• Title/Summary/Keyword: 충격음

Search Result 465, Processing Time 0.027 seconds

Rating Floor Impact Noise in Apartment Buildings Through Subjective Evaluation Tests (청감실험에 의한 공동주택 바닥충격음의 평가등급 설정)

  • 전진용;류종관
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.88-95
    • /
    • 2003
  • The auditory experiments based on subjective responses were undertaken for the standard heavy and light weight impact noise and rubber ball impact noise, jumping noise to investigate relations between floor Impact noise levels and subjective responses and to establish the upper/lower limits of floor impact noises. As a result, it was shown that relations between floor Impact noise levels and subjective responses was linear and the lower limit of heavy-weight impact noise was L/sub i, Fmax, AW/=46㏈ and the lower limit of light-weight impact noise was L'/sub n,AW/=56㏈. Finally the 3 subjective classes of floor impact noises were established.

Variation Characteristics of Floor Impact Sound by Ceiling Structures in Apartment Buildings (공동주택에 천장구조에 의한 바닥충격음 변화특성에 관한 연구)

  • 조창근
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.13-16
    • /
    • 1993
  • 본 연구에서는 공동주택의 바닥충격음 차음성능 향상을 위한 설계자료의 제시를 위해 천장구조가 서로 다른 공동주택을 대상으로 경량 및 중량 바닥충격음의 현장측정을 통하여 공동주택의 천장구조에 의한 바닥충격음 변화특성을 분석하고 차음성능을 평가하였다. 측정대상 건물에서 천장을 설치한 경우가 비교적 높은 충격음 차음성능 분포를 보이는 것으로 나타났으며, 바닥슬래브 하부 천장에 공기층과 완충재를 함께 설치하는 것은 기존 공동주택 등에서 경량 및 중량 바닥충격음 차음성능을 향상시키기 위한 효과적인 방안임을 확인하였다.

  • PDF

Correlation between Dynamic Characteristics of Isolation Material and Impact Noise Reduction of Light-weight Impact Source (충격음 저감재의 동특성과 실험실 경량충격음레벨 저감량의 상관관계)

  • 이주원;정갑철;권영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.191-195
    • /
    • 2003
  • 충격음 저감재의 동탄성계수와 감쇠계수는 차단성능을 평가하는데 있어 중요한 물성치가 된다. 저감재의 동탄성계수는 뜬바닥구조의 고유진동수를 결정짓게 되며, 저감재의 동탄성계수가 높을수록, 즉 고유진동수가 높아짐에 따라 실험실 경량충격음레벨 저감량은 지수함수적으로 감소됨을 실험을 통해 알 수 있다. 또한, 저감재를 포함한 뜬바닥구조를 1자유도 진동계로 가정한 이론값과 실험실 경량충격음레벨 저감량의 결과가 비교적 잘 일치하는 것으로 나타났으며, 이 때 감쇠계수의 영향은 반드시 고려되어야 한다.

  • PDF

Characteristics of Floor Impact Noise Insulation for No Hanger Ceiling Structure in Apartment Building (공동주택 무달대 천장의 바닥충격음 차단 특성)

  • Park, Hong-Gun;Mun, Dae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.208-213
    • /
    • 2014
  • 공동주택의 천장구조는 바닥충격음을 변화시키는 영향요소중의 하나이다. 천장구조의 진동응답 특성이 바닥충격음에 영향을 주는 요소를 확인하기 위해 천장구조의 달대를 제거하여 콘크리트 슬래브의 진동이 천장구조에 전달되지 않는 무달대 천장구조를 개발하였다. 달대가 시공된 일반 천장구조와 대비하여 무달대 천장구조의 천장판 가속도와 바닥충격음 레벨을 비교하였다. 무달대 천장구조를 사용함으로서 콘크리트 슬래브의 진동이 천장구조에 전달되는 것을 절연되어 천장구조의 진동응답 증폭을 저감시킬 수 있었으며, 저주파 대역의 바닥 충격음 증폭 또한 저감시킬 수 있었다. 일반 천장구조는 100 Hz 이하에서 천장구조의 진동응답이 증폭되어 저주파 대역 바닥충격음이 증폭되었다.

  • PDF

Analysis of the Reverberation Time in the Normalized Impact Sound Pressure Level (경량충격음 평가시 잔향시간 영향에 대한 고려)

  • Park, C.Y.;Hong, G.P.;Kim, S.H.;Jang, D.W.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.952-955
    • /
    • 2007
  • 경량충격음레벨을 평가하기 위해서는 수음실의 잔향시간을 측정하여 규준화 바닥충격음레벨을 구하여야 한다. 본 논문에서는 규준화 바닥충격음레벨과 표준화 바닥충격음레벨을 구할 때 고려하는 보정레벨을 중심으로 등가 흡음력을 결정하는 잔향시간과 수음실의 체적을 변수요인으로 분석하였다. 그 결과 측정된 잔향 시간은 공간에 관계없이 기준보다 2배 이상 길게 나타났고, 등가 흡음력은 기준보다 침실의 경우 1/2 정도 작지만 거실의 경우 기준과 거의 유사하게 나타나 침실의 경우 두 보정레벨이 유사하지만 거실의 경우 전자가 후자보다 낮게 보정되는 것으로 나타났다.

  • PDF

Characteristics of Impact Force and Floor Impact noise for Man Walking and Standard Impact Sources (보행과 표준중량충격원의 충격력 및 바닥충격음 특성)

  • Park, Hong-Gun;Mun, Dae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.216-224
    • /
    • 2014
  • 층간소음의 대부분의 원인이 아이들 뛰거나 발걸음으로 나타나고 있어 층간소음 저감을 위한 선행 연구로 층간소음의 주요 충격원인 보행 행위에 대한 정밀한 연구가 필요하다. 성인 보행 충격력과 그에 따른 바닥충격음을 계측하여 보행하중이 바닥충격음에 영향을 주는 요소를 분석하였다. 보행하중 중 발 뒤꿈치 충격력은 전체 충격하중을 주파수 특성을 대변할 수 있는 임펄스 형태의 하중으로 충격력은 뱅머신 또는 고무공보다 낮지만 1 차 영점(First zero)이 80Hz 정도로 높아 유효 가진 주파수 대역이 표준 중량충격원 보다 높았다. 구조물과 수음실의 고유모드 특성으로 인해 외부 충격에 대한 구조체 진동 및 음압의 공진 현상이 발생되기 때문에 공진 성분이 포함되는 바닥충격음 레벨은 순수 충격력 특성인 보행 또는 표준 중량충격원의 옥타브 밴드 충격력 폭로레벨과는 전혀 다른 주파수 특성을 나타내었다.

  • PDF

Performance Evaluation of the Floor Impact Sound Insulation in Steel Framed Modular House (강재프레임 모듈러주택의 바닥충격음 성능평가)

  • Chun, Young-Soo;Bang, Jong-Dae;Kim, Gap-Deug;Yoo, Song-Lee
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.81-89
    • /
    • 2014
  • This paper presents various attempts to secure the floor impact sound insulation performance on the dry floor system of steel framed modular house that lately attracted domestic attention. Test results show that in the condition of using dry floor system of D31(D32), the light-weight impact noise performance records the top level in the floor impact sound insulation performance grading system. the heavy-weight floor impact noise performance meets the minimum sound level limit in the floor impact sound insulation performance grading system that enacted regulation on housing construction standards.

Study on the Test Method of Impact Sound Pressure Level Using the Miniature Mortar (축소모형 시험판을 이용한 바닥충격음 측정방법에 관한 연구)

  • Park, Cheol-Yong;Hong, Gu-Pyo;Lee, Sang-Jun;Kim, Jin-Kyu;Kim, Kyu-Rae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1446-1449
    • /
    • 2007
  • 인정바닥구조는 신청에서부터 인정서 발급까지 기본적으로 2개월 이상이 소요되며, 신청 제품이 많을수록 그 기간은 길어지게 된다. 본 논문은 이와 같은 완충재의 성능을 확인하기 위해 소요되는 기간과 비용을 획기적으로 단축할 수 있는 간편한 방법을 제시하기 위한 것이다. 완충재 설치 이후 습식으로 시공되는 경량기포콘크리트와 모르터를 사전에 일정 크기로 제작(축소모형 시험판)한 후 골조가 완성된 현장에서 바닥충격음을 측정하는 방법이다. 완충재 2개 제품에 대하여 축소모형 시험판을 이용하여 측정한 결과와 전체 세대를 시공한 후 측정한 결과를 비교한 결과 경량충격음은 축소모형 시험판이 훨씬 낮은 결과를 나타냈지만 중량충격음은 비슷한 결과를 나타냈다. 이로써 축소모형 시험판을 이용하여 바닥충격음을 측정하는 것은 경량충격음을 저감하기 위한 재료 선정 및 제품 시스템 구성 등에 활용될 수 있을 것이며, 현장에서 중량충격음 차단성능을 신속하게 검증할 수 있는 방법으로 활용할 수 있을 것으로 기대된다.

  • PDF

A Working plan of classification against Floor Impact Sound (바닥충격음의 등급화 시공방안)

  • Jeong Gab-Cheol
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.170-173
    • /
    • 2004
  • The law about floor impact sound goes into effect from March 23th in 2004 and is applying to new designs. According to the new law, the minimal of slab thickness is 180mm by standard floor structure and the new law presents about the minimal standard about heavy-weight impact sound. Also, It presents about classification of light-weight sound separate the minimal standard, so demand of consumers can be accepted. But a working plan of classification about light-weight sound is not presented in accordance with field test, so the problem that design can't be achieved although the aim of design is formed. This study shows contents to investigate for working of classification and will be helpful to designers and construction corporations.

  • PDF

Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source (표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가)

  • Yong-Bong Lee;Hyok-Je Kwon;Chang-Whan Kim;Man-Hee Cho;Hang Kim;SungSoo Jung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.143-151
    • /
    • 2023
  • In this paper, a method for evaluating the measurement uncertainty is proposed when measuring of floor impact sound insulation of buildings using standard heavy impact source. In addition to the effect of repeated measurements, several other factors such as measurement location, impact location, equipment used for sound pressure measurement, and heavy impact source, were considered. A mathematical model for the average maximum impact sound level and the uncertainty evaluation method for each factor were proposed. The present proposed method was applied to measurement results to evaluate the average maximum impact sound pressure level and the measurement uncertainty.