• Title/Summary/Keyword: 최저강하고도

Search Result 170, Processing Time 0.033 seconds

The Development of a Cryotherapy System (한냉물리치료기의 개발)

  • Kim, Yeong-Ho;Yang, Gil-Tae;Jang, Yun-Hui;Park, Si-Bok;Ryu, Jin-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.6
    • /
    • pp.617-622
    • /
    • 1998
  • A cryotherapy system using cold air was developed. The developed system had superior low-temperature characteristics with various flow rates and nozzle sizes, and used R-404A, as a coolant, which has no destructive effects of Ozone layers. Flow rates and the treatment time can be easily altered during the operation. In addition, and alarm system was designed for the overload, overheat, and over-charge of the machine. For clinical applications, skin temperatures, intra-articular temperatures of the knee joint and intra-muscluar temperatures of the gluteal muscles were measured during and after the cryotherapy. After a 5-minute therapy, skin and intra-articular temperatures decreased by $23.3{\pm}4.7 and 4.1 {\pm}1.0^{circ}C$, respectively. A 5-minute cryotherapy was good enough to maintain low intra-articular temperatures for 2-3 hours. Resting intra-muscular temperatures in 2, 4, and 6cm deep in the gluteal muscle were $36.5{\pm}1.2, 36.9{\pm}0.2, 37.1{\pm}0.2^{circ}C$, respectively (p<0.05). Lowest temperatures in 2, 4, and 6cm depth were $35.1{\pm}0.7, 36.2{\pm}0.4, 36.9{\pm}0.3^{circ}C$, respectively (p<0.05). Temperatures after a 2-hour cold air application on the skin and in the muscle in dept도 of 2, 4, and 6cm were $32.2{\pm}1.1, 36.2{\pm}0.5, 36.6{\pm}0.3, 36.9{\pm}0.3^{circ}C$respectively (p<0.05). Temperatures on the skin and in the muscle significantly decreased after 2 hours, compared with before cold air application (p<0.05). The intra-muscular temperature was changed more slowly than the skin temperature, and the deeper the muscle, the lesser temperature changes. The effect of a 5-minute cold air application lasts up to 2 hours, and it seems that the rebound-rise of the temperature dut to the reactive vasodilatation does not occur in the gluteal muscle.

  • PDF

The Effect of Radiation Therapy on hemophilic Athropathy (혈우병성 관절증에 대한 방사선 치료의 역할)

  • Kang Jin Oh;Hong Seong Eon;Kim Sang Gi;Shin Dong Oh
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.106-110
    • /
    • 2005
  • Purpose : Repetitive bleeding into the joint space is the cause of debilitative hemophilic arthropathy. To interrupt this process, we treated the hemophilic patients suffering from repetitive joint bleeding with radiation therapy. Materials and Methods : From 1997 to 2001, a total of 41 joints from 37 hemophilic arthropathy patients were treated with radiation therapy at Kyung Hee University Hospital. The treated joints were 35 ankles, 3 knees and 3 elbows, respectively. The age of the patients ranged from 4 to 27 years (median age: 11 years). The radiation dose ranged from 900 cGy to 2360 cGy (median dose: 900cGy). The fraction size was 150 cGy, 180 cGy or 200 cGy. The number of bleeding in one year before and after radiotherapy was compared. Results : There was a tendency of frequent bleeding for the Patients younger than 11 (p=0.051) but there was also a tendency for more improvement in this group (p=0.057). The number of joint bleedings was related with joint pain (p=0.012) and joint swelling (p=0.033) but not with the Arbold-Hilgartner stage (p=0.739), cartilage destruction (p=0.718) and synovial hypertrophy (p=0.079). The number of bleeding was reduced in thirty-three cases, and eight cases showed no improvement after radiation therapy. The average number of bleeding in a month was 2.52 before radiotherapy, but this was reduced to 1.4 after radiotherapy (p=0.017). Conclusion : Radiation therapy was effective for the hemophilia patients with repetitive joint bleeding to decrease the bleeding frequency and to prevent hemophilic arthropathy.

Evaluation of Dosimetry and Image of Very Low Dose CT Attenuation Correction for Pediatric PET/CT: Phantom Study (팬텀을 이용한 소아 PET/CT 검사 시 감쇄보정 CT 선량과 영상 평가)

  • Bahn, Young-Kag;Kim, Jung-Yul;Park, Hoon-Hee;Kang, Chun-Goo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.53-59
    • /
    • 2011
  • Purpose: To evaluate the dosimetry and image of very low does CT attenuation correction for phantom using pediatric PET/CT. Materials and methods: three PET / CT scanners (Discovery STe, BiographTruepoint 40, Discovery 600) as a child-size acrylic phantom and ion chamber dosimeter (Unfous Xi CT, Sweden) using a CT image acquisition parameters (10, 20, 40, 80, 100, 160 mA; 80, 100, 120, 140 kVp) by varying the depth dose and evaluate $CTDI_{vol}$ value. And each attenuation corrected PET/CT images used NEMA PET Phantom$^{TM}$ (NU2-1994) was evaluated by SUV. Results: Abdominal diagnosis CT dose in general pediatric (about 10 ages) parameter (100 kVp, 100 mA) than very low dose CT parameter (80 kVp, 10 mA) at the depth dose was reduced approximately 92%, $CTDI_{vol}$ was reduced to about 88%. Each CT attenuation corrected parameters PET images showed no change in the value of SUV. Conclusion: for pediatric patients, PET/CT scan can be obtained with very low dose attenuation correction CT (80 kVp, 10 mA), and such attenuation correction CT dose was reduced 100 fold than diagnosis CT dose. PET / CT scan used very low dose CT attenuation correction in pediatric patients can be helpful in reducing radiation dose.

  • PDF

Relationship between maximum bite force and facial skeletal pattern (최대 교합력과 안면 골격 형태에 관한 연구)

  • Choi, Won-Cheul;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.33 no.6 s.101
    • /
    • pp.437-451
    • /
    • 2003
  • The purpose of this study was to measure maximum bite force and to investigate its relationship with anteroposterior, vertical, and transverse facial skeletal measurements. From among the dental students at the College of Dentistry, forty subjects (26 male and 14 female) were selected. With two sets of strain gauge, maximum bite force at the right and left first molars and anterior teeth was measured in the morning and afternoon. After taking lateral and posteroanterior cephalograms, fifty and nineteen variables were evaluated, respectively Paired t-tests and an independent t-test were done and correlation coefficients were obtained. 1. The maximum bite force at the first molars was $68.0\pm13.9kg$. in males and $55.6\pm10.5kg$ in females (p<0.05) while the force at the anterior teeth was $8.4\pm4.9kg\;and\;1.1\pm3.4kg$ respectively (p<0.05). 2. Some tendency for a greater value of maximum bite force at the preferred side was observed but not statistically significant (p>0.05). 3. Significant difference was observed between the strong bite force group and the weak bite force group in some cephalometric and other measurements (p<0.05). N-S-Ar, S-Ar-Go, FH-Hl, IMPA and MMO showed a significant difference in posterior maximum bite force (P). N-S-Ar and FH-H1 also showed a significant difference in anterior maximum bite force (A). 4. Several cephalometric variables showed some correlation with maximum bite force (p<0.05). N-S-Ar, S-Ar-Go, UGA, FH-H6, FH-H1, body weight and MMO were significantly correlated with posterior maximum bite force (P). Go-Me, P-1 and IMPA were significantly correlated with anterior maximum bite force (A).

A Management Plan According to the Estimation of Nutria (Myocastorcoypus) Distribution Density and Potential Suitable Habitat (뉴트리아(Myocastor coypus) 분포밀도 및 잠재적 서식가능지역 예측에 따른 관리방향)

  • Kim, Areum;Kim, Young-Chae;Lee, Do-Hun
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.2
    • /
    • pp.203-214
    • /
    • 2018
  • The purpose of this study is to estimate the concentrated distribution area of nutria (Myocastor coypus) and potential suitable habitat and to provide useful data for the effective management direction setting. Based on the nationwide distribution data of nutria, the cross-validation value was applied to analyze the distribution density. As a result, the concentrated distribution areas thatrequired preferential elimination is found in 14 administrative areas including Busan Metropolitan City, Daegu Metropolitan City, 11 cities and counties in Gyeongsangnam-do and 1 county in Gyeongsangbuk-do. In the potential suitable habitat estimation using a MaxEnt (Maximum Entropy) model, the possibility of emergency was found in the Nakdong River middle and lower stream area and the Seomjin riverlower stream area and Gahwacheon River area. As for the contribution by variables of a model, it showed DEM, precipitation of driest month, min temperature of coldest month and distance from river had contribution from the highest order. In terms of the relation with the probability of appearance, the probability of emergence was higher than the threshold value in areas with less than 34m of altitude, with $-5.7^{\circ}C{\sim}-0.6^{\circ}C$ of min temperature of the coldest month, with 15-30mm of precipitation of the driest month and with less than 1,373m away from the river. Variables that Altitude, existence of water and wintertemperature affected settlement and expansion of nutria, considering the research results and the physiological and ecological characteristics of nutria. Therefore, it is necessary to reflect them as important variables in the future habitable area detection and expansion estimation modeling. It must be essential to distinguish the concentrated distribution area and the management area of invasive alien species such as nutria and to establish and apply a suitable management strategy to the management site for the permanent control. The results in this study can be used as useful data for a strategic management such as rapid management on the preferential management area and preemptive and preventive management on the possible spreading area.

A Study on Radiation Safety Management by Dental Hygienist (치과위생사의 방사선 안전관리에 대한 조사 연구)

  • Kang, Eun-Ju;Lee, Kyung-Hee;Kim, Young-Im
    • Journal of dental hygiene science
    • /
    • v.5 no.3
    • /
    • pp.105-112
    • /
    • 2005
  • In spite of relatively low level of radiation dose used at dental clinics, long term exposure may be harmful, so radiation workers at dental clinics must be well aware of its danger. This study was to analyze the factors to have an influence on safety management behavior in the radiography chamber by understanding the relationship among the knowledge, attitudes and behavior in regard with radiation safety management by dental hygienists in order to take preventive measures for dental hygienists and suggest ideas to develop radiation safety training programs. For this, we contacted dental hygienists working at the local dental clinics for 4 months from December of 2003 to march of 2004 and obtained the following findings. 1. Concering the knowledge level of radiation safety management, $8.59{\pm}2.36$ was average score with the highest of 13 and the lowest of 3 from 15-scale test. In addition, knowledge level of radiation safety management by general characteristics showed statistically significant difference according to working experience (p < 0.001), marital status (p < 0.001), attendance rate of radiation safety management training program (p < 0.001), and type of clinic (p < 0.001). 2. Concering the attitude level of radiation safety management, $4.08{\pm}0.50$ is average score with the highest of $4.31{\pm}0.73$ and the lowest of $3.82{\pm}0.89$ by item from 5-scale test. Besides, attitude level of radiation safety management by general characteristics showed statistically significant difference according to age (p < 0.001), working experience (p < 0.05), attendance rate of radiation safety management training program (p < 0.01), and type of clinic (p < 0.001). 3. Concering the behavior level of radiation safety management, $2.89{\pm}0.77$ is average score from 5-scale test, which was relatively low in comparison with the level of attitude and the highest score was $3.82{\pm}0.94$ and the lowest $2.37{\pm}1.04$ by item. Behavior level of radiation safety management by general characteristics showed statistically significant difference according to working experience (p < 0.001) and type of clinic (p < 0.001). 4. From the survey of relationship among knowledge, attitude and behavior of radiation safety management was, we found that the higher the knowledge level of radiation safety management, the higher the level of attitude and behavior, and the higher the attitude level was, the higher the level of behavior.

  • PDF

Reset of Cultivation Zones of Green Manure Crops under Paddy Field in South Korea: Focused on Minimum Temperature and Drainage Class (국내 주요 녹비작물 논재배 적지 재설정: 1월 평균 최저기온 및 배수등급을 기준으로)

  • Kim, Min-Tae;Kim, Kwang Seop;Park, Ki Do;Ryu, Jin-Hee;Choi, Jong-Seo;Ku, Ja-Hwan;Kim, Suk-Jin;Lee, Choon-Woo;Lee, Kyungdo;Kang, Hang-Won
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.60 no.1
    • /
    • pp.91-96
    • /
    • 2015
  • Stable production of green manure crop is one of the critical factor for successful implementation of environmental-friendly agriculture in South Korea. Most green manure crops including hairy vetch cultivated in South Korea must be passed cold winter season. This study was conducted to establishment of cultivation zones on green manure crops under paddy field in South Korea using on minimum temperature and drainage class. In order to build the spatial distribution map, hairy vetch, triticale, barley, rye, and clover as green manure crop were selected and mean of daily minimum temperature and drainage class in paddy field were considered as limiting factor for stable growth of green manure crop. And cultivation zone on green manure crops was divided into two categories; 'Availability area' and 'Safety area'. Low limit temperature on green manure crops in this study was the following. Temperature on 'Availability area' was $-10^{\circ}C$, $-8^{\circ}C$, $-6^{\circ}C$, and $-20^{\circ}C$ for hairy vetch (including triticale), barley, clover, and rye respectively. And temperature on 'Safety area' was lower $-2^{\circ}C$ compared to that of 'Availability area' exception rye which was the same degree. Rye was expected to safely cultivated the almost whole paddy field (99.71%) of South Korea. 'Safety area' among the whole paddy field for hairy vetch, barley, and clover were 86.58, 53.06, and 15.76% respectively. The spatial distribution map of green manure crops reestablished in this study could be used the policy and agricultural management for environmental-friendly agriculture using green manure crops in South Korea.

The Evaluation of Meteorological Inputs retrieved from MODIS for Estimation of Gross Primary Productivity in the US Corn Belt Region (MODIS 위성 영상 기반의 일차생산성 알고리즘 입력 기상 자료의 신뢰도 평가: 미국 Corn Belt 지역을 중심으로)

  • Lee, Ji-Hye;Kang, Sin-Kyu;Jang, Keun-Chang;Ko, Jong-Han;Hong, Suk-Young
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.4
    • /
    • pp.481-494
    • /
    • 2011
  • Investigation of the $CO_2$ exchange between biosphere and atmosphere at regional, continental, and global scales can be directed to combining remote sensing with carbon cycle process to estimate vegetation productivity. NASA Earth Observing System (EOS) currently produces a regular global estimate of gross primary productivity (GPP) and annual net primary productivity (NPP) of the entire terrestrial earth surface at 1 km spatial resolution. While the MODIS GPP algorithm uses meteorological data provided by the NASA Data Assimilation Office (DAO), the sub-pixel heterogeneity or complex terrain are generally reflected due to coarse spatial resolutions of the DAO data (a resolution of $1{\circ}\;{\times}\;1.25{\circ}$). In this study, we estimated inputs retrieved from MODIS products of the AQUA and TERRA satellites with 5 km spatial resolution for the purpose of finer GPP and/or NPP determinations. The derivatives included temperature, VPD, and solar radiation. Seven AmeriFlux data located in the Corn Belt region were obtained to use for evaluation of the input data from MODIS. MODIS-derived air temperature values showed a good agreement with ground-based observations. The mean error (ME) and coefficient of correlation (R) ranged from $-0.9^{\circ}C$ to $+5.2^{\circ}C$ and from 0.83 to 0.98, respectively. VPD somewhat coarsely agreed with tower observations (ME = -183.8 Pa ~ +382.1 Pa; R = 0.51 ~ 0.92). While MODIS-derived shortwave radiation showed a good correlation with observations, it was slightly overestimated (ME = -0.4 MJ $day^{-1}$ ~ +7.9 MJ $day^{-1}$; R = 0.67 ~ 0.97). Our results indicate that the use of inputs derived MODIS atmosphere and land products can provide a useful tool for estimating crop GPP.

Relationship between XRCC1 Polymorphism and Acute Complication of Chemoradiation Therapy in the Patients with Colorectal Cancer (대장, 직장암 환자에서 화학방사선치료의 급성 부작용과 XRCC1 유전자 다형성과의 상관관계)

  • Kim Woo-Chul;Hong Yun-Chul;Choi Sun-Keun;Woo Ze-Hong;Nam Jeong-Hyun;Choi Gwang-Seong;Lee Moon-Hee;Kim Soon-Ki;Song Sun-U.;Loh John-Jk
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.30-36
    • /
    • 2006
  • Purpose: It is well known from clinical experience that acute complications of chemoradiation therapy vary from patients to patients. However, there are no known factors to predict these acute complications before treatment starts. The human XRCC1 gene is known as a DNA base excision repair gene. We investigated the possibilities of XRCC1 gene polymorphisms as a predictor for the acute complications of chemoradiation therapy in colorectal cancer patients. Materials and Methods: From July 1997 to June 2003, 86 colorectal cancer patients (71 rectal cancer, 13 sigmoid colon cancer and 2 colon cancer patients) were treated with chemoradiation therapy at the Department of Radiation Oncology, Inha University Hospital. Twenty-two patients were in stage B, 50 were in stage C, 8 were in stage D and 6 patients were unresectable cases. External radiation therapy was delivered with 10MV X-ray at a 1.8 Gy fraction per day for a total dose of radiation of $30.6{\sim}59.4 Gy$ (median: 54 Gy). All the patients received 5-FU based chemotherapy regimen. We analyzed the acute complications of upper and lower gastrointestinal tract based on the RTOG complication scale. The initial and lowest WBC and platelet count were recorded during both the RT period and the whole treatment period. Allelic variants of the XRCC1 gene at codons 194, 280 and 399 were analyzed in the lymphocyte DNA by performing PCR-RFLP. Statistical analyses were carried out with the SAS (version 6.12) statistical package. Results: When all the variables were assessed on the multivariate analysis, recurrent disease revealed the factors that significantly correlated with upper gastrointestinal acute complications. Arg399Gln polymorph isms of the XRCC1 gene, the radiation dose and the frequencies of chemotherapy during radiation therapy were significantly correlated with lower gastrointestinal complications. Arg399Gln polymorph isms also affected the decrease of the WBC and platelet count during radiation therapy. Conclusion: Although the present sample size was too small for fully evaluating this hypothesis, this study suggests that Arg399Gln polymorph isms of the XRCC1 genes may be used as one of the predictors for acute complications of chemoradiation therapy in colorectal cancer patients.

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF