• Title/Summary/Keyword: 충적대수층

Search Result 91, Processing Time 0.059 seconds

A study on induced polarization characteristics of sand and clay for alluvium investigation (충적층 조사를 위한 모래와 점토의 유도분극 특성 고찰)

  • Choi, Sang-Hyuk;Kim, Hyoung-Soo;Kim, Ji-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.179-184
    • /
    • 2008
  • Silt or clay alluvium fully saturated with water generally shows low resistivity. Sometimes it is believe that the low resistivity layer is considered as good aquifer but this makes problems in the development of groundwater. To overcome this problem, we adopted induced-polarization(IP) method with resistivity method. Laboratory experiments and resistivity/IP field surveys with non-polarization electrodes were conducted for the study. Laboratory experiments shows that the increase of clay contents in the sample mixed with sand and clay give low resistivity and high chargeability. We used this experiment results in the interpretation of resistivity/IP field data which were obtained in riverbank filtration. Finally, the layer which has low resistivity and chargeabilty would be regarded as a good aquifer for the development of groundwater intake.

  • PDF

Determination of Aqnifer Characteristics from Specific Capacity Data of Wells in Cheju Island (제주도 지하수의 우물 비양수량자료를 이용한 대수층상수 결정방법)

  • 최병수
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.180-187
    • /
    • 1999
  • Transmissivity is often estimated from specific capacity data because of the expense of conducting standard aquifer test to obtain transmissivity and the relative availability of specific capacity data. Most often, analytic expression relating specific capacity to transmissivity derived by Theis (1963). Brown (1963). and Logan (1964) are used in this analysis. The analytic solution typically used to predict transmissivity from specific capacity in alluvial aquifers assuming influence radius and/or storage coefficient of the aquifers. But those do not agree well with the measured transmissivity in fractured rock aquifers and in heterogeneous aquifers. Razack-Huntely (199l). Huntely-Steffey (1992). and Mace (1997) proposed emphirical rotations between specific capacity and transmissivity in heterogeneous alluvial aquifers. fractured rock aquifers, and karst aquifers. This study focuses on comparison between transmissivity and specific capacity data in volcanic rock aquifers of Jeju Island. Emphirical relation between the log of transmissivity and the log of specific capacity suggests they no linearly related (correlation coefficient 0.951) and the width of $\pm$0.25 log cycles in transmissivity includes 96.6% of data.

  • PDF

Industry-University-Research Collaborative Geoscientific Study in Pocheon Area for Groundwater Survey, Part III : Resistivity Technology (포천지역 지하수기초조사 산학연 공동탐사 사례연구(III): 전기탐사기술)

  • You, Young-June;Kim, Jong-Nam;Yoo, In-Kol
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.129-136
    • /
    • 2005
  • The groundwater survey was carried out by electrical resistivity and resistivity tomography using several kinds of electrode array to delineate the depth of the saturated zone and basement complex, the aquifer system of fractured rock, and the 2-D resistivity structure was obtained by inversion technique. And the hole-to-surface and crosshole tomography were applied for two boreholes and the inverted resistivity tomogram are obtained. The comparison of those data with core logging data was performed and those results were relatively well correlated. And it was possible to find out the configuration of basement and the fracture zone and the aquifer system from the 2-D resistivity structure and resistivity tomogram.

  • PDF

연속 굴절파 중합 방식을 활용한 충적층 지하수위 조사기법 소개 및 현장 응용

  • 김형수;김중열;김유성
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.83-87
    • /
    • 2004
  • 본 연구는 고해상도의 충적층 지하수위 분포 조사를 위한 탄성파 굴절법 조사 방법을 소개하고 부여 군수리 충적층 일대에서 이 기법을 통해, 획득된 실제 충적층내의 지하수위 조사 결과를 제시한다. 기본적으로 본 연구에서 활용된 연속 굴절파 중합 방식은 동일 공심점(common mid point, 이후 CMP)을 갖는 굴절파 신호를 취합하고, 이격 거리(offset)에 대한 시간 지연 효과 보정을 수행한 후, 이들 신호를 중합하여, 충적층의 지하수위면에서 굴절된 신호를 보다 뚜렷이 부각시켜 정확한 지하수위 정보를 획득 하는 방식으로 일명 CMP 굴절법이라고도 한다. 이 방식은 독일에서 최초 개발되었으나(Gebrande, 1986; Orlowsky 등, 1998), 국내에서 적용되기는 본 연구가 최초이다. 이러한 탄성파의 굴절 신호를 사용하는 방식은 우선, 기존의 일반적인 고해상도 반사법 탐사에서 잡음으로 여겨졌던 굴절파 신호를 활용할 수 있으며, 고해상도 반사법 탐사와 동일한 배열과 운영 방식으로 획득된 자료에서 원하는 정보를 획득할 수 있으므로, 고해상도 반사법에 의한 기반암 조사와 함께 적용될 경우, 정화한 충적 대수층의 분포를 조사할 수 있게 하여주는 획기적인 조사 신기술이다. 개발된 기법은 부여 군수리 충적층 지역을 대상으로 적용되었으며, 그 결과 기존의 어떠한 지구물리 조사 방법보다 정확하고 분명한 지하수위 분포를 보여주었다.

  • PDF

Cooling Performance of Geothermal Heat Pump using Alluvium Aquifer (충적대수층을 이용한 지열히트펌프시스템의 냉방성능)

  • Kang, Byung-Chan;Park, Jun-Un;Lee, Chol-Woo;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.561-566
    • /
    • 2009
  • Alluvium is sedimentary stratum and composed of gravel, sand, silt, clay. Permeability of alluvium is the higher. If alluvium have lots of aquifer, will be of great use heat source and heat sink of heat pump. Alluvium aquifer contain the thermal energy of surrounding ground. Also geothermal heat pump using alluvium aquifer reduce expenses than general geothermal heat pump, because geothermal heat pump using alluvium aquifer make use of single well. In this study geothermal heat pump using alluvium aquifer was installed and tested for a building. The heat pump capacity is 30USRT. Temperature of ground water is in $12{\sim}17^{\circ}C$ annually and the quality of the water is as good as living water. The heat pump cooling COP is 4.4 ~ 4.7. The system cooling COP is 3.25 ~ 3.6. This performance is as good as BHE type ground source heat pump.

  • PDF

Using a Borehole Stability Device for Hydraulic Testing in Unconsolidated Alluvium (공벽 유지장치를 이용한 미고결 충적층의 수리특성 평가)

  • Won, Kyoung-Sik;Kim, Chunsoo;Chae, Soo-Yong;Shin, Dong-Min
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.15-22
    • /
    • 2016
  • Hydraulic falling head and slug tests were carried out in an alluvium aquifer using a borehole stability device. The hydraulic testing had proved difficult in alluvial formations of sands and gravels due to borehole collapse and unstable borehole walls within the test section. This study aims to improve the hydraulic test results by using a borehole stability device. The device can minimize the collapse of borehole walls, and the use of a filter with a constant opening ratio improves the calculations per unit area of the test section. Permeability obtained from the falling head test without a borehole stability device was 8.82 × 10−5m/sec. When the borehole stability device was installed in the same test section the measured permeability increased to 4.00 × 10−4m/sec, which is 4.5 times that obtained without the borehole device. The relatively low permeability obtained using the conventional test method is attributed to the presence of a fine-grained slime generated during drilling and a reduction of the test area in the test interval due to a gradual collapse of the borehole walls. This study considers how the use of a borehole stability device to prevent borehole collapse can influence the results of hydraulic tests in alluvial formations. It is expected that the results can be used as a basis for improving the reliability and applicability of hydraulic tests performed in alluvial aquifers.

울릉도 대수층 저장 및 회수기술의 현장 적용성 평가

  • Kim Man-Il;Seok Hui-Jun;Kim Hyeong-Su;Barry Jeffrey
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.415-419
    • /
    • 2005
  • 대수층 저장 및 회수(ASR)기술의 현장 적용성을 평가하기 위하여 경상북도 울릉군 울릉읍 저동천 상류부근에서 양수시험 및 주입시험을 실시하였다. 양수시험결과 투수계수는 $48.7m^2/day$ 이고, 저류계수는 0.009이며, 비양수량은 $158.2m^2/day$로 계산되었다. 또한 시험정과 관측정은 거의 위상차 없이 같은 수위강하 경향을 보여주며 취수정은 관측정보다 평균적으로 10cm 정도 더 높은 수위강하 폭을 보여주는 것으로 미루어 볼 때 시험정과 관측정의 두 지점은 서로 수리지질학적으로 긴밀히 연결되어 있는 하나의 시스템임을 강하게 시사한다. 이외에도 주입시험 결과 암반구간 대수층은 낮은 투수계수를 가질 뿐만 아니라 낮은 저류계수를 가지기 때문에 ASR에 불리한 조건을 가짐을 알 수 있다. 그러나 상부 충적층 구간에서 실시한 주입시험 결과, 두 지점은 긴밀히 연결된 하나의 시스템으로 두 지점의 심부 암반층과의 연결성은 없고, 대신 상부의 높은 투수계수를 가지는 충적층 구간이 두 지점사이에 서로 긴밀히 연결되어 있는 것으로 파악된다. 또한 잔류 수위가 0으로 떨어지는 것으로 볼 때 주입된 주입수는 저장되지 않고 인근의 저동천으로 빠져나가는 것으로 사료된다. 이상의 사실로 볼 때 본 연구지역은 ASR에 불리한 조건을 가지는 지역으로 최종적으로 판단된다.

  • PDF

Evaluation of Artificial Recharge Characteristics by using the Methods of Ditch and Injection well (Ditch상 인공주입방식을 이용한 인공함양 및 주입량 평가 연구)

  • Lee, Young Dong;Shin, Dong Min;Kim, Byeong Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.25-25
    • /
    • 2020
  • 최근 기후변화와 함께 한국은 매년 가뭄이 지속적으로 발생하고 있으며 피해지역도 다양하게 나타나고 있다. 이에, 가뭄에 능동적으로 대처하고, 지하수자원을 확보할 수 있는 인공함양 및 취수시설의 실증시설을 구축하여 상시 가뭄지역을 대상으로 적용하고자 한다. 최종적으로 연구지역의 소규모 평탄지 하천 중·상류지역 충적층에 인공함양을 통해 가뭄대책 마련을 위한 인공 주입시설을 설치하고, 대수층 발달이 양호한 하류지역에 수평집수정을 이용한 취수시설을 설치하여 취수-공급의 지속적인 순환방식의 통합적인 인공주입·취수시스템을 구축하고자 한다. 연구지역은 가뭄 및 상수도 미 보급지역으로 인해 제한급수가 이루어지고 있는 충청남도 홍성군 운곡리 지역을 대상으로 하였으며, 연구지역 주 대수층인 충적층은 시추조사 결과 지표하 0.5~12.3m에 분포하며, 실트질 모래 및 실트질 자갈로 구성되어있다. 대수층의 수리성은 양수 및 회복시험결과 3.79×10-4~7.71×10-3(평균 3.13×10-3)cm/sec로 인공함양을 위한 지반 특성으로 양호한 수리특성을 보인다. 본 연구에서는 연구지역의 지층분포 및 수리지질특성을 고려하여 현장시험 대수층에 인공함양 방법 중 Ditch 및 Ditch+injection Well을 설치하고 공경, 여재등 여러인자에 따른 인공 주입에 의한 함양특성과 수위변동 모니터링을 분석하였으며, 분석결과를 토대로 향후 최적의 취수시설을 구축하여 국내 상시 가뭄지역의 대체수자원확보와 용수공급 방안으로 활용할 수 있을 것으로 판단된다.

  • PDF

Evaluating groundwater-surface water interaction in riverside alluviums of the middle and low Nakdong River basin (낙동강 중.하류지역 하성충적층내의 지하수-지표수 연관성 평가)

  • Lee, Jeong-Hwan;Hamm, Se-Yeong;Cheong, Jae-Yeol;Kim, Gyoo-Bum;Ok, Soon-Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.179-183
    • /
    • 2010
  • 본 연구는 낙동강 중류 지역의 경북 구미시, 경북 왜관읍, 경북 성주군과 하류 지역의 경남 함안군, 창원시 북면과 대산면, 김해시 생림면의 하성충적층 내 지하수와 낙동강물의 연관성을 파악하였다. 중류와 하류지역에서 하성충적층의 주 대수층(모래자갈층)의 두께는 10m 내외로서 공간적으로 큰 차이를 보이지는 않는다. 하성충적층의 수리전도도는 $10^{-5}{\sim}10^{-3}$m/sec를 나타낸다. 하성충적층의 지하수위는 지역에 따라 해수면 기준으로 1.40~11.5m에서 변동하며, 지하수위와 낙동강 수위는 높은 상관성을 보인다. 지하수와 낙동강물의 화학분석 결과, 칼슘, 마그네슘, 나트륨, 칼륨, 염소, 규산, 중탄산, 망간, 철과 같은 무기성분의 농도는 지하수에서 더 높게 나타나고 있으나, 질산염의 농도는 낙동강물에서 더 높게 나타난다. 지하수내의 유기물질의 농도는 계절에 관계없이 비교적 일정하나, 낙동강물의 유기물질 농도는 우기보다 건기에 더 높은 경향성을 보이고 있다. 이러한 연구결과는 4대강 살리기 사업이나 하천주변지역의 수자원 개발에 활용될 수 있을 것이다.

  • PDF

Nitrate Contamination of Alluvial Groundwaters in the Keum River Watershed Area: Source and Behaviors of Nitrate, and Suggestion to Secure Water Supply (금강 권역 충적층 지하수의 질산염 오염: 질산성 질소의 기원과 거동 고찰 및 안전한 용수 공급을 위한 제언)

  • 김경호;윤성택;채기탁;최병영;김순오;김강주;김형수;이철우
    • The Journal of Engineering Geology
    • /
    • v.12 no.4
    • /
    • pp.471-484
    • /
    • 2002
  • Alluviums in the Keum River watershed cover an areal extent of $3,029{\;}\textrm{km}^2$ and contain about 8.1 billion tons of groundwater. However, the waters are severely polluted by nitrate, possibly due to the application of nitrogen fertilizer (>250 N kg/ha) on agricultural land. This paper aims to elucidate the pollution status and behaviors of nitrate in alluvial groundwaters in the Keum River watershed area, based on regional hydrogeochemical study. Most of the collected samples (n = 186) are polluted by nitrate (average = 42.2 mg/L, maximum = 295 mg/L). About 29% of the samples have the nitrate concentrations exceeding Korean Drinking Water Standard (44 mg/L $NO_3$). The distribution of nitrate concentrations in the study area is largely dependant on geochemical environments of alluvial aquifers. In particular, the decrease of redox potential of alluvial groundwaters showed a good correlation with the decreases of nitrate, iron, and manganese concentrations. Thus, the change of redox state in alluvial aquifers, likely reflecting their sedimentary environments, controls both the behavior and fate of nitrogen compounds and their natural attenuation (denitrification) in aquifers. A carbon-rich, silty layer within alluvium strata forms a reducing condition and possesses a buffering capacity on nitrate pollution.