• Title/Summary/Keyword: 촬영장치

Search Result 700, Processing Time 0.027 seconds

A Realistic Modeling and Rendering of Cloth Textures by Photometry (사진 측정에 의한 옷감의 질감 모델링 및 사실적 렌더링)

  • Kim, Min-Soo;Kim, Dae-Hyun;Kim, Myoung-Jun
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.2
    • /
    • pp.84-93
    • /
    • 2008
  • Modeling and rendering of cloth texture have been regarded as one of the most important factors to enhance reality of the contents in the digital contents industry. So far, however, two major approaches to realistically describe the cloth texture were developed: building analytical reflectance model for target cloth and sometimes thread itself and obtaining overall reflectance model using optical equipments. However, yielding a plausible analytic reflection model satisfying many subtle characteristics of a cloth is not an easy task; moreover, fine-detailed modeling of the cloth pattern across the target clothes should also be accompanied by huge amount of computation. The method to obtain overall reflectance model needs expensive measurement equipments and data size becomes huge. Since it applies in the end the reflectance model obtained at one point of a cloth to across whole the visible area of the target clothes, it cannot properly reproduce the pattern of the clothes nor the texture. To address the aforementioned problems, this paper proposes a simple low cost camera rig and a novel method for realistic modeling and rendering of the cloth texture by analyzing photos taken by the proposed camera rig, which can reproduce even the texture pattern applied to the whole clothes, overcoming the one-point reflectance model.

Trend of Technology in Video Surveillance System

  • Song, Jaemin;Park, Arum;Lee, Sae Bom
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.57-64
    • /
    • 2020
  • Video surveillance is consists of cameras, transmission devices, storage and playback devices, and is used for crime prevention and disaster monitoring. Recently, it has been spreading to a wide variety of fields, and has developed into an intelligent video surveillance system that can automatically recognize or track characteristic objects of people and things. The purpose of this study was to investigate the cases of video surveillance service applying the latest technology by dividing it into the home, public, and private sectors. also this study tried to investigate and research what advantage it brings from a business perspective. By looking at the cases introduced in this study, it was confirmed that the viedo security service is developing intelligently, such as excellent compatibility with CCTV, multiple video surveillance, CCTV screen motion detection, and alarm through automatic analysis.

A Study on the Building Height Estimation and Accuracy Using Unmanned Aerial Vehicles (무인비행장치기반 건축물 높이 산출 및 정확도에 관한 연구)

  • Lee, Seung-weon;Kim, Min-Seok;Seo, Dong-Min;Baek, Seung-Chan;Hong, Won-Hwa
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.2
    • /
    • pp.79-86
    • /
    • 2020
  • In order to accommodate the increase in urban population due to government-led national planning and economic growth, many buildings such as houses and business building were supplied. Although the building law was revised and managed to manage the supplied buildings, for the sake of economic benefit, there have been buildings that are enlarged or reconstructed without declaring building permits. In order to manage these buildings, on-site surveys were conducted. but it has many personnel consumption. To solve this problem, a method of using a satellite image and a manned aircraft is utilized, but it is diseconomical and a renewal cycle is long. In addition, it is not utilized to the height, and although it is judged by the shading of the building, it has limitations that it must be calculated individually. In this study, height of the building was calculated by using the unmanned aerial vehicle with low personnel consumption, and the accuracy was verified by comparison with the building register and measured value. In this study, spatial information was constructed using a fast unmanned aerial vehicle with low manpower consumption and the building height was calculated based on this. The accuracy by comparing the calculated building height with the building register and the actual measurement.

Cephalometric difference according to the differential treatment methods in Class III malocclusion; (제 III급 부정교합 환자들의 각 치료법에 따른 측모두부방사선사진 계측치의 비교)

  • Baik, Hyoung Seon
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.197-208
    • /
    • 1997
  • Class III malocclusion patients can be approached with many different types of treatment methods, and thus, each patient's problems must be accurately evaluated to allow selection of the best possible treatment method. Cephalometric analysis is an essential part of diagnosis and treatment planning of orthodontic patients, and it would certainly be helpful if reliable cephalometric guidelines could be set. The author divided 482 Class III malocclusion patients(253 males and 229 females) into fourgroups according to different types of treatment methods they have received to correct imbalance between upper and lower jaws: 1) orthopedic appliance (face mask & RPE), 2) camouflage treatment with fixed appliance, 3) surgical-orthodontic treatment, 4) cross-bite correction with removable plates/ functional appliance. Cephalometric values at the time of first clinical examination were compare among the four groups. Cephalometric analysis indicates the following results: 1)the amounts of antero-posterior and vertical skeletal discrepancies and dental compensation were greatest in surgery group 2) SNB, Wits, distance from Nasion Perpendicular Plane to point a facial angle, facial convexity, and APDI were greater in orthopedic appliance group than fixed appliance(camouflage) group, but there was no statistical difference 3) removable plates/ functional appliance group showed least amounts of skeletal discrepancies and dental compensation with statistical significance.

  • PDF

Driver's Status Recognition Using Multiple Wearable Sensors (다중 웨어러블 센서를 활용한 운전자 상태 인식)

  • Shin, Euiseob;Kim, Myong-Guk;Lee, Changook;Kang, Hang-Bong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.6
    • /
    • pp.271-280
    • /
    • 2017
  • In this paper, we propose a new safety system composed of wearable devices, driver's seat belt, and integrating controllers. The wearable device and driver's seat belt capture driver's biological information, while the integrating controller analyzes captured signal to alarm the driver or directly control the car appropriately according to the status of the driver. Previous studies regarding driver's safety from driver's seat, steering wheel, or facial camera to capture driver's physiological signal and facial information had difficulties in gathering accurate and continuous signals because the sensors required the upright posture of the driver. Utilizing wearable sensors, however, our proposed system can obtain continuous and highly accurate signals compared to the previous researches. Our advanced wearable apparatus features a sensor that measures the heart rate, skin conductivity, and skin temperature and applies filters to eliminate the noise generated by the automobile. Moreover, the acceleration sensor and the gyro sensor in our wearable device enable the reduction of the measurement errors. Based on the collected bio-signals, the criteria for identifying the driver's condition were presented. The accredited certification body has verified that the devices has the accuracy of the level of medical care. The laboratory test and the real automobile test demonstrate that our proposed system is good for the measurement of the driver's condition.

THE EFFECT AND RELAPSE PATTERN OF FACEMASK THERAPY FOR CLASS III MALOCCLUSION CHILDREN (유치열기 3급 부정교합 환아에서 facemask의 효과와 재발 양상)

  • Kim, Ji-Yeon;Yoo, Seung-Eun;Lee, Ji-Hyun;Ki-Tae, Ki-Tae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.420-426
    • /
    • 2009
  • The purpose of this study was to evaluate skeletal and soft tissue changes that occur after using a facemask for treatment of skeletal class III malocclusion, and to assess the relapse pattern when no retention appliance was used. Fifteen skeletal class III malocclusion patients were treated with a facemask for an average of 12 months. No retention appliance was used during the 1 year follow-up period. Cephalograms were taken during pretreatment, posttreatment, and the 1 year follow-up. Cephalograms were traced, analyzed, and the results were compared between cephalograms. All patients showed significant sagittal skeletal changes after treatment, but they also showed a significant relapse during the 1 year follow-up period when no retention appliance was used. Despite the relapse, the sagittal skeletal changes that remained were still significant. Vertical skeletal change was also significant after treatment, but the total change was not significant after a 1 year follow-up due to relapse. In soft tissue changes, facial convexity and upper lip position improved after treatment and this change remained significant after the 1 year follow-up period. Facemask therapy is therefore an effective method for treatment of skeletal class III malocclusion, however, retention is imperative to maintain the treatment effect.

  • PDF

The Effects of the CT Voltages on the Dose Calculated by a Commercial RTP System (CT 관전압이 상용 전산화치료계획장치의 선량계산에 미치는 영향)

  • 강세권;조병철;박희철;배훈식
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.23-29
    • /
    • 2004
  • The relationship between the dose calculated with a radiotherapy treatment planning system (RTPS) and CT number verses the relative electron density curve was investigated for various CT voltages and beam qualifies. We obtained the relationship between the CT numbers and electron densities of the tissue equivalent materials for various CT voltages and beam qualifies. At lower CT voltages, the higher density materials, like cortical bone, showed larger CT numbers and the soft tissues showed no variations. We peformed a phantom study in a RTPS, where a phantom consisted of lung and bone legions in water. We calculated the dose received behind the lung and bone regions for 6 MV photon beams, in which the regions below the lung, water and bone received higher doses in this listed order. The result was the same for 10 MV photon beams. For the clinical application, the doses were calculated for the lung and pelvis. No difference was observed when using different electron density conversion tables with various CT voltages from a same CT. A relative dose difference of 1.5% was obtained when the CT machine for the density conversion table was different from that for the CT image for planning.

  • PDF

Development and optimization of C-11 gas target system in KOTRON-13 cyclotron (KOTRON-13 사이클로트론의 고효율C-11 가스 표적장치)

  • Lee, Hong-Jin;Lee, Won-Kyeong;Park, Jun-Hyung;Moon, Byung-Seok;Lee, In-Won;Chae, Sung-Ki;Lee, Byung-Chul;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.86-89
    • /
    • 2011
  • Purpose: The KOTRON-13 cyclotron was developed in South Korea and was introduced to regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce carbon-11 isotope so far. We herein study how to develop and optimize an effective carbon-11 target system in the KOTRON-13 cyclotron by changing cooling system, combing with fluorine-18 target and evaluating beam currents. Materials and Method: To develop the optimal carbon-11 target and an effective cooling system, we designed the carbon-11 target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we evaluated the yield of carbon-11 production at different beam currents and the stability of the operation of the KOTRON-13 cyclotron. Results: The production of carbon-11 was enhanced from about 1.700 mCi ($50{\mu}A$) to 2,000 mCi ($60{\mu}A$) on the carbon-11 target which developed by seoul national university bundang hospital (SNUBH) and Samyoung Unitech. Additionally, the cooling condition was showed stable to produce carbon-11 under high beam current. Conclude: The carbon-11 target system of the KOTRON-13 cyclotron was successfully developed and improved carbon-11 production. Consequently, the operation of carbon-11 target system was highly effective and stable compare with other commercial cyclotrons. Our results are believed that this optimal carbon-11 target system will be helpful for the routine carbon-11 production in the KOTRON-13 cyclotron.

  • PDF

Automatic Walking Guide for Visually Impaired People Utilizing an Object Recognition Technology (객체 인식 기술을 활용한 시각장애인 자동 보행 안내)

  • Chang, Jae-Young;Lee, Gyu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.115-121
    • /
    • 2022
  • As city environments have recently become crowded, there are many obstacles that interfere with the walking of the visually impaired on pedestrian roads. Typical examples include ballads, parking breakers and standing signs, which usually do not get in the way, but blind people may be injured by collisions. To solve such a problem, many solutions have been proposed, but they are limited in applied in practical environments due to the several restrictions such as outside use only, inaccurate obstacle sensing and requirement of special devices. In this paper, we propose a new method to automatically detect obstacles while walking on the pedestrian roads and warn the collision risk in advance by using only sensors embedded in typical mobile phones. The proposed method supports the walking of the visually impaired by notifying the type of obstacles appearing in front of them as well as the distance remaining from the obstacles. To accomplish this goal, we utilized an object recognition technology applying the latest deep learning algorithms in order to identify the obstacles appeared in real-time videos. In addition, we also calculate the distance to the obstacles using the number of steps and the pedestrian's stride. Compared to the existing walking support technologies for the visually impaired, our proposed method ensures efficient and safe walking with only simple devices regardless of the places.

Comparison of Average Glandular Dose in Screen-Film and Digital Mammography Using Breast Tissue-Equivalent Phantom (유방조직등가 팬텀을 이용한 Screen-Film과 Digital Mammography에서의 평균 유선선량)

  • Shin, Gwi-Soon;Kim, Jung-Min;Kim, You-Hyun;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.13-23
    • /
    • 2007
  • In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate(IP). We measured average glandular doses(AGD) in screen-film mammography(SFM) system with slow screen-film combination, computed mammography(CM) system, indirect digital mammography(IDM) system and direct digital mammography(DDM) system using brest tissue-equivalent phantom(glandularity 30%, 50% and 70%). The results were shown as follows : AGD values for DDM system were highest than those for other systems. Although automatic exposure control(AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter(Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in oder to estimate a patient radiation dose.

  • PDF