• Title/Summary/Keyword: 최소발화온도

Search Result 84, Processing Time 0.021 seconds

The Measurement of the Fire and Explosion Properties for 2-Methyl-1-butanol (2-Methyl-1-butanol의 화재 및 폭발 특성치의 측정)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.8-14
    • /
    • 2015
  • For the safe handling of 2-methyl-1-butanol being used in various ways in the chemical industry, the flash point and the autoignition temperature(AIT) of 2-methyl-1-butanol was experimented. And, the lower explosion limit of 2-methyl-1-butanol was calculated by using the lower flash point obtained in the experiment. The flash points of 2-methyl-1-butanol by using the Setaflash and Pensky-Martens closed-cup testers measured $40^{\circ}C$ and $44^{\circ}C$, respectively. The flash points of 2-methyl-1-butanol by using the Tag and Cleveland open cup testers are measured $49^{\circ}C$ and $47^{\circ}C$. The AIT of 2-methyl-1-butanol by ASTM 659E tester was measured as $335^{\circ}C$. The lower explosion limit by the measured flash point $40^{\circ}C$ was calculated as 1.30 Vol.%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.

The Measurement and Investigation of Fire and Explosion Characteristics of Isopropyl Alcohol (이소프로필 알코올의 화재 및 폭발 특성치의 측정 및 고찰)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.8-15
    • /
    • 2012
  • For the safe handling of isopropyl alcohol, the explosion limits were investigated. The lower flash points, upper flash points, fire point, and AITs(autoignition temperatures) by ignition time delay for isopropyl alcohol were experimented. By using literature data, the lower and upper explosion limits of isopropyl alcohol were recommended as 2.0 and 12.0 vol%, respectively. The lower flash points of isopropyl alcohol were experimented $12{\sim}14^{\circ}C$ by using closed-cup tester and $18{\sim}19^{\circ}C$ by using open cup tester. And the upper flash points of isopropyl alcohol was experimented $38^{\circ}C$ by using Setaflash closed-cup tester. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus was $463^{\circ}C$.

Ignition Characteristics of n-Dodecane Fuel Droplet on a Hot Surface (n-Dodecane 연료의 고온면 점화특성)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.116-121
    • /
    • 2010
  • The present study has been performed to investigate the ignition characteristics of a n-dodecane fuel droplet on the hot surface. Simplified bench scale test setup was built to examine the effect of air flow on the ignition temperature of fuel droplet. IR pyrometric sensor was used to measure the surface temperature, the measured temperature using IR pyrometer was directly compared with k-type thermocouple. The ignition of n-dodecane fuel droplet was divided into two stage - cool flame and hot flame - with the air flow rate except the case of air flow rate 3.0 lpm. The ignition temperature and probability was greatly affected by the air flow rate and the MHSIT of the present study was about $300^{\circ}C$ for air flow rate of 0.5 lpm.

Characteristics of Dust Explosion in Dioctyl Terephthalic Acid Manufacturing Process (디옥틸테레프탈산 제조공정에서 분진폭발 특성에 관한 연구)

  • Lee, Chang Jin;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.790-803
    • /
    • 2019
  • The dioctyl terephthalic acid (DOTP) process produces plastic plasticizers by esterification of terephthalic acid with powder in the form of octanol. In this study, the dust explosion characteristics of terephthalic acid directly injected into the manhole in the form of powder in the presence of flammable solvent or vapor in the reactor of this process were investigated. Dust particle size and particle size distribution dust characteristics were investigated, and pyrolysis characteristics of dust were investigated to estimate fire and explosion characteristics and ignition temperature. Also, the minimum ignition energy experiment was performed to evaluate the explosion sensitivity. As a result, the average particle size of terephthalic acid powder was $143.433{\mu}m$. From the thermal analysis carried out under these particle size and particle size distribution conditions, the ignition temperature of the dust was about $253^{\circ}C$. The lower explosive limit (LEL) of the terephthalic acid was determined to be $50g/m^3$. The minimum ignition energy (MIE) for explosion sensitivity is (10 < MIE < 300) mJ, and the estimated minimum ignition energy (Es) based on the ignition probability is 210 mJ. The maximum explosion pressure ($P_{max}$) and the maximum explosion pressure rise rate $({\frac{dP}{dt}})_{max}$ of terephthalic acid dust were 7.1 bar and 511 bar/s, respectively. The dust explosion index (Kst) was 139 mbar/s, corresponding to the dust explosion grade St 1.

The Minimum Autoignition Temperature Behavior(MAITB) of n-Decane and Acetic acid Mixture (n-Decane과 Acetic acid 혼합물의 최소자연발화온도 거동)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.49-54
    • /
    • 2013
  • The autoignition temperature(AIT) is important index for the safe handling of flammable liquids which constitute the solvent mixtures. This study measured the AITs and ignition delay time for n-Decane and Acetic acid system by using ASTM E659 apparatus. The AITs of n-Decane and Acetic acid which constituted binary system were $212^{\circ}C$ and $512^{\circ}C$, respectively. The experimental AITs of n-Decane and Acetic acid system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D.(average absolute deviation). And n-Decane and Acetic acid system was shown the minimum autoignition temperature behavior(MAITB).

Prediction and Measurement of Autoignition Temperature of Toluene and 2-Butanol System (톨루엔과 2-부탄올 계의 최소자연발화온도의 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.73-78
    • /
    • 2015
  • The autoignition temperatures(AIT) of solvent mixture is important index for the safe handling of flammable liquids which constitute the solvent mixtures. Therefore, the AITs of common pure chemical substances are widely reported, but very limited data are available for mixtures. This study, the toluene and 2-butnaol system which used mixture solution solvent was measured the AIT and ignition delay time by using ASTM E659 apparatus. The AITs of toluene and 2-butanol constituted binary system were $547^{\circ}C$ and $400^{\circ}C$, respectively. The experimental AIT of toluene and 2-butanol were a good agreement with the calculated AIT by the proposed equations with a few average absolute deviation(A.A.D.).

Numerical Analysis on the Autoignition of Hydrogen/Air Mixture Near a Hot Surface (고온벽면에 의한 수소-공기 예혼합기체의 자연발화에 관한 수치적 해석)

  • 박은성;백승욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.70-76
    • /
    • 1992
  • Ignition of hydrogen-air premixed gas in the vicinity of a hot surface has been investigated. Especially multistep reaction model was compared with a single reaction model. It was found that the multistep model with 48 step elementary chemical reactions produced a phenomenologically reasonable trend in ignition delays. The ignition d(2lays increase as the mixture becomes either fuel-rich or fuel-lean with a minimum near the stoichiometric value. The minimum surface temperature has been deduced by extrapolating predicted ignition delays. It was in quite good agreement with the experimental data.

Measurement and Prediction of Autoignition Temperature of n-Propanol+n-Decane Mixture (노말프로판올과 노말데칸 혼합물의 최소자연발화온도 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.55-61
    • /
    • 2014
  • The autoignition temperature (AIT) of a material is the lowest temperature at which the substance will spontaneously ignite in the absence of an external ignition source such as a spark or flame. The AIT may be used as combustion property to specify operating, storage, and materials handling procedures for processs safety. This study measured the AITs of n-Propanol+n-Decane system from ignition delay time(time lag) by using ASTM E659 apparatus. The AITs of n-Propanol and n-Decane which constituted binary system were $435^{\circ}C$ and $212^{\circ}C$, respectively. The experimental AITs of n-Propanol+n-Decane system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D(average absolute deviation).

Measurement of Autoignition Temperature of o-Xylene+n-pentanol System (오토자일렌과 노말펜탄올 계의 최소자연발화온도 측정)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.66-72
    • /
    • 2006
  • An accurate knowledge of the AITs(autoignition temperatures) is important in developing appropriate prevention and control measures in industrial fire protection. The measurement of AITs are dependent upon many factors, namely initial temperature, pressure, vessel size, fuel/air stoichiometry, catalyst, concentration of vapor, ignition delay time. The values of the AITs used process safety are normally the lowest reported, to provide the greatest margin of sefety. This study measured the AITs of o-xylene+n-pentanol system from ignition delay time by using ASTM E659-78 apparatus. The experimental AITs of o-xylene and n-pentanol were $480^{\circ}C\;and\;285^{\circ}C$, respectively. The experiment AITs of o-xylene+n-pentanol system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D.(average absolute deviation).

Investigation of Reliability of Flash Points and Autoignition Temperatures of Acids (산류(Acids)의 인화점과 최소자연발화온도의 신뢰성 고찰)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.42-47
    • /
    • 2009
  • The flash point and the AIT(auto-ignition temperature) are the most important combustible properties used to determine the potential for the fire and explosion hazards of flammable material. In order to know the accuracy of data in MSDS(Material Safety Data Sheet), the flash point of n-acids were measured by using Pensky-Martens closed cup tester(ASTM D93), Setaflash closed cup tester(ASTM D3278), Tag open cup tester(ASTM D1310) and Cleveland open cup tester(ASTM D92). Also, the AIT of n-acids were measured by using ASTM E659-78 tester. The measured the flash points and the AIT were compared with literatures and MSDS in KOSHA. The measured the flash points and the AIT were different from those in literatures and MSDS. Therefore, This paper shows that it is needed to investigate the MSDS compatibility of n-acids for the fire safety objectives.