• Title/Summary/Keyword: 총에너지

Search Result 1,762, Processing Time 0.036 seconds

Evaluation of surface dose comparison by treatment equipment (치료 장비 별 표면 선량 비교평가)

  • Choi Eun Ha;Yoon Bo Reum;Park Byoung Suk;An Ye Chan;Park Myoung Hwan;Park Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.31-42
    • /
    • 2022
  • Purpose: This study measures and compares the surface dose values in the virtual target volume using Tomotherapy, Halcyon, and TrueBeam equipment using 6MV-Flattening Filter-Free(FFF) energy. Materials and Methods: CT scan was performed under three conditions of without bolus, 0.5 cm bolus, and 1 cm bolus using an IMRT phantom (IBA, Germany). The Planning Target Volume (PTV) was set at the virtual target depth, and the treatment plan was established at 200 cGy at a time. For surface dosimetry, the Gafchromic EBT3 film was placed in the same section as the treatment planning system and repeated measurements were performed 10 times and then analyzed. Result: As a result of measuring the surface dose for each equipment, without, 0.5 cm, 1 cm bolus is in this order, and the result of Tomotherapy is 115.2±2.0 cGy, 194.4±3.3 cGy, 200.7±2.9 cGy, The result in Halcyon was 104.7±3.0 cGy, 180.1±10.8 cGy, 187.0±10.1 cGy, and the result in TrueBeam was 92.4±3.2 cGy, 148.6±5.7 cGy, 155.8±6.1 cGy, In all three conditions, the same as the treatment planning system, Tomotherapy, Halcyon, TreuBeam was measured highly in that order. Conclusion: Higher surface doses were measured in Tomotherapy and Halcyon compared to TrueBeam equipment. If the characteristics of each equipment are considered according to the treatment site and treatment purpose, it is expected that the treatment efficiency of the patient will increase as well as the treatment satisfaction of the patient.

A prediction model for adolescents' skipping breakfast using the CART algorithm for decision trees: 7th (2016-2018) Korea National Health and Nutrition Examination Survey (의사결정나무 CART 알고리즘을 이용한 청소년 아침결식 예측 모형: 제7기 (2016-2018년) 국민건강영양조사 자료분석)

  • Sun A Choi;Sung Suk Chung;Jeong Ok Rho
    • Journal of Nutrition and Health
    • /
    • v.56 no.3
    • /
    • pp.300-314
    • /
    • 2023
  • Purpose: This study sought to predict the reasons for skipping breakfast by adolescents aged 13-18 years using the 7th Korea National Health and Nutrition Examination Survey (KNHANES). Methods: The participants included 1,024 adolescents. The data were analyzed using a complex-sample t-test, the Rao Scott χ2-test, and the classification and regression tree (CART) algorithm for decision tree analysis with SPSS v. 27.0. The participants were divided into two groups, one regularly eating breakfast and the other skipping it. Results: A total of 579 and 445 study participants were found to be breakfast consumers and breakfast skippers respectively. Breakfast consumers were significantly younger than those who skipped breakfast. In addition, breakfast consumers had a significantly higher frequency of eating dinner, had been taught about nutrition, and had a lower frequency of eating out. The breakfast skippers did so to lose weight. Children who skipped breakfast consumed less energy, carbohydrates, proteins, fats, fiber, cholesterol, vitamin C, vitamin A, calcium, vitamin B1, vitamin B2, phosphorus, sodium, iron, potassium, and niacin than those who consumed breakfast. The best predictor of skipping breakfast was identifying adolescents who sought to control their weight by not eating meals. Other participants who had low and middle-low household incomes, ate dinner 3-4 times a week, were more than 14.5 years old, and ate out once a day showed a higher frequency of skipping breakfast. Conclusion: Based on these results, nutrition education targeted at losing weight correctly and emphasizing the importance of breakfast, especially for adolescents, is required. Moreover, nutrition educators should consider designing and implementing specific action plans to encourage adolescents to improve their breakfast-eating practices by also eating dinner regularly and reducing eating out.

Comparison of Carbon Storage Based on Alternative Action by Land Use Planning (토지이용에 따른 대안별 탄소 저장량 비교)

  • Seulki Koo;Youngsoo Lee;Sangdon Lee
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.6
    • /
    • pp.377-388
    • /
    • 2023
  • Carbon management is emerging as an important factor for global warming control, and land use change is considered one of the causes. To quantify the changes in carbon stocks due to development, this study attempted to calculate carbon storage by borrowing the formula of the InVEST Carbon Storage and Sequestration Model (InVEST Model). Before analyzing carbon stocks, a carbon pool was compiled based on previous studies in Korea. Then, we estimated the change in carbon stocks according to the development of Osong National Industrial Park (ONIP) and the application of alternatives. The analysis shows that 16,789.5 MgC will be emitted under Alternative 1 and 16,305.3 MgC under Alternative 2. These emissions account for 44.4% and 43.1% of the pre-project carbon stock, respectively, and shows that choosing Alternative 2 is advantageous for reducing carbon emissions. The difference is likely due to the difference in grassland area between Alternatives 1 and 2. Even if Alternative 2 is selected, efforts are needed to increase the carbon storage effect by managing the appropriate level of green cover in the grassland, creating multi-layered vegetation, and installing low-energy facilities. In addition, it is suggested to conserve wetlands that can be lost during the stream improvement process or to create artificial wetlands to increase carbon storage. The assessment of carbon storage using carbon pools by land cover can improve the objectivity of comparison and evaluation analysis results for land use plans in Environmental Impact Assessment and Strategic Environmental Impact Assessment. In addition, the carbon pool generated in this study is expected to be used as a basis for improving the accuracy of such analyses.

A Study on Predicting the Logistics Demand of Inland Ports on the Yangtze River (장강 내수로 항만의 물류 수요 예측에 관한 연구)

  • Zhen Wu;Hyun-Chung Kim
    • Korea Trade Review
    • /
    • v.48 no.3
    • /
    • pp.217-242
    • /
    • 2023
  • This study aims to analyze the factors influencing the logistics demand of inland ports along the Yangtze River and predict future port logistics demand based on these factors. The logistics demand prediction using system dynamics techniques was conducted for a total of six ports, including Chongqing and Yibin ports in the upper reaches, Jingzhou and Wuhan ports in the middle reaches, and Nanjing and Suzhou ports in the lower reaches of the Yangtze River. The logistics demand for all ports showed an increasing trend in the mid-term prediction until 2026. The logistics demand of Chongqing port was mainly influenced by the scale of the hinterland economy, while Yibin port appeared to heavily rely on the level of port automation. In the case of the upper and middle reach ports, logistics demand increased as the energy consumption of the hinterland increased and the air pollution situation worsened. The logistics demand of the middle reach ports was greatly influenced by the hinterland infrastructure, while the lower reach ports were sensitive to changes in the urban construction area. According to the sensitivity analysis, the logistics demand of ports relying on large cities was relatively stable against the increase and decrease of influential factors, while ports with smaller hinterland city scales reacted sensitively to changes in influential factors. Therefore, a strategy should be established to strengthen policy support for Chongqing port as the core port of the upper Yangtze River and have surrounding ports play a supporting role for Chongqing port. The upper reach ports need to play a supporting role for Chongqing port and consider measures to enhance connections with middle and lower reach ports and promote the port industry. The development strategy for inland ports along the Yangtze River suggests the establishment of direct routes and expansion of the transportation network for South Korean ports and stakeholders. It can suggest expanding the hinterland network and building an efficient transportation system linked with the logistics hub. Through cooperation, logistics efficiency can be enhanced in both regions, which will contribute to strengthening the international position and competitiveness of each port.

Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF

Multi-classification of Osteoporosis Grading Stages Using Abdominal Computed Tomography with Clinical Variables : Application of Deep Learning with a Convolutional Neural Network (멀티 모달리티 데이터 활용을 통한 골다공증 단계 다중 분류 시스템 개발: 합성곱 신경망 기반의 딥러닝 적용)

  • Tae Jun Ha;Hee Sang Kim;Seong Uk Kang;DooHee Lee;Woo Jin Kim;Ki Won Moon;Hyun-Soo Choi;Jeong Hyun Kim;Yoon Kim;So Hyeon Bak;Sang Won Park
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.187-201
    • /
    • 2024
  • Osteoporosis is a major health issue globally, often remaining undetected until a fracture occurs. To facilitate early detection, deep learning (DL) models were developed to classify osteoporosis using abdominal computed tomography (CT) scans. This study was conducted using retrospectively collected data from 3,012 contrast-enhanced abdominal CT scans. The DL models developed in this study were constructed for using image data, demographic/clinical information, and multi-modality data, respectively. Patients were categorized into the normal, osteopenia, and osteoporosis groups based on their T-scores, obtained from dual-energy X-ray absorptiometry, into normal, osteopenia, and osteoporosis groups. The models showed high accuracy and effectiveness, with the combined data model performing the best, achieving an area under the receiver operating characteristic curve of 0.94 and an accuracy of 0.80. The image-based model also performed well, while the demographic data model had lower accuracy and effectiveness. In addition, the DL model was interpreted by gradient-weighted class activation mapping (Grad-CAM) to highlight clinically relevant features in the images, revealing the femoral neck as a common site for fractures. The study shows that DL can accurately identify osteoporosis stages from clinical data, indicating the potential of abdominal CT scans in early osteoporosis detection and reducing fracture risks with prompt treatment.

Spatio-Temporal Monitoring of Soil CO2 Fluxes and Concentrations after Artificial CO2 Release (인위적 CO2 누출에 따른 토양 CO2 플럭스와 농도의 시공간적 모니터링)

  • Kim, Hyun-Jun;Han, Seung Hyun;Kim, Seongjun;Yun, Hyeon Min;Jun, Seong-Chun;Son, Yowhan
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.2
    • /
    • pp.93-104
    • /
    • 2017
  • CCS (Carbon Capture and Storage) is a technical process to capture $CO_2$ from industrial and energy-based sources, to transfer and sequestrate impressed $CO_2$ in geological formations, oceans, or mineral carbonates. However, potential $CO_2$ leakage exists and causes environmental problems. Thus, this study was conducted to analyze the spatial and temporal variations of $CO_2$ fluxes and concentrations after artificial $CO_2$ release. The Environmental Impact Evaluation Test Facility (EIT) was built in Eumseong, Korea in 2015. Approximately 34kg $CO_2$ /day/zone were injected at Zones 2, 3, and 4 among the total of 5 zones from October 26 to 30, 2015. $CO_2$ fluxes were measured every 30 minutes at the surface at 0m, 1.5m, 2.5m, and 10m from the $CO_2$ releasing well using LI-8100A until November 13, 2015, and $CO_2$ concentrations were measured once a day at 15cm, 30cm, and 60cm depths at every 0m, 1.5m, 2.5m, 5m, and 10m from the well using GA5000 until November 28, 2015. $CO_2$ flux at 0m from the well started increasing on the fifth day after $CO_2$ release started, and continued to increase until November 13 even though the artificial $CO_2$ release stopped. $CO_2$ fluxes measured at 2.5m, 5.0m, and 10m from the well were not significantly different with each other. On the other hand, soil $CO_2$ concentration was shown as 38.4% at 60cm depth at 0m from the well in Zone 3 on the next day after $CO_2$ release started. Soil $CO_2$ was horizontally spreaded overtime, and detected up to 5m away from the well in all zones until $CO_2$ release stopped. Also, soil $CO_2$ concentrations at 30cm and 60cm depths at 0m from the well were measured similarly as $50.6{\pm}25.4%$ and $55.3{\pm}25.6%$, respectively, followed by 30cm depth ($31.3{\pm}17.2%$) which was significantly lower than those measured at the other depths on the final day of $CO_2$ release period. Soil $CO_2$ concentrations at all depths in all zones were gradually decreased for about 1 month after $CO_2$ release stopped, but still higher than those of the first day after $CO_2$ release stared. In conclusion, the closer the distance from the well and the deeper the depth, the higher $CO_2$ fluxes and concentrations occurred. Also, long-term monitoring should be required because the leaked $CO_2$ gas can remains in the soil for a long time even if the leakage stopped.

Dietary Effects of an Animal Fat with High Free- Fatty Acid Content on Feed Utilization and Meat Quality in Broilers (고산가 동물성 지방의 첨가가 육계의 사료이용성과 육질에 미치는 영향)

  • 오미향;지규만;최인숙
    • Korean Journal of Poultry Science
    • /
    • v.12 no.1
    • /
    • pp.7-16
    • /
    • 1985
  • Present experiment was undertaken to compare the effects of two dietary fats whose free fatty acid content was quite different on performances and on meat quality of broilers. Yellow grease or animal fat (trade name) containing 15 or 38.6% free fatty acid, respectively, was added to the broiler starter and finisher diets at levels of 3.0 and 5,0%, respectively. A total of 108, day old, male Maniker(Chunho) broiler chicks was alloted to 3 dietary treatments with 3 replications per treatment and 12 chicks per replication Though control diet was not supplemented with fat, the three dietary groups were made isocaloric and isonitrogenous. All the chicks were ad libitum fed the test diets for 8 weeks. Feed intake and body weight were measured every other week. Shank color was measured at the end of feeding trial by Roche Color Fan. To evaluate meat quality, 7 chicks of mean body weight were selected from each treatment group after the trial. Measurements were made for abdominal fat content, organoleptic scores for thigh and breast, and for contents of total lipids, free fatty acids, iodine values and peroxide values of the breasts. During the period from 0 to 4 weeks of age, the broilers fed the diets added with fats performed the same as those fed the control diet. However, the body weight gam (25%), feed intake (10.8%) and feed efficiency (11.3%) of chicks fed the fat-supplemented diets, during the finisher period (5-8 weeks), appeared significantly improved compared to those of control group (p<0.05). During overall period of 8 weeks, body weight gain, feed intake, and feed efficiency of chicks fed the diets added with fats were, on the average, 16.2. 8.8 and 6.8%, respectively, better than, those of control Monwhile the performance between the chicks fed diets added with the two different fat sources appeared to be of the same tendency. Though the shank pigmentation was not statistically different among the treatments, the chicks fed the fat-supple ented diets tended to have slightly less pigments than the control. Organoleptic scores of thigh or breast of chicks fed the animal fat diet were of the same range as those of the other two groups. The contents of total lipids, free fatty acids, iodine values and peroxide values of breasts from broilers fed the various diets appeared to be in the same ranges among the treatments. The values for control, yellow grease and animal fat groups were 7.77, 6.66 and 6.32% for total lipids, 9.23, 9.7 and 9.31mg oleic acid/g fat for free fatty acids, 65.36, 63.89 and 59.25g/ 100g fat for iodine values, and 9.62, 10.46 and 8.79 meq/kg fat for peroxide values, respect vely. Changes of free fatty acids contents of breast during a storage for 10 da s at 4$^{\circ}C$ were also not different among the dietary groups. From the observations n. this experiment, it seems possible to conclude that the animal fat containing 38.6% free fatty acid can be used as efficiently as yellow grease in broiler diets without any adverse effects on meat quality.

  • PDF

Comparative Analysis of Patterns of Care Study of Radiotherapy for Esophageal Cancer among Three Countries: South Korea, Japan and the United States (한국, 미국, 일본의 식도암 방사선 치료에 대한 PCS($1998{\sim}1999$) 결과의 비교 분석)

  • Hur, Won-Joo;Choi, Young-Min;Kim, Jeung-Kee;Lee, Hyung-Sik;Choi, Seok-Reyol;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.83-90
    • /
    • 2008
  • Purpose: For the first time, a nationwide survey of the Patterns of Care Study(PCS) for the various radiotherapy treatments of esophageal cancer was carried out in South Korea. In order to observe the different parameters, as well as offer a solid cooperative system, we compared the Korean results with those observed in the United States(US) and Japan. Materials and Methods: Two hundreds forty-six esophageal cancer patients from 21 institutions were enrolled in the South Korean study. The patients received radiation theraphy(RT) from 1998 to 1999. In order to compare these results with those from the United States, a published study by Suntharalingam, which included 414 patients[treated by Radiotherapy(RT)] from 59 institutions between 1996 and 1999 was chosen. In order to compare the South Korean with the Japanese data, we choose two different studies. The results published by Gomi were selected as the surgery group, in which 220 esophageal cancer patients were analyzed from 76 facilities. The patients underwent surgery and received RT with or without chemotherapy between 1998 and 2001. The non-surgery group originated from a study by Murakami, in which 385 patients were treated either by RT alone or RT with chemotherapy, but no surgery, between 1999 and 2001. Results: The median age of enrolled patients was highest in the Japanese non-surgery group(71 years old). The gender ratio was approximately 9:1(male:female) in both the Korean and Japanese studies, whereas females made up 23.1% of the study population in the US study. Adenocarcinoma outnumbered squamous cell carcinoma in the US study, whereas squamous cell carcinoma was more prevalent both the Korean and Japanese studies(Korea 96.3%, Japan 98%). An esophagogram, endoscopy, and chest CT scan were the main modalities of diagnostic evaluation used in all three countries. The US and Japan used the abdominal CT scan more frequently than the abdominal ultrasonography. Radiotherapy alone treatment was most rarely used in the US study(9.5%), compared to the Korean(23.2%) and Japanese(39%) studies. The combination of the three modalities(Surgery+RT+Chemotherapy) was performed least often in Korea(11.8%) compared to the Japanese(49.5%) and US(32.8%) studies. Chemotherapy(89%) and chemotherapy with concurrent chemoradiotherapy(97%) was most frequently used in the US study. Fluorouracil(5-FU) and Cisplatin were the most preferred drug treatments used in all three countries. The median radiation dose was 50.4 Gy in the US study, as compared to 55.8 Gy in the Korean study regardless of whether an operation was performed. However, in Japan, different median doses were delivered for the surgery(48 Gy) and non-surgery groups(60 Gy). Conclusion: Although some aspects of the evaluation of esophageal cancer and its various treatment modalities were heterogeneous among the three countries surveyed, we found no remarkable differences in the RT dose or technique, which includes the number of portals and energy beams.

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF