• Title/Summary/Keyword: 촬영장치

Search Result 700, Processing Time 0.027 seconds

An Experimental Study on Blade Deformation of Coaxial Rotor System Using SPR(Stereo Pattern Recognition) Technique (SPR(Stereo Pattern Recognition) 기법을 이용한 동축 로터 블레이드의 변형에 대한 실험적 연구)

  • Yoo, Chanho;Yoon, Byung-Il;Chae, Sanghyun;Kim, Do-Hyung;Kim, Deog-Kwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.8
    • /
    • pp.597-609
    • /
    • 2020
  • These days, the coaxial rotor system is used for various purposes like UAVs, Mars exploration helicopters, and the next-generation high-speed rotorcraft. A number of research projects on aerodynamic performance of rotor systems, including the coaxial configuration have been made previously. On the contrary, research on rotor blade deformation has been mainly carried out regarding the single rotor system, where such effort has not been enough on the coaxial system. Nonetheless, in case of the coaxial system, blade deformation analysis is much more important because of the complex air flow around the rotors, and that the distance between the two rotors is a key factor affects aerodynamic performance of the entire system. For these reasons, an experimental study on rotor blade deformation of the coaxial system was conducted using the Stereo Pattern Recognition(SPR) technique, one of the state-of-the-art of photogrammetry method. In this research, a small-scale coaxial rotor test stand designed by Korea Aerospace Research Institute(KARI) was used. With the same test stand, performance of the coaxial configuration had been studied before the experimental study on blade deformation, in order to find the relation between performance and blade deformation of the rotor system. Results of the performance test and the deformation study are presented in this article.

Changes of Regional Homogeneity and Amplitude of Low Frequency Fluctuation on Resting-State Induced by Acupuncture (침자극에 의한 안정성 네트워크 변화를 관찰하기 위한 Regional Homogeneity와 Amplitude of Low Frequency Fluctuation의 변화 비교: fMRI연구)

  • Yeo, Sujung
    • Korean Journal of Acupuncture
    • /
    • v.30 no.3
    • /
    • pp.161-170
    • /
    • 2013
  • Objectives : Our study aimed to investigate the sustained effects of sham (SHAM) and verum acupuncture (ACUP) into the post-stimulus resting state. Methods : In contrast to previous studies, in order to define the changes in resting state induced by acupuncture, changes were evaluated with a multi-method approach by using regional homogeneity (ReHo) and amplitude of low frequency fluctuation (ALFF). Twelve healthy participants received SHAM and ACUP stimulation right GB34 (Yanglingquan) and the neural changes between post- and pre-stimulation were detected. Results : The following results were found; in both ReHo and ALFF, the significant foci of; left and right middle frontal gyrus, left medial frontal gyrus, left superior frontal gyrus, and right posterior cingulate cortex, areas that are known as a default mode network, showed increased connectivity. In addition, in ReHo, but not in ALFF, brain activation changes in the insula, anterior cingulate cortex, and the thalamus, which are associated with acupuncture pain modulation, were found. Conclusions : In this study, results obtained by using ReHo and ALFF, showed that acupuncture can modulate the post-stimulus resting state and that ReHo, but not ALFF, can also detect the neural changes that were induced by the acupuncture stimulations. Although more future studies with ReHo and ALFF will be needed before any firm conclusions can be drawn, our study shows that particularly ReHo could be an interesting method for future clinical neuroimaging studies on acupuncture.

Breast cancer screening rates-related factors Korea women ever considering area environmental characteristics: The fourth Korea National Health and Nutrition Examination Survey(KNHANES IV) (지역 환경적 요인이 한국 여성의 유방암 조기검진 수검률에 미치는 영향 : 국민건강영양조사 제 4기를 중심으로)

  • Lee, Mi-Hwa;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.437-449
    • /
    • 2014
  • In this study, we analyzed an effect of area-environmental factor on breast cancer screening rates using multi-level analysis. It was intended for the KNHANES-IV. Total subjects were 14338. Among them, 4143 subjects met the inclusion criteria. When we applied only empty Model, a variance of breast cancer screening rates was 0.061 in each region. When we applied Model with individual level variables, the variance was 0.034. However, when we applied both Model with individual level variables and Model with area level variables, the variance was 0.023. We drew applied only individual level variables parallel applied 3 regional variances which could explain variance of inspection of breast cancer up to 18.04% compared with applied only individual level variables. Area level variables could reduce a variance of region. This means besides individual level variables. The group can share a same thing and can effect to breast cancer screening rates. We need to discover factors which area level variables and suggest that make a standard for inspection of breast cancer.

A Study of Conservative Treatment for Patients with Osteoarthritis of the TMJ (측두하악골관절염 환자의 보존적 치료에 관한 연구)

  • Son, Dae-Eun;Ok, Seung-Joon;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.227-239
    • /
    • 2007
  • To evaluate the treatment outcome after conservative treatment in patients with osteoarthritis of the TMJ(OA), the subjects were chosen among the patients who presented to the Department of Oral Medicine of Pusan National University Hospital, diagnosed as osteoarthritis of the TMJ, and treated with conservative methods from 1994 to 2006. 101 patients with diagnosis of osteoarthritis of the TMJ were selected as the experimental group and 74 patients with diagnosis of masticatory muscle disorders(MMD) were selected as the control group. Subjective symptoms and clinical findings were investigated to evaluate and compare the subject's status at the first and the last visit. The results were as follows : 1. In the OA group, satisfactory treatment outcome was obtained with conservative methods. But, at the last visit, the symptoms of the OA group were not improved enough compared with those of the MMD group. 2. In the OA group, radiographic findings of panorama view and transcranial projection were positive by about 60 percent. But, computed tomography and single photon emission computed tomography were positive by more than 90 percent. 3. At the last visit of the OA group, the joint noise was reduced significantly. 4. In the majority of the OA group, satisfactory treatment outcome was obtained with conservative methods such as medication, physical therapy, and occlusal stabilization appliance. In the majority of the MMD group, satisfactory outcome was obtained with medication and physical therapy. 5. It took the OA group from 6 months to 2 years to be cured well while the MMD group within 6 months.6. The OA group needed more than 10 times' treatment for satisfactory outcome while the MMD group needed less than 10 times' treatment.

Effects of Facemask Therapy for Class III Malocclusions in Patients with Different Vertical Skeletal Patterns (3급 부정교합 환자의 수직적 골격 양상에 따른 facemask 치료 효과 비교)

  • Lee, Eunha;Park, Kitae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.2
    • /
    • pp.126-135
    • /
    • 2015
  • The purpose of this study was to evaluate the skeletal and dentoalveolar effects of facemask therapy and to compare the anchorage of a bonded expander in patients with Class III malocclusion and different vertical skeletal patterns. Twenty subjects with Class III malocclusion were included in this study and were treated with a facemask and bonded expander. Based on the FMA, subjects were divided into two groups of 10 patients each: a high vertical group (HV; mean FMA $33.56^{\circ}$) and an average vertical group (AV; mean FMA $24.88^{\circ}$). Lateral cephalograms were taken and evaluated before and after treatment. In both groups, forward movement of the maxilla and backward rotation of the mandible were observed after treatment, with no statistical differences between the groups. Vertical skeletal variables increased in both groups, but the increase of FMA was significantly larger in the HV group than the AV group. Mesial movement of maxillary molars and proclination of maxillary incisors which indicate anchorage loss of bonded expander were observed in both groups, with no significant differences between the groups. In conclusion, facemask therapy resulted in effective maxillary protraction in both HV and AV groups. However, the open bite tendency was increased more in the HV group.

A Convergence Study on Evaluation of Usefulness of Copper Additional Filter in the Digital Radiography System (디지털 방사선장치에서 구리 부가필터의 유용성 평가에 관한 융복합 연구)

  • Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.351-359
    • /
    • 2015
  • This convergence study analyzed the effectiveness of digital radiography system of copper(Cu) filter in the added filtration for the removal of lower energy radiation through dose and image evaluation. We were analyzed from April to June 2015 result of the examination. Cu filter was applied to each non, 0.1, 0.2, 0.3 mm according to change of kV and mAs and doses were evaluated. Image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by seven items for resolution and contrast from chest x-ray criteria of national cancer checkup. The absorbed doses with Cu were lowered by 16-88 % than non-filter but the gaps decreased as kV increased. PSNR were over 30 dB and all significant and CNR and SNR were superior with non-filter but in the qualitative analysis, there were different statistical significant according to each item. The score of 0.1 mm filter was high at pulmonary blood vessel observation and in the 0.3 mm Cu, there were no statistical signigicant except high density and full of air portion. Cu filter can improve image quality with lower radiation dose using better radiation quality and correction power at digital radiography system.

A Qualitative Analysis on Paraspinal Muscles in Patients with Acute Low Back Pain and Chronic Low Back Pain (급성 요통환자와 만성 요통환자에서 척추주변근육의 정량적 분석)

  • Jeong, Dae-Keun
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.613-620
    • /
    • 2013
  • This study was conducted to measure and analyze the changes in paraspinal muscles of acute and chronic low back pain patients using MRI, and to provide clinical basic data for diagnosis and treatment for low back pain. For this purpose, 20 patients with acute low back pain frome August 2012 to January 2013 which occurred within 12 weeks, and 20 patients with chronic low back pain that progressed over 12 weeks, were chosen as subjects, and their MRI measurements were compared with one another. As a result, in relation to in the fatty degeneration ratio of the left spine and right spine, there were significant differences in erector spinae and multifidus(p<.001), and in relation to the Fat Infiltration ratio between all the groups, there were significant differences in psoas major, erector spinae and multifidus between the acute low back pain patient group and the chronic low back pain patient group(p<.001). In the post-hoc test, multifidus and erector spinae in the acute low back pain group and chronic low back pain group showed the highest Fat Infiltration ratio. The serious Fat Infiltration of multifidus and erector spinae in the chronic low back pain group led to weakened strength of muscles that stabilize the spine. In conclusion, it is considered that this study would present important data and basis in making acute and chronic low back pain patients pay more attention to multifidus and psoas major during rehabilitation exercise, and selecting a rehabilitation exercise program.

An Image Management System of Frame Unit on a Hand-held Device Environments (휴대장치 환경을 위한 프레임 단위의 영상 데이터 관리 시스템)

  • Choi, Jun-Hyeog;Yoon, Kyung-Bae;Han, Seung-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.7
    • /
    • pp.29-36
    • /
    • 2008
  • This paper proposes algorithm for the system that can search for an image of a frame unit, and we implement it. A system already inserts in images after generating the cord that mechanical decoding and identification are possible. We are independent of an external noise in a frame unit, and a system to propose at these papers can search for an image recorded by search condition to include recording date, recording time, a recording place or filming course etc. This system is composed by image insertion wealth to insert data to an image to data image code generation wealth, a frame generating data image code you apply a code generation rule to be fixed in order to express to a price to have continued like data entry wealth, GPS locator values and direction price receiving an image signal, image decoding signals and an image search signal to include search condition, and to have continuity from users each of an image. Also, image decoding we decipher about the noise that was already added from the outsides in a telerecording process, a copy process or storage processes inserted in images by real time, and searching image information by search condition. Consequently we implement decoder, and provide the early system that you use, and we easily insert data code among images. and we can search. and maximization can get precision regarding an image search and use satisfaction as we use algorithm to propose at these papers.

  • PDF

A Study on Projection Image Restoration by Adaptive Filtering (적응적 필터링에 의한 투사영상 복원에 관한 연구)

  • 김정희;김광익
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.119-128
    • /
    • 1998
  • This paper describes a filtering algorithm which employs apriori information of SPECT lesion detectability potential for the filtering of degraded projection images prior to the backprojection reconstruction. In this algorithm, we determined m minimum detectable lesion sized(MDLSs) by assuming m object contrasts uniformly-chosen in the range of 0.0-1.0, based on a signal/noise model which provides the capability potential of SPECT in terms of physical factors. A best estimate of given projection image is attempted as a weighted combination of the subimages from m optimal filters whose design is focused on maximizing the local S/N ratios for the MDLS-lesions. These subimages show relatively larger resolution recovery effect and relatively smaller noise reduction effect with the decreased MDLS, and the weighting on each subimage was controlled by the difference between the subimage and the maximum-resolution-recovered projection image. The proposed filtering algoritym was tested on SPECT image reconstruction problems, and produced good results. Especially, this algorithm showed the adaptive effect that approximately averages the filter outputs in homogeneous areas and sensitively depends on each filter strength on contrast preserving/enhancing in textured lesion areas of the reconstructed image.

  • PDF

Physical Vapor Deposition공정 시, Substrate 온도에 따른 X-선 검출용 비정질 셀레늄의 성능평가

  • Kim, Dae-Guk;Gang, Jin-Ho;Kim, Jin-Seon;No, Seong-Jin;Jo, Gyu-Seok;Sin, Jeong-Uk;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.210.2-210.2
    • /
    • 2013
  • 현재 국내의 상용화된 디지털 방식 X-선 영상장치에서 간접변환방식은 대부분 CsI를 사용하고 있으며, X-선 흡수에 의해 전기적 신호를 발생시키는 직접변환방식은 Amorphous Selenium(a-Se)을 사용한다. a-Se은 진공 중에 녹는점이 낮아 증착시 substrate의 온도에 따라 민감한 변화를 보인다. 본 연구에서는 간접변환방식에 비해 높은 영상의 질을 획득할 수 있는 직접변환방식의 a-Se기반 X-선 검출기 제작 시 substrate에 인가된 온도에 따른 특성을 연구하여 최적화 된 substrate의 온도를 알고자 한다. 본 실험에서는 glass에 투명한 전극물질인 Indium Tin Oxide (ITO)가 electrode로 형성된 substrate를 사용하였으며 그 상단에 a-Se을 Physical Vapor Deposition (PVD)방식을 거쳐 X-선 검출기 샘플을 제작하였다. PVD 공정 시 네 개의 보트에 a-Se 시료를 각각 100g씩 총 400g을 넣고, $5{\times}10-5Torr$까지 진공도를 낮추었다. 보트의 온도는 $270^{\circ}C$에서 40분 $290^{\circ}C$에서 90분으로 온도를 인가하여 a-Se을 기화시켜 증착하였다. 증착 시 substrate 온도를 각각 $20^{\circ}C$, $40^{\circ}C$, $60^{\circ}C$, $70^{\circ}C$ 네 종류로 나누어 실험을 진행하였다. 끝으로 증착된 a-Se 상단에 Au를 PVD방식으로 electrode를 형성시켜 a-Se기반의 X-선 검출기 샘플 제작을 완료하였다. 제작된 a-Se기반의 X-선 검출기 샘플의 두께는 80에서 $85{\mu}m$로 온도에 따른 차이가 없었다. 이후에 전기적 특성을 평가하기위해 electrometer와 oscilloscope를 이용하여 Dark current와 Sensitivity를 측정하여 Signal to Noise Ratio(SNR)로 도출하였으며 Scanning Electron Microscope(SEM) 표면 uniformity를 관찰하였다. 또한 제작된 a-Se기반 X-선 검출기 샘플의 hole collection 성능을 확인하고자 mobility를 측정하였다. 측정결과 a-Se의 work function을 고려한 $10V/{\mu}m$기준에서 70kV, 100mA, 0.03sec의 조건의 X-선을 조사 하였을 때 Sensitivity는 세 종류의 검출기 샘플이 15nC/mR-cm2에서 18nC/mR-cm2으로 비슷한 양상을 나타내었지만, substrate온도가 $70^{\circ}C$때의 샘플은 10nC/mR-cm2이하로 저감됨을 알 수 있었다. 그리고 substrate온도 $60^{\circ}C$에서 제작된 검출기 샘플의 전기적 특성이 SNR로 환산 시, 15.812로 가장 우수한 전기적 특성을 나타내어 최적화 된 온도임을 알 수 있었다. SEM촬영 시 온도상승에 따라 표면 uniformity가 우수하였으며, Mobility lifetime에서는 $60^{\circ}C$에서 제작된 검출기 샘플이 deep trap 수치가 높아 hole이 $0.04584cm2/V{\cdot}sec$$0.00174cm2/V{\cdot}sec$의 electron보다 26.34배가량 빠른 것을 확인하였다. 본 연구를 통해 a-Se증착 시, substrate에 인가된 온도는 균일한 박막의 형성 및 표면구조에 영향을 미치며 온도가 증가할수록 안정적인 전기적 특성을 나타내지만 $70^{\circ}C$이상일 시, a-Se층의 결정화가 생겨 deep trap을 발생시켜 전기적 특성이 저하됨을 확인 할 수 있었다. 따라서 증착 시의 substrate의 온도 최적화는 a-Se기반 X-선 검출기의 안전성 및 성능향상을 위해 불가피한 요소가 된다고 사료된다.

  • PDF