heavy metals (Cu, Zn, Pb) was mostly ascribed to the filtration of particles containing metals, since the relationship between CEC and the removal efficiency was not apparent. The result of this study would be valuable for the application of filtration device to control of urban storm runoff.