• Title/Summary/Keyword: 초전센서

Search Result 105, Processing Time 0.035 seconds

Fabrication of Superconducting Transition Edge Sensors based on Ti/Au Bilayer Formation (Ti/Au 이중층을 이용한 초전도 상전이 센서 제작)

  • Lee, Young-Hwa;Kim, Yong-Hamb
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.10
    • /
    • pp.943-949
    • /
    • 2008
  • We report on the development of transition edge sensors for x-ray detection. The sensor technology was based on the fabrication of a superconducting film on a thin membrane. A bilayer of a superconductor, Ti, and a noble metal, Au, was e-beam evaporated on a micromachined SiNx. Another Au layer was evaporated on the two side edges of the bilayer in order not to be affected by structural imperfections at the boundaries. With the method described in the present report, the superconducting transition temperature of the device was consistently achieved to near 80 mK with a sharp transition. The energy spectrum ueasured with the device provided 37 eV FWHM for 5.9 x-rays. We also discuss the design and fabrication considerations as well as the performance of the device in detail.

The development and physical properties of perovskite dielectrics in ceramic material (페로브스카이트 유전체 세라믹 재료의 발전과 물성)

  • Lee, Jin;Hong, Kyoung-Jin
    • Electrical & Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.73-79
    • /
    • 1994
  • 페로브스카이트형 강유전체의 활발한 연구는 제2차 세계대전중 미국과 구 소련등에서 TiO$_{2}$ 고체 콘덴서를 개량하던 중에 Ba 이 첨가된 BaTiO$_{3}$를 발견하면서부터 시작되었고, 일본에서는 PbZr$_{0.5}$Ti$_{0.5}$O$_{3}$의 morphotropic phase boundary를 발견하면서부터 이루어졌으며, 그것이 지니는 특성때문에 고체콘덴서, 초전형 적외선 센서, 초음파 발생과 검출기, 압전 점화기 및 표면파필터기 등 여러방면에 실용화 되고 있다. 따라서, 본 보고에서는 지금까지 연구된 페로브스카이트형 강유전체 세라믹 재료의 물성을 소개하고 앞으로의 연구동향 등에 관하여 서술하고자 한다.

  • PDF

Study on the control methods of compositional ratios in co-evaporation system for SmBCO coated conductor (동시 증발 증착법을 이용한 SmBCO 초전도층 증착에서 조성비 제어 방법에 관한 연구)

  • Kim, H.S.;Ha, H.S.;Oh, S.S.;Ko, R.K.;Song, K.J.;Ha, D.W.;Kim, T.H.;Youm, D.J.;Lee, N.J.;Moon, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.294-294
    • /
    • 2008
  • 동시 증발 증착법 화합물의 구성원자를 독립적으로 증발시켜서 기판에 증착하는 방법이다. 각 물질은 온도에 따른 증기압을 가지는데 각 물질의 온도를 조절하여 증착률을 조절한다. 보트에서 떠난 원자가 기판에 도달할 확률은 챔버의 진공도, 보토와 기판과의 거리 등에 의하여 영향을 받는다. 진공도가 나쁠수록, 보트와 기판과의 거리가 멀수록 기판에 도달할 확률이 떨어진다. 동시증발 증착법을 이용한 SmBCO 초전도층 증착에서 각 물질의 기판에 도달하는 원자비를 조절하기 위하여 QCM(증착률 측정장치), QCM 가이드를 사용하였다. QCM sensor 입구에 튜브형태의 QCM 가이드를 설치하고 QCM 가이드가 특정한 물질의 증발보트를 향하도록 배치하였다. 따라서 각 보트에서 떠난 원자들은 특정한 QCM sensor에 도달하게 되고 결국 3원소(Sm, Ba, Cu)의 증착률의 비를 조절함으로써 조성비를 조절할 수 있게 된다. QCM 증착률의 비와 실제 조성비는 여러 가지 변수에 의하여 영향을 받는 다. 대표적인 변수는 챔버의 진공도, QCM 가이드의 직경 및 길이, QCM 센서와 보트와의 거리 등이 있다. 진공도가 높을수록 특정 보트에서 떠난 원자들이 QCM 가이드 입구에 도달할 확률이 낮아지고, QCM 가이드의 직경이 좁을수록 가이드 내벽에 흡착될 확률이 높아진다. 또한 QCM센서와 보트와의 거리가 멀수록 챔버내 잔류가스의 원자들과 충돌확률이 높아지므로 도달확률이 줄어들게 된다. 동시 증발 증확법에서 조성비의 재현성을 높이기 위해서는 매회 증착실험에서 진공도가 일정해야 하며, QCM 가이드와 보트와의 거리를 되도록 최소화 하고, QCM 직경을 크게 하는 것이 유리하다.

  • PDF

Fabrication and Characterization of High Temperature in-situ Ramp-edge Type Josephson Junction (고온초전도체 in-situ ramp-edge 형태의 조셉슨 접합 제작 및 특성)

  • Hur, Yun-Sung;Kim, Jin-Tae;Hwang, Yun-Seok;Lee, Sun-Gul;Park, Gwang-Seo;Kim, In-Seon;Park, Yong-Ki;Park, Jong-Chul
    • Korean Journal of Materials Research
    • /
    • v.8 no.3
    • /
    • pp.263-267
    • /
    • 1998
  • In this study, we have fabricated in-situ multilayer $YBa_2Cu_3O_{7-\delta}$/$SrTiO_{3}$/$YBa_2Cu_3O_{7-\delta}$ ramp edge type junctions by using a metal mask and pulsed laser deposition method and studied the junction properties. The junctions showed RSJ-like I-V characteristics. The normal state junction resistance R, of $18 \omega$ was nearly constant with temperature. The dc-SQUID sensors fabricated with the junctions show a sensitivity that transfer function dV/$d\Phi$)~$22\mu$V/$\Phi_{0}$, indicating that the in-situ ramp edge type junction is potentially useful for sensor application.

  • PDF

Fabrication of a HTS SQUID Magnetometer for Magnetocardiogram (심자도 측정용 고온초전도 SQUID magnetometer의 제작)

  • Kim, In-Seon;Lee, Sang-Kil;Kim, Jin-Mok;Kwon, Hyuk-Chan;Lee, Yong-Ho;Park, Yon-Ki;Park, Jong-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.258-264
    • /
    • 1997
  • $YBa_{2}Cu_{3}O_{7}$ single layer dc SQUID magnetometers, prepared on $1\;cm^{2}\;SrTiO_{3}$ substrates, have been fabricated and characterized. Based on the analytical description, a SQUID magnetometer design having a 8.5 mm pickup coil with 2.6 mm linewidth, and a SQUID inductance Ls = 50 pH with $3\;{\mu}m$ Josephson junctions is presented. The devices showed a maximum modulation voltage depth of $65\;{\mu}V$ and a magnetic field noise of 0.6 pT /$\sqrt{Hz}$ at 1 Hz. Clear traces of human magnetocardiogram could be obtained with the SQUID magnetometer operating at 77 K.

  • PDF

Hallym Jikimi: A Remote Monitoring System for Daily Activities of Elders Living Alone (한림 지킴이: 독거노인 일상 활동 원격 모니터링 시스템)

  • Lee, Seon-Woo;Kim, Yong-Joong;Lee, Gi-Sup;Kim, Byung-Jung
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.4
    • /
    • pp.244-254
    • /
    • 2009
  • This paper describes a remote system to monitor the circadian behavioral patterns of elders who live alone. The proposed system was designed and implemented to provide more conveniently and reliably the required functionalities of a remote monitoring system for elders based on the development of first phase prototype[2]. The developed system is composed of an in-house sensing system and a server system. The in-house sensing system is a set of wireless sensor nodes which have pyroelectric infrared (PIR) sensor to detect a motion of elder. Each sensing node sends its detection signal to a home gateway via wireless link. The home gateway stores the received signals into a remote database. The server system is composed of a database server and a web server, which provides web-based monitoring system to caregivers (friends, family and social workers) for more cost effective intelligent care service. The improved second phase system can provide 'automatic diagnosis', 'going out detection', and enhanced user interface functionalities. We have evaluated the first and second phase monitoring systems from real field experiments of 3/4 months continuous operation with installation of 9/15 elders' houses, respectively. The experimental results show the promising possibilities to estimate the behavioral patterns and the current status of elder even though the simplicity of sensing capability.

The quench detection technique of the superconducting magnet using an AE sensor (AE센서를 이용한 초전도자석의 퀜치 검출기법)

  • Kim, Ho-Min;Lee, Bang-Woo;Oh, Il-Sung;Lee, Hai-Gun;Iwasa, Yukikazu
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1748-1750
    • /
    • 2004
  • This paper deals with the detection method of the Quench phenomenon for superconducting magnet using the Acoustic Emission (AE) sensor. AE sensor is the elements, which is used to change the Acoustic signal to the voltage value. This signal may be used to detect whether the superconducting magnet has been at the Quench state or not. Recently, the development of the Quench detection technique, which is the using voltage and current signals, fiber-optic sensor, and so on, for the superconducting applications is widely studying. This method for the Quench detection of the superconducting magnet is also studying at some kinds of institute in Japan and the united state. Because of the large-scale superconducting magnet like International Thermonuclear Experimental Reactor(ITER) is charged a lot of energy, when the Quench phenomenon is being at the superconducting magnet it is happen to the problem of the protection for the applications. In this paper, we concluded that the Quench detection was possible when the mechanical stress by means of the local heat is generated at the part of inside superconducting magnets.

  • PDF

Partial discharge measurement of artificial defects applying HFCT sensor for HTS transformer (HFCT를 이용한 HTS 변압기에서의 인위적 결함에 대한 부분방전 측정)

  • Shin, Woo-Ju;Park, Tae-Gun;Lee, Sang-Hwa;Koo, Ja-Yoon;Lee, Bang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1459_1460
    • /
    • 2009
  • 고전압 대전력 기기인 고온초전도(HTS) 변압기는 기기내의 불순물과 작은 결함에서 발생되는 부분방전이 장시간 지속되어 심각한 고장으로 발전한다. 그러므로 기기의 고장을 미연에 발견하고 예방진단 할 수 있는 다양한 진단 기술이 확립 되어야 한다. 본 논문은 기존의 변압기내 절연유에서 발생될 수 있는 다양한 결함 중 기포, 돌기, 권선과 권선사이, 자율금속 이물질 이렇게 4가지 타입의 모의결함을 제작하여 실험 하였다. 기존의 전력설비 부분방전 진단 시 사용되는 IEC60270 규격으로 실험하여 측정한 데이터 바탕으로 Labview program을 이용하여 자체 개발한 PRPD 분석 프로그램과 오실로스코프를 연동하고 HFCT 센서를 이용하여 취득한 데이터를 비교 분석하였다. 그 결과 IEC60270 측정데이터와 Labview 프로그램을 이용하여 나온 결과 값이 유사하게 나왔다는 것을 알 수 있었다.

  • PDF

Pyroelectric infrared microsensors made by micromachining technology (마이크로 가공 기술을 이용한 강유전체 박막 초전형 적외선 센서)

  • 최준임
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.4
    • /
    • pp.93-100
    • /
    • 1998
  • Pyoelectric infrared detectors based on La-modified PbTiO3 (PLT) thin films have been fabricated by RF magnetron sputtering and micromachining technology. The detectors form Pb$_{1-x}$ La$_{x}$Ti$_{1-x}$ O$_{3}$ (x=0.05) thin film ferroelectric capacitors epitaxially grown by RF magnetron sputtering on Pt/MgO (100) substrate. The sputtered PLT thin film exhibits highly c-axis oriented crystal struture that no poling trealization for sensing applications is required. This is an essential factor to increase the yield for realization of an infrared image sensor. Micromachining technology is used to lower the thermal mass of the detector by giving maximum sensor efficiency. Polyimide is coated on top of the sensing elements to support the fragile structure and the backside of the MgO substrate is selectively eteched to reduce the heat loss. The sensing element exhibited a very high detectivity D* of 8.5*10$^{8}$ cm..root.Hz/W at room temperature and it is about 100 times higher than the case of micromachining technology is not used. a sensing system that detects the position as well as the existence of a human body is realized using the array sensor.sor.

  • PDF

Sensor Calibration of a Helmet MEG System (헬멧형 뇌자도 장치의 센서 교정)

  • Kwon, H.;Kim, K.;Yu, K.K.;Kim, J.M.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.57-61
    • /
    • 2010
  • We have developed a whole-head MEG system for basic brain research and clinical application. The sensor system consists of a 152 SQUID gradiometer array oriented and located in a suitable way to cover a whole head of the human. The system measures magnetic fields generated by neuronal currents in the brain to get information on the brain activities. For this purpose, the field sensitivity determined by the position, orientation and geometry of the pickup coil as well as amplification factor of the electronic circuits should be known precisely. However, the position and orientation of the pickup coil might be changed from the designed specifications during cool down of the dewar and it is necessary to characterize the field sensitivity. In this study, we made calibration systems to determine the actual position and orientation of the 152 pickup coils and compared the localization results of the N100m source in the auditory cortex.