• Title/Summary/Keyword: 촬영

Search Result 8,342, Processing Time 0.037 seconds

A Quality Assurance on Digital Chest Radiography in Medical Institution for Pneumoconiosis : Compared with Analog Radiography (진폐요양기관의 흉부 디지털촬영과 아날로그촬영의 정도관리 비교)

  • Lee, Won-Jeong;Ko, Kyung-Sun;Park, Jai-Soung;Kim, Sung-Jin;Chu, Sang-Deok;Park, So-Young;Choi, Byung-Soon
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.85-91
    • /
    • 2010
  • Digital radiography has been replacing rapidly the analog radiography for diagnosis of pneumoconiosis. The purpose of this study is to compare quality control of digital radiography (DR) and analog radiography (AR) for chest radiography in medical institution for pneumoconiosis (MIP) For the first time, we visited MIP to evaluate the chest radiography which is used for patients with pneumoconiosis, including equipment, technical parameters and reading environment. There were 33 institutions. DR and AR were installed in 24 and 9 institutions, respectively. Between DR and AR, we compared the radiological technique (RT), image quality (IQ) and reading environment (RE) to use the guideline published by Occupational Safety and Health Research Institute (OSHRI). The image quality was rated by two experienced chest radiologists for pneumoconiosis with certified from OSHRI. The chest radiography equipment was not significantly difference between AR and DR, but there were significantly difference in tube voltage and grid ratio used for chest radiography except to tube current, exposure time. Statistically, DR is significantly higher in RT(70.3 vs. 43.8, p = 0.009), RE(77.7 vs. 33.3, p = 0.004) than AR, but it's not significantly difference in IQ (65.6 vs. 52.8, p = 0.050). AR and DR in RT were passed 33.3%, 75.0% respectively (p = 0.044) and 44.4%, 79.2% (p = 0.090) in IQ and 44.4%, 91.7% (p = 0.009) in RE. In MIP, DR needs to replace AR in diagnosis of pneumoconiosis.

Radiographic Status of the Visited Patients at University Hospital Emergency Room (한 대학병원 응급실 내원환자의 방사선촬영 실태)

  • Ahn, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.81-92
    • /
    • 2011
  • This study was carried out to improve service efficiency and to cope with a emergency situation in emergency radiography, through analysis of the radiographic distriution and literature cited about emergency care. Data collection of radiographic distribution was surveyed for 1270 emergency outpatients who visit during JAN, 2009at ER of the general hospital in Gwang city. The results is as follows : Emergency radiography rate of simple radiography was 56.6%, special radiography 2. 5%, CT 34.2%, and ultrasonography 6.7%, In simple radiography rate. a high rate was distributed on male(63.6%), thoracicsurgery part(90.0%), admission patient(77.9%), and long stayed patient at ER. In special raiography rate, a high rate was obsurved in urologic part(28.6%), and in CT rate, observed neurosurgerty part(49.2%) and neurologic part(36.7%). Ultrasonography rate was high for female(8.8%) and internal medicine part(15.9%). There are distributed regional radiography rate in radio-graphic type that chest(55.3%) is high in the simple radiography, urinary system(1.2%) in the special study, and brain(40.0%) in the CT. Regional radiography rate according to diagnostic department also was showed highly for head(64.6%) in neuro surgery, chest(90.0%) in thoracic surgery, abdomen(58.0%) in general surgery, spine(40.0%) in neuro surgery, and pelvis(15.9%), upper extrimity(20.5%), and lower extrimity(31.8%) in orthopedic surgery each. Mean radiographic case number per patient of simple radiography was sinificant on sex, age, transfer relation in both total and radiopraphic patients(p<0.05). Mean radiographic case number was highly distributed on male(2.2 case number) in sex, on thirties(2.7) in age, transferred patient(2.7) in patient type, and on nurosurgery(3.4) in diagnostic charged part. Total radiographic case number in regional party was highly distributed on chest(998 case number.) Considering the above results, emergency radiographer should take care of the elder patient in emergency radiography and get hold of injury mechanism to decrease possible secondary injury during radiography. Because of high radiography rate of urinary system in special study, related instrument. All radiographer who take charge emergency patient should cope with a emergency situation during radiography. Because head trauma patients is very important in patient care, especilly in CT at night, charged doctor should be always sitted with CT room and monitoring patient. Radiography was reqested by many diagnostic department in ER. Considering that rate of simple radiography is high, special room for emergency radiopraphy should be established in ER area, and the radioprapher of this room should be stationed radiologic technician who is career and can implement emergency patient care and The disposition of men which is appropriate with emergency patient increase is necessary.

The Evaluation of Space Dose Distribution for Digital Mammography Equipment (디지털 유방촬영장비에 관한 공간선량율 평가)

  • Jung, Hongmoon;Jung, Jaeeun;Hyun, Hyejin;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • Mammography equipment is an essential detector for making an early diagnosis of female's breast lesion. Recently, in most hospitals, a digital mammography detector is used due to the wide and consistent supply of digital mammography equipment. However, the average effective radiation is increasing due to the indiscreet use of CR or DR mammography. The purpose of this study is to recognize the possible indirect radiation damage, which can be occurred due to an excessive effective exposure of radiation, by evaluating spacial radiation rate of the digital mammography detector used for female patient. Consequently, the high mount of spacial radiation showed digital mammography equipment on the horizontal direction. Considering the result, digital mammography equipment should be installed by avoiding along the horizontal direction.

A Study for Virtual Reality 360 Video Production Workflow with HDR Using log Shooting (log 촬영과 HDR을 이용한 실사 360 영상 제작흐름 연구)

  • Kim, Chulhyun
    • Journal of Broadcast Engineering
    • /
    • v.23 no.1
    • /
    • pp.63-73
    • /
    • 2018
  • These days, VR contents are created in three ways: CG based method, game engine based method, and live action shooting method. The most universal method is live action shooting. So far, most live actions are shot with action cams. Therefore, this method is different from professional image production method for movies and TV dramas. This study tries to point out the difference between professional image production method and action cam based shooting method, and proposes an alternative. The proposed method is log shooting based HDR filming and editing. As the result of test shooting and editing, the proposed method was able to obtain more color information than conventional action cam based shooting method and thereby to implement high-definition images which are hard in an action cam.

GEOMETRIC CORRECTION OF RADIOGRAPHIC IMAGES USING GENERAL PURPOSE IMAGE PROCESSING PROGRAM (일반 영상처리 프로그램을 이용한 방사선사진의 기하학적 보정에 관한 연구)

  • Cheong Ji-Seong;Kim Eun-Kyung;Lee Sang-Hoon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.371-379
    • /
    • 1994
  • 본 연구는 비규격화시켜 촬영한 두장의 방사선 사진을 일반 영상처리 프로그램으로 기하학적 보정을 하여 디지탈 공제 촬영술을 시행한 결과를 개인별로 제작된 필름유지장치를 이용하여 규격화 시켜 촬영한 두장의 방사선사진을 디지탈 공제 촬영술을 시행한 결과와 비교하여 일반 영상처리 프로그램의 임상적 유용성을 평가해보고자 시행하였다. 19명의 자원자를 대상으로 하여, 각 환자에서 4매의 하악구치부 치근단 사진을 촬영하였다. 그중 2매는 XCP 필름 유지장치만으로 평행촬영법으로 촬영하였고, 나머지 2매는 교합제에 인상재를 부가하여 개인별로 제작된 XCP필름 유지장치를 이용하여 표준화시켜 역시 평행촬영법으로 촬영하였다. 기하학적 보정은 "Adobe Photoshop"과 "NIH Image" 프로그램으로 시행하였다. 특히 "Adobe Photoshop"의 임의영상회전 기능과 "IH Image"의 공제시술시 중첩된 사진을 투명하게 보여주는 기능, 병진기능을 활용하였다. 두 사진의 유사성을 측정하기 위해 공제된 사진의 계조도의 표준편차를 구하였다. 표준화군의 평균 표준편차가 기하학적 보정군의 평균 표준편차보다 약간 낮았으나, 통계적으로 유의성이 있는 차이를 보이지는 않았다. 위의 결과로 미루어보아, 하악구치부 에서 XCP필름 유지장치로 평행촬영한 비표준화방사선사진을 "Adobe Photoshop"과 "NIH Image" 프로그램을 이용하여 기하학적 보정을 할 수 있으리라 사료된다.

  • PDF

Implementation of a Filming Drone with Target Tracking Function (목표물 추적 기능을 갖춘 촬영용 드론의 구현)

  • Choi, Duk-Kyu;Kim, Ui-Jun;Lee, Jonghyeon;Kim, Seunguk;Kim, Changmin;Lee, Changmin;Paik, Gidong;Kim, Sanghyeon;Kim, Junhyeong;Myoung, Sanggi
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.01a
    • /
    • pp.173-174
    • /
    • 2021
  • 드론은 군사, 촬영, 배송, 인명구조, 조사, 단속 분야 등 산업 전반적인 영역에 활용되고 있다. 그중 촬영용 드론은 영상제작에 있어서 다양한 구도를 제공함으로써 영상제작과 구도의 다양성에 도움을 주어서 방송국에서 촬영을 위해 활용을 한다. 하지만 1인 제작자는 누군가의 도움 없이 드론 조종을 하면서 촬영하는 것은 어려움이 많고 현재 1인 제작 영상이나 사진을 찍기 위해서는 머리에 캠을 부착하거나 손에 삼각대나 지지대를 들고 다녀야하는 번거로움이 있다. 유도 촬영드론을 이용해 촬영 범위가 보다 넓어질 수 있고 장시간 손에 들고 있지 않아도 된다는 장점이 있다. 영상 촬영의 방법과 구도를 증가시킬 수 있고 1인 영상제작자에게는 다른 이의 도움 없이 홀로 자유롭고 편하게 드론 촬영을 할 수 있다.

  • PDF

Developing an HDR Imaging Method for an Ultra-thin Light-Field Camera (초박형 라이트필드 카메라를 위한 HDR 이미징 알고리즘 개발)

  • Jiwoong Na;Jaekwan Ryu;Yongjin Jo;Min H. Kim
    • Journal of the Korea Computer Graphics Society
    • /
    • v.29 no.3
    • /
    • pp.13-19
    • /
    • 2023
  • 카메라 센서의 한계로 인하여 촬영 장면에 따라 한 번의 촬영으로 모든 영역의 밝기가 적절하게 촬영되지 않는 경우가 존재한다. 이러한 센서의 한계는 하이 다이나믹 레인지 이미징 기술을 통해서 극복이 가능하다. 한 장면을 다양한 노출 설정으로 여러 번 촬영하는 브라케팅은 움직이는 피사체를 찍기에 적절하지 않으며 촬영 시간이 길다는 단점이 있다. 본 연구는 한 번의 촬영으로 서로 다른 노출의 이미지를 얻을 수 있는 소형 라이트필드 카메라를 제안한다. 라이트필드 카메라는 대표적으로 두 가지 형태가 있는데, 첫 번째는 여러 대의 카메라를 어레이로 배치한 라이트필드 카메라 시스템이며, 두 번째는 대물렌즈 뒤에 마이크로 렌즈 어레이를 배치한 카메라이다. 본 연구에서 제작된 초박형 라이트필드 카메라는 센서 위에 마이크로 렌즈어레이가 부착되어있는 형태의 카메라로 각 렌즈 조리개 크기를 다르게 설계하여 한 번의 촬영으로 다른 노출의 촬영 결과를 얻을 수 있게 설계되었다. 촬영된 단일 영상들을 전처리 하여 이미지 품질을 높인 이후, HDR 알고리즘을 통해 각 단일 이미지들보다 다이나믹 레인지가 넓은 이미지를 획득하도록 구현하였다. 또한 노출 시간을 기준으로 설계된 식을 수정하여 조리개값에 따라 다른 가중치를 둘 수 있도록 바꾸었고, 이를 통해 단 한 번의 촬영을 통한 HDR 이미징을 구현하였다.

The efficacy of computerized tomographic scan for chest trauma (흉부외상 환자에 대한 전산화 단층촬영의 효용성)

  • Roh, Hwan-Kyu;Choi, Ho;Kim, Young-Jin;Kim, Jung-Tae;Soh, Dong-Moon;Ryu, Han-Young;Lee, Cheol-Joo
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.298-303
    • /
    • 1998
  • Computerized tomography(CT) is an effective technique in the initial evaluation of the abdomen and head following blunt trauma. To evaluate the efficacy of CT of the thorax, a retrospective study comparing early thoracic CT scanning with initial chest roentgenogram (CXR) was carried out on 134 patients with blunt trauma on the chest. Among 134 patients, 45 patients had normal initial chest roentgenogram and 24 patients showed normal CT findings. Sensitivities of diagnosing pneumothorax and pleural effusion by CXR were low (46.2 and 62.9% respectively), whereas 71.4%(45/63) of patients had thoracostomy only by CXR. Although sometimes abused, CT of the thorax is effective in the initial diagnosis.

  • PDF

Research on the Actual Condition of Mammograpgy and Space Scattered Dose in Mammography Room (유방촬영의 실태와 유방촬영실의 공간산란선량에 관한 조사 연구)

  • Lee, In-Ja;Park, Kye-Yeon;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • I made inquires about mammographic equipments and circumstances of mammography rooms in the 64 medical facilities in areas of Seoul and Kyong Gi Do. Moreover I had experments about exposure dose with patients and radiologic technologists. so there is the data indicated follows. 1. There are inclined to improve in quality and function of mammographic equipments, it has been proven that s/f system exchanged to DR system. 2. It is certain that the number of examinations are becoming increasingly significant. 3. The Space Scattered Dose of mammography rooms are much more larger than portable equipments. 4. I worry about the affection of expose dose about Space Scattered Dose of mammography room. 5. There is need of study how to cope with the situation about increasing exposure dose of radiologic technologists in small space and numeruous number of examinations.

  • PDF

EFFECTIVE DOSE FROM CONE BEAM CT FOR IMAGING OF MESIODENS (상악 정중과잉치 진단을 위한 cone beam CT의 유효선량)

  • Han, Won-Jeong;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.273-279
    • /
    • 2012
  • Purpose : This study was aimed to calculate effective dose from cone beam CT and compare effective dose from periapical and panoramic radiography for mesiodens. Materials and Methods : Upper anteiror periapical, panoramic radiography and cone-beam CT were taken for diagnosis of mesiodens. The effective dose were calculated by using an anthropomorphic phantom loaded with thermoluminescent dosimeters at the 23 sites related to sensitive organs. Results : The highest absorbed doses were received by the mandibular body, parotid gland and cheek from periapical, panoramic and cone-beam CT, respectively. The effective doses for periapical, panoramic radiography and cone-beam CT measured 2, 18 and 48 ${\mu}Sv$. Conclusion : Cone-beam CT, although providing additional diagnostic benefits, exposes patients to higher levels of radiation than conventional periapical and panoramic radiography.