• Title/Summary/Keyword: 충격소음

Search Result 815, Processing Time 0.025 seconds

An experimental study for developing of silencer to be adapted large gun (대구경 화포용 소음기 개발을 위한 실험적 연구)

  • Lee, Hae suk;Park, Sung ho;Kim, Sang min;Kang, Tae yeop;Kim, Heung soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.558-563
    • /
    • 2014
  • To reduce the transmission of large gun-generated noise from the firing test range to the community, we have tested a silencer to be used with howitzer(155mm KM114A2) after simulation. Numerical analysis was conducted by using a commercial CFD code, FLUENT. To analyze complex blast flow fields, the Spalart-Allmaras model was applied under 2 dimensional and axisymmetric conditions. Firing tests were also performed with the KM114A2 howitzer while the silencer was installed. This paper describes a result of comparison between results of computer analysis and test outcomes which were gotten by firing 155mm projectiles at the testing range. This paper will also be informative to the muffler design which will be adapted to 155mm large gun in the future.

  • PDF

A Study on the Aerodynamic Noise of a Supersonic Exhaust Nozzle of Perforated Tube (다공관형 초음속 배기노즐의 공력소음에 관한 연구)

  • 이동훈
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.113-120
    • /
    • 1999
  • A perforated tube nozzle as an exhaust noise suppressor of a high-speed civil transport(HSCT) is proposed. The experimental results for the near and far field sound. the visualization of jet structures and the static pressure distributions in the jet passing through a perforated tube are presented and discussed in comparison with those for a simple tube. It is shown that the perforated tube has an excellent performance to greatly reduce the shock-associated noise and that also the turbulent mixing noise is reduced in the range of a limited jet pressure ratio. This considerable noise reduction is due to the pressure relief caused by the through-flow through the perforated holes. Such a pressure relief results in the transformation of normal shock waves into weak Mach waves of X -type and increases the thrust force of the perforated tube nozzle.

  • PDF

Experimental Study for Developing Silencer Adapted by Large Caliber Gun (대구경 화포용 소음기 개발을 위한 실험적 연구)

  • Lee, Hae-Suk;Park, Sung-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.9
    • /
    • pp.593-598
    • /
    • 2015
  • In this paper, the silencer for large caliber gun to reduce the propagation of gun-generated noise was studied. The results of structural analysis and firing test were described. Structural analysis was conducted by using a commercial program, ANSYS, and showed that there was not any structural problem. The sound pressure level was diminished about 10 dB by the silencer adapted in front of the gun and the soundness of the material was verified from the internal pressure measurement. The reduction of weight, improvement of durability and speed-up of actuating device have to be studied later to improve the usability of silencer for large caliber gun.

Source localization of impact noise on an indoor unit of air-conditioner (에어컨 실내기에서 발생하는 충격 소음원의 위치 추정)

  • 최영철;김양한;이종구;김구영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.324-329
    • /
    • 2003
  • An air-conditioner has various noise sources such as cooling fan noise, pumping noise, flow noise and impact noise. Among these, impact noise is the most unpleasant source. This is because the noise is produced in indoor unit of air-conditioner. To control the noise source effectively, first we must identify the noise sources. When we identify impact noise source, the measurement have to be carried out simultaneously. So we use beamforming method that requires less measurement points than intensity method and acoustic holography. The objective of this paper is to estimate the location of impact source. This objective can be achieved by using minimum variance cepstrum that is able to detect impulse embedded in noise. In this study, modified beamforming method based on cepstrum domain is proposed. Then this method applied to air-conditioner noise sources which produce impact noise.

  • PDF

A Development of COS Holder to Reduce an Impact Ambient Noise (충격성 소음 감소용 COS 홀더 개발)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1062-1068
    • /
    • 2007
  • We are using COS to block the excess current and to protect the transformer. But the fuse of COS is melt due to the overload resulting from the excess current flows and it destroys an air severing relations to clear as strong arc happens. Such phenomenon induces an impact ambient noise and it gives the circumstance area resident or pedestrian the fear. Thus, it is necessary that we urgently need to control the ambient noise from the actual circumstances. In this study, we investigate the characteristic of an impact ambient noise associate with the melting state of the COS fuse and suggest the method to reduce the noise.

  • PDF

Comparison Between the Dynamic Properties and Noise Isolation Performances for a Floor Impact Isolation Pad (바닥충격음 완충재의 동적특성과 소음저감 성능 비교)

  • Yang, Soo-Young;Lee, Dong-Hoon;Hong, Boung-Kuk;Song, Hwa-Young;Lee, Joo-Wone
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.275-278
    • /
    • 2005
  • In this study, the dynamic properties of a floor impact sound isolation pad expressed in terms of the natural frequency, the dynamic stiffness per unit area and the loss factor are measured by the resonant method. By using the measured dynamic properties, the vibration transmissibility diagram is obtained for each isolation pad, which is compared with the values tested by the impact sound sources at the room in an apartment. From the comparative results, it is found that the noise reduction Performances. of isolation pads are closely connected with the natural frequency and the dynamic stiffness per unit area.

  • PDF

Characteristics of a Rubber-Ball Impactor to Evaluate Floor Impact Noise (바닥 충격음 평가를 위한 고무공 충격원의 특성)

  • 문형준;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.592-597
    • /
    • 2002
  • The purpose of this study was to analyze the characteristics of a new heavy weight impactor, the Rubber Ball. Until now Bang-machine has been used to measure the heavy impact noise in accordance with JIS A 1418-1. However, various kinds of examination methods have been needed to make an objective observation of insulation capacity for floor impact noises. Two types of experiments were undertaken. First, the experiment about noise was carried out about an apartment building in actual living condition. Then. vibration noises from the impactors were analyzed. The results of this study were as follows : the result of experiment carried out with bonded area of bail was closer to practical experiment than that of non bonded area. In addition, the result about bonded area of ball was more similar to the result which is claimed by H. Tachibana than that about non bonded area. Moreover, it was found that Rubber Ball has more similar vibration characteristics to the real impact noise source than Bang-machine.

  • PDF

Analysis of Reduction Effect of Inter-Floor Noise Using Active Noise Control (ANC) Technique (능동소음제어 기술을 이용한 층간소음 저감효과 분석)

  • Hojin, Kim;Joong-Kwan Kim;Junhwan Kim;Hyunsuk Kim;Hyuk Wee
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.3
    • /
    • pp.45-56
    • /
    • 2023
  • In this study, the application of ANC (Active Noise Control) technology to address inter-floor noise was explored. To achieve this, an ANC system was developed to manage the heavy impact sound within the frequency range of 40 to 500 Hz. The ANC system utilized an adaptive filter employing a feedforward approach based on the Fx-LMS algorithm. To set up the ANC system, a comprehensive analysis of various variables within the system was performed using computational simulations. This process enabled the identification of optimal filter settings and system configuration arrangements. In addition, the ANC system was implemented in the inter-floor noise test room at the Korea Conformity Laboratories (KCL). Through a certified standard testing procedure, it was confirmed that the ANC system led to a 4 dB reduction in inter-floor noise when the system was activated compared to when it was turned off. The results of this study indicate that the developed ANC system has an effect significant enough to elevate the rating criteria by one level for heavy impact sound.

Analysis for Anti-shock Characteristics of Underwater Acoustic Transducers to the Explosive Shock (수중폭발충격에 대한 수중음향 트랜스듀서의 내충격 특성 해석)

  • Goh, Byeong-Jun;Seo, Hee-Seon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.11 s.116
    • /
    • pp.1108-1114
    • /
    • 2006
  • Underwater acoustic transducers can be exposed to a underwater explosive shock caused by various types of underwater weapon. So, a robust anti-shock design is required for transducers to endure the underwater explosive shock. To check the anti-shock characteristics of a transducer, underwater explosive shock test is needed. The conditions of underwater explosive shock test are set up referring to various oversea explosive shock test specifications, and the explosive shock pressure values are calculated according to those conditions. Transient analyses art: carried out for two kinds of underwater acoustic transducer model to verify the anti-shock characteristics. The applied model has robust anti-shock characteristics enough to endure the explosive shock up to 2300 psi. In the future, the transducer design should be certified through the fields test, and modified if needed.

Evaluations on isolation method of floor impact sounds by real impact source (실충격원을 고려한 바닥충격음 저감방안의 평가)

  • Yoo, Seung-Yup;Lee, Pyung-Jik;Jeong, Young;Jeon, Jin-Yong;Ryu, Jong-Kwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.366-370
    • /
    • 2006
  • In this study, characteristics of impact force and impact sound of impact source such as bang machine, impact ball, and children's jumping were review. Results of review showed that impact ball has most similar characteristic to real impact sources in terms of objective properties such as impact force and impact sound. The effects of various isolator on floor impact sound were also investigated in apartment building and test facilities building using bang machine an impact ball. From the field measurement, it was found that the difference in reduction sound level between bang machine and impact ball was relatively large and the reduction sound level by impact ball was much larger than bang machine.

  • PDF