• Title/Summary/Keyword: 촬영장치

Search Result 700, Processing Time 0.027 seconds

A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment (진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구)

  • Heo, Yeji;Kim, Kyotae;Noh, Sicheul;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.105-110
    • /
    • 2014
  • Diagnostic radiation equipment diagnosis and treatment of disease of recent plays a central role, but this is based on the assumption of an appropriate balance of benefits and risks of diagnostic. If balance is not maintained has the potential to give an adverse effect on the health of the public. In the case of an overseas, the importance of (QA) quality assurance of medical equipment is growing, but evaluation criteria of quality assurance has not been clearly presented in domestic. Therefore, the modernization of medical equipment from the point at which the degree of cycle-by-cycle management system of foreign national to be suitable for diagnostic radiation generator entry and quality control standards by introducing a tailoring is necessary. In this study the most frequently used diagnostic radiation generator X-ray imaging apparatus of the general three-year periodic inspections at any time between the periodic inspection items and quality control methods and standards for the establishment of the United States, Canada and abroad, and international electronic literature search Technical Committee (International Electro-technical Commission, IEC) were compared with the provisions of item. Based on the national quality control items when opening frequent inspection items and standards presented as a basis for setting up study.

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

The Recent Trend of the National and International Standard of Manufacturing Quality Control for Diagnostic X-ray Equipment (진단용엑스선장치 제조품질관리에 관한 국내.외 규격의 동향)

  • Choi, In-Seok;Kim, Jung-Min;Jeong, Hoi-Woun;Min, Jung-Whan;Lee, In-Su
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.1-15
    • /
    • 2009
  • Newly published IEC 60601-1-3 ; 2008 2nd Edition has two important meanings. First, Radiation Quality and Dose should make sure for safety of patient and staff in manufacturing diagnostic X-ray equipment. Second, it should be minimized of Leakage Radiation, Residual Radiation, and Stray Radiation. The requirement to make enactment or revision of national standard for diagnostic X-ray Equipment is as follows : 1. It should be adjusted the new standard to the recent IEC Publication under the consideration of the Korea medical circumstances. 2. For focus to the Radiation Safety, IEC 60601-1-3 (General requirements for radiation protection in diagnostic X-ray equipment) could be applied to the new regulation. It should be compact sentence. 3. A sudden Notification change should not be desired. It needs a enough time to make easy the circumstances.

  • PDF

Survey of CT Practice and Collective Effective Dose Estimation (CT검사건수 및 CT검사에 의한 집단 실효선량의 추정)

  • Lee, Man-Koo;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.231-237
    • /
    • 2010
  • Computed tomography (CT) has been established as an important diagnostic tool in clinical medicine and has become a major source of medical exposure. A nationwide survey regarding CT examinations was carried out in 2007. Thanks to the appeasement policy regulating the import of CT scanners, there are 1,825 CT scanners across the country as of the end of March 2010, which means that we have 36.8 CT scanners per one million people. The annual number of examinations was 3.29 million, the number of examinations per 1000 population was 68. The most part of examinations was abdomen and pelvis. and the collective effective dose was in these parts. The effective dose per one population was evaluated as 0.952 mSv.

Implementation of NTSC TV Transmitter Module (NTSC TV Transmitter Module의 구현)

  • Kim Kwang-Tae;Sim Myoung-Su
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.2 s.308
    • /
    • pp.28-32
    • /
    • 2006
  • In this paper, NTSC TV Transmitter Modulo will be designed and produced which make possible playing the motion picture not only on TV but also on portable TV. NTSC TV Transmitter Module modulates signals that received Video and Audio signals from a mobile on NTSC TV CH4 mechanism. so it has an advantage of convenience that watching the motion picture of mobile on TV without any other cable through transmitting signals by wireless. But it has some demerits of long size antenna and noise sensitiveness. In the future, if some problems like a size of antenna distortion of signal and noise can be solved through continuous researching about Radio Frequency part, it is possible to play mobile motion pictures on the more media like a camcorder, DVD player and so on.

A Study on Legal Problems over Unmanned Vehicle of the Fourth Industrial Revolution - Focusing on the Autonomous Driving Vehicle and Drone - (제4차 산업혁명 시대의 무인 이동체를 둘러싼 법적 문제점 연구 - 자율주행자동차와 드론을 중심으로 -)

  • Kye, Kyoung-Moon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.7
    • /
    • pp.519-527
    • /
    • 2017
  • The trust issue on the safety of autonomous vehicle is a very important in regard to the demand generation of relevant industries. To secure the trust, The study of legal liability issue should be prior to an accident of the autonomous vehicle. In civil law, it is possible to make the automobile manufacturer take legal responsibility with the "Product Liability Act". Whereas, in criminal law, it is difficult to make him take legal responsibility since the criminal law holds the actor responsible. To solve these problems, this article proposes the establishment of the "Special Act on Autonomous Vehicle". Also, there is a demand for building infra structures and system to operate the (fully) self-propelled vehicle and establishing "certification" systems.

Finite Element Analysis of Wrist Orthosis with 3D Printing (3D 프린트를 통해 제작된 손목 보조기의 유한요소해석)

  • Choi, Hyeun-Woo;Kang, Inyeong;Noh, Gunwoo;Seo, Anna;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.947-953
    • /
    • 2019
  • The purpose of this study was to manufacture a wrist brace using a computerized tomography system, clinical design software (MediACE 3D Program), and 3D printer. After acquiring the Dicom file of the upper limb with a computed tomography, the wrist brace was designed using the MediACE 3D Program to create a "stereolithography" file. The designed wrist brace was printed using a 3D printer. To verify the effectiveness of wrist assistive device manufactured by 3D printing technology, the stress distribution of the pressure and orthosis applied to bone and skin is represented by finite element analysis. It is expected that the wrist brace can be manufactured by reinforcing the part where the damage caused by pressure and breakage of the brace frequently occurs with the result of finite element analysis when producing the wrist brace.

Development and Estimation of Low Price-Small-Autopilot UAS for Geo-spatial Information Aquisition (지형정보획득용 저가 소형 자동항법 UAS개발 및 평가)

  • Han, Seung Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.1343-1351
    • /
    • 2014
  • Recent technological advances in wireless networks and microelectromechanical systems (MEMS) have led to the development of different types of mini-UAVs and their utilizations in various ways. This study endeavors to develop a low-cost mini-UAV with autonomous flight capability, in order to obtain geospatial information of a small or medium-sized area, and also assess its flight stability by comparing the predetermined flight paths against the actual flight paths. Based on a post-development flight test, stable flight has been proven achievable as follows: the maximum endurance speed is 1 hour, the flying distance is 50km, the horizontal accuracy of flight paths is about ${\pm}6{\sim}8m$, and the altitude accuracy is about ${\pm}8m$. Therefore, it is deemed that high-resolution images which can be utilized for geospatial information are obtainable. This indicates that a UAV flying at an altitude of 200m can acquire images across a $2km{\times}3km$ area on the ground within 25 minutes, which validates its high usability for obtaining high-solution images at low altitudes in the future.

Convergence system of offshore wind infrastructure monitoring using the RC submarine (RC잠수함을 이용한 해상풍력하부구조 모니터링 융합시스템)

  • Bang, Gul-Won;Bang, Sang-Won;Kim, Yong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.6
    • /
    • pp.177-183
    • /
    • 2015
  • The image information acquired by a model submarine is transmitted through the repeater. The control signal of a position for submarine and its speed is also controlled by the repeater. Shooting images of underwater circumstances are transmitted to the repeater where the received signal controls a position and speed of underwater submarine. This repeater is combined by a buoy that is floating on the surface to relay the signal of image as well as control between a control unit and a submarine whereas the repeater communicates wirelessly with a control unit. Due to wire communication between the repeater and the submarine, the underwater exploration can be smoothly carried out without a risk of loss of a model submarine. Also, connecting to the repeater and control unit wirelessly makes it possible to conduct easily the underwater exploration. The convergence technology that combines a wireless communication and a control as well as a model submarine is designed.

Implementation of Digital Light Drawing System based on Stereo Vision (스테레오 비전 기반 Light Drawing 시스템 구현)

  • Park, Won-Bae;Park, Chang-Bum;Paik, Doo-Won
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.130-137
    • /
    • 2010
  • Light Drawing is a photographic technique which exposures are made at night or in a darkened room usually by moving a hand-held light source[1]. Due to the limitations of equipment and environment, users having difficulty in drawing a picture in 3D space. If user take a light drawing, they need a camera that have function and darkened environment. Alternative solution is that we can make a light drawing picture by using the computer drawing tool as in Photoshop. Nevertheless, this solution will let the User lose their interest in drawing because this solution cannot synchronize between the real action of human hand motion and the electronic input devices such as mouse and keyboard. This paper proposed a digital content that can make light drawing easier. We used a digital content that will facility Light Drawing easier. We can measure the light spot position by using the stereo camera. Based on the measured position of the light spot, we reproduce light drawing in virtual space by using drawing effect method.