• Title/Summary/Keyword: 축교정

Search Result 98, Processing Time 0.026 seconds

Tracking Algorithm For Golf Swing Using the Information of Pixels and Movements (화소 및 이동 정보를 이용한 골프 스윙 궤도 추적 알고리즘)

  • Lee, Hong, Ro;Hwang, Chi-Jung
    • The KIPS Transactions:PartB
    • /
    • v.12B no.5 s.101
    • /
    • pp.561-566
    • /
    • 2005
  • This paper presents a visual tracking algorithm for the golf swing motion analysis by using the information of the pixels of video frames and movement of the golf club to solve the problem fixed center point in model based tracking method. The model based tracking method use the polynomial function for trajectory displaying of upswing and downswing. Therefore it is under the hypothesis of the no movement of the center of gravity so this method is not for the amateurs. we proposed method using the information of pixel and movement, we first detected the motion by using the information of pixel in the frames in golf swing motion. Then we extracted the club head and hand by a properties of club shaft that consist of the parallel line and the moved location of club in up-swing and down-swing. In addition, we can extract the center point of user by tracking center point of the line between center of head and both foots. And we made an experiment with data that movement of center point is big. Finally, we can track the real trajectory of club head, hand and center point by using proposed tracking algorithm.

Construction of Low Magnetic Standard System using a Multi-layer Solenoid with Single-current (단전류-다층 솔레노이드 방법을 사용한 저자장 표준시스템 제작)

  • 박포규;김영균
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.1
    • /
    • pp.38-44
    • /
    • 2001
  • The magnetic field standard below 1 mT with the resolution of 0.26 nT has been established. Earth magnetic field (EMF) is compensated automatically down to 0.1 nT/10 min. by a closed feedback system with Cs optical pumping magnetometer and 3-axis Helmholtz coils in nonmagnetic facilities. A multi-layer precision solenoid with the optimized single-current method generates the uniform magnetic field better than 1.0$\times$10$\^$-7/ within $\pm$ 1 cm region at its center. The coil constant of solenoid determined from Helium optical pumping magnetometer is 1.231 058 9 mT/A, and temperature coefficient is 0.38 nT/$\^{C}$. This standard system is used for calibration of low field magnetometers and testing relates to low field.

  • PDF

Analysis Of Childcare Policy From a Caring Democracy Perspective ('돌봄민주주의' 관점에서 본 보육정책)

  • Baek, Kyungheun;Song, Dayoung;Jang, Soojung
    • Korean Journal of Family Social Work
    • /
    • no.57
    • /
    • pp.183-215
    • /
    • 2017
  • This study analyzes Korean childcare policy from a caring democracy perspective by using the normative policy analysis method. In the midst of emergent new social risks engendered by low fertility and aging population, feminist scholars proposed a transformative paradigm shift from economic growth to caring oriented development on a macro scale but researches on how this grand principle can be reflected into each policy have hardly been discussed. Thus, this study intends to contribute to such policy-driven discussion by analysing childcare policy on the basis of three normative values of freedom, equality and justice re-interpreted by caring democracy theory. Following are key findings. First, childcare policy does not guarantee public value and social solidarity due to the limitations of free choice from the perspective of freedom. Secondly, gender and class stratification has been worsened in a multiple and more complicated way by adding generational and racial dimensions to the existing gender inequality and vicious circulation of private care is observed from equality perspective. Thirdly, structural inequality aggravated injustice previously accumulated in the past rather than providing flat ground by adjustment.

Formulation of a reference coordinate system of three-dimensional head & neck images: Part II. Reproducibility of the horizontal reference plane and midsagittal plane (3차원 두부영상의 기준좌표계 설정을 위한 연구: II부 수평기준면과 정중시상면의 재현성)

  • Park, Jae-Woo;Kim, Nam-Kug;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.475-484
    • /
    • 2005
  • This study was performed to investigate the reproducibility of the horizontal and midsagittal planes, and to suggest a stable coordinate system for three-dimensional (3D) cephalometric analysis. Eighteen CT scans were taken and the coordinate system was established using 7 reference points marked by a volume model, with no more than 4 points on the same plane. The 3D landmarks were selected on V works (Cybermed Inc., Seoul, Korea), then exported to V surgery (Cybermed Inc., Seoul, Korea) to calculate the coordinate values. All the landmarks were taken twice with a lapse of 2 weeks. The horizontal and midsagittal planes were constructed and its reproducibility was evaluated. There was no significant difference in the reproducibility of the horizontal reference planes, But, FH planes were more reproducible than other horizontal planes. FH planes showed no difference between the planes constructed with 3 out of 4 points. The angle of intersection made by 2 FH planes, composed of both Po and one Or showed less than $1^{\circ}$ difference. This was identical when 2 FH planes were composed of both Or and one Po. But, the latter cases showed a significantly smaller error. The reproducibility of the midsagittal plane was reliable with an error range of 0.61 to $1.93^{\circ}$ except for 5 establishments (FMS-Nc, Na-Rh, Na-ANS, Rh-ANS, and FR-PNS). The 3D coordinate system may be constructed with 3 planes; the horizontal plane constructed by both Po and right Or; the midsagittal plane perpendicular to the horizontal plane, including the midpoint of the Foramen Spinosum and Nc; and the coronal plane perpendicular to the horizontal and midsagittal planes, including point clinoidale, or sella, or PNS.

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF

Cause Analysis in Decrease of Body Stability According to The Induced Astigmatic Blur (유발된 난시성 흐림에 의한 신체 안정성 감소의 원인분석)

  • Kim, Sang-Yeob;Yu, Dong-Sik;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.259-264
    • /
    • 2016
  • Purpose: To establish the cause of decrease in body stability and to analyze the effects on sensory organs maintaining static balance according to the induced astigmatic blur. Methods: Twenty subjects (10 males, 10 females; mean age, $23.40{\pm}2.70years$) were participated in this study. To induce myopic simple astigmatism, the axis directions of cylindrical lenses were placed $180^{\circ}$ on both eyes (with-the-rule), $90^{\circ}$ on both eyes (against-the-rule), and $45^{\circ}$ on both eyes (oblique). Cylindrical lenses of +0.50, +1.00, +1.50, +2.00, +3.00, +4.00, and +5.00 D were used to increase astigmatic blur in each astigmatism types. General stability (ST) and sway power (SP) in frequencies by each sensory organs were analyzed using the TETRAX biofeedback system. Results: ST in the all astigmatism types were raised with increase of astigmatic blur compared to full corrected condition, but a significant difference only showed in the induced oblique astigmatism. According to the results of correlation analysis between ST and SP in the each frequencies with increase of astigmatic blur, the causes of increased ST in the induced oblique astigmatism showed to have a high correlation in order of somatosensory system (high-medium frequency), central nervous system (high frequency), peripheral vestibular system (low-medium frequency), and visual system (low frequency). Conclusions: The visual information by uncorrected oblique astigmatism may disturb the normal functions of all sensory organs maintaining body balance, consequently, the body stability can be reduced. Therefore, optimal correction of astigmatism can play an important role for reducing the instability of body balance.

Results of Surgical Treatment of Patella Dislocation (슬개골 탈구의 수술적 치료 결과)

  • Kim, Hui Taek;Cho, Yoon Jae
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.2
    • /
    • pp.134-141
    • /
    • 2021
  • Purpose: Patellar dislocations have a range of causes. This study examined the results of treatment aimed at balancing soft tissues around the patella. Materials and Methods: Thirty-two patellar dislocations in 28 patients (21 females and seven males) were examined. The mean patient age at the time of surgery was 11.5 years, and the mean follow-up period was 4.6 years. Dislocations were 19 chronic, six habitual, six congenital, and one acute. Soft tissue balancing surgery included lateral capsular release, medial capsular plication, and inferolateral transfer of the vastus medialis obliquus. Medial transfer of the patellar tendon, partial strip of the rectus femoris and patella tendon, and distal femoral osteotomy were also performed selectively. The preoperative Q angle, femoral anteversion angle, tibial external rotation angle, tibial tubercle-trochlear groove distance (TT-TG distance), mechanical femoral-tibial angle, and femoral trochlear dysplasia according to Dejour were measured, and the pre- and postoperative Lysholm-Tegner scores were used to analyze the clinical results. Results: The mean preoperative Q angle, TT-TG distance, femoral anteversion angle, tibial external rotation angle, mechanical femoraltibia angle, and Lysholm-Tegner score were 9.3°, 15.5 mm, 25.6°, 30.4°, 3.0°, and 75.8, respectively. Eleven patients had systemic ligament laxity with a Beighton score of five or more. Twenty-two patients had femoral trochlear dysplasia: four type A (3 patients), 16 type B (15 patients), one type C (1 patient), and four type D (3 patients). Of the 32 cases, 28 were corrected successfully by the first operation. Of four cases of postoperative subluxation, three were corrected by the second operation, and one of them was corrected after a third operation. The last patient is currently being followed-up. The mean Lysholm-Tegner score improved to 85.6 after the operation. Conclusion: Correcting all the causes of patella dislocation simultaneously is difficult. Nevertheless, satisfactory outcomes were obtained with soft tissue balancing surgery around the patella and a corrective osteotomy for an abnormal mechanical axis of the femur-tibia and torsion.

Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws (고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구)

  • Kim Jeung-kee;Choi Young-Min;Lee Hyung-Sik;Hur Won-Joo
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.237-244
    • /
    • 1996
  • Purpose : The accurate dosimetry of independent collimator equipped for 6MV and 15MV X-ray beam was investigated to search for the optimal correction factor. Materials and Methods : The field size factors, beam quality and dose distribution were measured by using 6MV, 15MV X-ray Field size factors were measured from $3{\times}3cm^2$ to $35{\times}35cm^2$ by using 0.6cc ion chamber (NE 2571) at Dmax. Beam qualities were measured at different field sizes, off-axis distances and depths. Isodose distributions at different off-axis distance using $10\times10cm^2$ field were also investigated and compared with symmetric field. Result: 1) Relative field size factors was different along lateral distance with maximum changes in $3.1\%$ for 6MV and $5\%$ for 15MV. But the field size factors of asymmetric fields were identical to the modified central-axis values in symmetric field, which corrected by off-axis ratio at Dmax. 2) The HVL and PDD was decreased by increasing off-axis distance. PDD was also decreased by increasing depth For field size more than $5{\times}cm^2$ and depth less than 15cm, PDD of asymmetric field differs from that of symmetric one ($0.5\~2\%$ for 6MV and $0.4\~1.4\%$ for 15MV). 3) The measured isodose curves demonstrate divergence effects and reduced doses adjacent to the edge close to the flattening filter center was also observed. Conclusion . When asymmetric collimator is used, calculation of MU must be corrected with off-axis and PDD with a caution of underdose in central axis.

  • PDF

The three dimensional measuring system for ELF magnetic fields with the multiturn loop-type sensors (멀티턴 루우프형 센서를 이용한 3차원 ELF 자장측정계)

  • Lee, Bok-Hee;Lee, Jeong-Gee;Kil, Gyung-Suk;Ahn, Chang-Hwan;Park, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.29-36
    • /
    • 1996
  • With the three dimensional magnetic field measuring system dealt with in this paper, accurate measurements and analyses of extremely low frequency(ELF) magnetic fields caused by starting and/or operating electric devices and power installations can be conducted. To obtain high performance for lower frequency and spatial components without any distortion, the measuring system is designed as three dimensionally including the multiturn loop-type magnetic field sensors, differential amplifiers and active integrators. As the results of calibration experiments, the frequency response characteristics of the measuring system range from 8[Hz] to about 53[kHz] for each direction of x, y, z axes, and the response sensitivities are 9.54, 9.21, $10.89[mV/{\mu}T]$, respectively. The actual survey experiments by using an oscillating impulse current generator confirm a reliability of the proposed measuring system. Also, through the other experiments by using small-sized induction motors, the magnetic field intensities when starting and steady-state operating mark 15.8, $8.61[{\mu}T]$ as maximum value, respectively. And those intensities decrease steeply according as the measuring distance increases.

  • PDF

A Study on the Branch Composition of an Optimum Polarization Diversity by Considering XPD in Indoor Radio Environments (실내무선 환경에서 XPD를 고려한 최적편파 다이버시티의 브랜치 구성에 관한 연구)

  • 하덕호;이주현;윤영석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.302-311
    • /
    • 1999
  • In this paper, in order to suggest an optimal polarization diversity composition method in indoor radio wave propagation environments, the variation of the cross polarization discrimination(XPD) was theoretically analyzed by a computer simulation and compared to the actual measured data. From the results, it can be seen that the cross polarization discrimination of the case, a circularly polarized antenna was used at the transmitting end as well as the vertical and horizontal polarized antenna branches were used at receiving end (CV-CH), is lower than that of the case, horizontal polarized antenna at the transmitting end as well as the horizontal and vertical polarized antenna branches at the receiving end(HH-HV), and that of the case, vertical polarized antenna at the transmitting end as well as the vertical and horizontal polarized antenna branches at the receiving end(VV-VH). In this paper, to get more effective CV-CH polarization diversity composition, the amount of cross polarization discrimination values at the signals received by horizontal polarized antenna is compensated and the polarization diversity effect through the cumulative probability distribution is estimated. From the evaluation results, it was found that the polarization diversity effect was better at the compensated case than at the uncompensated case. On the other hand, it can be known that the polarization diversity effect is getting better as the cross polarization discrimination values are getting lower, and also be known that the effect can be improved if a transmitting antenna is composed of the ellipse polarized antenna by adjusting the axial ratio of the circularly polarized antenna and, a receiving antenna is made up of the vertical and horizontal polarized antenna branches.