• Title/Summary/Keyword: 초전도 tube

Search Result 201, Processing Time 0.023 seconds

The study of the Characteristic of the Coaxial Type Inertance Pulse Tube Refrigerators (관성관형 동축 맥동관 냉동기의 특성에 관한 연구)

  • 김양훈;박성제;홍용주;김효봉;이승홍
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.33-35
    • /
    • 2003
  • There are three types that geometrical arrangement of the pulse tube and regenerator - in line type, U type, and coaxial type. The most compact and convenient one practical applications is the coaxial type. It can replace Stirling cryocooler without any change to the Dewar or the connection to the cooled devices. To investigate effects of the inertance tube, we perform experiments with varying inertance tube inner diameter and length. The experimental results show that optimum inertance tube inner diameter and length are 1.3mm, 1900mm respectively.

  • PDF

Study of the performance characteristics of the Stirling type orifice pulse tube refrigerator (스터링헝 오리피스 맥동관 냉동기의 성능특성에 관한 연구)

  • 홍용주;박성제;김효봉;김양훈;최영돈
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.63-67
    • /
    • 2002
  • In this study, the performance of the Stirling type orifice Pulse tube refrigerator (OPTR) with a linear compressor was investigated by experiment. The dynamic pressures at three points and a temperature at the cold heat exchanger are measured to explore the dependency of the orifice on the performance of the OPTR. The experimental results show that the opening of the orifice has significant effects on the no load temperature and cool down characteristics. The Pressure amplitude in Pulse tube decrease as the opening of the orifice increase, but the mass flow rate through the orifice and the electric input Power to the compressor increase. The results show that the operating frequency and charging Pressure does not affect on the no load temperature. The pressure amplitude in pulse tube decrease as the operating frequency increase or the charging Pressure decreased.

형상에 따른 초전도 튜브의 전기적 특성변화

  • Jang, G.E.;Park, C.W.;Ha, D.W.;Seung, T.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.527-530
    • /
    • 2004
  • High-temperature Superconductor(HTS) tubes were fabricated in term of different diameter, length and thickness by centrigugal forming method. For powder melting by induction the optimum range of melting temperatures and preheating temperature were $1050^{\circ}C{\sim}1100^{\circ}C\;amd\;550^{\circ}C$ for 30min, respectively. The mould renting speed was 1000rpm. A tube was annealed at $840^{\circ}C$ for 72hours in oxygen atmosphere. The plate-like grains were well developed along the renting direction and typical grain size was about more than $40{\mu}m$. It was found that Ic values increased with increasing the tube diameter while the Ic decreased with increasing tube thickness. Also Ic decreased with increasing the tube length. The measured Ic in $50mm{\times}70mm{\times}25mm$ tube was about 896Amp.

  • PDF

A study on the in-line type inertance tube pulse tube cryocooler for cooling Superconductor filter

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Kim, Seon-Young;Jung, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.46-50
    • /
    • 2004
  • The Experimental results of the in-line type inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. The pulse tube refrigerator, which has no moving parts at its cold section, is attractive in obtaining higher reliability, simpler construction, and lower vibration than any other small refrigerators. The purpose of this study is to analyze the characteristics of in-line type inertance tube pulse tube refrigerator (IPTR), and to get main factor to improve the performance of the in-line type IPTR. Firstly, design parameters of the in-line IPTR are discussed by ARCOPTR program, and then to find optimal conditions of in-line type IPTR, cool down characteristics according to the variations of the charging pressure, inertance tube volume, regenerator volume and pulse tube volume are measured by the experiment. The lowest temperature of the cold end was about 50 K. Cooling capacity was the highest in the charging pressure of 32 atm. and 5W at 72K. On the other hand, COP of the in-line type IPTR was the highest in the charging pressure of 21 atm. and 0.018 at 77K.

An Experimental Investigation of the G-M type Pulse Tube Refrigerator

  • Park, Seong-Je;Koh, Deuk-Yong;Yeom, Han-Kil;Hong, Yong-Ju;Kim, Hyo-Bong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.40-45
    • /
    • 2004
  • The experimental results of the G-M (Gifford-McMahon) type pulse tube refrigerators are presented in this paper. The pulse tube refrigerator, which has no moving parts at its cold section, is attractive in obtaining higher reliability, simpler construction, and lower vibration than any other small refrigerators. The objectives of this study are to develop the design technology of the G-M type pulse tube refrigerator and acquire its application methods for replacing G-M cryocooler. As a preliminary test, the refrigeration performances of the basic, orifice, and double inlet pulse tube refrigerators were investigated. The lowest temperature obtained in the one-stage pulse tube refrigerator was 34.4K and the refrigeration capacity at the optimum operation condition was 23W at 80K. And the lowest temperature of the second stage cold head in the two-stage pulse tube refrigerators was 18.3K and the refrigeration capacities at optimum condition were 0.45W at 20K and 20W at 80K, respectively. Finally, the lowest temperature obtained in the three-stage pulse tube refrigerator was 29.8K and the refrigeration capacity at the optimum operation condition was 1.3W for 40K and 5W for 70K.

Orientation dependence of GM-type pulse tube refrigerator (GM형 맥동관 냉동기의 저온부 경사도에 따른 냉각 성능 특성 연구)

  • Ko, Jun-Seok;Kim, Hyo-Bong;Park, Seong-Je;Hong, Yong-Ju;Yeom, Han-Kil;Lee, Chung-Soo;Kang, In-Su;Koh, Deuk-Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.48-52
    • /
    • 2012
  • This paper describes experimental study on the orientation dependence of GM-type pulse tube refrigerator with helium and neon as working gas. A pulse tube refrigerator generates refrigeration work with gas expansion by gas displacer in the pulse tube. The pulse tube is only filled with working gas and there exists secondary flow due to large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube with orifice valve as a phase control device is fabricated and tested. The fabricated pulse tube refrigerator is tested with two different working gases of helium and neon. First, optimal valve opening and operating frequency are determined with experimental results of no-load test. And then, the variation of no-load temperature as orientation angle of cold-head is measured for two different working gases. Effect of orientation dependence of cold-head as working gas is discussed with experimental results.

Experimental Study on a GM-type Two-Stage Pulse Tube Refrigerator for Cryopump Applications

  • Lee, S.J.;Hong, Y.J.;Park, S.J.;Kim, H.B.;Kwon, S.B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.2
    • /
    • pp.35-38
    • /
    • 2007
  • A single-stage and two-stage pulse tube refrigerators have been designed for cryopump application. The different diameters of pulse tube and regenerator have been investigated at single-stage pulse tube refrigerator(PTR). Experiments have been performed on single-stage PTR to reach minimum temperature with optimum valve opening at a few frequencies. And the two-stage pulse tube refrigerators have been assembled with tested single-stage pulse tube and tested. When orifice turn is opened to 9 and double inlet is opened to 3 at a single-stage, the lowest temperature of 33.7 K is achieved. The cooling capacity at single-stage is 38 W at temperature of 80 K. A two-stage pulse tube refrigerator has 16.3K at the second stage and 59.7K at the first stage. The cooling capacity achieved is 16.5 W at 80 K, the first stage and 0.6 W at 20 K, the second stage. Some details on the design of pulse tube refrigerator and the experimental apparatus are given.

Superfluid Shock Tube Facility and Measurement Methods (초유동 충격파관관 장치 및 측정수단)

  • ;H. Nagai;Y. Ueta;K. Yanaka;M. Murakami
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.202-204
    • /
    • 2002
  • The supurfluid shock tube facility has been developed as a versatile tool for experimental research of low-temperature thermo-fluid dynamic phenomena The shock tube is designed to operate with the He II filled test section which is immersed in superfluid helium. The thermo-dynamic phenomena occurred in this facility are measured using pressure transducers, superconductive temperature sensor and visualization method. In this paper, the design and performance of the superfluid shock tube facility and the superconductive temperature sensor is presented.

  • PDF

Experimental study on the transfer in pulse tube (맥동관 내부의 열전달에 관한 실험적 연구)

  • 김민규;남관우;정상권;장호일;정은수
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.1
    • /
    • pp.45-50
    • /
    • 2000
  • The present study has been conducted to observe the heat transfer under pulsating pressure and oscillating flow. The experimental apparatus was fabricated to measure the gas temperature, the wall temperature. the pressure and the instantaneous heat flux inside the pulse tube. The measured gas temperature and heat flux must be calibarated to compensate their finite time constant in the oscillating flow conditious. The experiment was performed from 1 Hz to 5 Hz. The phase difference between the instantaneous heat flux and the gas-wall temperature difference was clearly observed. The experimental heat fluxes were compared to the theroretical correlations such as Complex Nusselt Number Model(CNNM) and Variable Coefficient Model(CVM). The heat flux predisted by CNNM was always greater than that of VCM. The experiment confirmed the valisity of the VCM for the instantaneous heat flux under the pulsating pressure and oscillating flow in the warm end of the pulse tube.

  • PDF