• Title/Summary/Keyword: 축열물질

Search Result 95, Processing Time 0.031 seconds

Study on the Satellite Thermal Control Hardware Composed of Two Parallel Channels Working for Heat Pipe and Phase Change Material (열관과 상변화물질을 일체형으로 병렬 배열한 위성용 열제어 부품 연구)

  • Kim, Taig-Young;Hyun, Bum-Seok;Lee, Jang-Joon;Rhee, Ju-Hun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.11
    • /
    • pp.1087-1093
    • /
    • 2010
  • The satellite thermal control H/W composed of two parallel channels working for heat pipe (HP) and phase change material (PCM) is suggested for the high heat dissipating component which works intermittently with short duty. In a limited point of view, the HP-PCM device is a kind of off-the-shelf component that requires no dedicated configuration and thermal designs to PCM. Therefore, it can be used with less impact on the program cost and schedule different from most of the PCM applications. In present study the typical honeycomb structure radiator applying the HP-PCM device is designed and the detail thermal math model is developed for numerical analyses. The result comparison between without and with PCM shows that the HP-PCM device redistributes the peak heat around the whole mission period through the alternate melting and freezing of PCM, and, as a result, the maximum and minimum temperatures are effectively alleviated. The drawback of PCM application due to low thermal conductivity can be successfully resolved by means of parallel arrangement of HP channel.

A Study on Thermal Performance of Cement Mortar with PCM (PCM을 혼입한 시멘트 모르타르의 열적성능에 관한 연구)

  • Kim, Bo-Hyun;Lee, Han-Seung
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.521-528
    • /
    • 2011
  • Recently, environmental concerns and issues have become great concerns for the public. Therefore, this study is conducted with the objective of preventing energy depletion and $CO_2$ emission. PCM (Phase Change Materials) having latent heat characteristic is mixed in mortar to find a proper mix proportion. Also, the mortar properties and performances as well as a melting point of PCM when applied to air conditioning and heating conditions in at building environments were obtained by performing experiments. Also, latent heat and heat transfer characteristics were obtained from experiments by test of thermal performance to formulate temperature gradient about amount of heat transfer of PCM content using the Fourier's thermal equation. The study results can be used in the application of PCM in buildings and expected effect of air conditioning and heating energy.

Study on PCM Applied Thermal Storage Wall System to Reduce Cooling Energy (냉방에너지 저감을 위한 PCM적용 축열벽 시스템 연구)

  • Lee, Kyuyoung;Ryu, Ri;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.6
    • /
    • pp.247-256
    • /
    • 2014
  • The regulations to reduce energy consumption and carbon dioxide emission in building sectors are being developed and promoted all over the world. However, in Korea, as balcony extension of the apartments has been legally allowed, it became prevalent and resulted in excessive energy consumption. This study derived the possibility of PCM application to the thermal storage wall system through theoretical consideration and investigated the problems occurring when the balcony space has been extended to the diverted space. In addition, this study aims at the possibility of verifying the installation and confirming the cooling energy reduction effect, by conducting measuring tests with the actual installation of PCM applied thermal storage wall system. As a result of theoretical consideration, it is determined that the disadvantages with the existing thermal storage wall system can be complemented by applying PCM, and this study suggests the PCM applied Thermal Storage Wall System. The study was conducted on 1/6 of a miniature inner room of a domestic apartment with 84 $m^2$ of exclusive area. From the results of actual measurements, it is confirmed that the balcony extension structure can gain 11.3% of more calories than the existing balcony structure, resulting in the increase in cooling energy usage. It is determined that the installation of the PCM applied Thermal Storage Wall System may gain 25.2% of less calories to reduce cooling energy usage.

Performance Simulation and Analysis of the Solar Thermal Storage System Using Heat Pipe (히트파이프를 사용한 태양열 축열시스템의 성능모사 및 해석)

  • Jung, Eui-Guk;Boo, Joon-Hong;Kim, Jong-Kyu;Kang, Yong-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.80-85
    • /
    • 2009
  • Mathematical modeling and performance simulation results were shown for the solar thermal storage system which used heat pipe. The thermal storage system was composed of thermal storage tank and charging/discharging heat exchanger with one by the heat pipes. Heat pipe heat exchanger was attached to system, and could carry out charging and discharging to thermal storage tank at the same time. Height of the thermal storage tank was 600 mm, and that of the charging/discharging heat exchanger was 400 mm. Length of the heat pipe was the same as the total height of thermal storage system, and outer and inner diameter were 25.4 mm(O.D.) and 21.4 mm(I.D.) respectively. Diameter of the circular was 43 mm(O.D.), and fin geometries were considered as the design parameters. High temperature phase change material(PCM), $KNO_3$ and low temperature PCM, $LINO_3$ were charged to storage tank to adjust working temperature. Total size of thermal storage system able to get heat capacity more than 500 kW was calculated and the results were shown in this study. Number of heat pipe was required more than maximum 500, and total length of thermal storage system was calculated to the more than maximum 3 m at various condition.

  • PDF

A Study on Formation of Slurry Ice by using the Reversing Flow in a Bundle of Tube (역전 유동층을 이용한 관군 내에서의 슬러리아이스 생성에 관한 연구)

  • Oh, Cheol;Choi, Young-Gyu
    • Journal of Navigation and Port Research
    • /
    • v.35 no.5
    • /
    • pp.365-370
    • /
    • 2011
  • The ice-thermal energy storage cooling system has been applied to relief a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type system is one kind of ice-thermal storage cooling system utilizing cheaper off-peak electricity. This study is experimented to observe an influence of experimental conditions on production characteristics of slurry ice by using reversing flow, which is putting reversing material into test section to disturb ice adhesion. At this experiment, poly propylene ball of dimeter 10 mm was used as reversing material, and ethylene glycol-water solution of 20wt% concentration was used as flow material. The experimental apparatus was constructed of the slurry ice making and storage tank(test section), the brine tank, pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter, data logger for fluid temperature measuring. The experiments were carried out under various conditions, with volumetric flow rate, ball filling rate and air filling rate.

Heat Transfer Characteristics of High Temperature molten salt storage for Solar Thermal Power Generation (태양열 발전에서 태양열에너지 수송을 위한 고온 축열 물질의 열절달 특성)

  • Mao, Aiming;Kim, Ki-Man;Kang, Yong-Heack;Han, Gui-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.190-193
    • /
    • 2008
  • The heat transfer characteristics of molten salt storage system for the solar thermal power generation were investigated. Temperature profiles and the heat transfer coefficients during the storage and discharge stage were obtained with the steam as the heat transfer fluid. Two kinds of inorganic salt were employed as the storage materials and coil type of heat exchanger were installed in both tanks to provide the heat transfer surfaces during the storage and discharge stage. The effects of steam flow rates, flow direction of steam in the storage tank and the initial temperature of storage and discharge tank on the heat transfer were tested.

  • PDF

The Study on Improvement in Subcooling of TMA Clathrate for PCM in Ice Storage System (빙축열시스템 PCM용 TMA-포접화합물의 과냉도 개선에 대한 연구)

  • Kim, J.H.;Chung, N.K.;Kim, C.O.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1663-1666
    • /
    • 2003
  • TMA clathrate that is used by PCM of ice storage system in this research creates hydrate crystallization at higher temperature than pure water, and application is expected as PCM because having comparative big dormant temperature without phase separation phenomenon. In case this research uses TMA clathrate by PCM, choose admixture by purpose to control or remove subcooling of TMA clathrate and evaluated experimentally. Subcooling is improved and can expect contraction of freezing machine running time and increase of coefficient of performance as that add admixture to TMA clathrate conclusively. Also, may supply thermal storage system that apply low temperature potential heat thermal storage material that subcooling is improved more extensively laying stress on medium size building and small size building, can expect allowance through localization of ice storage system.

  • PDF

Development of Preheating Module for Domestic Heating Facility, Using PCM(Phase Change Material) Thermal Storage Equipment (상변화물질(PCM)을 이용한 가정용 보일러의 잠열축열식 예열모듈 개발)

  • Son, Chul-Min;Kim, Tae-Wook;Na, Kyu-Dong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.3
    • /
    • pp.163-169
    • /
    • 2009
  • A preheating module for domestic heating facility will increase a energy efficiency. That collects the wasted heat of exhaust gas and saves the energy. So a heating load is decreased because of a preheating that has a heating energy. Using of a preheating module, a boiler can reduce frequent operation of a burner. So it is increased persistence, decreased discharging noxious gases. Therefore we will intend to develop a heating facility that is a convenient system for the saving energy.

  • PDF

Experiment and Property Study of Ondol Panel Based on Phase Change Material (PCM을 이용한 온돌패널의 실험 및 특성연구)

  • Yoon, Doo-Han;Choi, Bong-Su;Hong, Hi-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.122-125
    • /
    • 2006
  • This paper deals with the Ondol, Korean under-floor heating system using latent heat storage materials. It has been recognized that the heating system using the latent heat storage materials are economically efficient and comfortable. For the comparison and analysis to the data of the existing experiment, a repetitive experiment makes sure the ability of Ondol panel.

  • PDF

An Experimental Study on the Heat Storage Properties of Phase Change Material Using Paraffin Sheets in Building (파라핀을 이용한 건축용 시트형 잠열축열재의 축열특성에 관한 실험적 연구)

  • Ko, Jin-Soo;Kim, Byung-Yun;Park, Sung-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.5
    • /
    • pp.435-441
    • /
    • 2011
  • The life cycle assessment on greenhouse gas emission of reinforced concrete buildings shows that more than 70 percent of greenhouse gas that is discharged by a building is discharged in the building maintenance stage, including cooling and heating. To reduce the greenhouse gas emission, maintenance planning to minimize the energy consumption is necessary in the design stage. In this paper, two heat storage rooms are tested to save the air cooling energy of the buildings. The specimens are essentially identical, except that chamber A contained paraffin sheets as the finishing material, while the other, chamber B, served as a control. The test results show that chamber A with the paraffin sheets exhibited less temperature change than chamber B without the sheets when temperature was increased outside of the specimens. The heating energy was probably consumed in the phase change of the paraffin sheets, which can be useful for reducing energy consumption related to air cooling during the summer.