Combined Convective Heat Transfer from Vertical Parallel Plates (수직 평행평판에서의 혼합대류 열전달)

  • 양성환;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.2
    • /
    • pp.299-306
    • /
    • 1989
  • The combined convective heat transfer from vertical parallel plates with constant temperature has been studied by numerical method. The governing equations for the system are solved by the finite difference method and successive over relaxation scheme for Re$_{L}$ = 50 - 500, Gr = 10$^{4}$, Pr = 0.7. Results for various plate spacings and plate lengths are as follows ; For various plate spacings, the mean Nusselt number increases and then decreases as the dimensionless plate spacing increases. The optimum plate spacing for maximum mean Nusselt number decreases with increasing Reynolds number and can be expressed as a function of Reynolds number. For various plate lengths, the mean plate Nudest number increases as the dimensionless plate length decreases and Reynolds number increases.

Mixed convection from two isothermal, vertical, parallel plates (등온 수직 평판에서의 혼합대류 열전달)

  • 박문길;이재신;양성환;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1645-1651
    • /
    • 1990
  • The steady laminar mixed convection from two finite vertical parallel plates has been studied by numerical procedure. The governing equations are solved by the finite difference method and point successive over relaxation scheme at R3=100-1000, Gr=0-10$^{6}$ , Pr=0.71 and dimensionless plate spacing b/$\ell$=0.05-0.1. The plume interaction caused by the thermal interference of two plates is observed. As Reynolds numbers are increased, optimum plate spacings are moved to narrow spacings at the same Grashof number, and as Grashof numbers are increased, to wide spacings at the same Reynolds number.

Mixed convection heat transfer from vertically parallel and misaligned plates (수직 평판의 평행배열과 엇갈린 배열에서 혼합대류 열전달)

  • 김상영;정한식;권순석
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.68-74
    • /
    • 1993
  • The mixed convection heat transfer has been studied numerically for misaligned and parrallel arrays of two flat plates at 100.leg.Re.leg.700, 0.1.leg.B.leg.1.0, 0.2.leg.leg.PHI.$_{R}$.leg.1Gr=10$^{4}$ and Pr=0.71. For misaligned plates and parallel plates, the optimum plate spacings move to the narrow spacing as Reynolds number and .PHI.$_{R}$ increase and can be expressed by the correlation equations at Gr=10$^{4}$. The optimum plate spacings for parallel plates sharply move to the narrow spacing compared with misaligned plates. The maximum mean Nusselt number of parallel plates shows higher value than that of misaligned plates and can be expressed by the correlation equations at Gr=10$^{4}$.EX>.

  • PDF

A Study on the Optimum Design of Stiffened Plates under Combined Loads (조합하중이 작용하는 보강평판의 최적설계 연구)

  • 원종진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1059-1068
    • /
    • 1990
  • The minimum weight design for the simply-supported eccentrically stiffened plates subjected to combined loads is studied according to the stiffening configuration. The optimal programming is accomplished by formulating the design requirements in terms of a mathematical programming problem, and by using the gradient projection algorithm. The Huber type equilibrium equation is used as the governing equation for the overall buckling. The overall buckling of stiffened plates and the local buckling of the unstiffened plate between stiffeners and the stiffeners themselves are used as behavior constraints. Results of design examples for the orthogonally stiffening case compared with those of the other study support that the present study is feasible. Design examples for the symmetrically oblique stiffening case are presented and the results indicate that a significant improvement in design efficiency may be achieved through symmetrically oblique stiffening compared to the orthogonal stiffening under the combined loading condition.

Optimal shape Design of Curved Electrodes for a Rotary Microactuator (회전구동형 마이크로액츄에이터 전극의 최적형상)

  • Jung, Sung-Hwan;Jeon, Jong-Up;Pak, Y. Eu-Gene;Lee, Suk-Han
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1145-1147
    • /
    • 1999
  • 평판전극배열을 이용한 회전구동형 마이크로 액츄에이터의 구동력을 증대시키기 위하여 전극의 형상을 최적화 하였다. 기존 평판구동형 마이크로 액츄에이터의 형상을 변형시켜 반경에 무관하게 전극의 수직간격을 최소간격으로 일정하게 유지함으로서 구동력을 배가시키는 효과를 발생시켰다. 이러한 구동력의 증가는 결국 요구되는 변위를 만족시키면서 고유진동수를 증가시켜 마이크로액츄에이터의 구동성능을 향상시킬 수 있다.

  • PDF

Mixed Convection Heat Transfer from Vertically Misaligned Isothermal plates (수직으로 엇갈린 등온평판에서의 혼합대류 열전도)

  • 권순석;김상영;박순업
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.52-61
    • /
    • 1992
  • The steady laminar mixed convection from vertically misaligned, isothermal plastes has been studied by numerical procedure. The governing equations are solved by the finite difference method using successive using successive over relaxation scheme at Re=100-800, $Gr=10^3-10^6$, Pr=0.71 and dimensionless plate spacings b/L=0.1-1.0. The plume interaction caused by the thermal interference of twoplates is observed. As Reynolds numbers increase, the optimum plate spacings are moved to narrow spacings at the same Grashof number and as Grashof numbers increase, to wide spacings at the same Reynolds number.

  • PDF

Study on copper end-tab shape for maximum heat discharging performance (방열 성능 향상을 위한 구리 엔드 탭의 최적형상 연구)

  • Choi, Yeou-Myeong;Choi, Yoon-Hwan;Cho, Sang-Myung;Park, Jung-Hyun;Lee, Yeon-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • When implementing butt joint welding of two plates, it is useful to attach end-tabs made of a metal with high heat conductivity (e.g., copper) at the front and back sides of the welded plates to prevent the bead from rolling down and prevent defects that may occur at the tips of the weld zone. In this study, the fin shape, which is known to have good heat discharging characteristics by natural convection, has been applied to enhance the cooling performance of the end-tab. From both experiment and numerical analysis, it was confirmed that end-tabs with fin-shaped holes have better heat discharging performance than end-tabs without holes. Through thermal and fluid flow analysis, the cooling rates of end-tabs with different hole shapes were estimated in order to figure out characteristics of shape factor that are important for the heat discharging performance. As a result, we found that the structure including vertical fins with optimal fin gap was the best-performing shape.

Reduction Characteristics of Electromagnetic Penetration through a Slit in a Conducting Screen by a Loaded Triangle Plate (삼각형 도체판 장하에 의한 무한 도체 평판 슬릿의 침투 전자파 저감 특성)

  • Cho, Byung-Ho;Lee, Seung-Ik;Kim, Hyo-Kyun;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.7
    • /
    • pp.767-773
    • /
    • 2014
  • This paper presents the reduction characteristics of electromagnetic penetration through a slit in conducting screen by loaded plate. The FDTD method is used in theoretical analysis. And the characteristics of penetrated electric fields are calculated in terms of length, width, shape, position, and height of the loaded plate to find out how the geometry of plate influences the reduction characteristics of the electromagnetic penetration and shielding effectiveness. The results show that the characteristics of penetrated electric field and shielding effectiveness depend on the geometry of loaded plate. In particular, the optimal geometry of loaded plate which minimize penetrated electric field are verified.

Reduction Characteristics of Electromagnetic Penetration through a Slot in a Conducting Screen by a Loaded Plate (도체판을 부가한 무한 도체 평판 슬롯의 침투 전자파 저감 특성)

  • Cho, Byung-Ho;Jung, Sung-Woo;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1094-1099
    • /
    • 2012
  • This paper presents the reduction characteristics of electromagnetic penetration through a slot in conducting screen by loaded plate. The FDTD method is used in theoretical analysis. And the characteristics of penetrated electric fields are calculated in terms of length, width, position, and height of the loaded plate to find out how the geometry of plate influences the reduction characteristics of the electromagnetic penetration. The results show that the characteristics of penetrated electric field depend on the geometry of loaded plate. In particular, the optimal geometry of loaded plate which minimize penetrated electric field are verified.

Pool Boiling Enhancement of R-123 Using Perforated Plates (다공판을 사용한 R-123 풀비등 열전달 촉진)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.5
    • /
    • pp.275-281
    • /
    • 2016
  • In this study, we investigate the pool boiling enhancement caused by perforated plates on top of a smooth surface. We conduct tests using R-123 at atmospheric pressure. It was shown that perforated plates significantly enhanced the pool boiling of the smooth surface. The reason may be attributed to the increased bubble contact area between the plates. The results showed that the enhancement ratio was dependent on the heat flux. At high heat flux, the enhancement ratio increased as the porosity increased. However, at low heat flux, the enhancement ratio decreased as the porosity increased. For the present investigation, the optimum configuration had a pore diameter of 2.0 mm, pore pitch of $2.5mm{\times}5.0mm$ or $5.0mm{\times}5.0mm$, and a gap width of 0.5 mm, which yielded heat-transfer coefficients that are close to those of GEWA-T. The optimum porosity for R-123 was significantly larger than that of water or ethanol. The reason for this may be the large liquid-to-vapor density ratio along with the small latent heat of vaporization of R-123. The perforated plates yielded smaller boiling hysteresis compared with that of the smooth surface.