• Title/Summary/Keyword: 추함

Search Result 6,740, Processing Time 0.04 seconds

The Clinical Significance of ${\gamma}{\delta}$ T lymphocytes in patients with pleural tuberculosis (결핵환자에서 말초혈액과 흉막액내 ${\gamma}{\delta}$ T 림프구의 의의)

  • Song, Kwang Seon;Shin, Kye Chul;Kim, Do Hun;Hong, Ae Ra;Kim, Hee Seon;Yong, Suk Joong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.44-51
    • /
    • 1997
  • Background : The changes of the composition in the T-lymphocyte are important as an immunological abnormality in the pathogenesis of tuberculosis. Previously, the second type of TCR dimer(${\gamma}{\delta}$ T lymphocyte) that did not express CD4 or CD8 molecules was found. In other reports the presence of this type of lymphocytes was increased in the initial stage of tuberculous infections. Method : To determine whether there are some differences in the T-lymphocyte subsets in the peripheral blood or pleural effusion between pleural tuberculosis and other pleurisy. Thirty patients with pleural effusion among the forty-nine patients were examined T-lymphocyte subset analysis(CD4+T-cell,CD8+ T-cell,${\gamma}{\delta}$ T-lymphocytes) with anti- Leu4, anti-Leu3a, anti-Lea2a, anti HLA-DR and anti-TCR-${\gamma}{\delta}$-1(Becton & Dickinson Co.). Results : The average age of the patients was 50 years old(17-81year). There were 33 males and 16 female patients. Patiensts with tuberculosis are 30cases(tuberculous pleurisy 15), lung cancer 12cases(malignant effusion 9) and pneumonia 7cases(parapneumonic effusion 6cases) In T lymphocyte subsets of pleural effusion, helper T lymphocyte(54.6 + 13.8 %) of tuberculous pleurisy was higher than that(36.2 + 25.3 %) of non-tuberculous pleurisy(p=0.04). The peripheral blood ${\gamma}{\delta}$ T-lymphocytes in tuberculousis was insignificantly higher than non-tuberculous patients(p= 0.24). The peripheral blood ${\gamma}{\delta}$ T-lymphocytes and pleural ${\gamma}{\delta}$ T-Iymphocytes in tuberculous pleurisy was insignificantly higher than in non-tuberculous pleurisy(p= 0.16, p= 0.12). Conclusion : The percentage of -${\gamma}{\delta}$ T lymphocytes among the total T-lymphocytes is not significantly increased in the peripheral blood or pleural effusion of the pleural tuberculosis. ${\gamma}{\delta}$ T lymphocytes is less useful as a diagnostic method of pleural tuberculosis.

  • PDF

The Evaluation of Hybrid-Volumetric Modulated Arc Therapy for Lung Cancer Radiation Therapy (폐암 방사선 치료 시 Hybrid-Volumetric Modulated Arc Therapy의 유용성 평가)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.19-26
    • /
    • 2017
  • Objectives: In the Lung, the VMAT rotates continuously and examines radiation. That increases the low doses to normal lung. Due to that, the incidence of radiation pneumonia among radiation side effects may increase. The cause of radiation pneumonia is the lower dose area of the lungs. The H-VMAT was applied to patients who applied to reduce radiation in the lower doses of the lungs. We wanted to assess the usefulness of the H-VMAT by comparing the radiation doses to the low dose areas of the lungs and the normal organs. Materials and Methods: A total of 26 patients who applied for a H-VMAT procedure were applied to the patient. The prescription dose applied to total dose 44 Gy from 22 divisions. For each patient, a plan was implemented with Conventional RT, VMAT and H-VMAT. Conventional RT was carried out in four to five fields each, considering the size, location, shape, and location of the PTV. In the case of a VMAT plan, the two Half ARC, three Half ARC method and the two Full ARC were planned. The H-VMAT was planned by adding two Static fields in the VMAT, taking into account the dose of the lung and the tolerance dose of the organs. Results: In the NSCLC, the lung doses $V_5$ and $V_{10}$ of the lungs except for the treatment plan volume were the lowest with $55.40{\pm}13.39%$ and $32.05{\pm}11.37%$ of H-VMAT. And, in the SCLC, the lung doses of V5 and V10 were the lowest at $64.32{\pm}16.15%$ and $35.50{\pm}9.91%$, respectively. The spinal dose of VMAT in NSCLC was $21.15{\pm}4.02Gy$, which was 7.94 Gy lower than other treatment methods. The lowest spinal dose was delivered at $19.72{\pm}1.82Gy$ for SCLC. The mean dose delivered to the esophagus was also $17.44{\pm}2.04Gy$ and $17.84{\pm}9.20Gy$ in SCLC and NSCLC, respectively. Conclusion: When comparing the value of the surrounding normal organ dose, the VMAT showed that less doses were transmitted from the heart, esophagus and spinal cord than the rest of the treatment plan. However, it was similar to VMAT in normal organs except for the spinal cord. VMAT has increased doses of some normal organs but did not exceed the tolerance dose. It showed a low value in $V_5$, $V_{10}$. When comparing Conventional RT, VMAT, and H-VMAT, If the dose to the heart, esophagus and spinal cord is lower than the tolerance dose, it is thought to reduce the incidence of radiation pneumonia by applying H-VMAT that show the benefits of low doses of the lungs.

  • PDF

Study on the Effect of Deep Fertilization on Paddy Field - Efficiency of Ball Complex Fertilizer Mixed with Zeolite - (수도(水稻)에 대(對)한 심층추비효과(深層追肥効果)에 관(關)한 연구(硏究) - Zeolite 첨가(添加) Ball complex 비료(肥料)의 비효(肥効) -)

  • Kim, Tai-Soon;U., Zang-Kual
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.10 no.1
    • /
    • pp.61-67
    • /
    • 1977
  • A study was conducted in order to compare the topdressing method of the conventional fertilizers as control and the deep application method of the ball complex fertilizer newly developed. The ball complex fertilizer consisted of 5% of nitrogen, 5% of phosphorus, and 7% of potassium. Basal application of nitrogen for the rice plant was the same for both control plots and ball complex plots. One ball complex fertilizer per four hills was applied at depth of 12~13cm 35days before heading stage while control plot received three times topdressing at different growth stages as usual practice. The results obtained were as follows. 1. The ball complex fertilizer applied in the soil was continuously utilized by the rice plants until harvest time while nitrogen and potassium uptake of control plots was reduced rapidly after heading stage. Daily uptake of nitrogen and potassium per hill at maturing stage were 0.45mg and 0.68mg in control plots, but 4.80mg and 7.0mg respectively in ball complex plots. 2. Dry matter productivity of the rice plant in control plots, well coinciding with nutrients uptake pattern, was maximum just after heading stage decreased at maturing stage. But dry matter productivity in ball complex plots was much higher at maturing stage than at heading stage. 3. Ball complex application increased effective tillering rate, causing higher panicle number per hill. 4. Ball complex application brought about 528kg/10a of hulled grain yield while the conventional practice 423kg/10a. 5. Deep application of ball complex was superior to usual practice in terms of yield components such as panicle number per hill, filled grain number per panicle, maturing rate, and 1,000 grain weight. 6. From the morphological characteristics point of view, the deep application of ball complex made the flag leaf and the 2nd leaf heavier, larger and broader as compared to control treatment. 7. It is considered that by applying the ball complex fertilizer at depth of 12~13cm sufficient amount of nitrogen and potassium could be utilized by rice plants during the maturing stage and assimilated in the leaf blade, consequently making the flag leaf and the 2nd leaf bigger and healthier. The fact can easily explain that the ball complex plots had higher capacity of photosynthesis, less discoloration of lower leaves, bigger leaf area index, and better grain yield as compared to the conventional practice. In conclusion the deep application method of the ball complex fertilizer was superior to the routine topdressing method of the usual fertilizers.

  • PDF

Usefulness Evaluation of Open Mouth View when PET/CT scan In Tongue Cancer Patients (Tongue Cancer 환자에서 PET/CT 검사 시 Open Mouth 촬영법의 유용성 평가)

  • Kim, Jae Hwan;Yun, Jong Jun;Jung, Ji Wook;Kim, Jung Wook;Hwang, Ju Won;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.14-20
    • /
    • 2016
  • Purpose Tongue cancer is 1.8% of all cancer tumors occur in the tongue, it is known that the high incidence enough to account for 75% of oral cancer conducted a PET / CT examination for early diagnosis, metastasis, staging, etc. and. Tongue when PET / CT scan of a cancer patient and a Torso taken to close mouth lesions if the condition was caused due to the overlapping or corresponding artifacts are not clearly observed. The purpose of this study is to evaluate the changes that occur during PET / CT scan with open mouth and its usefulness under. Materials and Methods From June 2015 to March 2016 complained of herein by May 21 had received a diagnosis of tongue cancer underwent PET / CT scan patients were treated with a target (16 males, 5 female). The first was taken to close mouth Torso state, it was taken to add 1 bed open mouth condition. Tumor (T), measuring the Normal Tongue (NT), Lymph Node (LN) standard intake coefficient by setting a region of interest in the (standardized uptake value, SUV) SUVmean, the average value was measured SUVmax, drawn to each region of interest 3 times and Background (Carotid artery) was out of the SUV. In Chapter 3 of the slice to the tumor clearly visible by setting the region of interest to measure the change Tumor size was calculated average value. Gross Image resolution assessment were analyzed statistically through were divided into 1-5 points by the Radiation 7 people in 2, more than five years worked in specialized nuclear medicine compare to proceed with the blind test nonparametric test (wilcoxon signed rank test). (SPSS ver.18) Results $SUV_{mean}$ T's were in close mouth $5.01{\pm}2.70$ with open mouth $5.48{\pm}2.88$ (P<0.05), $SUV_{max}$ were respectively $8.78{\pm}5.55$ and $9.70{\pm}5.99$ (P<0.05). $SUV_{mean}$ in the NT were respectively $0.43{\pm}0.30$ and $0.34{\pm}0.24$ (P=0.20), $SUV_{max}$ was $0.56{\pm}0.34$ and $0.45{\pm}0.25$ (P=0.204). LN $SUV_{mean}$ were respectively $1.62{\pm}1.43$ and $1.69{\pm}1.49$ (P=0.161), $SUV_{mean}$ was $2.09{\pm}1.88$ and $1.99{\pm}1.74$ (P=0.131). Tumor size change is close mouth $4.96{\pm}4.66cm^2$ $5.33{\pm}4.64cm^2$ with 7.45% increase was (P<0.05), gross image resolution evaluation is $2.87{\pm}0.73$, $3.77{\pm}0.68$ with open mouth examinations 30.5% increase was (P<0.05). Conclusion Tumor SUV on the changes that had an increase in open mouth during inspection, the normal tongue and lymph node, but there was no significant difference in the change slightly. It is also one open mouth PET / CT scan will provide improved image to all patients with tongue cancer, but it could be confirmed that similar overall through the blind test, or tumor size changes and showing a high resolution image. It can be the perfect alternative method for problems that occur when the close mouth Open mouth PET / CT scan, but is believed to be through the open mouth to observe the boundary of overlapping or tumor of the oral cavity other structures a little more clearly. Tongue cancer patients how to recommend that the shooting further open mouth PET / CT.

  • PDF

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

Prediction of Parthenogenetic Developmental Potential by Polar Body Extrusion and First Cleavage on In Vitro Maturation and Development of Porcine Follicular Oocytes (돼지 난모 세포의 Ethanol 처리에 의한 단위 발생에 있어서 극체 방출란과 분할란 선별에 따른 배발달율 비교)

  • Kim, H.J.;Cho, S.R.;Choe, J.Y.;Choi, S.H.;Han, M.H.;Son, D.S.;Lee, S.S.;Sang, B.D.;Ryu, I.S.;Kim, I.C.;Kim, S.J.;Kim, I.H.;Kim, S.K.
    • Journal of Embryo Transfer
    • /
    • v.22 no.2
    • /
    • pp.121-126
    • /
    • 2007
  • The objective of this study was carried out to examine the selection effects of in vitro matured porcine follicular oocytes with polar body extrusion and early cleavage as non-invasive marker to know the developmental competence in advance. The porcine oocytes matured for 48 h were examined the polar body extrusion. The examined oocytes were matured for additional $16{\sim}18h$ and activated with 7% ethanol and cultured in $5{\mu}g/ml$ cytochalasin B for 5 h for diploid formation. The treated oocytes were cultured and examined the cleavage after 48 h and continued culturing for 5 days. The oocytes of 21.9% were discarded in morphological selection and 32.1% oocytes were discarded by failure of first polar body extrusion. The selected oocytes were matured and activated and then after 48 h the cleavage rates were examined. In morphologically selected oocytes, 15.8% oocytes were not cleaved and 52.6% oocytes were normally cleaved and 31.6% oocytes were hyper-cleaved over 8-cell stage. However in the first polar body extruded oocytes, 7.1% oocytes were not cleaved and 73.1% oocytes were normally cleaved and 19.8% oocytes were hyper-cleaved. The morphologically selected embryos that not cleavage-selected were developed in 16.7% up to blastocyst and the morphologically selected and cleavage-selected embryos were developed in 31.7%. The polar body extruded oocytes that were not carried out cleavage selection were developed in 39.0% and the polar body extruded and cleavage-selected embryos were developed 49.0%. The first cleavage timing was examined with 12 h interval after activation. In $0{\sim}12,\;12{\sim}24,\;24{\sim}36,\;and\;36{\sim}48h$ intervals, 4.1%, 68.6%, 19.1%, and 2.3% oocytes were cleaved and 5.9% oocytes were not cleaved until 48 after activation. The cleaved oocytes in each interval were cultured and developed upto blastocyst with 0, 39.1, 9.5, and 0%, respectively. This results suggests that polar body extruded and cleaved at $12{\sim}36h$ embryo has higher developmental potential than the others.

Tc-99m ECD Brain SPECT in MELAS Syndrome and Mitochondrial Myopathy: Comparison with MR findings (MELAS 증후군과 미토콘드리아 근육병에서의 Tc-99m ECD 뇌단일 광전자방출 전산화단층촬영 소견: 자기공명영상과의 비교)

  • Park, Sang-Joon;Ryu, Young-Hoon;Jeon, Tae-Joo;Kim, Jai-Keun;Nam, Ji-Eun;Yoon, Pyeong-Ho;Yoon, Choon-Sik;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.490-496
    • /
    • 1998
  • Purpose: We evaluated brain perfusion SPECT findings of MELAS syndrome and mitochondrial myopathy in correlation with MR imaging in search of specific imaging features. Materials and Methods: Subjects were five patients (four females and one male; age range, 1 to 25 year) who presented with repeated stroke-like episodes, seizures or developmental delay or asymptomatic but had elevated lactic acid in CSF and serum. Conventional non-contrast MR imaging and Tc-99m-ethyl cysteinate dimer (ECD) brain perfusion SPECT were Performed and imaging features were analyzed. Results: MRI demonstrated increased T2 signal intensities in the affected areas of gray and white matters mainly in the parietal (4/5) and occipital lobes (4/5) and in the basal ganglia (1/5), which were not restricted to a specific vascular territory. SPECT demonstrated decreased perfusion in the corresponding regions of MRI lesions. In addition, there were perfusion defects in parietal (1 patient), temporal (2), and frontal (1) lobes and basal ganglia (1) and thalami (2). In a patient with mitochondrial myopathy who had normal MRI, decreased perfusion was noted in left parietal area and bilateral thalami. Conclusion: Tc-99m ECD SPECT imaging in patients with MELAS syndrome and mitochondrial myopathy showed hypoperfusion of parieto-occipital cortex, basal ganglia, thalamus and temporal cortex, which were not restricted to a specific vascular territory. There were no specific imaging features on SPECT. The significance of abnormal perfusion on SPECT without corresponding MR abnormalities needs to be evaluated further in larger number of patients.

  • PDF

Changes of Distribution of Vascular Hydrophytes in the Nakdong River Estuary and Growth Dynamics of Schenoplectus triqueter, Waterfowl Food Plant (낙동강 하구의 수생관속식물의 분포 변화와 수금류(고니류)의 먹이식물인 세모고랭이의 성장 변화)

  • Kim, Gu-Yeon;Lee, Chan-Woo;Yoon, Hae-Soon;Joo, Gea-Jae
    • The Korean Journal of Ecology
    • /
    • v.28 no.5
    • /
    • pp.335-345
    • /
    • 2005
  • A study on changes on the distribution of vascular hydrophytes and the growth pattern of Schenoplectus triqueter (Scirpus triqueter) was undertaken at the Nakdong River estuary from 2002 to 2004. The change was due to physical alteration of the estuary for the past 25 years. These plant species are the major food sources for winter waterfowl. A total of 32 species of vascular hydrophytes from 17 families were found in the West Nakdong River (freshwater), the main channel of Nakdong River (freshwater) and the Nakdong River Estuary (brackish water). After the construction of the barrage on the estuary in 1987, the number of hydrophytes has remarkably increased to 17 species (5 species in 1985) in the main channel of the River. In particular, a community of Eurale ferox was found at the backwater wetland of the Daejeo side of the main channel. The introduced species of Eichhornia crassipes and Pistia stratiotes that were epidemic in 2001 at West Nakdong River was not found any more. The other species such as Nymphoides indica, Myriophyllum spicatum, Ruppia spp. were rediscovered. The large area (about 1,300ha) of Zostera spp. was the main sources of food for swans, but disappeared because of direct and indirect impacts of reclamation in the River estuary. Currently, there remains a small patch of Zostera spp. and about 250ha of S. triqueter. Schenoplectus triqueter grew mostly between April-September and tuber formed, between September-October. The growth of S. triqueter up to $60\sim80cm$ in length was observed in 5 sites out of the 7 sites in brackish area. Tubers of S. triqueter were eaten by waterfowls such as swans as winter food. In five sites, tubers took $44\sim57%$ of total biomass in October. Tubers were found in deep layers; $5\sim15cm$ (9%), $15\sim25cm$ (28%), $25\sim40cm$ (55%), below 40cm $(6\sim7%)$. The distribution of vascular hydrophytes has remarkably changed in the Nakdong River Estuary due to the reclamation of the area. In order to determine the extent of changes of the distribution of these plants and the carrying capacity of the area for waterfowl, an intensive research is urgently needed.

Optimization and Development of Prediction Model on the Removal Condition of Livestock Wastewater using a Response Surface Method in the Photo-Fenton Oxidation Process (Photo-Fenton 산화공정에서 반응표면분석법을 이용한 축산폐수의 COD 처리조건 최적화 및 예측식 수립)

  • Cho, Il-Hyoung;Chang, Soon-Woong;Lee, Si-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.642-652
    • /
    • 2008
  • The aim of our research was to apply experimental design methodology in the optimization condition of Photo-Fenton oxidation of the residual livestock wastewater after the coagulation process. The reactions of Photo-Fenton oxidation were mathematically described as a function of parameters amount of Fe(II)($x_1$), $H_2O_2(x_2)$ and pH($x_3$) being modeled by the use of the Box-Behnken method, which was used for fitting 2nd order response surface models and was alternative to central composite designs. The application of RSM using the Box-Behnken method yielded the following regression equation, which is an empirical relationship between the removal(%) of livestock wastewater and test variables in coded unit: Y = 79.3 + 15.61x$_1$ - 7.31x$_2$ - 4.26x$_3$ - 18x$_1{^2}$ - 10x$_2{^2}$ - 11.9x$_3{^2}$ + 2.49x$_1$x$_2$ - 4.4x$_2$x$_3$ - 1.65x$_1$x$_3$. The model predicted also agreed with the experimentally observed result(R$^2$ = 0.96) The results show that the response of treatment removal(%) in Photo-Fenton oxidation of livestock wastewater were significantly affected by the synergistic effect of linear terms(Fe(II)($x_1$), $H_2O_2(x_2)$, pH(x$_3$)), whereas Fe(II) $\times$ Fe(II)(x$_1{^2}$), $H_2O_2$ $\times$ $H_2O_2$(x$_2{^2}$) and pH $\times$ pH(x$_3{^2}$) on the quadratic terms were significantly affected by the antagonistic effect. $H_2O_2$ $\times$ pH(x$_2$x$_3$) had also a antagonistic effect in the cross-product term. The estimated ridge of the expected maximum response and optimal conditions for Y using canonical analysis were 84 $\pm$ 0.95% and (Fe(II)(X$_1$) = 0.0146 mM, $H_2O_2$(X$_2$) = 0.0867 mM and pH(X$_3$) = 4.704, respectively. The optimal ratio of Fe/H$_2O_2$ was also 0.17 at the pH 4.7.

Evaluating efficiency of Split VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes (골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan의 유용성 평가)

  • Mun, Jun Ki;Son, Sang Jun;Kim, Dae Ho;Seo, Seok Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.145-156
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the efficiency of Split VMAT planning(Contouring rectum divided into an upper and a lower for reduce rectum dose) compare to Conventional VMAT planning(Contouring whole rectum) for prostate cancer radiotherapy involving pelvic lymph nodes. Materials and Methods : A total of 9 cases were enrolled. Each case received radiotherapy with Split VMAT planning to the prostate involving pelvic lymph nodes. Treatment was delivered using TrueBeam STX(Varian Medical Systems, USA) and planned on Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). Lower rectum contour was defined as starting 1cm superior and ending 1cm inferior to the prostate PTV, upper rectum is a part, except lower rectum from the whole rectum. Split VMAT plan parameters consisted of 10MV coplanar $360^{\circ}$ arcs. Each arc had $30^{\circ}$ and $30^{\circ}$ collimator angle, respectively. An SIB(Simultaneous Integrated Boost) treatment prescription was employed delivering 50.4Gy to pelvic lymph nodes and 63~70Gy to the prostate in 28 fractions. $D_{mean}$ of whole rectum on Split VMAT plan was applied for DVC(Dose Volume Constraint) of the whole rectum for Conventional VMAT plan. In addition, all parameters were set to be the same of existing treatment plans. To minimize the dose difference that shows up randomly on optimizing, all plans were optimized and calculated twice respectively using a 0.2cm grid. All plans were normalized to the prostate $PTV_{100%}$ = 90% or 95%. A comparison of $D_{mean}$ of whole rectum, upperr ectum, lower rectum, and bladder, $V_{50%}$ of upper rectum, total MU and H.I.(Homogeneity Index) and C.I.(Conformity Index) of the PTV was used for technique evaluation. All Split VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : Using DVH analysis, a difference between the Conventional and the Split VMAT plans was demonstrated. The Split VMAT plan demonstrated better in the $D_{mean}$ of whole rectum, Up to 134.4 cGy, at least 43.5 cGy, the average difference was 75.6 cGy and in the $D_{mean}$ of upper rectum, Up to 1113.5 cGy, at least 87.2 cGy, the average difference was 550.5 cGy and in the $D_{mean}$ of lower rectum, Up to 100.5 cGy, at least -34.6 cGy, the average difference was 34.3 cGy and in the $D_{mean}$ of bladder, Up to 271 cGy, at least -55.5 cGy, the average difference was 117.8 cGy and in $V_{50%}$ of upper rectum, Up to 63.4%, at least 3.2%, the average difference was 23.2%. There was no significant difference on H.I., and C.I. of the PTV among two plans. The Split VMAT plan is average 77 MU more than another. All IMRT verification gamma test results for the Split VMAT plan passed over 90.0% at 2 mm / 2%. Conclusion : As a result, the Split VMAT plan appeared to be more favorable in most cases than the Conventional VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes. By using the split VMAT planning technique it was possible to reduce the upper rectum dose, thus reducing whole rectal dose when compared to conventional VMAT planning. Also using the split VMAT planning technique increase the treatment efficiency.

  • PDF