• Title/Summary/Keyword: 최대치수

Search Result 266, Processing Time 0.027 seconds

Characteristic of Microcracks with Mixing Proportional Properties of Concrete (미세균열이 콘크리트의 염소이온 침투에 미치는 영향 III; 배합조건 특성에 따른 미세균열의 특성)

  • Yoon, In-Seok;Kim, Young-Geun;Park, Ki-Bong
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.4
    • /
    • pp.469-475
    • /
    • 2008
  • It is obvious that chloride penetration through cracks can threaten the durability of concrete substantially, according to the previous studies of author. It was proposed that crack depth corrseponded with critical crack width from the surface is a crucial factor in view of durability design of concrete structures. It is now necessary to deal with chloride penetration through microcracks characterized with the mixing features of concrete. The purpose of this study is examining the effect of mix proportional features of concrete such as coarse aggregate, high strengtherize of concrete and reinforcement of steel fiber on chloride penetration through cracks. Although small size of coarse aggregate can lead to many microcracks in concrete, the cracks should not impact on chloride penetration directly. On the contrary, chloride should penetrate through cracks easily in concrete with a large size of coarse aggregate because mixrocracks are connected to each other. Second, high strength concrete has an excellent performance to resist with chloride penetration. However, for cracked high strength concrete, its performance is reduced upto the level of ordinary concrete. Finally, steel fiber reinforcement is effective to reduce chloride penetration through cracks because steel fiber reinforcement can lead to reduce crack depth significantly.

An Experimental Research on Changes of Properties in Flow by Slump Flow Type Concrete Mix Design Adjustment of the Way according to the Various Gmax Size (굵은 골재 최대치수 변경에 따른 슬럼프 플로 타입 콘크리트의 배합조정방법별 유동특성변화에 대한 실험적 연구)

  • Kwon, Hae-Won;Seo, Il;Lee, Jin-Woo;Park, Hee-Gon;Lee, Jae-Sam;Lee, Jong-Seo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05b
    • /
    • pp.67-68
    • /
    • 2010
  • Recently, there were not enough studies regarding the mix adjustment and changes of normal physical properties of slump flow type concrete in domestically. Therefore in this paper, it is aimed securing the fundamental data about flow its mix design method by experimental research. The experiment includes the adjustment of the way for slump flow type concrete by the variation of size of coarse aggregate. In the result, it is advisable raising the ratio of fine aggregate and unit water amount by considering the specific surface when increasing the Gmax size.

  • PDF

Fracture Toughness of Concrete Brazilian Disk according to Maximum Size of Coarse Aggregate (굵은골재의 최대치수에 따른 콘크리트 브라질리언 디스크의 파괴인성)

  • Lee, Seung-Hoon;Kim, Hee-Sung;Jang, Hee-Suk;Jin, Chi-Sub
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.185-196
    • /
    • 2006
  • Fracture toughness is a material property for crack initiation and propagation in fracture mechanics. For mode I fracture toughness measurement in concrete, RILEM committees 89-FMT proposed three-point bend tests based on the two-parameter fracture model. But, there is no proposed test method as a standard for mixed mode test for now. And RILEM three-point bend test procedure is complicate. Therefore, in this study, brazilian disks of various size were designed as the concrete with a similar specified concrete strength and maximum size of coarse aggregate($G_{max}$) were respectively 20mm and 40mm. And mode I fracture toughness of brazilian disks was compared with that of RILEM three-point bend test. As a result, it was suggested appropriate size(thickness, diameter) and notch length ratio of brazilan disk on the $G_{max}$. And it was verified that stress intensity factors for mixed mode can be easily calculated with the disk specimen. Stress intensity factors of a concrete brazilian disk were evaluated with finite element analysis and five terms approximation for comparison.

Optimization of Injection Molding Process using the IDESIGN Program (IDESIGN 프로그램을 이용항 사출성형공정의 최적화)

  • 민병현
    • The Korean Journal of Rheology
    • /
    • v.9 no.2
    • /
    • pp.66-72
    • /
    • 1997
  • 사출성형품의 품질특성으로 외관, 치수, 기계적 강도 등이 있으나 조립부품으로써 사 될경우에는 치수가 주요한 품질이 된다. 성형품은 용융수지의 특성상 사출공정 중 수축을 일으키므로 이를 고려해서 금형설계가 이루어지지만 실제 사출과정에서 공정변수를 최적화 하여 관리하지 않으면 허용오차 내의 치수를 얻기가 힘들다. 본 논문에서는 주요조립부의 치수가 허용오차 내에서 얻어지도록 설계시 적용된 수축률과 측정된 수축률의 차이를 목적 함수로 하여 최소화 시키며 반복이차계획 알고리즘을 채택한 IDESIGN 프로그램을 이용해 최적 사출성형조건을 구하였다. 제약조건은 성형품의 부위별 수축률 편차 및 싱크마크 깊이 가 공정변수의 부등호 제약식으로 도출되었고 성형이 이루어지는 공정변수의 상하한 값이 최대 및 최소 경계값으로 적용되었다.

  • PDF

Estimation of Probable Maximal Flood on Ungauged Small Basin (미계측 소유역의 가능최대홍수량 산정)

  • Hwang, Man-Ha;Lee, Bae-Sung;Yoo, Yang-Soo;Lee, Sang-Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1216-1220
    • /
    • 2006
  • 최근 들어 기상이변으로 인해 집중호우가 빈번히 발생하여 막대한 홍수피해를 야기하고 있으며, 이에 자연재해에 대한 방재대책의 중요성 및 수공구조물들의 설계빈도를 상향조정하는 등의 대책마련이 절실히 요구되고 있는 실정이다. 특히 2002년 여름 강릉지역에 발생한 태풍 '루사'로 인한 집중호우는 기존 PMP(가능 최대강수량) 규모를 초과하는 사상 초유의 24시간 최대 강수량(880mm)을 기록하여 기존 댐 등과 같은 수공구조물의 설계기준에 대한 재고가 불가피 하게 되었다. 이에 본 연구에서는 미계측 유역인 상관저수지 유역을 대상으로 지속시간별 PMP를 산정한 후 임계지속시간을 고려한 PMF(가능최대홍수량)를 산정하여 유역내 대표적인 수공구조물인 저수지의 수문학적 치수안정성 여부를 검토하였다. 분석 대상유역인 상관저수지 유역의 PMP는 전국 전계절별 PMP도로부터 호우중심의 PMP와 유역중심의 PMP를 동일하게 하여 지속시간별 PMP를 산정하였다. 산정된 PMP로부터 Huff의 4분위법을 이용하여 강우를 시간분포 시킨 후 상관저수지 유역의 PMF를 산정하였으며, 이 때 이용된 유역의 홍수량추정 기법으로는 Clark 단위도법이다. 또한 본 연구에서는 수공구조물의 치수안정성을 검토하기 위하여 HEC-5모형을 이용한 저수지 홍수추적을 실시하였으며, 검토 결과 상관저수지의 수문학적 안정성은 확보된 것으로 분석되었다.

  • PDF

An Experimental Study on the Properties of Concrete according to G/S ratio classified by Maximum Size of Coarse Aggregate (굵은골재 최대치수별 굵은골재/잔골재 용적비에 따른 콘크리트의 특성에 관한 실험적 연구)

  • Kim, Duk-Hyun;Lee, Sang-Soo;Song, Ha-Young;Kim, Eul-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.2
    • /
    • pp.97-103
    • /
    • 2004
  • In this study, the experiment was carried out to investigate and analyze the influence of coarse aggregate's mix ratio and maximum size on the properties of concrete. The main experimental variables were water/cement ratio 45% and 65%, coarse aggregate/fine aggregate ratio 90%, 130% and 170%, maximum size of coarse aggregate 15mm, 25mm and 40mm. According to the test results, the principal conclusions are summarized as follows. 1) The slump and flow of fresh concrete were found to be higher in the order of G/S ratio 170%, 130%, 90%, also in the order of maximum size 40mm, 25mm, 15mm. 2) The compressive strength of hardened concrete were found to be higher in the order of G/S ratio 170%, 130%, 90%, also in the order of maximum size 15mm, 25mm, 40mm.

Development of an Electric Pulp Tester with Constant Current Source (정 전류원을 이용한 치수 검사기의 개발)

  • 김재성;남기창;김수찬;이승종;김덕원
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.2
    • /
    • pp.61-68
    • /
    • 2004
  • Electric stimulation of teeth has been used for assessing pulp vitality. The principle is based upon the assumption that a subject feels the pain produced by electrical current stimulation of intradental nerve. Because of very high and wide range of impedance of the enamel, it is very difficult to determine stimulation levels regardless of teeth status. Most pulp testers adopt voltage stimulation method and thus, their stimulating threshold levels significantly depend on each individual. Therefore, a constant current stimulator is necessary to minimize the effect of wide variation due to different enamel thickness. And it is also necessary to test teeth vitality with a wide current range regardless of tooth impedance. In this study, we constructed a burst-wave type pulp tester to reduce the pain using a current stabilizing circuit with the maximum current of 150 uA.

Establishment of allowable flooding scale in urban basin in response to extreme precipitation caused by climate change (기후변화에 따른 강수의 극단화에 대응한 도시유역의 허용침수규모 설정)

  • Cho, Woncheol C.;Ahn, Jeonghwan H.
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.75-75
    • /
    • 2021
  • 본 연구는 기후변화에 따른 강우현상의 극한화에 대응한 도시치수규모 설정 방안에 대한 연구이다. 발생가능한 모든 강우상태를 강우지속시간과 강우량 매트릭스로 구성하고 모든 강우상태에 대한 침수규모를 사전에 산정한 후 도시침수 상태를 추정하는 2변수(강우량, 강우지속시간) 회귀식을 개발하였다. 치수규모 결정을 위해서 지금까지 사용해 오던 "발생빈도" 기준의 극치통계의 개념적, 공학적 의미를 재해석하여 물리적으로 의미가 있는 "침수 특성치" 기준으로 대전환하자는 것이다. 기술적으로 가능해졌기 때문이다. 도시유역의 침수를 정량적(침수심, 침수면적)으로 모의할 수 있는 방법을 제시하기 위한 침수상태의 기준이 될 침수특성치로는 관로첨두유출량, 최대침수면적, 침수총량, 평균침수심, 특정지점의 최대침수심, 특정지점의 침수지속시간 등 6가지를 선정하였다. 우리나라에서 발생가능한 모든 강우상태에 대한 침수 발생 가능성을 점검하여 침수특성치를 분석하고 해당 유역의 "물리적/사회적 특성"을 고려한 "사회적 합의"에 의해 "감당할 수 있는 피해의 정도"에 맞춘 도시유역 치수계획규모를 설정하는 방안을 확립하는 것이다. 또 결과로 구해지는 다음과 같은 형태의 유역별 침수특성치 산정식(2변수 회귀식)을 각 유역별로 구해 놓으면 기상예보(강우지속시간-강우량)에 따라 유역의 침수 특성치를 쉽게 추정하여 사전에 확립해둔 방재대책을 시행할 수 있게 한다.

  • PDF

Economic Analysis of Maintenance Planning Area using Multi-Dimensional Flood Damage Analysis (다차원 홍수피해 산정방법을 이용한 정비계획지구의 경제성 분석)

  • Gwon, Yong Hyeon;Choi, Gye Woon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.438-438
    • /
    • 2018
  • 최근 여름철 강우로 인한 도시시설과 공공시설의 피해가 급증화되고 대형화 되면서 이에 대한 피해를 최소화하여 피해를 최대한 줄이는 객관적인 판단이 필요하다. 특히, 하천정비계획지구의 경우에는 치수사업의 타당성을 판단할 수 있는 경제성분석이 중요하다. 치수사업의 경제성분석 방법을 연구할 수 있는 방법으로는 다차원 홍수피해 산정방법((Multi-Dimension Flood Damage Assessment; MD-FDA)이 치수사업의 경제성 분석을 계량 평가하는 방법으로 주로 사용되고 있다. 다차원 홍수피해 산정방법은 홍수피해 유형과 토지이용을 고려한 침수피해액 산정이 가능한 경제성 분석 방법이다. 본 연구에서는 SG정비계획지구 13개소(축제 및 확폭지구 4개소, 보축 및 하도준설지구 9개소)에 대해 다차원 홍수피해 산정방법을 이용하여 치수경제성 분석을 실시하였다. 치수경제성 분석을 위해 해당지역의 주거지역, 농업지역, 산업지역의 대상자산을 분석하여 자산가치를 분석하고 빈도별 홍수량에 대응하는 침수심과 침수편입율을 추정하여 침수지역의 자산액을 조사하였다. 조사된 자료를 활용하여 사업 시행전후에 대한 직접피해액을 자산피해와 인명피해로 구분하여 치수경제성 대상지구의 홍수규모별 예상피해액을 산정하였다. 그리고 피해액을 근거로 하여 비용편익비(B/C)를 활용하여 최종적인 치수경제성 분석을 진행하였다. 분석결과, 대상지구 3개 지구에서 B/C가 1이상의 값을 가져 사업의 경제성이 높은 것으로 나타났다. 분석결과를 활용하여 B/C가 1이하인 계획지구에 대해서도 치수사업의 일관성 및 지역주민의 안정된 생활보장을 위해 지속적인 사업의 시행이 필요할 것으로 판단된다.

  • PDF

A Study on Flooding Characteristic Value for the Decision Method of an Urban Basin Design Magnitude (도시유역의 치수계획규모 결정을 위한 침수특성치에 관한 연구)

  • Ahn, Jeonghwan;Cho, Woncheol;Kim, Hosoung
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.10
    • /
    • pp.1035-1041
    • /
    • 2012
  • This paper is on the decision of design magnitude for flood control of urban basin, based on flooding characteristic values. In Korea, a design magnitude for flood control is established based on peak discharge of the outlet of basin. However, this method is inappropriate in an urban basin because sewerage only can flow out as much as it could and other discharge overflow to basin. In order to calculate a design magnitude for flood control of an urban basin, flooding characteristic values (peak discharge of pipe, average flooded depth, maximum flooded depths of an important point, flooded area, flooded volume, flooded time) were used as a tool. Using the Gwanghwamun Square as an example, a methodology was proposed that used XP-SWMM 2010 model as a platform to predict urban flood disaster. It can help other local government and residents to better understand, prepare for and manage a flood in urban environments.