• Title/Summary/Keyword: 충격 위치탐지

Search Result 25, Processing Time 0.026 seconds

Impact localization on a composite plate using multiplexed FBG sensors and error-outlier algorithm (다중화된 FBG 센서와 error-outlier 알고리즘을 이용한 복합재 평판에 대한 충격위치탐지)

  • Park, Sung Yong;Kim, Sang-Woo;Park, Sangyoon
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.6
    • /
    • pp.32-40
    • /
    • 2018
  • An impact localization for a carbon fiber reinforced plastic (CFRP) composite plate was performed using the multiplexed fiber bragg grating (FBG) sensors and the error-outlier based impact localization algorithm. We found that the optimal impact localization with the maximum error of 31.82 mm and the averaged error of 6.31 mm are obtained when the error threshold (ET) and constant level (CL) are 0.3 nm and 110, respectively. Moreover, the detailed process of impact localization under certain optimal parameters and the relevant results were thoroughly investigated. We conclude that the multiplexed FBG sensors and the error-outlier based impact localization algorithm are suitable for an impact localization on composite structures, and expect that they can be utilized for various structural health monitoring (SHM) in the future.

Impact and Damage Detection Method Utilizing L-Shaped Piezoelectric Sensor Array (L-형상 압전체 센서 배열을 이용한 충격 및 손상 탐지 기법 개발)

  • Jung, Hwee-Kwon;Lee, Myung-Jun;Park, Gyuhae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.5
    • /
    • pp.369-376
    • /
    • 2014
  • This paper presents a method that integrates passive and active-sensing techniques for the structural health monitoring of plate-like structures. Three piezoelectric transducers are deployed in a L-shape to detect and locate an impact event by measuring and processing the acoustic emission data. The same sensor arrays are used to estimate the subsequent structural damage using guided waves. Because this method does not require a prior knowledge of the structural parameters, such as the wave velocity profile in various directions, accurate results could be achieved even on anisotropic or curved plates. A series of experiments was performed on plates, including a spar-wing structure, to demonstrate the capability of the proposed method. The performance was also compared to that of traditional approaches and the superior capability of the proposed method was experimentally demonstrated.

Estimation of Impulse Position on the Plate Using Artificial Neural Network (신경망회로를 이용할 평판의 충격위치 탐지)

  • Lee Sang-Kwon;Lee Joo-Yung;Park Jin-Ho
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.333-336
    • /
    • 2004
  • 원자력 구조물, 항공기 구조물 등의 손상은 각 구조물의 손상에 의해서 발생하는 충격파의 탑지로서 손상의 위치를 탐지 할 수가 있다. 이러한 손상의 위치를 탐지하기 위한 역변환 문제는 오랜 기간 동안 중요한 연구의 과제가 되고 있다. 본 연구에서는 신경망 회로 기술을 이용하여 이러한 충격파를 탐지하고자 하며, 이 기술의 검증을 위해서 평판에서 실험을 실행하여 검증 하였다.

  • PDF

Theoretical Considerations in the Application of Impact Echo and Impulse Response Techniques to Integrity Tests on Drilled Shafts (I) (현장타설말뚝의 비검측공 건전도시험법에 관한 해석적 고찰 (I))

  • 이병식;이원구
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.5
    • /
    • pp.97-105
    • /
    • 2001
  • 현장타설말뚝의 건전도 평가에서 충격반향, 충격응답기법과 같은 비검측공 시험법을 적용하는 사례가 점차로 증가되는 추세에 있다. 비검측공시험법의 적용성을 체계적으로 평가하기 위해 수행된 일련의 연구결과 중에서 본 논문에서는 시험법의 결함탐지 능력을 평가하기 위해 수행된 해석적 연구결과에 관해 논한다. 이 연구에서는 시험법의 결함탐지능력에 대한 제반 영향인자 중에서 결함의 유형, 위치 및 크기의 영향을 평가하고자 하였다. 이를 위해서 여러 가지 조건에서 말뚝머리에 작용하는 충격하중에 대한 흙-말뚝 구조의 동적응답을 ABAQUS를 이용한 유한요소법으로 해석하였다. 이로부터 얻은 신호를 충격반향 혹은 충격응답기법으로 처리.분석하여 각 시험법의 결함탐지 능력을 평가해 보았다. 연구결과 이들 두 기법 모두 결함의 위치와 유형은 비교적 정확하게 탐지하는 것으로 나타났다. 그러나 충격응답기법을 이용하여 추정한 결함 크기는 신뢰도가 매우 낮았다. 이 문제를 해소하여 시험법의 적용성을 향상시키기 위해서는 측정된 동적응답신호를 이용하여 적절한 역계산 기법을 개발하여 적용할 필요가 있다는 결론을 얻었다.

  • PDF

Parametric Study on the Impact-Echo Method using Mock-Up Shafts (모형말뚝을 이용한 충격반향기법의 영향 요소 연구)

  • ;Kim, Hyung-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.3
    • /
    • pp.131-144
    • /
    • 2000
  • 본 연구는 비검측공 시험법으로서 널리 사용되고 있는 충격반향기법(impact-echo test)의 적용서을 수치해석 및 실내 실험을 통하여 분석해 보았다. 즉, 결함이 없는 말뚝과 결함이 있는 말뚝에 대하여 1차원 및 2차원 축대칭 유한요소해석을 실시하였으며, 또한 모노캐스트라고 하는 일종의 플라스틱 원형 봉의 말뚝에 축대창 공극, 비축대칭 공극, 병목부 및 단면 확대부와 같은 결함을 각각 크기와 깊이를 변화시켜 제작한 후 공기 중과 지반 내부에서 충격반향기법 실험을 수행하였다. 실험결과 충격반향기법의 말뚝 결함 탐지능력은 수치해석에서 얻은 결과와 함께 결함의 크기와 위치에 영향을 받는 것으로 나타났으며 결함의 크기가 커질수록 탐지의 정확도가 향상되는 것을 알 수 있었다. 결함의 상대면적이 말뚝 단면적의 50% 이상이면 충격반향기법에 의하여 결함의 위치를 파악할 수 있는 것으로 나타났으며, 공기 중 보다 지반에 근입 된 말뚝의 경우가 더욱 명확한 신호를 제공해주는 것으로 나타났다. 그리고 시간영역의 신호가 주파수 영역의 신호 보다 말뚝의 결함 크기에 더 민감히 반응하므로 주파수 영역에서 탐지할 수 없는 작은 크기의 결함을 시간 영역에서는 탐지할 수 있는 것으로 나타났다.

  • PDF

CWT-Based Method for Identifying the Location of the Impact Source in Buried Pipes (연속웨이브렛 변환을 이용한 충격음 위치 규명)

  • Kim, Eui-Youl;Kim, Min-Su;Lee, Sang-Kwon;Koh, Jae-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1555-1565
    • /
    • 2010
  • This paper presents a new method for indentifying the location of impact source in a buried duct. In a gas pipeline, the problem of leakage occurs due to the mechanical load exerted by construction equipment. Such leakage can cause catastrophic disasters in gas supply industries. Generally, the cross-correlation method has been used for indentifying the location of impact source in a pipeline. Since this method involves the use of the dispersive acoustic wave, it derives an amount of error in process of estimating the time delay between acoustic sensors. The object of this paper is to estimate the time delay in the arrival of the direct wave by using the wavelet transform instead of the dispersive wave. The wavelet transform based method gives more accurate estimates of the impact location than the cross-correlation method does. This method is successfully used to identify the location of impact force in an actual buried gas duct.

Fault Detection Method for Ceramic Cup by Pseudo Reverberation Time Based on Output Data by Impact Test (충격 시험의 출력 데이터에 기초한 유사잔향 시간을 이용한 도자기의 결함 탐지법)

  • Park Seok-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.6
    • /
    • pp.257-268
    • /
    • 2006
  • To determine the faults of ceramic cup it is proposed to use pseudo reverberation time concept estimated by impact test in room. Schroeder curves estimated from impact test for a cup with small crack and without one are utilized to estimate pseudo reverberation time. Pseudo reverberation times are compared and discussed according to a sort of impact hammers and impact points and also boundary conditions. As a result. proposed method is proved to be very useful to detect the existence of faults for candidate cups.

Determination of Impact Source Location Using a Single Transducer and Time Reversal Technique (단일센서와 시간역전법을 이용한 판에서의 충격위치 결정에 관한 연구)

  • Jeong, Hyun-Jo;Cho, Sung-Jong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.47-55
    • /
    • 2012
  • A structural health monitoring technique for locating impact position in a plate structure is presented in this paper. The method employs a single sensor and spatial focusing of time reversal (TR) acoustics. We first examine the TR focusing effect at the impact position and its surroundings through simulation and experiment. The imaging results of impact points show that the impact source location can be accurately estimated in any position of the plate. Compared to existing techniques for locating impact or acoustic emission source, the proposed method has the benefits of using a single sensor and not requiring material properties and geometry of structures. Furthermore, it does not depend on a particular mode of dispersive Lamb waves that is frequently used in other ultrasonic testings of plate-like structures.

Impact Damage Detection in a Composite Stiffened Panel Using Built-in Piezoelectric Active Sensor Arrays (배열 압전 능동 센서를 이용한 복합재 보강판의 충격 손상 탐지)

  • Park, Chan-Yik;Cho, Chang-Min
    • Composites Research
    • /
    • v.20 no.6
    • /
    • pp.21-27
    • /
    • 2007
  • Low-velocity impact damage in a composite stiffened panel was detected using built-in piezoelectric active sensor arrays. Using these piezoelectric active sensors, various diagnostic signals were generated to propagate Lamb waves through the structure and the responses were picked up to detect changes in the structure's vibration signature due to the damage. Three algorithms - ADI(Active Damage Interrogation), TD RMS (Time Domain Root Mean Square) and STFT (Short Time Fourier Transform) - were examined to express the features of the signal changes as one damage index. From damage detecting tests, two impact induced delaminations were detected and the location was estimated with the algorithms and diagnostic signals.

Impact Source Location on Composite CNG Storage Tank Using Acoustic Emission Energy Based Signal Mapping Method (음향방출 에너지 기반 손상 위치표정 기법을 이용한 복합재 CNG 탱크의 충격 신호 위치표정)

  • Han, Byeong-Hee;Yoon, Dong-Jin;Park, Chun-Soo;Lee, Young-Shin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.391-398
    • /
    • 2016
  • Acoustic emission (AE) is one of the most powerful techniques for detecting damages and identify damage location during operations. However, in case of the source location technique, there is some limitation in conventional AE technology, because it strongly depends on wave speed in the corresponding structures having heterogeneous composite materials. A compressed natural gas(CNG) pressure vessel is usually made of carbon fiber composite outside of vessel for the purpose of strengthening. In this type of composite material, locating impact damage sources exactly using conventional time arrival method is difficult. To overcome this limitation, this study applied the previously developed Contour D/B map technique to four types of CNG storage tanks to identify the source location of damages caused by external shock. The results of the identification of the source location for different types were compared.