• Title/Summary/Keyword: 축열밀도

Search Result 11, Processing Time 0.021 seconds

In-Situ Measurement of Chiller Performance and Thermal Storage Density of an Ice Thermal Storage System (빙축열 시스템 냉동기 성능 및 축열밀도 현장측정 기법연구)

  • Shin Younggy;Yang Hooncheul;Tae Choon-Seob;Cho Soo;Kim Youngil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1204-1209
    • /
    • 2005
  • In-situ measurement was made to evaluate chiller performance and thermal storage density of an ice thermal storage system. The system belonged to a big hotel and the measurement was conducted during late October. Owing to very small cooling load, the data logging was possible for a single thermal storage cycle. However, operation history of the chiller showed a relatively good spectrum of data for performance evaluation. COP and thermal storage density were calculated. The COP at full load was about 4.07, which was lower than $4.8\~6.4$ of new chillers. The measured storage density was about $10.9RT-h/m^3\;(=152MJ/m^3)$, which also was lower than a criterion of normal performance $(above\;13.0RT-h/m^3\;or\;181MJ/m^3)$. The study result provides technical basis for quantitative ESCO business scenario.

Property Change of Heat-reservoir Refractory Brick With Varying Compositions and Sintering Conditions Utilizing Mill-scale and Red-firing Clay As Raw Materials (밀스케일과 적점토를 원료로한 축열재에서 원료성분과 소성조선에 따른 특성 변화)

  • Kim, Jeong-Seog;Kim, Hong
    • Resources Recycling
    • /
    • v.8 no.1
    • /
    • pp.23-28
    • /
    • 1999
  • Firing characteristics, transverse rupture strength, and heat capacity were studied of the heat-reservoir refractory materials made of red-firing clay, mill scale, and water glass. The firing shrinkage increased with increase of the clay proportion in samples. The volume of fired bodies showed shrinkage by drying up to $300^{\circ}C$, steady expansion in the 300-$700^{\circ}C$ range due to phase transition of iron oxides. and drastic expansion above $1200^{\circ}C$. Flexural strength decreased from 5.6 Mpa to 2.35 Mpa with the decrease of the ratio of clay to mill scale from 1:1 to 1:3 Heat capacities changed from 1.1 Joul/g$^{\circ}$C to 1.35 Joul/g$^{\circ}$C with the ratio of millscale to clay ratio from 1:1 to 1:3. Mill scale in the specimen appears to exist as liquid phase during firing. Firing the specimens in air leads to the eruption of the molten mill scale to the sample surfaces. Contrarily, firing samples in a refractory sagger with a cover suppressed the eruption of the molten mill scale to the surfaces. The addition of mill scale gave rise to porous sintered bodies which would delay cooling rates of heat-reservoir brick.

  • PDF

A Numerical Study on the Discharging Performance of a Packing Module in a Thermal Storage Tank (축열조 내 패킹 모듈의 방열 성능에 대한 수치해석)

  • Lee, Yong Tae;Chung, Jae Dong;Park, Hyoung Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.625-631
    • /
    • 2015
  • In this study, a numerical analysis on the discharging performance of a thermal storage tank completely filled with packing modules is investigated. The enthalpy-porosity method is adopted to analyze phase change phenomenon. Using this method, the melting process of a packing module in the thermal storage tank was studied as the HTF (heat transfer fluid) flows down from the top of the tank at the discharging mode. There are some design factors such as the module arrangement and the number of modules, but this study focuses on the effects of varying the flow rate of the HTF on the outlet temperature of the HTF, molten fraction, and thermal storage density. As the flow rate increases, the outlet temperature of the HTF gets higher and the total melting time of the PCM decreases. Additionally, the thermal storage density is increased so that it reaches about 93% for the desired value.

Experiment on the Charging and Discharging Processes of a Closed Ice-Thermal-Energy-Storage System (밀폐식 빙축열시스템의 축열 및 방열과정에 관한 실험)

  • Kim, Kyung-Hwan;Yoon, Young-Hwan;Kim, Yeon-Kyu
    • Journal of Energy Engineering
    • /
    • v.16 no.4
    • /
    • pp.164-169
    • /
    • 2007
  • The decrease in the summer peak electric load in our country is very important. The government has arranged and implemented a lot of support policies and statutes to decrease the peak electric load. And the ice-thermal-energy-storage system is known as one of the alternatives. The purpose of this paper is to evaluate the performance and the total efficiency of its storage tank, conducting the charging operation, the parallel operation and the single operation of a storage tank. The thermal energy density stored and discharging efficiency of a storage tank and the efficiency of total energy utilization of system are $18.4\;USRT-h/m^3$, 96.2% and 2028.7 kcal/kWh under the operation of design condition. When the storage tank is supplied more ice thermal energy than design condition, it is estimated that the efficiency of system are lower than the design condition by the supercooled effect.

Study on the Performance Testing of the Closed Ice Thermal Energy Storage System using Screw Capsules (스크류 캡슐형 밀폐식 빙축열시스템의 성능시험에 관한 연구)

  • Kim, Kyung-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.39-45
    • /
    • 2006
  • The decrease in the summer peak electric load in our country is very important. The government has arranged and implemented a lot of support policies and statutes to decrease the peak electric load. And the ice thermal energy storage system is known as one of the alternatives. The purpose of this paper is to evaluate the efficiency and thermal characteristics of the closed ice thermal energy storage system using screw capsules. The measured thermal energy storage density is about 18.4 USRT-h/m3 (=232.9 MJ/m3), which is higher than 13.0 USRT-h/m3 (=164.6 MJ/m3), a low criterion of normal performance. And The efficiency of the discharging process and the total energy utilization is 96.2% and 2028.4 kcal/kWh respectively.

Analysis of Solidification Process Around a Vertical Tube Considering Density Change and Natural Convection (수직원관 주위에서 밀도차와 자연대류를 고려한 응고과정 해석)

  • 김무근;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.142-155
    • /
    • 1992
  • Numerical analysis is performed for the unsteady axisymmetric two dimensional phase change problem of freezing of water around a vertical tube. Heat conduction in the tube wall and solid phase, natural convection in liquid phase and volume expansion caused by density difference between solid and liquid phases are included in the numerical analysis. Existing correlation is used for estimating density-temperature relation of water, and the effect of volume expansion is reflected as fluid velocity at the interface and the free surface. As pure water has maximum density at 4.deg. C, it is found that there exists an initial temperature at which the flow direction reverses near the interface and by this effect the slope of interface becomes reversed depending on the initial temperature of water. By considering natural convection and solid-liquid density difference in the calculation, their effects on phase change process are studied and the effects of various parameters are also studied quantitatively.

환경공생을 고려한 주거환경기기$\cdot$시스템

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.266
    • /
    • pp.52-58
    • /
    • 1999
  • 주거환경기기$\cdot$시스템에서는 점차 지구환경보호, 환경공생에 대한 고려가 대단히 중요시되고 있는 추세이다. 이에 따라 생에너지성, 리사이클성, 프레온 규제 등에 대응하는 기술개발과 환경친화적인 성에너지의 실용화가 중요한 테마가 되고있다. 이 논문에서는 이에 대한 이쓰비시전기의 기본적인 대처와 분야별 기술개발의 현황 그리고 전망에 대하여 소개한다. 또한 냉동$\cdot$공조기기에 대하여는 프레온규제에 대응한 HCFC 냉매에서 HFC냉매로의 대체, 생에너지화의 관점에서 요소기술 개발, 룸에어컨과 냉장고의 생에너지화 추이, 그리고 업무용공조기에 대하여는 자연순환사이클과 빙축열시스템의 실용화 및 고성능화에의 대처, 나아가서는 고기밀$\cdot$고단열 주택에 대응하는 가정용 환기시스템과 리사이클성에 대한 노력에 대하여 기술하기로 한다. 주택설비 가전기기에 대해서는 형광등의 인버터화와 그것을 활용한 조광시스템에 의한 생에너지화의 추진, 전자동세탁기와 전자레인지 등의 생에너지화 연구, 가전제품 전반에 대한 주요과제인 대기전력 삭감에 대한 대처, 또한 전기온수기의 고성능화, 신에너지활용으로서의 주택용 태양광발전시스템의 현황과 대처에 대해서도 알아본다.

  • PDF

Physical Properties of Microencapsulated Phase Change Material Slurries (미립잠열슬러리의 물성에 관한 실험적 연구)

  • 이효진;홍재창;이재구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.860-869
    • /
    • 2000
  • The thermal conductivity and density of slurries entrained with the particles of Micro-PCM are measured with respect to its temperatures as well as concentrations. For the thermal conductivity of slurries, a device made from P.A. Hilton (Model No. H470) is adopted. There is a well-scaled 0.3 mm gap between shells into which the slurry is injected. The temperatures of the slurry are changed to $5~25^{\circ}C$ , for which it is controled by the supplied voltage and cooling water circulated around the outer shell. The concentrations of Micro-PCM slurries are varied from 5 wt% to 50 wt%. Some general equations such as Maxwell's equation, are evaluated for their applicability with Micro-PCM slurry. As a result, it happens to be some 20% discrepancy between the experiment and the applied equations. The density measurements of Micro-PCM slurry to its temperature and concentration are peformed by hydrometer. For the experiment, tetradecane encapsulated slurry (($t_m≒6^{\circ}C$) and a mixed wax ($t_m≒50^{\circ}C$) are tested. The temperature changes of tetradecane are applied for $0^{\circ}C\;to\;$20^{\circ}C$and a mixed wax for $20^{\circ}C\;to\;$60^{\circ}C$ and its concentrations are changed from 5 wt% to 30 wt%. The results are compared with a general equation and the referenced data. For the conclusion, the experimental result and a general equation are well agreed.

  • PDF

A study of heat transfer with Phase Change Material in heat storage system - Inward freezing in the vertical cylinder - (상변화물질을 이용한 축열조에서 열전달현상에 관한 연구 - 수직원통관 내에서 응고 열전달 -)

  • Lee, C.M.;Yim, C.S.;Iqbal, M.
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.53-64
    • /
    • 1993
  • This study investigated heat transfer phenomena during the freezing of an initially superheated or non-superheated liquid in a cooled cylinder tube. Numerical and experimental method were performed to obtatin the temperature and velocity distribution, the shape of interface. Natural convection effects in the superheated liquid were confined and moderated a short freezing time. After natural convection ceases, heat conduction dominated in the whole paraffin, so Crystal and much-zone were found out in PCM. Initial superheating of liquid tended to morderatly diminish the frozen layer thickness at short freezing times but little effect on the these quantities at longer times. On the amount of frozen mass, Iintial liquid superheating is less affected than tube wall subcooling.

  • PDF

An Experimental Study on Thermal Properties of Clathrate for Cold Storage Applications (저온축열용 포접화합물의 열물성에 관한 실험적 연구)

  • 한영옥;정낙규;김진흥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.725-734
    • /
    • 2000
  • The objective of this paper is to investigate the thermal properties of TMA clathrate applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are peformed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of concentrations and temperature of heat source in TMA clathrate. The results are summarized as follows; 1) temperature of phase change is dropped as the temperature of heat source is lower, 2) the effect of subcooling suppression with about $9.3^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 29wt% and 30wt% . Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$ Thus, it is concluded that TMA clathrate has proper properties as the cold storage medium for building air-conditioning.

  • PDF