• Title/Summary/Keyword: 초전도 tube

Search Result 201, Processing Time 0.021 seconds

Study of Stirling Cryocooler Performance with different length of split tube (Split tube 길이변화에 따른 스터링 극저온 냉동기의 특성에 관한 연구)

  • 홍용주;박성제;고득용;김효봉;오군섭;김종학
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.37-40
    • /
    • 2001
  • A free piston and free displacer (FPFD) Stirling cryocooler for cooling infrared and cryo-sensor is currently under development at Korea Institute of Machinery & Materials. In this study, performance tests of stirling cryocooler with different length of split tube were performed to get characteristics of cryocooler. The Experimental results show the Stirling cryocooler with small volume of split tube has higher cooling power and faster response time.

  • PDF

Experiment and adiabatic analysis of miniature inertance pulse tube refrigerator (소형 관성관형 맥동관 냉동기의 실험 및 단열 해석)

  • 남중원;남관우;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.53-58
    • /
    • 2004
  • A Miniature inertance pulse tube refrigerator was designed and tested with a 10 W compressor. Erperiments were carried out for different pulse tube length and inertance tube length. An adiabatic model which considered the pressure drop in the regenerator was used to analyze the performance of the pulse tube refrigerator. Among various design parameters which should be optimized, the pulse tube length and the inertance tube length were optimized. PdV work and several different loss mechanism were included in the analysis to simulate more accurately the physical phenomena in the pulse tube refrigerator. Nevertheless, the simulation program could not completely predict the porformance of the refrigerator. The possible reason for the difference of the optimal point between the simulation and the experiment was explained.

Design of compact phase controller for pulse tube refrigerator

  • Ki, Tae-Kyung;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.2
    • /
    • pp.25-28
    • /
    • 2011
  • A compact phase controller of pulse tube refrigerator is proposed in this paper. Most pulse tube refrigerators available now consist of a long inertance tube and reservoir as the phase controller. The long inertance tube and reservoir present a challenge for compact packaging in some applications. To overcome this disadvantage, the long inertance tube and reservoir are replaced with the compact phase controller consisted of mass, spring and damper in pulse tube refrigerator. This process is achieved using similarity of mechanical, electrical, and acoustic system and the specific configuration of the compact phase controller is designed. From the simulation code in this paper, the performance of pulse tube refrigerator with the designed compact phase controller is confirmed to be comparable to pulse tube refrigerator with the long inertance tube and reservoir.

Characteristics of BSCCO Superconductor Tube Using Partial Melting Process (부분용융법을 이용한 BSCCO 초전도 튜브 특성)

  • 박용민;장건익
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.25-28
    • /
    • 2001
  • Bi-2212 HTS tube was fabricated by centrifugal forming process(CFP). As a variation of melt casting process(MCP) or centrifugal casting technique, the centrifugal forming process is a flexible method for manufacturing Bi-2212 bulk tubes and has been optimized to achieve smooth surface and uniform thickness. At this process, the slurry was prepared in the mixing ratio of 10:1 between Bi-2212 powder and binder and initially charged into the rotating mold under the speed of 300~450 rpm Heat-treatment was performed at the temperature ranges of 860 ~ $890^{\circ}C$ in air for partial melting. The HTS tube fabricated by centrifugal forming process at $890^{\circ}C$ under the rotating speed of 450 rpm was highly densified and the plate-like grains with more than 20$\mu$m were well oriented along the rotating axis. The measured Tc and Jc at 10K were around 85K and 3,000A/cm2 respectively.

  • PDF

A study on the modeling of the inertance tube in the pulse tube refrigerator (맥동관 냉동기에서 관성관의 모델링에 관한 연구)

  • 남관우;정상권
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.153-156
    • /
    • 1999
  • In this paper, the inertance tube is modeled by the distributed impedance model. This model is verified by the analytical solutions for the long tube without the reservoir. In this model the distributed impedace effect of the inertance tube is included and mass flow rate and pressure distributions are calculated along the inertance tube for various inertance tube lengths. Mass flow rate at the inlet of the inertance tube is also calculated by this model and compared to the lumped impedance method. Mass flow rate by the distributed model shows quite different behaviors from the lumped model when the operating frequency is high and the length of the tube becomes large.

  • PDF

An experimental study of magnetic diffusion in Bi-2212 High-Tc supercondutor tube (Bi-2212 고온초전도체 튜브의 자기확산에 관한 연구)

  • 정성기;설승윤
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.66-70
    • /
    • 2003
  • Transient magnetic diffusion process in a melt-cast Bi2Sr2CaCu20X(Bi-2212) tube was studied by experimental and numerical analyses. The transient diffusion partial differential equation is transformed into an ordinary differential equation by integral method. The penetration depth of magnetic field into a superconducting tube is obtained by solving the differential equation numerically. The results show that the penetration depth as a function of time which is somewhat different from the results by Bean's critical state model. The reason of the difference between the present results and that of Bean's model is discussed and compared in this paper. This experiment measure the magnetic flux density in the supercondutor after supply direct-current of Bi-2212 rounded by copper coil. This study was discussed of valid of a previous numerical solution which is compared by the penetrate time and the magnetic flux density difference of between the present results and the numerical solution.

Characteristics of HTS tube fabricated by centrifugal forming process (원심성형법으로 제조한 고온초전도 튜브의 특성 분석)

  • Jang, Gun-Eik;Park, Yong-Min
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.211-215
    • /
    • 2000
  • Bi-2212 HTS tube was fabricated by CFP(Centrifugal Forming Process). Slury was prepared in the mixing ratio of 8:2 between powder and binder and ball-milled for 24 hrs. Slurry was initially charged into the rotating mold with 300${\sim}$450 rpm and heated at the temperature ranges of 840${\sim}$860$^{\circ}$C for partial melting to finally obtain a uniformly textured tube shape. It was observed the plate-like grains with more than 20 ${\mu}$m were well oriented along the rotating axis and the measured T$_c$ was around 67K. In this paper we will discuss and analyze the tube characteristics depending on many different processing parameters such as, powder composition, binder mixing ratio between powder and binder, motor speed, heating temperature and etc.

  • PDF

초전도 박막형 선재

  • 이상헌
    • 전기의세계
    • /
    • v.53 no.8
    • /
    • pp.39-42
    • /
    • 2004
  • 초전도 재료는 선재의 형태로 가공하면 송전선이나, 변압기, 발전기 및 전력 저장장치와 같이 전력 응용의 효율을 극대화시킬 수 있는 재료로서 널리 활용되고 있다. 1987년 개발된 고온 산화물 초전도체는 액체질소 의 비등점인 77K 이상에서 초전도 현상을 나타내어 초전도 현상의 응용에 대한 기대를 고조시켜 이에 대한 연구 개발을 더욱 향상시키고 있다. 초전도 선재에 관한 연구는 주로 PIT( Powder in Tube )공정을 이용한 Ag/Bi 2223 선재가 우수한 전기적 특성과 가공의 우수성으로 인하여 개발되어 왔다. 그러나 Ag/Bi 2223 선재는 강한 자기장 하에서 통전 특성이 현저하게 저하되는 결점이 있다. (중략)

  • PDF

An Experimental Study on the 1st Harmonic Characteristic for open-tube-type and close-tube-type Thermoacoustic Refrigerators (개방관형과 밀폐관형 열음향 냉동기의 1차 하모닉에 관한 특성 연구)

  • 송규조;박종호;고득용;박성제;김효봉;정철진
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.189-192
    • /
    • 2002
  • In this study, The experimental open-tube-type and close-tube-type thermoacoustic refrigerator were constructed. The resonant characteristics of a thermoacoustic refrigerator were investigated. In order to determine the optimum resonant tube length and frequency, We changed the length of resonant tube from 400mm to 850mm and the frequency from 100Hz to 1000Hz. In case of first harmonic, the temperature difference of open-tube-type (1/4 wave) refrigerator was $41^{\circ}C$(resonator length :500mm). The temperature difference of close-tube-type (1/2 wave) refrigerator was $43^{\circ}C$(resonator length :850mm). In this experiments, the experimental 1/2 wave refrigerator is slightly cooler than the experimental l/4 wave refrigerator.

  • PDF

An Experimental Study on the Characteristics for Open-Tube and Close-Tube Thermoacoustic Effects(1) - The 1st Harmonic (개방관과 밀폐관의 열음향 효과에 관한 하모닉 특성 연구(1) - 1차 하모닉)

  • 송규조;이성노
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.129-134
    • /
    • 2002
  • In this study, the experimental open-tube and close-tube thermoacoustic apparatuses were constructed. In order to determine the optimum length of resonant tube, frequency and the optimum length of stack, the resonant characteristics of thermoacoustic apparatuses were investigated, The length of resonant tube varies from 400mm to 850 mm. The experimental frequency varies from 100 Hz to 1000 Hz. In case of first harmonic, the maximum temperature difference of the open-tube thermoacoustic apparatus is 41$^{\circ}C$)resonator length: 500 mm), and the maximum temperature difference of the close-tube thermoacoustic apparatus is 42$^{\circ}C$ (resonator length : 850 mm).