• Title/Summary/Keyword: 초음파 C 스캔

Search Result 39, Processing Time 0.024 seconds

Enhancement of Ultrasonic C-scan Images for Inspection of Multi-layered Composite Panels (다층 후판 복합재 패널의 결함 검출을 위한 C-Scan 이미지 보정기법)

  • Cho Hyun;Song Sung-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.264-267
    • /
    • 2006
  • One of the serious problems that make the flaw identification in a multi-layered thick composite panel more difficult is the interferenceeffect of the upper layer. To take care of such a problem, here we propose an image enhancement approach that can get rid of such an interference effect to ultrasonic C-scan images by a normalization of the acquired signals by a reference signals, and demonstrate its performance in the experiments. Specifically, three specimens with artificial flaws are prepared and ultrasonic C-scan images are acquired experimentally to eliminate the undesired interference effect. Cleat successes are observed in the present study demonstrating the high potential of the proposed algorithm as a practical image enhancement tool in many practical situations.

  • PDF

Nondestructive evaluation of spot weld quality using by ultrasonic measurement (초음파계측에 의한 SPOT용접품질의 비파괴평가)

  • 박익근
    • Journal of Welding and Joining
    • /
    • v.12 no.3
    • /
    • pp.109-117
    • /
    • 1994
  • Spot welding has wide used with a high work efficiency in the automotive and aerospace industries. Up to the present, the technique mainly used to test spot welds on production lines has been entirely depended upon destructive chisel or peel testing. Therefore, it's being very important assignment to secure the NDE technique which can be evaluate spot weld quality with more efficiency and high reliability. This paper discusses the feasibility of UNDE techniques to evaluate spot weld quality. For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of a the corona bond from nugget, ultrasonic c-scan image and distribution of reflective echo amplitude was measured by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). As the results of this study, corona bond which is the most dangerous types of interface defects can be successfully detected, as well as expulsion and voids. Ultrasonic testing results were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be successfully measured with the accuracy of 0.8 mm.

  • PDF

Vibration-Based Nondestructive Evaluation of Thermal Stress-Induced Damage in Thin Composite Laminates (복합 적층 박판의 열응력 파손에 대한 진동 활용 비파괴평가)

  • Lee, Sung-Hyuk;Choi, Nak-Sam;Lee, Jong-Ki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.347-355
    • /
    • 1999
  • A feasibility investigation on vibration-based nondestructive evaluation of thermal stress-induced micro-failure in the free edge region of thin composite laminates(1mm thick) has been carried out. The failure occurrence and damage zone, which were predicted by the three-dimensional finite-element thermal stress analysis, were observed using the ultrasonic C-scan and optical microscopy. Analysis of the vibration spectrum measured from the laminate beam specimens by the vibration sweep test exhibited that the obvious decrease in resonancy frequency and some considerable increase in damping factor were associated with the micro-failure formation. The vibration technique utilizing short beam and high resonant frequency was found to be very sensitive to the thermal stress-induced damage in the thin laminates.

  • PDF

The Usefulness of $^{99m}Tc$-Sestamibi Scan in Preoperative Localization in Primary Hyperparathyroidism (원발성 부갑상선 기능 항진증의 수술전 병소확인에서 $^{99m}Tc$-Sestamibi 스캔의 유용성)

  • Baik, S.H.;Kim, S.M.;Choi, K.M.;Choi, Y.S.;Kim, S.J.;Yu, J.M.;Choi, D.S.;Choe, J.C.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.465-472
    • /
    • 1995
  • An accurate preoperative localization in patients with primary hyperparathyroidism is important for successful surgical intervention. There are many methods for the localization of the primary hyperparathyroidism such as ultrasonography, computerized tomography(CT), magnetic resonance imaging(MRI), angiography and $^{201}T1/^{99m}Tc$ subtraction scan. Among them $^{201}T1/^{99m}Tc$ subtraction scan is known as the most accurate tool for preoperative localization. Recently $^{99m}Tc$-Sestamibi has been used for parathyroid gland imaging. We experienced 19 primary hyperparathyroidisms accurately localized with $^{201}T1/^{99m}Tc$ subtraction imaging and $^{99m}Tc$-Sestamibi. The sensitivities of the $^{99m}Tc$-Sestanibi, $^{201}T1/^{99m}Tc$ subtraction imaging, CT and US were 100%(5/5), 89.5%(17/19) and 61.7(12/19) respectively. With the combination of $^{99m}Tc$-Sestamibi and $^{201}T1/^{99m}Tc$ subtraction imaging we could localize with 100% accuracy. Although the case number is small, this study suggests that the $^{99m}Tc$-Sestamibi parathyroid scan is very useful and easy to use for preoperative localization in primary hyperparathyroidism.

  • PDF

Feasibility Study on Ultrasonic Waveguide Sensor for Under-Sodium Viewing of Reactor Internals in Sodium-Cooled Fast Reactor (소듐냉각고속로 원자로 내부구조물의 소듐내부가시화를 위한 웨이브가이드 초음파센서의 적용 가능성 연구)

  • Joo, Young-Sang;Lim, Sa-Hoe;Park, Chang-Gyu;Lee, Jae-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.364-371
    • /
    • 2008
  • Ultrasonic waveguide sensor has been developed for under-sodium viewing of reactor internal structures of a sodium-cooled fast reactor (SFR). The structure design concept of a waveguide sensor assembly was suggested and evaluated for the application in SFR. A 10 m long ultrasonic waveguide sensor assembly has been manufactured and the experimental feasibility tests were carried out. The 10 m long distance propagation performance of zero-order antisymmetric $A_0$ Lamb wave has been verified. The feasibility of ultrasonic waveguide sensor has been demonstrated by the C-scanning resolution performance test.

The Decision of Voiding Cystourethrography in Children with Urinary Tract Infection (소아 요로감염에서 배뇨성 방광 요도 조영술의 결정)

  • Kim, Dong-Woon;Choi, Eung-Sang;Lim, In-Seok
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.203-211
    • /
    • 2007
  • Purpose : We attempted to compare the independent factors such as age, sex, C-reactive protein(CRP), and white blood cell count(WBC) in children with radiologic studies and assess the necessity of performing voiding cystourethrography(VCUG). Method : 98 children who have been diagnosed their first time febrile urinary tract infection from Janurary 2002 to Januray 2005 were enrolled. In all patient, the duration of fever which occurred before and after treatment was recorded, and CRP, WBC, $^{99m}Tc$-2,3-dimercaptosuccinic acid($^{99m}Tc$-DMSA) renal scans, renal ultrasound and VCUG were analyzed. Results : Of the 98 children diagnosed with urinary tract infection(UTI), 52 were male and 46 were female. 18 had abnormalities in VCUG, 17 had abnormalities in kidney ultrasound, and 20 had partial defects or diffuse uptake decrease in $^{99m}Tc$-DMSA renal scans. There were no significant relationship between incidence of radiologic abnormalities and age. The risk of renal scar was significantly higher in children who had a longer febrile period before treatment than in those with shorter period. Both CRP and WBC were significantly elevated in children with the radiological abnormalities. A positive of $^{99m}Tc$-DMSA renal scans and renal ultrasound were highly associated with vesicoureteral reflux(VUR). Conclusion : If there are abnormalities in the kidney ultrasound and $^{99m}Tc$-DMSA renal scan of a child with initial UTI, a VCUG is recommended. Even in cases without abnormal findings in $^{99m}Tc$-DMSA renal scan and renal ultrasound, clinical data such as CRP and WBC should be assessed, and VCUG should be Performed for the undetected VUR.

  • PDF

Attenuation Estimation of Soft Tissue by the Entropy Method and Statistical Averaging of Speckle Patterns (스펙클 패턴의 통계적 평균과 엔트로피 방식에 의한 초음파 감쇄계수 추정방법)

  • Song, T.K;Park, J.C;Park, S.B
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.253-260
    • /
    • 1989
  • The time domain methods of estimating the attenuation coefficient are generally based on the analysis of statisical properties of the reflected echoes form an attenuating medium. Hence, it is often required to have a large number of data samples in order to obtain a statistically stable estimation result. In the attenuation estimation problem, this means that many different speckle patterns are required in the spatial resolution volume of an attenLlation image. In this paper, by using the fact that the speckle pattern Is sensitive to the point spread function of the ultrasound beam, we suggest a method to generate the statiscally uncorrelated or slightly correlated data samples in a given region by rotating a linear transducer and carrying out lateral scans for all rotating angles. This technique is applied to the entropy method for attenuation estimation proposed recently by the authors where the performance is verified by experiments using a tissue equivalent phantom.

  • PDF

Low velocity Impact Characteristics of Non-flamable Composite Laminates (난연성 복합적층재의 저속충격특성)

  • 김재훈;김후식;조정미;박병준
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.179-182
    • /
    • 2001
  • Impacter tester was build of to evaluate the characterization of non-flamable Glass/phenol laminate plates under the low velocity impact. The damage of composite laminates are matrix cracking, delamination, and fiber breakage for impact energy. In this study, this is to find impact properties of Glass/phenol in used in a forehead part of lighting subway. To determine impact damage characteristics which is made in a laminate, use the UT C-scan after- macrography. And then evaluated the reduction of strength in a rate of impact energy with CAI(Compression After Impact) test

  • PDF

Low Velocity Impact Characteristics of Glass/phenol Composite Laminates (Glass/phenol 복합적층판의 저속충격 특성)

  • Kim, Jae-Hoon;Kim, Hu-Shik;Park, Byoung-Joon;An, Byoung-Wook
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.228-233
    • /
    • 2001
  • It is well known that composite laminates are easily damaged by low velocity impact. The damage of composite laminates subjected to impact loading are occurred matrix cracking, delamination, and fiber breakage. The damage of matrix cracking and delamination are reduced suddenly the compressive strength after impact. This study is to evaluate impact characteristics and the relationship between impact force and inside damage of composite laminates by low velocity impact loading. UT C-scan is used to determine impact damage areas by impact loading.

  • PDF

Development of 3D Image Processing Software using EMD for Ultrasonic NDE (EMD를 이용한 초음파 비파괴 평가용 3차원 영상처리 소프트웨어 개발)

  • Nam, Myung-Woo;Lee, Young-Seock;Yang, Ok-Yul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1569-1573
    • /
    • 2008
  • This paper describes a development of Ultrasonic NDE software to analyze steam generator of nuclear power plant. The developed software includes classical analysis method such as A, B, C and D-scan images. And it can analyze the detected internal cracks using 3D image processing method. To do such, we obtain raw data from specimens of real pipeline of power plants, and get the envelope signal using Empirical Mode Decomposition from obtained ultrasonic 1-dimensional data. The reconstructed 3D crack images offer useful information about the location, shape and size of cracks, even if there is no special 2D image analysis technique. The developed analysis software is applied to specimens containing various cracks with known dimensions. The results of application showed that the developed software provided accurate and enhanced 2D images and reconstructed 3D image of cracks.