• Title/Summary/Keyword: 촬영조건

Search Result 645, Processing Time 0.038 seconds

Determination of Appropriate Exposure Angles for the Reverse Water's View using a Head Phantom (두부 팬텀을 이용한 Reverse Water's View에 관한 적절한 촬영 각도 분석)

  • Lee, Min-Su;Lee, Keun-Ohk;Choi, Jae-Ho;Jung, Jae-Hong
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.187-195
    • /
    • 2017
  • Early diagnosis for upper facial trauma is difficult by using the standard Water's view (S-Water's) in general radiograph due to overlapping of anatomical structures, the uncertainty of patient positioning, and specific patients with obese, pediatric, old, or high-risk. The purpose of this study was to analyze appropriate exposure angles through a comparison of two different protocols (S-Water's vs. reverse Water's view (R-Water's)) by using a head phantom. A head phantom and general radiograph with 75 kVp, 400 mA, 45 ms 18 mAs, and SID 100 cm. Images of R-Water's were obtained by different angles in the range of $0^{\circ}$ to $50^{\circ}$, which adjusted an angle at 1 degree interval in supine position. Survey elements were developed and three observers were evaluated with four elements including the maxillary sinus, zygomatic arch, petrous ridge, and image distortion. Statistical significant analysis were used the Krippendorff's alpha and Fleiss' kappa. The intra-class correlation (ICC) coefficient for three observers were high with maxillary, 0.957 (0.903, 0.995); zygomatic arch, 0.939 (0.866, 0.987); petrous ridge, 0.972 (0.897, 1.000); and image distortion, 0.949 (0.830, 1.000). The high-quality image (HI) and perfect agreement (PA) for acquired exposure angles were high in range of the maxillary sinus ($36^{\circ}-44^{\circ}C$), zygomatic arch ($33^{\circ}-40^{\circ}$), petrous ridge ($32^{\circ}-50^{\circ}$), and image distortion ($44^{\circ}-50^{\circ}$). Consequently, an appropriate exposure angles for the R-Water's view in the supine position for patients with facial trauma are in the from $36^{\circ}$ to $40^{\circ}$ in this phantom study. The results of this study will be helpful for the rapid diagnosis of facial fractures by simple radiography.

A Survey on Patient Dose and Exposure Conditions in Simple Radiography of the Abdomen (복부 단순 X-선 촬영조건과 환자 피폭에 관한 조사 연구)

  • Kim, Sung-Soo;Lee, Sun-Sook;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.59-65
    • /
    • 1996
  • We studied exposure techniques and exposure dose for simple abdomen A-P projection for 41 medical facilities that are located in Seoul area. 1. The range of tube voltage used was 60 to 84 kVp, the average tube voltage used was 74 kVp 2. Only 17% of added filter was used. 3. Tube current mostly used was 200 mA, some of them used 400 mA. 4. The grid ratio mostly was used 10 : 1, 54 % of the rare earth screen was used in most facilities. 5. The average skin entrance dose was 4.15 mSv and the dose range was 1.05 mSv to 11.0 mSv.

  • PDF

A Experimental Study on the Correction Methods of X-ray Exposure Factors (촬영조건의 교정에 관한 실험)

  • Huh, Joon;Kim, Chang-Kyun;Lee, Sun-Sook;Kim, Hak-Seong
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.67-70
    • /
    • 1984
  • Radiographic units have changeable factors in x-ray outputs, Therefore, an exposure factor by basic experimental study must be made out about each x-ray installation, but this is very intricate methods and not a practical business. Authors tried out a new method to make simple exposure factors. The first, we had a experimental object radiograph taken to find the output of each radiographic unit. The second, by obtained x-ray density we found the difference in x-ray output. and lastly, we made a new and simple correction method to use the obtained output and x-ray density.

  • PDF

CR장치와 일반 촬영 장치에서 피폭선량 측정과 촬영조건표 작성에 관한 연구

  • Kim, Heung-Tae;Gwon, Su-Il;Gwon, Dal-Gwan;Kim, Hwa-Gon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.3 no.1
    • /
    • pp.76-84
    • /
    • 1997
  • We tried to find any factor to reduce the exposure dose with ST-VA type generator which has the higher exposure dose. The guideline recommended by the provisions of IAEA regulation is being used at the time of radiation exposure and almost of those equipments used for this study had less amount of doses than those in the guideline. The FCR may be possible to decrease a certain amount of dose with effective applications of it's automatic image compensation utilities and the verifying function in PACS. Next time, it is required to add a great number of hospitals for wide range of studios and measurements, and make standard exposure Control table which will bing in practice, material decrease of dose volumes when radiation exposure.

  • PDF

A Study on High Kilovoltage Technique in taking Chest Radiogram. (흉부(胸部) 고관전압(高管電壓) 촬영조건(撮影條件)에 관(關)한 검토(檢討))

  • Kang, Hong-Seok;Kim, Chang-Kyun;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.37-43
    • /
    • 1979
  • High kilovoltage technique as compared with low kilovoltage in taking chest radiogram has much advantages. Authors performed an experiment by using acryl phantom to make the technical chart at 120KV and obtained the results as follows; 1. Increase and decrease of tube voltage in thickness change was 3.2KV per cm at variable technic chart. 2. At fixed kilovoltage technic chart, increase and decrease was $0.12{\sim}0.2$ mAs per cm in chest thickness. 3. Increase and decrease of distance was 1.3inches per cm in thicknese change

  • PDF

Comparison of SPOT5 Orthorectification Imagery Accuracy by DEM Scale (DEM축척에 따른 SPOT5영상의 정사보정 정확도 비교)

  • Lee Chong-Soo;Lee Sang-Ik;Lee Woo-Kyun;Jeon Seong-Woo;Kang Byung-Jin
    • Proceedings of the KSRS Conference
    • /
    • 2006.03a
    • /
    • pp.319-322
    • /
    • 2006
  • 2002년 5월 촬영이 시작된 SPOTS 영상은 공간해상도가 2.5mX2.5m로 고해상도이면서도 촬영폭이 광역적이어서 다양한 활용이 가능하다. SPOT5영상을 보다 유용하게 활용하기 위해서는 단순 기하보정 보다는 높은 정확도를 얻을 수 있는 정사보정이 요구된다. 보정영상의 정확도에 영향을 미치는 요소로는 지형, GCP, DEM등이 있다. 본 연구에서는 다른 조건들은 동일하게 하고, 자료 구축에 많은 시간이 소요되는 DEM(수치표고모델)의 축척만을 달리하여 보정 영상의 정확도를 비교하였다. 그 결과 DEM의 축척 변화가 보정 영상에 미치는 영향은 미비한 것으로 나타났다. 따라서 작업의 효율성을 고려할 경우에 소축척의 DEM을 사용하는 것이 바람직하다.

  • PDF

Heat Transfer Measurement in a Supersonic Flowfield by an Infra-red Thermography (적외선 측정 기법을 이용한 초음속 유동내 열전달 측정)

  • Yu, Man-Sun;Yi, Jong-Ju;Song, Ji-Woon;Cho, Hyung-Hee
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.359-362
    • /
    • 2006
  • Infra-red thermography was conducted to understand a heat transfer characteristic on a surface protruded to a supersonic flowfield. Surface temperature distribution was obtained under the constant heat flux condition with a infra-red camera and the convective heat transfer coefficient distribution was calculated. Finally, two dimensional distribution of heat transfer coefficient on a surface around a cylinder body was derived.

  • PDF

Kompsat EOC 및 Landsat TM 영상을 이용한 변화탐지 기법 연구

  • 이성순;지광훈;강준묵
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.04a
    • /
    • pp.265-269
    • /
    • 2003
  • 최근 인공위성 영상자료는 주기적인 획득 시기를 가지고 있고 수치 지형도에 비해 쉽게 인지할 수 있기 때문에 지형변화 모니터링 분야에서 활발하게 이용되고 있다 그러나 인공위성 영상자료들은 촬영조건 및 센서의 특성에 따라 다른 기하학적인 왜곡을 포함하고 있을 뿐만 아니라 공간, 방사 및 분광 해상도가 상이하기 때문에 정밀한 분석 결과 산출에 어려움이 있다. 즉, 두 개 이상의 영상을 비교 분석하기 위해 기본적인 센서 정보의 차이에서 발생하는 정오차를 소거하고 지형기복에 의해 발생하는 부정오차를 제거하기 위한 정밀 기하보정은 반드시 선행되어야 한다. 따라서, 본 연구에서는 공간해상도가 다르기 때문에 발생하는 정오차 및 부정오차를 제거하기 위해 정밀정합을 실시하였다. 정밀 정합된 kompsat EOC 및 Landsat TM 영상으로 토지피복 변화를 탐지함으로써 위치정확도가 높은 탐지결과를 얻을 수 있었다. 정확한 위치정보를 가지는 탐지 결과는 지형지물의 갱신이나 다양한 GIS 응용의 기본자료로서 사용할 수 있을 것으로 기대된다.

  • PDF

Blast Fragmentation Measurement Using the Image Based Granulometry System (영상처리기법에 의한 발파파쇄암의 파쇄도 측정)

  • 선우춘;류창하;최병희
    • Explosives and Blasting
    • /
    • v.19 no.2
    • /
    • pp.5-18
    • /
    • 2001
  • 채석, 광물채광 등의 발파에서 생성된 파쇄 암석편들에 대한 정확한 파쇄도의 측정은 발파효율성 및 경제성을 평가하기 위한 수단으로 사용될 수 있다. 발파현장에서 파쇄도의 측정은 파쇄암석의 크기를 대상으로 이루어지며, 이러한 측정의 궁극적인 목표는 파쇄도에 대한 정확한 측정과 분석을 통하여 발파를 최적화시킴으로써 과파쇄에 의한 화약의 낭비, 과대한 암괴로 인한 운반경비의 증가, 분할을 위한 2차 발파나 추가파쇄를 위한 경비증가 등을 줄일 수 있다. 또한 선광 및 파쇄장비들의 과대한 마모방지와 품질의 균질성 확보를 위한 모니터링의 수단으로 사용될 수도 있다. 최근 파쇄도측정에 많이 사용되고 있는 기술중의 하나가 영상처리 시스템으로, 본 논문에서는 촬영조건 및 분석대상물 등의 변화에 따른 이 영상처리기법의 문제에 대한 언급보다는 영상처리기법에 대한 이해를 돕기 위해 이 기법에 대한 설명과 상용 소프트웨어를 이용한 모델시험 및 채석현장에서 실시된 발파후의 파쇄암석들에 대한 파쇄도 분석에서의 문제점들에 대하여 언급하고자 한다.

  • PDF

A Method for Camera Calibration using Virtual Checkerboard Pattern (가상 체스보드 패턴 기반 카메라 캘리브레이션 방법)

  • Kim, Joonsoo;Yun, Kugjin;Jung, Jun Young;Cheong, Won-sik;Seo, Jeongil
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2019.06a
    • /
    • pp.236-237
    • /
    • 2019
  • 본 논문에서는 가상의 체스보드판을 이용한 카메라 캘리브레이션 방법을 제안한다. 제안된 방법에서는 카메라 포즈나 체스보드판의 움직임을 모사하기 위해 가상 카메라로 획득한 여러 포즈의 체스보드 이미지를 디스플레이에 표시하고 디스플레이를 캘리브레이션 대상이 되는 카메라로 촬영한다. 가상 체스보드 격자점좌표와 촬영된 이미지의 체스보드 격자점좌표 사이의 homography 행렬로부터 카메라 파라미터에 대한 제한조건을 추출할 수 있음을 보였고, 렌즈 왜곡을 고려한 전체 카메라 캘리브레이션 방법 또한 제안하였다.

  • PDF