• Title/Summary/Keyword: 초음파 진단

Search Result 1,356, Processing Time 0.031 seconds

A Study on the Diagnostic Usefulness of Ultrasound and Magnetic Resonance Imaging for the Diagnosis of Shoulder Rotator Cuff Tear (어깨 회전근개 파열 진단을 위한 초음파 검사와 자기공명영상 검사의 진단적 유용성 연구)

  • Chae-Won, Kang;Hyo-Young, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.961-968
    • /
    • 2022
  • Rotator cuff tears are a leading cause of shoulder pain in adults. Due to the increase in social activities, the number of patients complaining of shoulder pain is increasing, and interest in shoulder diseases is also increasing. With the development of ultrasound equipment, the sensitivity and specificity of diagnosis are high, and it is used to diagnose rotator cuff tears in musculoskeletal disease. Ultrasound is recognized as a complementary method to MRI examination in rotator cuff tears. Therefore, this study aimed to find out the diagnostic usefulness of ultrasound and MRI examinations in the diagnosis of shoulder rotator cuff tears.A retrospective analysis was performed on 262 patients who were diagnosed with final rotator cuff damage by arthroscopy after completing ultrasound and MRI examinations. Sensitivity, feature, positive predictive value, image predictive value, and touch were disassembled for the test results. In addition, the degree of clavicular tear was scored and recorded in 5 stages. Ultrasound examination was similar to MRI examination results for both full-thickness and partial tears, and there was no statistically significant difference. Partial tear test results showed higher positive predictive value and accuracy than MRI test. In conclusion, ultrasound can be fully utilized as a screening test for rotator cuff disease, and it is thought that it will be selected and used clinically according to the patient's constitution and situation.

A Study on Ultrasound Pulsed Doppler Systems for Sending the Blood Flow (혈류 진단을 위한 초음파 펄스 도플러 시스템에 관한 연구)

  • Kim, Seong-Ryul;Kim, Jin-Ha;Park, Song-Bae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.5
    • /
    • pp.33-40
    • /
    • 1984
  • In the conventional pulsed doppler system, gated CW is used to excite a ultrasonic transducer so that a group of linear RF amplifiers are required to excite a ultrasonic array transducer in the scanning pulsed doppler system. A pulsed doppler system without linear high voltage RF amplifiers, which excites the transducer impulsively, is studied theoretically and experimentally. In this paper, an experimental 8-channel pulsed doppler system is implemented, which uses quadrature defection to detect the direction of motion and can compensate the attenuation effect. The designed pulsed doppler system shows the possibility of real time multichannel doppler flow meter.

  • PDF

Ultrasonographic Diagnosis of Right Atrial Vegetative Endocarditis in a Cow (우의 우심방증식성심내막염의 초음파단층영상진단 1예)

  • Kweon Oh-Kyeong
    • Journal of the korean veterinary medical association
    • /
    • v.24 no.1
    • /
    • pp.19-24
    • /
    • 1988
  • A lactating Holstein cow which did not have had responded to drug therapy during 2 months was clinically examined. Right atrial vegetative endocarditis was determined dy ultrasonographic diagnosis, and later it was confirmed at necropsy. An early systolic

  • PDF

Assessment of Ultrasonic Pulse Velocity Method for Early Detection of Frost Damage in Concrete (콘크리트의 초기동해 진단을 위한 초음파 속도법의 적용 가능성 평가)

  • Moon, Sohee;Lee, Taegyu;Choi, Heesup;Choi, Hyeonggil
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.2
    • /
    • pp.193-202
    • /
    • 2024
  • This research delves into the evaluation of the suitability of ultrasonic pulse velocity as a diagnostic tool for early detection of frost damage in concrete. The investigation involves the measurement of compressive strength and ultrasonic pulse velocity concerning the depth of freezing for individual mortar specimens, followed by an analysis of their microstructure and their interrelation. The findings indicate a consistent decrease in both compressive strength and ultrasonic pulse velocity with increasing freezing depth. Furthermore, a correlation between compressive strength and ultrasonic pulse velocity concerning the depth of early frost damage is established. Consequently, the study asserts the potential of utilizing the ultrasonic pulse velocity method for early detection of frost damage in concrete, with prospects for quantifying the depth of damage through further research endeavors.

Leiomyosarcoma Mimicking Superficial Cystic Soft Tissue Mass Confusing Diagnosis On Ultrasonography - A Case Report - (초음파 진단 시 혼란을 초래할 수 있는 연부 조직 종양 - 1례 보고 -)

  • Park, Tae-Soo;Kim, Sungjun;Park, Hwon-Kyum;Park, Yong-Wook;Seo, Seung-Pyo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.90-93
    • /
    • 2009
  • In spite of many advantages of the ultrasonography (USG), sometimes its features such as echotexture and homogenecity do not reliably distinguish between malignant tumors and benign ones, so caution is needed in making a diagnosis of solid masses of the soft tissue with USG.

  • PDF

Analysis of image using fibroscan value in the Ultrasound of Elastography for liver lesions (간병변 초음파영상에서의 탄성초음파를 이용한 영상분석)

  • Lee, Jeong-Hyun;Kim, Jung Hun;Kim, Changsoo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.433-434
    • /
    • 2014
  • 최근 간질환 검사의 비침습적인 방법으로 탄성초음파가 각광받고 있는 추세이다. 그러나 진단결과와 탄성초음파 결과 값에 따른 표준 진단 매뉴얼이 없는 실정이다. 따라서 본 연구에서는 탄성초음파 수치에 따른 간질환의 종류와 B-mode 영상 간의 경향을 알아보고자 하였다. 그리고 환자의 우측 늑간 초음파 B-mode 영상평가 파라미터인 평균, 신호 대 잡음비, 최대신호 대 잡음비, 엔트로피로 분석하고, 동일 부위에 시행한 탄성초음파 수치와의 비교를 통해 경향을 연구하였고, 그 기준을 제시하고자 하였다.

  • PDF

Ultrasonographic Diagnosis in the Knee (슬관절에서의 초음파적 진단)

  • Min, Kyoung-Dae
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.28-37
    • /
    • 2013
  • Ultrasound is a first line examination of the knee and useful diagnostic tool in assessing the various knee lesions. The advantages of ultrasound are that it is non-invasive, easily available at bed side, cheap, well accepted by patients, and that it has technical benefits including dynamic evaluation. Its limitations include reliability, which is largely operator dependent and its inability to evaluate deep structures. Technical guidelines of the ultrasound released by European Society of MusculoSkeletal Radiology (ESSR) and ultrasonographic findings of various knee lesions are described.

  • PDF

Harmonic generation emitted from ultrasonic contrast agent in response to a typical diagnostic ultrasound (전형적인 진단용 초음파에 의해 초음파 조영제에서 방사하는 하모닉 성분의 크기)

  • Choi M. J.;Kang K. S.;Paeng D. G.;Rhim S. M.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.373-378
    • /
    • 2004
  • 하모니 영상은 초음파의 비선형 전파 과정에서 발생된 하모닉 성분을 영상화 한다. 하모닉 영상은 초음파에 비선형적으로 반응하는 초음파 조영제를 사용하여 하모닉 성분의 발생을 최대화 하고 있다. 일반적으로 현재 임상적으로 사용되는 하모닉 영상은 2차 고주파 성분을 사용한 것을 의미한다. 2차 하모닉 영상은 주파수의 상승으로 공간 분해능이 향상된다. 초음파 조영제를 이용하는 경우 서브 하모닉, 울트라 하모닉의 발생도 유의할 것으로 기대되지만 이에 대한 연구는 거의 없는 실정이다. 서브 하모닉은 상대적으로 2차 하모닉보다 전파 과정에서 감쇠 효과가 작기 때문에 심부의 영상에 유리하다 서브 하모닉 및 울트라 하모닉 성분 검출은 초음파 변환기의 대역폭에 대한 제한을 2차 하모닉에 비해 상대적으로 덜 받는다. 본 연구에서는 진단용 초음파에 의해 초음파 조영제에서 방사하는 하모닉 성분의 크기를 시뮬레이션 하였다. 수치해석은 Gilmore Equation을 이용하였으며, 초음파 조영제의 탄성 효과는 무시하였다. 초음파 조영제의 크기와 초음파의 MI에 따라 하모닉 성분의 크기를 정량적으로 비교하고, 서브 및 울트라 하모닉 영상의 구현에 대해 토의하였다.

  • PDF

Fatty Liver Diagnostics from Medical Examination to Analyze the Accuracy Between the Abdominal Ultrasonography and Liver Hounsfield Units (건강검진에서 지방간 진단의 상복부초음파검사와 간 Hounsfield Units 측정값과의 정확성 분석)

  • Oh, Wang-Kyun;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.229-235
    • /
    • 2017
  • In abdominal Ultrasonography, the fatty liver is diagnosed through hepatic parenchymal echo increased parenchymal density and unclear blood vessel boundary, and according to many studies, abdominal Ultrasonography has 60~90% of sensitivity and 84~95% of specificity in diagnosis of fatty liver, but the result of Ultrasonography is dependent on operators, so there can be difference among operators, and quantitative measurement of fatty infiltration is impossible. Among examinees who same day received abdominal Ultrasonography and chest computed tomography (CT), patients who were diagnosed with a fatty liver in the Ultrasonography were measured with liver Hounsfield Units (HU) of chest CT imaging to analyze the accuracy of the fatty liver diagnosis. Among 720 subject examinees, those who were diagnosed with a fatty liver through abdominal Ultrasonography by family physicians were 448, which is 62.2%. The result of Liver HU measurement in the chest CT imaging of those who were diagnosed with a fatty liver showed that 175 out of 720 had the measured value of less than 40 HU, which is 24.3%, and 173 were included to the 175 among 448 who were diagnosed through Ultrasonography, so 98.9% corresponded. This indicates that the operators' subjective ability has a great impact on diagnosis of lesion in Ultrasonography diagnosis of a fatty liver, and that in check up chest CT, under 40 HU in the measurement of Liver HU can be used for reference materials in diagnosis of a fatty liver.

Diagnostic Performance of Combined Single Photon Emission Computed Tomographic Scintimammography and Ultrasonography Based on Computer-Aided Diagnosis for Breast Cancer (유방 SPECT 및 초음파 컴퓨터진단시스템 결합의 유방암 진단성능)

  • Hwang, Kyung-Hoon;Lee, Jun-Gu;Kim, Jong-Hyo;Lee, Hyung-Ji;Om, Kyong-Sik;Lee, Byeong-Il;Choi, Duck-Joo;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.201-208
    • /
    • 2007
  • Purpose: We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). Materials and methods: We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors). The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Results: Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve = 0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve =0.860), but there was no statistical differerence in sensitivity, specificity and accuracy between the combined method and a single modality. Conclusion: It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer.