• Title/Summary/Keyword: 축소모형실험장치

Search Result 45, Processing Time 0.027 seconds

Validity Analysis of Scale Model Experiment for Wetting Agent Performance Evaluation (침윤소화약제 성능평가를 위한 축소실험의 타당성 분석)

  • Kim, Nam-Kyun;Lim, Kyung-Bum;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.14-19
    • /
    • 2014
  • A current standard exist only on the surface tension in the current domestic wetting agent technology standards, so it is difficult to the performance evaluation of the wetting agent through the standard. So this study presents the optimized performance evaluation methods by scale model experimental equipment in order to present techniques for performance evaluation of wetting agents. The purpose of this study is to investigate validity of experimental results of the self-designed scale model experiment equipment by a comparative analysis of experimental results of the NFPA 18 experiment and the experiment using the self-designed scale model experiment equipment. As a result of a comparative analysis of experimental results of the NFPA 18 experiment that evaluate only the permeation performance on the contton and the experiment using the self-designed scale model experiment equipment that evaluate the permeation performance and fire extinguishing performance on wood flour, the discrimination of the permeation performance was confirmed in both the NFPA 18 experiment and the self-designed scale model experiment equipment. And a result of self-designed experiment equipment have clear discriminatory more than NFPA 18 by internal temperature measurement using the thermocouples.

Analysis of Hydraulic Similarity at Surcharged Square Manhole (과부하 사각형 맨홀에서의 수리학적 상사성 분석)

  • Kim, Jung-Soo;Yoon, Young-Noah;Han, Chyung-Such;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.510-514
    • /
    • 2008
  • 우수 관거 시스템에서 맨홀의 설치 시 연결관 내부와 맨홀의 내부는 여러 가지 수리학적 조건이 다르므로 수두손실의 발생이 필연적일 수밖에 없다. 현재 계획 또는 설계단계에서 수행되고 있는 관거 시설의 수리계산에는 연결관 내에서의 마찰손실만을 고려하여 설계를 수행하고 있으며, 맨홀에서의 수두 손실은 거의 대부분 고려되지 않고 있다. 단지 맨홀에서의 수두손실을 저감하기 위하여 하수도시설기준(환경부, 2005)상의 단차 및 인버트 규정만 있을 뿐, 우수 관거 설계에 직접적으로 필요한 적절한 맨홀의 손실계수가 제시되지 않고 있는 실정이다. 국외에서는 축소 수리 모형을 이용한 실험과 수치해석 기법 등을 이용하여 맨홀에서의 손실계수를 산정하는 연구가 꾸준히 진행되어 왔으나 국내에서는 맨홀의 손실계수 산정에 관한 연구가 미흡한 실정이며, 더욱이 맨홀에서의 손실계수 산정을 위한 상사성 적용에 관한 연구는 전무한 실정이다. 그러므로 본 연구에서는 맨홀의 축척 변화에 따른 손실계수의 변화를 분석하기 위하여 하수도시설기준(환경부, 2005)의 특 1호(사각형) 맨홀을 각각 1/2과 1/5로 축소 제작하고, 수리실험 장치를 제작하였다. Froude 상사 법칙을 적용하여 1/2의 축소 모형의 실험 조건을 1/5 축소 모형의 값으로 환산하였으며, 각 축소 모형에 대한 수리 실험을 실시하였다. 과부하된 맨홀의 손실계수를 예측하는데 Froude 상사법칙의 사용 가능성을 확인 하였으며, 1/2 축소 모형과 1/5 축소 모형에서 산정된 손실계수 값이 0.45로 일치하고 있으므로 우수 관거 시스템의 맨홀 설계 시, 축소 수리 모형실험에서 산정된 손실계수의 직접적인 적용이 가능하다고 판단된다.

  • PDF

Shaking Table Tests of a 1/4-Scaled Steel Frame with Base Isolators (1/4축소 철골구조물을 이용한 건물 기초분리장치의 진동대실험)

  • 송영훈;김진구
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.39-48
    • /
    • 1997
  • New form of base isolators made of steel spring coated with both natural and artficial rubber were manufactured and tested for material properties. Shaking table experiments were performed using a model structure attached with the bearings. The model structure used in the test is a 1/4 scaled steel structure, and earthquake records were used to check the lateral and vertical stability and effectiveness of the isolators. According to the results all three types of isolators turned out to be effective in reducing the acceleration induced by the earthquake vibration.

  • PDF

침윤소화약제 특성 판단을 위한 축소모형실험

  • Kim, Nam-Gyun;Im, Gyeong-Beom;Lee, Dong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.45-46
    • /
    • 2013
  • 본 연구는 침윤소화약제의 소화성능평가를 위해 자체제작 축소모형 실험장치를 이용하여 목재를 대상으로 실험을 진행하였다. 물과 7종의 침윤소화약제를 소화용수로 하여 성능평가 실험을 진행함으로써 물과 침윤소화약제의 명확한 변별력을 확인하고자 하였다. 실험결과 침윤소화 약제의 경우 7종 모두 유사한 소화 성능 패턴을 나타내는 것을 확인하였으며 동일 조건에서 물의 경우 재발화가 발생함으로써 명확한 변별력을 확인하였다.

  • PDF

Shaking Table Tests of Base-Isolated Steel Frame (지진격리된 철골구조물의 진동대 실험)

  • 윤정방
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.136-143
    • /
    • 1997
  • 본 연구에서는 철골구조물을 대상으로 지진격리(Base-Isolation)를 사용하였을 때의 진동감소 효과를 분석하기 위하여 지진하중에 대한 진동대 실험을 수행하였다. 실험 대상구조물은 $\frac{1}{4}$축소모형의 3층 철골구조물이며, 입력지진은 여러 계측기록과 UBC 설계스펙트럼으로부터 3가지 지반조건에 대하여 작성한 인공지진기록을 사용하였다. 축소 실험모형은 기초가 고정된 일반적인 철골구조물과 적층고무받침(Laminated Rubber Bearing) 형식의 지진격리장치(Base Isolator)를 사용한 구조물을 동시에 설치하여 그 지진응답을 비교 관찰하였다. 대부분의 하중하에서 지진격리장치가 사용된 철골구조물의 경우에 지진응답이 현저히 감소하는 것을 알 수 있으나, 장주기파의 성분이 강한 지반운동에 대해서는 오히려 지진응답이 증가하였다. 그러나 여러 지반조건에 대하여 UBC 시방서에서 규정한 설계하중에 대하여는 진동감소효과가 우수함을 보인다.

  • PDF

Shaking Table Test of Isolated EDG Model (면진된 모형 비상디젤발전기의 지진응답 실험)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.33-42
    • /
    • 2007
  • In this study, for research on an improvement of the seismic safety of an EDG system, a small scale EDG system was manufactured. For the isolation system, the Coil Spring-Viscous Damper systems were selected. For the shaking table test, 3 kinds of seismic motions were selected which had different frequency contents. In this study, the isolation effects were different and they depended on the input seismic motion. In the case of an NRC earthquake which had low fiequency contents, the isolation effects of the horizontal direction were 20%. But for the seismic motions which had high fiequency contents, the isolation effects were $50{\sim}70%$. In the case of the vertical direction, poor isolation effects were observed. It was because the design properties and the real properties of the isolation system were a little different.

A Study on the Model Experiment for Smoke Flow in Road Tunnel Fire (도로터널 화재발생시 연기유동에 관한 축소모형실험 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon;Kang, Se-Gu;Ahn, Kyung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.2
    • /
    • pp.141-149
    • /
    • 2004
  • In this study, smoke movement in tunnel fire with natural and longitudinal ventilation systems has been investigated. Reduced-scale experiments were carried out under the Froude scaling using 14.55kW fire source with a wick and experimental data is obtained with 1/18 model tunnel test. Temperature profiles were measured under the ceiling and vertical direction along the center of the tunnel and poisonous gas was measured at emergency exit point. The results show that refuge time for 225m intervals of emergency exit in case of natural ventilation systems is 256 seconds and critical velocity for sufficient back-layer prevention is 2.8m/s for fire strength of 20MW.

  • PDF

Removal Efficiency and Applicability Analysis of Suspended Solids in Nonpoint Source Reduction Equipment (비점오염원 저감장치의 부유물질 제거효율 및 적용성 분석)

  • Jang, Suk-Hwan;Lee, Jae-Gyeong;Lee, Hae-Gwang;Oh, Ji Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.245-245
    • /
    • 2018
  • 최근 도시화 및 산업화의 발달로 불투수면적이 증가함에 따라 건기 시 토지 표면에 축적된 오염물질이 강우유출수와 함께 하천으로 유출되는 등 수질오염의 가중과 불특정 지역에서 발생하는 비점오염원의 집중관리가 필요한 실정이다. 우리나라는 환경기초시설 등의 건설로 점오염원 관리는 강화되었지만, 비점오염원의 부하량은 점차 증가되고 있는 추세이며, 환경부 및 관계부처에서는 비점오염관리를 위한 여러 정책을 추진 중에 있다. 국내에서 사용하고 있는 비점오염저감장치는 자연형 시설과 장치형 시설로 구분되는데, 이 중 장치형 시설은 필터를 사용하여 비점오염저감의 효율성을 증가시키지만, 필터를 사용함으로써 유지관리 및 경제적인 측면에서 매우 불리하다. 이에 본 연구에서는 필터가 없는 장치형 시설을 고안하여 자연 순환기능을 최대한 유지하고, 오염물질을 최적으로 제거할 수 있는 방안을 마련하고자 수리실험을 통해 비점오염원의 제거효율을 분석하였다. 수리학적 상사법칙에 따라 원형대비 1/3축소모형과 2가지의 원형모형에 대해 총 3가지 모형에 대해 환경부에서 고시한 비점오염저감장치 기준을 뛰어넘는 유역면적, 강우강도 및 부유물질의 양으로 실험을 진행하였다. 실험결과는 유입수 농도에 대한 유출수의 농도로 계산하였으며, 장치에서 유출 직후 5분 간격으로 채취한 후, 수질공정시험법을 참고하여 부유물질에 대한 실험 중 하나인 유리섬유여과방법을 이용해 실험 결과를 도출하였다. 실험 결과, 본 연구에서 고안한 장치형 시설은 필터를 사용하지 않음에도 불구하고 환경부 기준인 부유물질 제거효율 80%이상을 만족한 것으로 나타나 현재 사용하고 있는 장치형 시설보다 유지관리 및 경제성 등이 우수할 것으로 기대된다.

  • PDF

A Study on Eccentric Joint of K-type Gusset-Tube Connection (K형 가셋트-강관 접합부의 편심접합에 관한 연구)

  • Kim, Woo Bum;Kim, Kap Sun;Chung, Soo Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.1
    • /
    • pp.81-89
    • /
    • 2001
  • Experiments and the parametric based on finite element model were conducted to investigate the behavior and strength of a gussettube connection concerned with eccentricity and selenderness ratio. Because of limitations in loading capacity the specimens were fabricated with 1/3 scale of full size. Of primary interest here are the ultimate strength of connections having eccentricity caused by lateral loads. As a result the effect of eccentricity on the buckling strength was examined and the validity of the finite element model adopted in this study was verified through comparing with test results.

  • PDF

A Study on the Effect of Underground Openings on the Stability of Surface Structures Using Scaled Model Tests (지하 채굴적이 지표 구조물의 안정성에 미치는 영향에 관한 모형실험 연구)

  • 김종우;전석원;서영호
    • Tunnel and Underground Space
    • /
    • v.14 no.1
    • /
    • pp.43-53
    • /
    • 2004
  • In this study, scaled-model tests were performed to investigate the effect of underground openings on the stability of surface structure around the abandoned coal mine areas. Four types of test models which had respectively different depths of openings and different ground reinforcement conditions were introduced, where the modelling materials were the mixture of sand, plaster and water. The model with deep openings were turned out more stable to the structure than the model with shallow ones, because the crack-initiating pressure of the former was 2.5 times as much as that of the latter. The models with ground reinforcement were also fumed out more stable than the model without reinforcement, because the crack-initiating pressure of the former was 2.4 times as much as that of the latter. Subsidence profiles were analysed to find the characteristics of slope and curvature, and the model with large reinforcement were turned out the most stable.