• 제목/요약/키워드: 촬영장치

Search Result 700, Processing Time 0.036 seconds

Evaluation of Radiolucent Considering the Compression Paddle Materials in Mammography (유방촬영장치의 압박대 재질을 고려한 투과선량 평가)

  • Hong, Dong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.307-312
    • /
    • 2015
  • Mammography improves image quality that is on the increase day by day and get a picture with the pressure it is essential to reduce the dose. However, because due to the thickness of the cuff itself may increase the dose scattering lines is necessary study on the cuff material. Material that is currently being used in clinical Polycarbonate is a plastic and family. If you try to reduce the exposure of patients than itgie need to consider for the better material in this study to compare against a radiolucent line for amorphous plastic material of the plastic. results radiolucent and half layer, transmitting dose Pixel values HIPS, GPPS, ABS, Tritan, PC, PMMA showed high results in the net.

Visualization of Roll Torque Generating Flows in a SRM Submerged-Nozzle by Cold Air-flow Test (내삽노즐 고체로켓모터의 공기 유동모사시험을 통한 롤토크 발생유동 가시화)

  • Kim, Do-Hun;Lee, In-Chul;Lee, Yeol;Koo, Ja-Ye;Kang, Moon-Jung;Kim, Yoon-Gon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.2
    • /
    • pp.29-35
    • /
    • 2011
  • The behaviors of combustion-induced internal flows of SRM equipped with fin-slot grain and submerged nozzle are very complex and diverse. Cold air-flow tests for 2D and 3D scale models of SRM have been done in order to specify the visualization method to analyze particular internal flow patterns such as roll-torque inducing flow. Swirl flow induced by asymmetric vortical tubes also has been visualized through employing various light source and recording directions.

Developing integrated black-box system for proving sudden unintended acceleration of vehicles utilizing OBD-II and a camera attached to a foot (자동차 급발진 사고 시 원인 규명을 위하여 OBD-II 와 차량 내 풋 카메라를 이용한 통합 블랙박스 시스템 개발)

  • Lee, Jung-eun;Jang, Jong-wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.438-441
    • /
    • 2013
  • 알려진바 한 해 우리나라에서 200여 건 이상의 차량 급발진으로 추청 되는 사고(Sudden Unintended Acceleration, SUA)가 발생하지만 지금까지 명확하게 급발진으로 추정되는 사고의 원인을 밝혀내지 못해 사고를 당한 운전자는 막대한 정신적, 물질적 피해를 보고 있다. 이에 차량의 급발진으로 추정되는 사고 시 차량의 상태 및 원인 파악을 위하여 차량 내 설치되는 OBD-II(On Board Diagnostics-II)와 운전자의 발쪽을 촬영하는 Foot Camera를 이용하여 통합 블랙박스 시스템을 구현하고자 한다. 지금까지의 블랙박스 시스템은 단순히 사고 시 영상을 촬영 저장하여 운전자에게 보여 주는 장치라면 현재 구현하려는 통합시스템은 블랙박스 자체에서 이동 통신을 통한 차량데이터 실시간 서버 전송 및 스마트 폰과 스마트 패드의 앱(App)으로 OBD-II와 메인서버와의 통신을 통해 사용자 차량의 현재 상태, 차량의 이상 유무, 소모품 교환 시기, 차량사고 시 영상 및 급발진 추정 시 차량상태, 위치, 이동거리, 운전자의 발쪽 영상 저장 및 재생 등 사용자가 필요로 하는 다양한 기능과 정보들을 블랙박스 하나로 통합하여 구현 할 것이다. 이 시스템이 개발되면 차량 관리에 서툰 여성 운전자들, 좀 더 체계적이고 손쉽게 내 차 정보를 원하는 운전자들과 전 세계 자동차 소비자들의 관심사인 급발진에 대한 사고 분석이 정확해 질 것으로 여겨진다.

  • PDF

Improve utilization of Drone for Private Security (Drone의 민간 시큐리티 활용성 제고)

  • Gong, Bae Wan
    • Convergence Security Journal
    • /
    • v.16 no.3_2
    • /
    • pp.25-32
    • /
    • 2016
  • Drone refers to an unmanned flying system according to the remote control. That is a remote control systems on the ground or a system that automatically or semi auto-piloted system without pilot on board. Drones have been used and developed before for military purposes. However there are currently utilized in a variety of areas such as logistics and distribution of relief supplies disaster areas, wireless Internet connection, TV, video shooting and disaster observation, tracking criminals etc. Especially it can be actively used in activities such as search or the structure of the disaster site, and may be able to detect the movement of people and an attacker using an infrared camera at night. Drones are very effective for private security.

Case Reports on the Improvement in the Balanced Position of the 2nd Cervical Vertebra and the Cervical Alignment after Functional Cerebrospinal Therapy (FCST) of TMJ Balancing Medicine (TBM) (개구촬영 방사선 영상을 통한 FCST의 치료 전후 축추 및 경추 위치변화 증례연구)

  • Lee, Young Jun;Yoo, Choon Shik;Lee, Sang Bae;Yin, Chang Shik
    • Journal of TMJ Balancing Medicine
    • /
    • v.5 no.1
    • /
    • pp.20-26
    • /
    • 2015
  • Four cases of functional cerebrospinal therapy (FCST) were reviewed to see whether any improvement is observed in the X-ray images of open-mouth view and cephalocervical views. Intraoral appliances of TMJ balancing appliance (TBA) and cervical balancing appliance (CBA) and active movement of within range-of-movement of the jaw and the neck were applied to each patient. Improved balance of $2^{nd}$ cervical vertebra position and cervical alignment were observed in all the four cases.

  • PDF

Visualization for Internal Flow of Submerged-Nozzle SRM by Cold Air-flow Test (내삽노즐 고체로켓의 공기 유동모사시험을 통한 내부유동 가시화)

  • Kim, Do-Hun;Cho, Yong-Ho;Lee, Yeol;Koo, Ja-Ye;Kim, Yoon-Gon;Kang, Moon-Jung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.181-185
    • /
    • 2010
  • The behavior of combustion-induced internal flow of SRM equipped with fin-slot grain and submerged nozzle is very complex and diverse. Cold air-flow test for 2D and 3D scale models of SRM has been done in order to specify the visualization method to analyze particular internal flow patterns such as roll-torque inducing flow. Swirl flow induced by asymmetric vortical tube also has been visualized through employing various light source and recording directions.

  • PDF

A Study on Location Tracking Streetlight (위치추적 가로등에 관한 연구)

  • Kim, Bum-Su;Kim, Seung-Goo;Song, Hyeong-Ho;Kim, Bo-Ryeon;Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1275-1280
    • /
    • 2018
  • We made a smartphone interlocking location tracking streetlight and remote display device to compensate the defect of real time identifiable CCTV streetlights and child safety notification applications. It controls brightness of LED by detecting the surrounding brightness and objects with ultrasonic sensor and illuminance senor. The CCTV receives the location of smartphone by Bluetooth and takes the target of the location. It realizes a wireless transmission system that the video is upload to the tablet PC via WiFi.

A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication (단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교)

  • Goo, EunHoe
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.1003-1011
    • /
    • 2020
  • This study aims to compare and evaluate the image differences between single and dual sources in applying a technique to reduce metal artifacts using dual energy CT. Discovery CT 256 (GE, USA) as a single source device and Somatom Definition Flash (Siemens Health Care, Forchheim, Germany) as a dual source device. The self-made phantom (pigs with medical titanium screws inserted) was quantitative and qualitatively evaluated under the same conditions by varying the dose under the same conditions using a dual energy CT. The evaluation method was compared by measuring SNR for metal artifacts (scattering, stripe) generated by metal inserts, divided around bones and around tissues. There was a difference in images in the method of reducing metal artifacts between single-source and dual-source devices. In a single source device, the linearized prosthesis by metal implantation showed a greater decrease than the image obtained from a double source device, and the surrounding tissue was well observed without interference from the artifact. In dual-source devices, scattering and stripe artifacts caused by metal inserts decreased more than on a single source device, and signals from adjacent tissues surrounding the metal implant were well observed without diminishing. If the examination is conducted separately between single source and dual source devices depending on whether the area to which the patient is intended to be viewed during the examination is adjacent to the metal insert or the total tissue surrounding the metal insert, it is believed that diagnostic helpful images can be obtained.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Development of Graphical Solution for Computer-Assisted Fault Diagnosis: Preliminary Study (컴퓨터 원용 결함진단을 위한 그래픽 솔루션 개발에 관한 연구)

  • Yoon, Han-Bean;Yun, Seung-Man;Han, Jong-Chul;Cho, Min-Kook;Lim, Chang-Hwy;Heo, Sung-Kyn;Shon, Cheol-Soon;Kim, Seong-Sik;Lee, Seok-Hee;Lee, Suk;Kim, Ho-Koung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.36-42
    • /
    • 2009
  • We have developed software for converting the volumetric voxel data obtained from X-ray computed tomography(CT) into computer-aided design(CAD) data. The developed software can used for non-destructive testing and evaluation, reverse engineering, and rapid prototyping, etc. The main algorithms employed in the software are image reconstruction, volume rendering, segmentation, and mesh data generation. The feasibility of the developed software is demonstrated with the CT data of human maxilla and mandible bones.