• Title/Summary/Keyword: 촬영조건

Search Result 644, Processing Time 0.02 seconds

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

A Morphologic Study of head and face for Sasang Constitution (사상체질별(四象體質別) 두면부(頭面部)의 형태학적(形態學的) 특징(特徵))

  • Ko, Byung-Hee;Song, Il-Byung;Cho, Yong-Jin;Choi, Chang-Seok;Kim, Jong-Weon;Hong, Suck-CHull;Lee, Eui-Ju;Lee, Sang-Yong;Seo, Jeong-Sug
    • Journal of Sasang Constitutional Medicine
    • /
    • v.8 no.1
    • /
    • pp.101-186
    • /
    • 1996
  • The clinical application of constitutional Diagnosis is the most important part of Sasang constitutional medicine. It has been studied in various way. However, the study of morphologic characteristics on the face is applied for the first time. For quantitative analysis of the correlation between the sasang constitution and the shape of the face, the head-facial part of 170 cases were measured by Martin's measurement and analysis of a) the measurement value of height and the component ratio from the Gnathion to each part of face by constitution. b) the measurement value of depth and the component ratio from T-projected to each part of the face by constitution. c) the measurement value of breadth and component ratio between each parts of the facial breadth by constitution. d) the ratio of square on every part of face by constitution. e) the characteristics on each part of the face by constitution. f) the contour line of the forehead. g) the result of discriminant analysis about the constitution. Authors obtained the results from the study as follows; 1. The characteristics of Taeum-IN (1) The measurement value of Height, Breadth, T-Projected had a tendency to maximum value in general. (2) The value of lower opthal height and the square of lower opthal part was maximum. (3) The value of Pronasal T-projected length and Subnasal T-projected length was minimum, so Taeum-In has characteristics of depression in middle face, nasal part. (4) In the ratio of Breadth, T-Projected, T-Projected was minimum. (5) It was maximum that the square of nose, Alare, Middle face, Lower face and it was minimum that the square of eye. The square of nose, Alare, Middle facc, Lower face was maximum and the square of eye was minimum. (6) The curvature of the eyebrow was minimum. (7) The projection of jaw (Pogonion T-projection length) was maximum. (8) The breadth of eye was minimum. (9) There was a tendency that the projection of the forehead to the right in general. 2. The characteristics of Soeum-In (1) In all cases of projected length the measurement value was minimum. (2) The value of lower opthal height and the square of lower opthal part was minimum. (3) By the Pupulare T-projected length, the value of Pronasal T-projected length and Subnasal T-projected length was minimum, so the Soeum In's face shape is flat. (4) The square of eye, mouth, forehead was maximum and the square of nose, Alare, Middle face, Lower face was minimum. (5) The curvature of the eyebrow was maximum. (6) The projection of mouth was minimum. (7) The jaw was flat. (8) The breadth of eye was maximum. (9) There was a tendency that the projection of the forehead to the left in general. 3. The characteristics of Soyang-In. (1) In most cases of 고경 length the measurement value was minimum. (2) By the Pupulare T-projected length, each ratio of projected length was maximum, so the Soyang-In's face shape has many protrusions (3) In the ratio of Breadth, T-Projected, T-Projected was maximum. (4) The square of mouth was minimum. (5) The inclination of the forehead was minimum. (6) The projection of mouth was maximum. (7) The breadth of eye was minimum. (8) There was a tendency that the projection of the forehead to the left in general. (9) The middle face was protruded. 4. Discriminant about the constitution. According to the result of discriminant, the accuracy probability of discriminant was 85.58% in total and Taeum-In was 90.5%, Soeum-In was 70.8%, Soyang-In was 89.5%. The accuracy probability of discriminant about 3 constitutional group increased by 49.03% than the accident probility 36.55% 5. Suggestion (1) The study which gather and analysis the data should be continued. (2) The study which subdivide the characteristics of each part of the face by the constitution should be continued. (3) The analysis method about Moire should be supplement. (4) The study about the morphologic characteristics of the whole body should be continued. (5) Computer program of constitution diagnosis should be developed. (6) To increase utility of this method, the measurement should be automation.

  • PDF

Evaluating efficiency of application the skin flash for left breast IMRT. (왼쪽 유방암 세기변조방사선 치료시 Skin Flash 적용에 대한 유용성 평가)

  • Lim, Kyoung Dal;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.49-63
    • /
    • 2018
  • Purpose : The purpose of this study is investigating the changes of treatment plan and comparing skin dose with or without the skin flash. To investigate optimal applications of the skin flash, the changes of skin dose of each plans by various thicknesses of skin flash were measured and analyzed also. Methods and Material : Anthropomorphic phantom was scanned by CT for this study. The 2 fields hybrid IMRT and the 6 fields static IMRT were generated from the Eclipse (ver. 13.7.16, Varian, USA) RTP system. Additional plans were generated from each IMRT plans by changing skin flash thickness to 0.5 cm, 1.0 cm, 1.5 cm, 2.0 cm and 2.5 cm. MU and maximum doses were measured also. The treatment equipment was 6MV of VitalBeam (Varian Medical System, USA). Measuring device was a metal oxide semiconductor field-effect transistor(MOSFET). Measuring points of skin doses are upper (1), middle (2) and lower (3) positions from center of the left breast of the phantom. Other points of skin doses, artificially moved to medial and lateral sides by 0.5 cm, were also measured. Results : The reference value of 2F-hIMRT was 206.7 cGy at 1, 186.7 cGy at 2, and 222 cGy at 3, and reference values of 6F-sIMRT were measured at 192 cGy at 1, 213 cGy at 2, and 215 cGy at 3. In comparison with these reference values, the first measurement point in 2F-hIMRT was 261.3 cGy with a skin flash 2.0 cm and 2.5 cm, and the highest dose difference was 26.1 %diff. and 5.6 %diff, respectively. The third measurement point was 245.3 cGy and 10.5 %diff at the skin flash 2.5 cm. In the 6F-sIMRT, the highest dose difference was observed at 216.3 cGy and 12.7 %diff. when applying the skin flash 2.0 cm for the first measurement point and the dose difference was the largest at the application point of 2.0 cm, not the skin flash 2.5 cm for each measurement point. In cases of medial 0.5 cm shift points of 2F-hIMRT and 6F-sIMRT without skin flash, the measured value was -75.2 %diff. and -70.1 %diff. at 2F, At -14.8, -12.5, and -21.0 %diff. at the 1st, 2nd and 3rd measurement points, respectively. Generally, both treatment plans showed an increase in total MU, maximum dose and %diff as skin flash thickness increased, except for some results. The difference of skin dose using 0.5 cm thickness of skin flash was lowest lesser than 20 % in every conditions. Conclusion : Minimizing the thickness of skin flash by 0.5 cm is considered most ideal because it makes it possible to keep down MUs and lowering maximum doses. In addition, It was found that MUs, maximum doses and differences of skin doses did not increase infinitely as skin flash thickness increase by. If the error margin caused by PTV or other factors is lesser than 1.0 cm, It is considered that there will be many advantages in with the skin flash technique comparing without it.

  • PDF

Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors (악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료)

  • Kwon, Da Eun;Hwang, Ji Hye;Park, In Seo;Yang, Jun Cheol;Kim, Su Jin;You, Ah Young;Won, Young Jinn;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Helmet type bolus for 3D printer is being manufactured because of the disadvantages of Bolus materials when photon beam is used for the treatment of scalp malignancy. However, PLA, which is a used material, has a higher density than a tissue equivalent material and inconveniences occur when the patient wears PLA. In this study, we try to treat malignant scalp tumors by using M3 wax helmet with 3D printer. Methods and materials: For the modeling of the helmet type M3 wax, the head phantom was photographed by CT, which was acquired with a DICOM file. The part for helmet on the scalp was made with Helmet contour. The M3 Wax helmet was made by dissolving paraffin wax, mixing magnesium oxide and calcium carbonate, solidifying it in a PLA 3D helmet, and then eliminated PLA 3D Helmet of the surface. The treatment plan was based on Intensity-Modulated Radiation Therapy (IMRT) of 10 Portals, and the therapeutic dose was 200 cGy, using Analytical Anisotropic Algorithm (AAA) of Eclipse. Then, the dose was verified by using EBT3 film and Mosfet (Metal Oxide Semiconductor Field Effect Transistor: USA), and the IMRT plan was measured 3 times in 3 parts by reproducing the phantom of the head human model under the same condition with the CT simulation room. Results: The Hounsfield unit (HU) of the bolus measured by CT was $52{\pm}37.1$. The dose of TPS was 186.6 cGy, 193.2 cGy and 190.6 cGy at the M3 Wax bolus measurement points of A, B and C, and the dose measured three times at Mostet was $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$ and $195.33{\pm}1.69cGy$. And the error rates were -3.71 %, -4.59 %, and 2.48 %. The dose measured with EBT3 film was $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$ and $196{\pm}2.16cGy$. The error rates were -2.46 %, 0.23 % and 2.83 %. Conclusions: The thickness of the M3 wax bolus was 2 cm, which could help the treatment plan to be established by easily lowering the dose of the brain part. The maximum error rate of the scalp surface dose was measured within 5 % and generally within 3 %, even in the A, B, C measurements of dosimeters of EBT3 film and Mosfet in the treatment dose verification. The making period of M3 wax bolus is shorter, cheaper than that of 3D printer, can be reused and is very useful for the treatment of scalp malignancies as human tissue equivalent material. Therefore, we think that the use of casting type M3 wax bolus, which will complement the making period and cost of high capacity Bolus and Compensator in 3D printer, will increase later.