• Title/Summary/Keyword: 최대환기량

Search Result 83, Processing Time 0.029 seconds

Effects of the Geometry and Location of an Vertical Opening on the Fire Characteristics in the Under-Ventilated Compartment Fire (환기부족 구획화재에서 수직 개구부의 형상 및 위치가 화재특성에 미치는 영향)

  • Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.20-29
    • /
    • 2013
  • To investigate numerically the effects of geometry and location of vertical opening on the thermal and chemical fire characteristics in full-scale under-ventilated compartment fires, the ventilation factor ($A\sqrt{h}$) to estimate a theoretical maximum inflow of ambient air and the mass loss rate in a heptane pool fire were fixed for all cases. It was shown that variations in door geometry affected significantly the change in thermal and chemical characteristics inside the compartment. Variations in window location resulted in the complex change in additional fire characteristics including the fire duration time and recirculating flow structure. These results were analyzed in details by the multi-dimensional flow and fire characteristics including the vent flow and fuel/air mixing phenomena.

Study on the Ventilation System Applicability of High-rise Hog Building for Growing-fattening (고상식 육성비육돈사에 적합한 환기시스템에 관한 연구)

  • Yoo, Yong-Hee;Song, Jun-Ik;Choi, Dong-Yoon;Chung, Eui-Soo;Jeon, Kyoung-Ho;Lee, Poong-Yeon;Kim, Sang-Woo;Jeung, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2010
  • The goal of this study was to develop a suitable ventilation system for high-rise hog building (HRHB) for growing-fattening with combined slatted floor pen in second story and in situ manure management system in Korea. The HRHB was constructed as 29m long, 9m wide and 7.6m high for outer dimension with an indoor height of 3.1m and 2.4 for lower and upper floor, respectively. Ventilation systems for each treatment were installed in separated rooms of HRHB. The ventilation types installed in each room were following 3 types: ventilation type 1 (V1), where air was pulled through a circular duct inlet and exhausted by fans; ventilation type 2 (V2), where air was pulled through eave inlet (side ceiling inlet) and exhausted by fans; and ventilation type 3 (V3), where air was pulled through baffled ceiling inlet and exhausted by fans. For each ventilation system, investigated air velocity under minimum, medium and maximum ventilation ratio and air flow pattern inside. The results were as follows; For air flow pattern from top to bottom, V1 showed a homogeneous vertical type, V2 showed a bilateral symmetry type and V3 showed an vertical umbrella type. Under minimum ventilation ratio, air velocity in upper floor (80cm above the slated floor) was similar for V1, V2, and V3. Under maximum ventilation ratio, air velocity in upper floor was undeviating for V1 (0.10~0.26m/s) and varied for V2 (0.12~0.63m/s) while those for V3 was relatively slow and less varied (0.07~0.15m/s). In conclusion, Duct inlet type (V1) can be applied to the development of a new HRHB with additional evaluations such as field test hog feeding.

Effect of the Characteristic Length Scale on the Grid Dependency of FDS model (특성길이에 따른 FDS 모델의 격자 의존성)

  • Kim, Sung-Chan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.66-69
    • /
    • 2012
  • Field Model에 의한 화재해석방법은 화재현상을 지배하는 망정식윤 직접 해석하기 때문에 Zone model에 비해 공간내의 상세 정보를 제공함과 동시에 다양한 화재형태에 내해 보편적인 적용이 가능하다. Field model은 해석영역을 구성하는 격자점에 대해 이산화된 지배 방정식을 해석하는 과정에서 차분방법이나 격자의 크기에 따라 수치오류가 발생할 수 있다. 특히 격자수는 계산시간에 영향을 미치는 가장 중요한 인자이기 때문에 효율적인 계산을 위해서는 격자크기의 최적화가 이루어져야 한다. 본 연구에서는 구획공간 화재의 최적 격자크기 선정을 위해 격자해상도(Grid Resolution)에 따른 해석결과의 독립성을 비교분석하고 이를 통해 구획공간화재에 대한 격자 최적화 방법에 대해 논의하고자 한다. 화재크기 및 특성 길이에 따른 격자의존성을 파악하기 위해 ISO-9705 표준화재실에 내해 적용된 격자크기는 최소 3 cm에서 최대 30 cm까지 총 7 종류의 격자크기에 대해 FDS 해석이 수행되었다. 해석결과, 환기량이 충분한 화재에 대해서도 격자해상도가 16보다 작은 경우 출입구의 유동은 격자에 따른 독립성을 확보하지 못하는 것으로 나타났으며 화재발열량이 증가함에 따라 독립적인 해석해를 얻기 위해서는 더 큰 격자해상도를 요구하는 것으로 나타났다. 따라서 현재 실무에서 격자최적화를 위해 사용되고 있는 격자선정법에 대한 재검토가 필요하며 화재특성 및 구획공간 조건에 따른 최적격자 조건을 도출하기 위한 추가적인 연구가 필요하다.

  • PDF

Design of Large Capacity Clean Air Heater (대용량 청정 공기 가열 장치 설계)

  • Kim, Jeong-Woo;Jung, Kwang-Soo;Jeon, Min-Joon;Lee, Kyu-Joon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.115-118
    • /
    • 2010
  • 2 Types of heater (Vitiated Type, Clean Air Type) in order to increase the temperature for a test are used for industry. In this report, large capacity clean air type heater was designed. Heater capacity and LNG consumption rate can be calculated by the air mass flow and heater inlet/outlet temperature. The heater is composed by Burner, Furnace, Heat Exchanger, and Stack. The hot air from the burner and cold air from the tube inlet exchange their heat indirectly in the heat exchanger, so the desired temperature can be achieved at the exit of the tube.

  • PDF

The Effect of Aerobic Exercise on Exhaled Carbon Monoxide and Cardiorespiratory Function of Female College Students who Participated in Nonsmoking (유산소운동이 금연에 참여한 여자대학생의 호기 일산화탄소 및 호흡순환기능에 미치는 영향)

  • Kim, Seung-Suk
    • Journal of Industrial Convergence
    • /
    • v.18 no.5
    • /
    • pp.30-35
    • /
    • 2020
  • The purpose of this study is to find out the effect of aerobic exercise through convergence on exhaled carbon monoxide and cardiorespiratory function of female college students who participated in nonsmoking. The subjects were female college students from University D in Metropolitan City D, and those who started smoking 2 years ago and who do not engage in regular physical activities were first selected, and a total of 18 people who indicated their intention to participate in the experiment were selected to receive a pledge of nonsmoking and consent to the experiment. The selected subjects were classified into 9 people in the exercise group and 9 in the control group by wireless assignment, and individual exercise intensity was set through the maximum exercise load test to establish an accurate exercise program. Individual exercise intensity is set to 50%HRmax for 1-3 weeks, 60%HRmax for 4-6 weeks, 70%HRmax for 7-9 weeks. In order to apply the correct exercise intensity during exercise, a Polar heart rate monitor was used for control and the following results were obtained. First, the change in carbon monoxide decreased by three levels from 21.17±3.67ppm (Red 2 16-25ppm, habitual smokers) before participation in the exercise group that participated in aerobic exercise for 9 weeks to 1.36±0.76ppm (Green, 0-6ppm, non-smokers) after participation, and the control group also showed the same effect from 22.35±2.08ppm (Red 2 16-25ppm, habitual smokers) to 2.81±0.51ppm (Green, 0-6ppm, non-smokers). Second, the change in cardiorespiratory function showed a significant increase in all of the maximum oxygen intake, maximum heart rate, and maximum ventilation in the exercise group who participated in aerobic exercise for 9 weeks, but there was no significant change in the control group. Therefore, aerobic exercise showed the effect of improving the cardiorespiratory function by releasing carbon monoxide and supplying sufficient oxygen to various organs.

Correlation of Tracheal Cross-sectional Area with Parameters of Pulmonary Function in COPD (만성 폐쇄성 폐질환에서 기관의 단면적과 폐기능지표와의 상관관계)

  • Lee, Chan-Ju;Lee, Jae-Ho;Song, Jae-Woo;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Chung, Hee-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.628-635
    • /
    • 1999
  • Background : Maximal expiratory flow rate is determined by the size of airway, elastic recoil pressure and the collapsibility of airway in the lung. The obstruction of expiratory flow is one of the major functional impairments of emphysema, which represents COPD. Nevertheless, expiratory narrowing of upper airway may be recruited as a mechanism for minimizing airway collapse, and maintaining lung volume and hyperinflation by an endogenous positive end-expiratory pressure in patients with airflow obstruction. We investigated the physiologic role of trachea in respiration in emphysema. Method : We included 20 patients diagnosed as emphysema by radiologic and physiologic criteria from January to August in 1997 at Seoul Municipal Boramae Hospital. Chest roentgenogram, high resolution computed tomography(HRCT), and pulmonary function tests including arterial blood gas analysis and body plethysmography were taken from each patient. Cross-sectional area of trachea was measured according to the respiratory cycle on the level of aortic arch by HRCT and calibrated with body surface area. We compared this corrected area with such parameters of pulmonary function tests as $PaCO_2$, $PaO_2$, airway resistance, lung compliance and so on. Results : Expiratory cross-sectional area of trachea had significant correlation with $PaCO_2$ (r=-0.61, p<0.05), $PaO_2$ (r=0.6, p<0.05), and minute ventilation (r=0.73, p<0.05), but inspiratory cross-sectional area did not (r=-0.22, p>0.05 with $PaCO_2$, r=0.26, p>0.05 with $PaO_2$, and r=0.44, p>0.05 with minute ventilation). Minute ventilation had significant correlation with tidal volume (r=0.45, p<0.05), but it had no significant correlation with respiratory frequency (r=-0.31, p>0.05). Cross-sectional area of trachea had no significant correlation with other parameters of pulmonary function including $FEV_1$, FVC, $FEV_1$/FVC, peak expiratory flow, residual volume, diffusing capacity, airway resistance, and lung compliance, whether the area was expiratory or inspiratory. Conclusion : Cross-sectional area of trachea narrowed during expiration in emphysema, and its expiratory area had significant correlation with $PaCO_2$, $PaO_2$, and minute ventilation.

  • PDF

The Effect of Respiratory Muscle Training in Patients with Chronic Obstructive Pulmonary Disease - Preliminary Study - (만성 폐쇄성 폐질환 환자에 있어서 호흡근육 훈련의 효과에 관한 실험적 연구)

  • Kim Mae-Ja
    • Journal of Korean Academy of Nursing
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 1986
  • The effect on strength and endurance training (SET) (2 patients) were compared with those of strength training(ST) (2 patients) in patients with-chronic obstructive pulmonary disease. The result of training was assessed by 4 tests: maximal inspiratory pressure(PImax), sustainable inspiratory pressure (SIP), maximal voluntary ventiiation(MVV) and bronchitis-emphysema symptom checklist(BESC). Measurements were repeated before and after training per week for 6 weeks. The SET group performed inspiratory muscle training, using a inspiratory muscle trainer 30 minutes per day, 6 days per week and performing endurance training-12-minute walking-2 days per week for 6 weeks, whereas the ST-only group trained for 30 minutes daily, 6 days per week using inspiratory muscle trainer. SET was no significant increase in exercise performance, whereas ST produced an increase in SIP and a decrease in BESC. There was significant change in BESC betweet the two groups. A simple at home training program using inspiartory muscle trainer was more effective than that of SET program in improving exercise performance of some patients with COPD.h COPD.

  • PDF

The Effect of Aerobic Exercise and CWT on Cardiorespiratory Function and Body Composition For Female Workers (유산소운동과 Circuit Weight Training이 직장여성의 호흡순환기능 및 신체조성에 미치는 영향)

  • Lee, Jae-Gue
    • Journal of Life Science
    • /
    • v.13 no.4
    • /
    • pp.448-456
    • /
    • 2003
  • The purpose of this study was to determine changes in their cardiorespiratory function and body composition in female workers after aerobic exercise and circuit weight training. The subjects of this study were 16 female workers in B city and was divided into exercise and control groups which were composed of 8 people respectively. The members of exercise group had aerobic exercise and circuit weight training an hour a day, 5 days per week, for 8 weeks while controled group did not. Both groups were pretested and posttested, and the results of this study on cardiorespriatory function and body composition are as follows. Exercise group showed significant decrease in heart rate at rest(p<.001). Exercise group showed significant increase in the oxygen uptake at rest, in the maximum oxygen uptake and in the vital capacity(p<.001). Exercise group showed significant decrease in the %fat and fat(p<.001). Exercise group showed significant increase in the %LBM and LBM(p<.001).

Optimum Size Combination of Heat Exchangers in a Small Gifford-Mchon/ Joule-Thomson Refrigerator (소형 Gifford-McMahon/Joule-Thomson 냉동기에서 열교환기의 최적 조합)

  • 김영률;이상용;장호명
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2196-2202
    • /
    • 1992
  • The optimum size combination of heat exchangers in a Joule-Thomson(J-T) circuit for small cryogenic systems has been sought analytically, when the circuit is combined with a two-stage Gifford-McMahon(GM) cooler. Full thermodynamic cycle analysis was carried out to predict the performance of the combined refrigeration system. Relevant convective heat transfer coefficients, the computerized properties of helium, and the refrigeration capacity curve of a typical GM cooler have been used in the analysis. The result showed that, by changing the configuration(heat exchanger area ratio) of the system, the performance of the commonly-used GM/J-T refrigerators could be optimized. For the maximum refrigeration performance, the optimum mass flow rate of the refrigerant and the relative size between the heat exchangers have been obtained, when the cooling load was 0.1W at 3.995K with the total heat exchanger area being given.

Breathing Reserve Index at Anaerobic Threshold of Cardiopulmonary Exercise Test in Chronic Obstructive Pulmonary Disease (만성폐쇄성 폐질환의 운동부하 심폐기능검사에서 무산소역치 예비호흡지수의 의의)

  • Lee, Byoung-Hoon;Kang, Soon-Bock;Park, Sung-Jin;Jee, Hyun-Suk;Choi, Jae-Chol;Park, Yong-Bum;Ahn, Chang-Hyuk;Kim, Jae-Yeol;Park, In-Won;Choi, Byung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.795-802
    • /
    • 1999
  • Objective : Cardiopulmonary exercise test is a useful tool to evaluate the operative risk and to plan exercise treatment for the patients with chronic obstructive pulmonary disease(COPD). In cardiopulmonary exercise test, most of the measured parameters are recorded at the time of peak exercise, which are hard to attain in COPD patients. So we evaluated the usefulness of the parameter, breathing reserve index(BRI=minute ventilation [$V_E$]/maximal voluntary ventilation[MVV]) at the time of anaerobic threshold($BRI_{AT}$) for the differentiation of COPD patients with normal controls. Methods : Thirty-six COPD patients and forty-two healthy subjects underwent progressive, incremental exercise test with bicycle ergometer upto possible maximal exercise. All the parameters was measured by breath by breath method. Results : The maximal oxygen uptake in COPD patients (mean$\pm$SE) was $1061.2{\pm}65.6ml/min$ which was significantly lower than $2137.6{\pm}91.4ml/min$ of normal subjects(p<0.01). Percent predicted maximal oxygen uptake was 54.3% in COPD patients and 86.0% in normal subjects(p<0.01). Maximal exercise(respiratory quotient; $VCO_2/VO_2{\geq}1.09$) was accomplished in 7 of 36 COPD patients(19.4%) and in 18 of 42 normal subjects(42.9%). The $BRI_{AT}$ of COPD patients was higher($0.50{\pm}0.03$) than that of control subject($028{\pm}0.02$, p<0.01), reflecting early hyperventilation in COPD patient during exercise. The correlation between $BRI_{AT}$ and BRI at maximal exercise in COPD patients was good(r=0.9687, p<0.01). Conclusion : The $BRI_{AT}$ could be a useful parameter for the differentiation of COPD patients with normal controls in the submaximal cardiopulmonary exercise test.

  • PDF