• Title/Summary/Keyword: 출력반응

Search Result 383, Processing Time 0.026 seconds

Deposition of Micropattern using The Laser Direct Writing Method with a polymer coating layer (폴리머 코팅층 레이저 직접묘화법을 이용한 미세패턴증착)

  • Lee, Bong-Gu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.6980-6985
    • /
    • 2014
  • A micro-conductive pattern was fabricated on an insulating substrate ($SiO_2$) surface using a laser direct writing method. In the LIFT process, when the laser beam irradiates a thin metal film, the photon energy is absorbed by the film and converted to thermal energy, and the thermal decomposition reaction produced by the resulting heat conduction forms a deposit on the substrate. The resistivity of the micro-electrodes deposited through LIFT process with and without polymer coating was measured. The results showed that the electric conductivity of the micro-pattern and micro-structure can be increased approximatly two times when the deposited micropattern is fabricated through a LIFT process with a polymer coating, compared to the case without a polymer coating.

Development of a PVDF sensor for detecting over-load and impact on large-scale mechanical structures (대형 기계 구조물의 과부하 및 충격 측정을 위한 PVDF 센서 개발)

  • Kang, Dong-Bae;Ahn, Jung-Hwan;Kim, Gang-Yeon;Son, Seong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6399-6405
    • /
    • 2014
  • An external overload or impact is an important factor affecting the safety of large-scale structures. The proposal of this paper is the development of a system for detecting overload and impulse using a single PVDF film sensor. In large-scale structures, the load causes the structure to be deformed and the impulse generates vibration on the structure. Generally, low frequency deformation or bending of a structure is measured with a strain gauge and the high frequency vibration is detected by an accelerometer. On the other hand, a single sensor that can detect both deformation and vibration has not been developed. In this study, the development of a detection system integrated with a polyvinylidene fluoride (PVDF) film sensor, amplifier, and software was attempted to monitor deformation and impact through a single sensor. The system was verified by the possibility of detecting overload and impulse, and the two filtered signals of the PVDF were compared with a conventional strain gauge and an accelerometer.

Artificial Intelligence Art : A Case study on the Artwork An Evolving GAIA (대화형 인공지능 아트 작품의 제작 연구 :진화하는 신, 가이아(An Evolving GAIA)사례를 중심으로)

  • Roh, Jinah
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.5
    • /
    • pp.311-318
    • /
    • 2018
  • This paper presents the artistic background and implementation structure of a conversational artificial intelligence interactive artwork, "An Evolving GAIA". Recent artworks based on artificial intelligence technology are introduced. Development of biomimetics and artificial life technology has burred differentiation of machine and human. In this paper, artworks presenting machine-life metaphor are shown, and the distinct implementation of conversation system is emphasized in detail. The artwork recognizes and follows the movement of audience using its eyes for natural interaction. It listens questions of the audience and replies appropriate answers by text-to-speech voice, using the conversation system implemented with an Android client in the artwork and a webserver based on the question-answering dictionary. The interaction gives to the audience discussion of meaning of life in large scale and draws sympathy for the artwork itself. The paper shows the mechanical structure, the implementation of conversational system of the artwork, and reaction of the audience which can be helpful to direct and make future artificial intelligence interactive artworks.

A CMOS Bandgap Reference Voltage/Current Bias Generator And Its Responses for Temperature and Radiation (CMOS Bandgap 기준 전압/전류 발생기 및 방사능 응답)

  • Lim, Gyu-Ho;Yu, Seong-Han;Heo, Jin-Seok;Kim, Kwang-Hyun;Jeon, Sung-Chae;Huh, Young;Kim, Young-Hee;Cho, Gyu-Seong
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1093-1096
    • /
    • 2003
  • 본 논문에서는, CMOS APS Image Sensor 내에 포함되어 회로의 면적을 줄인 새롭게 제안된 CMOS Bandgap Reference Bias Generator (BGR)를 온도 및 방사능에 대한 응답을 실험하였다. 제안된 BGR 회로의 설계 목표는 V/sub DD/는 2.5V이상이고, V/sub ref/는 0.75V ± 0.5mV 마진을 가지게 하는 것이다. 제안된 BGR회로는 Level Shifter를 갖는 Differential OP-amp단과 Feedback-Loop를 가지는 Cascode Current Mirror를 사용하여 저전압에서도 동작을 가능하게 하였으며, 높은 출력저항 특성을 가지도록 하였다. 제안된 BGR회로는 하이닉스 0.18㎛ ( triple well two-poly five-metal ) CMOS 공정을 이용하여 Test Chip을 제작하였다. 온도의 변화와 Co-60 노출조건 하에서 Total ionization dose (TID) effect된 BGR회로의 V/sub ref/를 측정하여, 이를 평가하였다. 온도에 대한 반응은, 25℃ 일 때의 V/sub ref/에 대해, 각각 45 ℃에서 0.128%. 70℃에서 0.768% 변화하였다. 그리고 온도가 25℃일 때 50krad와 100krad의 방사능을 조사 하였을 경우, V/sub ref/는 각각 2.466%, 그리고 4.612% 변화하였다.

  • PDF

The Effects of Low Power Laser Treatment on Tissue Inflammatory Reactions in the Linear Incision Wound on Rat Skin (흰 쥐의 선상 절개 창상모델에서 저출력 레이저 자극이 조직 염증반응에 미치는 영향)

  • Lim, In-Hyuk;Lee, Jeong-Weon;Kim, Hyun-Sook
    • Physical Therapy Korea
    • /
    • v.10 no.2
    • /
    • pp.61-70
    • /
    • 2003
  • The purposes of this study was to evaluate the effect of low power GaAsAl laser on tissue contraction in a linear incision wound on rat skin. The linear incision wound was made on the midline of the backside in the experimental animals. Low power laser applications with different intensities such as 3, 6, or 10 mW were applied to the experimental animals twice a day for 10 days. On either the seventh or tenth postoperative day, the quantitative analysis of the inflammatory reaction surrounding the linear incision wounds on the rats were performed using enzymatical analysis of myeloperoxidase (MPO) activity. The number of neutrophil was $.07-1.0{\times}106/m{\ell}$ from a normal blood sample that was obtained from the normal experimental animals. Each concentration of neutrophil showed .04-.62 unit activity of MPO. Therefore, the 6 unit activity of MPO per neutrophil was $.57{\pm}.014{\times}10^{-6}$ unit. On the 7th and 10th post operative day, non treated tissues demonstrated increased MPO activity as compared to that of normal tissue. These data indicated that the inflammatory reaction of tissue was induced after wound induction and the MPO activity were increased in the inflammed tissues. While both 3 mW or 6 mW intensity of laser treatments did not affect the tissue MPO activity, 10 mW intensity of laser treatment significantly decreased the tissue MPO activity on the 7th and 10th post operative day. These data demonstrated that only 10 mW intensity of laser treatment successfully suppressed tissue inflammatory reaction after wound induction. In conclusion, these findings suggested that 10 mW of GaAIAs laser treatments effectively suppressed the inflammatory reaction of tissue that was induced during the wound healing process.

  • PDF

A Study on High Efficiency Power Conditioning System for Safety Operation of PEMFC_type Fuel Cell Generation System (고분자전해질형 연료전지 발전시스템의 안전운전을 위한 고성능 전력변환기에 관한 연구)

  • Kwak Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.1 s.38
    • /
    • pp.57-61
    • /
    • 2006
  • Fuel cells are direct current (DC) power generators. They generate electricity through an electrochemical process that converts the energy stored in a fuel directly into electricity. Fuel cells have many benefits, which produce no particulate matter, nitrogen or sulfur oxides. And they have few moving parts and produce little or no noise. When fueled by hydrogen, they yield only heat and water as byproducts. Their wide application can reduce our dependence on fossil fuels and foreign sources of petroleum. This paper is studied on a high efficiency power conditioning system (PCS) applied to the proton exchange membrane fuel cell (PEMFC) generation system. This paper is designed to a novel PCS circuit topology of high efficiency. Some experimental results of the proposed PCS is confirmed to the validity of the analytical results.

  • PDF

Study on Rector Dynamic Response by Cross Correlation Method (상호상관함수법에 의한 원자로 동특성에 관한 연구)

  • 고병준
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.10 no.4
    • /
    • pp.60-73
    • /
    • 1973
  • The reactor noise analysis was performed by the cross correlation method using two detectors to determine the dynamic stability and the system parameter of TRIGA Mark-II reactor under critical and subcritical conditions. The a values turned out to be 46.67 and 70.04 respectively at zero power and full power under critical condition, while 79.47 and 97.59 respectively at the safety rod dropping and the regulating rod dropping under subcritical condition. Prompt neutron life time of TRIGA Mark-II reactor measured 107 and 160 $\mu$sec, and shut down margin was -10.03$\times$10-4 at the safety rod dropping and -29-43$\times$10-4 at the regulating rod dropping CDC 3100/MSOS digital computer, HITACHI 505 Analog computer, and preamplifier, bandpass filter, FM modulator or demodulator designed for this specific purpose, were employed for the present investigation.

  • PDF

A Comparative Study on the 1-D and 3-D Load Follow Analysis Methods of Light Water Reactor (경수로의 부하추종 운전에 대한 1차원 및 3차원 해석방법의 비교 연구)

  • Kim, Chang-Hyo;Lee, Sang-Hoon;Chung, Chang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.19 no.1
    • /
    • pp.34-41
    • /
    • 1987
  • This work concerns with a comparison of the 1-dimensional (or 1-D) load follow analysis method with reference to the detailed 3-dimensional (or 3-D) computations. For this purpose a 1-D two-group finite difference code, HLOFO, and a 3-D coarse-mesh code based on the modified Borresen's method, CMSNAC, are developed. The CMSNAC code is used to obtain the 3-D power peaks and reactivity parameters in response to power swing from 100 to 50 and back to 100% in the 12-3-6-3 load cycle for the BOL of the KORI Unit 1 PWR core. The 3-D result is then compared with the 1-D HLOFO computations, the cross section and buckling inputs of which are obtained by combining the flux-volume weighting scheme with the approximate flux from the auxiliary 3-D computations. It is shown that the 1-D computation has a limited accuracy, yet it is confirmed that it can describe the core axial average behavior which is fairly consistent with the detailed 3-D computation.

  • PDF

Reduction of Conducted Emission in Interleaved RPWM Buck Converter (인터리브드 RPWM Buck 컨버터의 전도성 노이즈 감소에 대한 연구)

  • Lee, Seunghyun;Lee, Keunbong;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.4
    • /
    • pp.298-308
    • /
    • 2017
  • This paper presents a Interleaved Buck Converter(IBC) system with Random PWM to reduce electromagnetic noise by harmonics. Swithced mode power supply generally controlled by high switching frequency have a electromagnetic interference(EMI) issue due to the high-voltage/high-current switching to regulate the voltage in buck converter. To solve the problem. we present a novel IBC system with PRBS. IBC system has two active switches with 180 phase difference that controll the cicuit with two PWM signal. IBC system may be disadventageous for the cost due to the addtion of one set of switch, but it has adventages of power distribution, current ripple cancellation, fast transient response, and passive component size reduction. To verify the validity of study, simulation program has been bulit using PSIM and the experimental results of IBC system using RPWM was compared with the conventinal PWM and randomized PWM.

Fuel Cell Modeling and Load Controlling by the Variable Utilization of Airflow (연료전지 모델링 및 공기이용률 제어에 관한 연구)

  • Song, S.H.;Lee, W.Y.;Kim, C.H.;Park, Y.P.
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.1
    • /
    • pp.48-52
    • /
    • 2003
  • A mathematical dynamic model of fuel cell was formulated in order to design the control system which will meet the control object. The control objective is set to regulate the airflow in the load change by utilization of airflow and the pressure difference between anode and cathode is maintained below a limit range. Simulation result of 10kW polymer electrolyte membrane fuel cell (PEMFC) clearly demonstrates that response time need to be less. than 1 seconds for the control requirements. Besides, pressure difference was allowed in pressure range less than 0.01 atm.