• Title/Summary/Keyword: 최대 흡수에너지

Search Result 209, Processing Time 0.025 seconds

Numerical Analysis of Differential Absorption Lidar for Measuring Atmospheric Pollutants (대기오염 측정용 DIAL시스템의 오차해석)

  • 박진화;이용우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.428-433
    • /
    • 2003
  • In this study, we composed algorithm of DIAL(Differential Absorption Lidar). we investigated the absorption spectrum of $O_3$, S $O_2$ and N $O_2$ dependent on wavelengths using data base UV-Bank and determine the optimized wavelength model. Here, the selected optimal wavelengths are 292.00(λ$_{on}$ ), 295.20(λ$_{off}$) for $O_3$, 299.38(λ$_{on}$ ), 300.05(λ$_{off}$) for S $O_2$ and 448.00(λ$_{on}$ ), 449.85(λ$_{off}$) for N $O_2$. In particular, we established the supposed model of DIAL and simulated the error of measuring distance using the selected optimal wavelength. In the model-I with telescope of 300 mm diameter, laser energy of 3 mJ and transmission of 10000 shots, maximum distances are 4 km for $O_3$ measurement and 5 km for S $O_2$ and N $O_2$ measurements. Also, in the model-II with telescope of 600 mm diameter, laser energy of 30 mJ and transmission of 10000 shots, maximum distances are 13 km for S $O_2$ and N $O_2$ measurements.ments.

  • PDF

Load Fidelity Improvement of Piecewise Integrated Composite Beam by Construction Training Data of k-NN Classification Model (k-NN 분류 모델의 학습 데이터 구성에 따른 PIC 보의 하중 충실도 향상에 관한 연구)

  • Ham, Seok Woo;Cheon, Seong S.
    • Composites Research
    • /
    • v.33 no.3
    • /
    • pp.108-114
    • /
    • 2020
  • Piecewise Integrated Composite (PIC) beam is composed of different stacking against loading type depending upon location. The aim of current study is to assign robust stacking sequences against external loading to every corresponding part of the PIC beam based on the value of stress triaxiality at generated reference points using the k-NN (k-Nearest Neighbor) classification, which is one of representative machine learning techniques, in order to excellent superior bending characteristics. The stress triaxiality at reference points is obtained by three-point bending analysis of the Al beam with training data categorizing the type of external loading, i.e., tension, compression or shear. Loading types of each plane of the beam were classified by independent plane scheme as well as total beam scheme. Also, loading fidelities were calibrated for each case with the variation of hyper-parameters. Most effective stacking sequences were mapped into the PIC beam based on the k-NN classification model with the highest loading fidelity. FE analysis result shows the PIC beam has superior external loading resistance and energy absorption compared to conventional beam.

Seismic Performance of a Hollow Composite Column (강합성 중공 기둥의 내진 성능)

  • Han, Taek Hee;Kim, Jung Hun;Lim, Nam Hyoung;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.215-226
    • /
    • 2008
  • A column test was performed for a hollow composite column to evaluate its seismic performance. The seismic performances of a hollow composite column and a reinforced concrete (RC) column were evaluated and compared by quasi-static tests. Lateral displacements and lateral loads of the column specimens were measured during tests. Ductilities, absorbed energy, equivalent damping ratios, and damage indices were calculated from the recorded data. From the test results, the hollow composite column showed a seismic performance superior to the column in terms of double moment capacity, ultimate energy, and energy absorption.

Evaluation of Seismic Performance for an Internally Confined Hollow CFT Column (내부 구속 중공 CFT 기둥의 내진 성능 평가)

  • Han, Taek Hee;Kim, Sung Nam;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2007
  • Column tests were performed for a new type of column, the internally confined hollow concrete filled tube column (ICH CFT column), to evaluate its seismic performance. The seismic performances for two types of ICH CFT columns and a general solid RC column were evaluated and compared by quasi-static tests. The displacements and the lateral loads of column specimens were measured during tests. Ductilities, absorbed energy, equivalent damping ratios, damage indices were calculated from recorded data. From the test results, the ICH CFT column shows superior seismic performances with double moment capacity and larger energy absorbing capacity over that of a solid RC column.

Kinetics of the Reaction of Carbon Dioxide with AMP and Piperazine (AMP에 Piperazine을 첨가한 CO2 흡수 동역학)

  • Jang, Sang-Yong;Song, Ju-Seouk;Cho, Sang-Won;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.3
    • /
    • pp.485-494
    • /
    • 2000
  • According to the worldwide interest in controlling $CO_2$ which contributes to green house effect. new techniques of reducing $CO_2$ are under development. We have developed new technique for reducing $CO_2$. In low $CO_2$ concentration. the chemical absorption method is useful. In this study. the kinetics of the reaction between $CO_2$ and the sterically hindered amine solution with piperazine. have been investigated from measurements of the rate of absorption of $CO_2$ in the stirred vessel that has a horizontal liquid-gas interface, in the temperature range $30{\sim}70^{\circ}C$. The experiments were carried out in the range 10.130~20.260 kPa of partial pressure of $CO_2$, and in aqueous $2.0kmol/m^3$ AMP solution with $0{\sim}0.4kmol/m^3$ piperazine The experimental results are as follows: 1) The absorption rate of $CO_2$ into aqueous AMP + piperazine solution is gett ng faster than that of aqueous AMP absorbents with temperature. Because the activation energy of piperazine 57.147 kJ/mol is higher than that of AMP 41.7kJ/mol. therefore the effect of piperazine on absorption rate increases with temperature. 2) Compared with aqueous AMP solution. the absorption rate of $CO_2$ into AMP + piperazine solution increases from 6.33% at $30^{\circ}C$ to 12% at $70^{\circ}C$, so AMP + piperazine solution is thought to be a better than AMP solution, 3) The reaction rate constants of piprazine in aqueous AMP solution with $CO_2$ have been determined as 217.21, 420.46, 707.00 and $3162.167m^3/kmol{\cdot}s$ respectively at 30, 40, 50 and $70^{\circ}C$ but these results are higher than those of Xu which were 186.7. 367.32. 693.01. $2207.65m^3/kmol{\cdot}s$ at 30, 40, 55, $70^{\circ}C$in aqueous MDEA solution. So the regression analysis of the data has led to the following equation In $k_p$ =28.324-6934.7/T.

  • PDF

Numerical Study of Concentration Characteristics of Linear Fresnel Reflector System (선형 프레넬 반사판 시스템의 집광 특성에 대한 수치해석 연구)

  • Lee, Hyun Jin;Kim, Jong Kyu;Lee, Sang Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.12
    • /
    • pp.927-934
    • /
    • 2015
  • In this study, we numerically investigated the concentration characteristics of a linear Fresnel reflector system that can drive a solar thermal absorption refrigeration system to be installed in Saudi Arabia. Using an optical modeling program based on the Monte Carlo ray-tracing method, we simulated the concentrated solar flux, concentration efficiency, and concentrated solar energy on four representative days of the year - the vernal equinox, summer solstice, autumnal equinox, and winter solstice. Except the winter solstice, the concentrations were approximately steady from 9 AM to 15 PM, and the concentration efficiencies exceed 70%. Moreover, the maximum solar flux around the solar receiver center changes only within the range of $13.0{\sim}14.6kW/m^2$. When we investigated the effects of the receiver installation height, reflector width, and reflector gap, the optimal receiver installation height was found to be 5 m. A smaller reflector width had a greater concentration efficiency. However, the design of the reflector width should be based on the capacity of the refrigeration system because it dominantly affects the concentrated solar energy. The present study was an essential prerequisite for thermal analyses of the solar receiver. Thus, an optical-thermal integration study in the future will assist with the performance prediction and design of the entire system.

Characteristics of Heat Absorption by Gas in a Directly-irradiated Fluidized Bed Particle Receiver (태양열 유동층 흡열기의 기체 열흡수 특성)

  • Park, Sae Han;Kim, Sung Won
    • Korean Chemical Engineering Research
    • /
    • v.59 no.2
    • /
    • pp.239-246
    • /
    • 2021
  • Characteristics of hydrodynamics and heat absorption by gas in a directly-irradiated fluidized bed particle receiver (50 mm-ID X 150 mm high) of SiC particles have been determined. Solid holdups of SiC particles show almost constant values with increasing gas velocity. Fine SiC particles (SiC II; dp=52 ㎛, ρs=2992 kg/㎥) showed low values of relative standard deviation of pressure drop across bed but high solids holdups in the freeboard region compared to coarse SiC particles (SiC I; dp=123 ㎛, ρs=3015 kg/㎥). The SiC II exhibited higher values of temperature difference normalized by irradiance due to the effect of additional solar heat absorption and heat transfer to the gas by the particles entrained in the freeboard region in addition to the efficient thermal diffusion of the solar heat received at bed surface. Heat absorption rate and efficiency increased with increasing the gas velocity and fluidization number. The SiC II showed maximum heat absorption rate of 17.8 W and thermal efficiency of 14.8%, which are about 33% higher than those of SiC I within the experimental gas velocity range.

Application and Improvement of Complex Frequency Shifted Perfectly Matched Layers for Elastic Wave Modeling in the Frequency-domain (주파수영역 탄성파모델링에 대한 CFS-PML경계조건의 적용 및 개선)

  • Son, Min-Kyung;Cho, Chang-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.3
    • /
    • pp.121-128
    • /
    • 2012
  • Absorbing boundary conditions are used to mitigate undesired reflections that can arise at the model's truncation boundaries. We apply a complex frequency shifted perfectly matched layer (CFS-PML) to elastic wave modeling in the frequency domain. Modeling results show that the performance of our implementation is superior to other absorbing boundaries. We consider the coefficients of CFS-PML to be optimal when the kinetic energy becomes to the minimum, and propose the modified CFS-PML that has the CFS-PML coefficient ${\alpha}_{max}$ defined as a function of frequency. Results with CFS-PML and modified CFS-PML are significantly improved compared with those of the classical PML technique suffering from large spurious reflections at grazing incidence.

Research of luminescent characteristics of ZnS:CuCl powder electroluminescent device according to the doping concentration of CuCl and frequency of the applied voltage (ZnS:Cu,Cl 후막형 전계 발광 소자의 CuCl 첨가량과 인가 전압의 진동수에 따른 발광 특성 연구)

  • Park, Yong-Kyu;Sung, Hyun-Ho;Cho, Whang-Sin;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.22-25
    • /
    • 2000
  • ZnS:Cu,Cl 형광체의 여기 및 발광 스펙트럼 측정 결과 주게인 $Cl^-$ 이온과 받게인 $Cu^+$ 이온 사이의 흡수와 발광에 기인하는 peak과 국소화된 발광 중심인 $(CU_2)^{2+}$ 이온의 흡수와 발광에 기인하는 peak이 관측되었다. CuCl의 첨가량이 증가함에 따라 $Cu^+$ 이온의 농도가 증가하게 되어 $(Cu_2)^{2+}$ 이온에 기안하는 발광으로부터 공명 에너지 전달 (Resonant Energy Transfer)의 확률이 높아지기 때문에 513 nm를 중심으로 하는 발광의 세기가 증가하게 된다. 자체 제작한 ZnS:Cu,Cl 형광체를 이용하여 제작한 소자의 휘도 측정결과 400 Hz, 100 V 에서 CuCl 의 첨가량이 0.2 mole% 일 때 휘도가 최대였고, 진동수가 증가함에 따라 휘도가 포화되는 현상이 나타났다. CuCl의 첨가량이 증가함에 따라 513 nm를 중심으로 하는 발광이 강해지고 CIE 좌표값이 녹색영역으로 이동하게 된다. 진동수가 증가하면 인가된 전압의 유지 시간이 짧아지게 되어 발광의 감쇄시간이 긴 513 nm를 중심으로 하는 발광보다 감쇄시간이 짧은 458 nm를 중심으로 하는 발광이 강해지게 되고, CIE 좌표값이 청색영역으로 이동하게 된다.

  • PDF

A Study on the Axial Collapse Characteristics of Thin-Walled Members for Vehicles on the Variation of Section Shapes (차체구조용 박육단면부재의 단면형상변화에 따른 축압궤 특성에 관한 연구)

  • 이길성;백경윤;차천석;정진오;양인영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1549-1552
    • /
    • 2003
  • The front-end side members of automobiles absorb most of the energy in a front-end collision. The front-end side members are required to have a high stiffness together with easiness to collapse sequentially to absorb more impact energy. The axial static collapse test (5mm/mim) was conducted by using UTM with respect to the single hat shaped section members which are the standard section shape of the spot welded section members, to the single cap shaped section members, to the double cap shaped section members and to the double hat shaped section members whose section shape are changed in order to give more stiffness. As a result of test, the energy absorbing characteristic was analyzed for different section shapes. That is, it was analyzed that the change of section shape influenced the absorbing energy, the mean collapse load and the maximum collapse load, and that the relation between the change of section shape and the collapse mode.

  • PDF