• Title/Summary/Keyword: 초음파 진단장치

Search Result 75, Processing Time 0.025 seconds

Study on a Real Time Quantitative Diagnostic Technique for Measuring CVD Precursors (CVD 공정의 전구체 잔존량 실시간 진단방법 연구)

  • Yun Ju-Young;Shin Yong-Hyoen;Chung Kwang-Hwa
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.110-114
    • /
    • 2005
  • This study proposes an accurate method of monitoring precursor consumption in chemical vapor deposition (CVD) systems. Since precursor costs are significant, finding an efficient method to monitor precursor consumption is necessary One example is the use of non-contact and inexpensive ultrasonic sensors for determining the liquid level in a container. In this study, sensors based on ultrasonic techniques have been developed for monitoring the precursor consumption in a CVD system. Moreover, the prototype sensors developed in this study can be useful in the field of semiconductors.

An implementation of the continuous wave doppler system for blood flow measurement using the ultrasound (효율적인 혈류 속도 측정을 위한 연속 초음파 도플러 장치의 구현)

  • 박형재;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.516-519
    • /
    • 2001
  • To diagnose a patient's blood vessel disease, apoplexy, hypertension, arteriosclerosis, the blood velocity is very important. Determining the blood velocity methods using ultrasound are Continuous Doppler System and Pulse Doppler System. In using the Pulse Doppler System, we can obtain the position of blood velocity. But it is more complex hardware than Continuous Doppler System and it has low SNR(signal-noise ratio). So in this study, to obtain a believable information we use the Continuous Pulse Doppler System. Thus system have analog part and digital part. In analog part is composed of ultrasound generating part, the amplifying part to amplify the received signal from ultrasound sensor, the demodulation part to detect blood velocity and the filtering part to remove the noise. In digital part is composed of the A/D conversion part, digital signal processing part, and the communication part to communicate the PC. In this study to implement efficient ultrasound blood velocity measurement system, we can get the patient's blood velocity information in realtime. Thus, It is a useful in the accurate diagnosis with C.T(computered tomography), M.R.I(magnetic resonance imaging).

  • PDF

A study on Ultrasound Urine Alarm System for Incontinence Patients (뇨실금 환자를 위한 초음파 뇨의 경보 시스템에 관한 연구)

  • 최흥호;최창근;이응혁
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.1
    • /
    • pp.101-108
    • /
    • 2001
  • 본 논문에서는 뇨실금 환자들에 대한 지원 기술의 일환으로 인체에 무해하고 비침습적인 초음파를 이용하여 배뇨시기를 알려주기 위한 재택용 뇨의 경보기용 뇨량검출 센서의 개발과 이를 이용한 방광 벽간거리와 뇨량과의 상관관계에 관하여 연구하였다. 개발된 센서는 인체내에 침투력이 가장 좋은 중심 주파수가 2.25 MHz인 초음파를 사용하여 분해능을 높여 오차를 감소시킬 수 있는 구조로 설계하였다. 이 센서를 이용하여 방광전.후벽간의 거리를 검출하여 이로부터 뇨량을 정량적으로 측정하기 위한 기초 실험을 실시하였다. 기초실험은 건강한 성인 남자 3명을 대상으로 초음파 뇨량검출 센서를 이용한 초음파 RF 반사신호 획득장치와 초음파 진단기에 의한 2가지 방법으로 이루어졌고 그 결과 뇨량과 벽간거리와의 사이에는 높은 상관성이 있음을 확인할 수 있었다. 결론적으로, 실험 결과를 토대로 하여 제작된 초음파 뇨의 센서를 부착한 초음파 뇨의 경보 시스템은 뇨실금 환자로 하여금 배뇨시기를 알려주는 경보 시스템으로 보건.복지적인 측면에서 현대사회에 기여할 공헌도가 매우 클 것이라 생각된다.

  • PDF

Relationship between corpus luteum size as determined by ultrasonography and milk progesterone concentration during the estrous cycle in dairy cows (젖소에서 발정주기중 초음파 진단장치로 측정된 황체의 크기와 progesterone 농도와의 관계)

  • Son, Chang-ho;Kang, Byong-kyu;Choi, Han-sun
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.4
    • /
    • pp.833-841
    • /
    • 1995
  • Ultrasonography was used to measure the corpus luteum area for determining the relationships between corpus luteum size and milk progesterone concentration during the estrous cycle in 16 dairy cows. Cows were classified retrospectively into cows that had corpus luteum with(n=P) and without(n=7) cavity. Ultrasound examination and collection of milk samples for progesterone assay were performed with 2 day intervals from Days 0 to 12, and then daily from Day 14 to the day of the next ovulation. The means for corpus luteum area and for milk progesterone concentration during the estrous cycle were not significantly different between cows that had corpus luteum with and without cavity. The correlation coefficients between corpus luteum area and milk progesterone concentration during luteal development (Days 2 to 8) were 0.71(p<0.0001) and 0.74(p<0.0001) for corpus luteum with and without cavity, respectively, during luteal regression(Days -6 to 0 relative to the next ovulation) 0.73(p<0.0001) and 0.76(p<0.0001), respectively. The correlation coefficients combined fur both stages of estrous cycle and both luteal statuses were 0.70(p<0.0001). These results indicate that corpus luteum area is significantly correlated to milk progesterone concentration, and ultrasonographic assessment of the corpus luteum is a reliable method fur estimating peripheral progesterone concentrations during the estrous cycle in cows.

  • PDF

Development of a Multi-Channel Ultrasonic Testing System for Automated Ultrasonic Pipe Inspection of Nuclear Power Plant (원전 배관 자동 초음파 검사를 위한 다채널 초음파 시스템 개발)

  • Lee, Hee-Jong;Cho, Chan-Hee;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.145-152
    • /
    • 2009
  • Currently almost all in-service-inspection techniques, applied in domestic nuclear power plants, are partial to field inspection technique. These kinds of techniques are related to managing nuclear power plants by the operation of foreign-produced inspection devices. There have been so many needsfor development of native in-service-inspection device because there is no native diagnosis device for nuclear power plant inspection yet in Korea. In this research, we developed several core techniques to make an automated ultrasonic pipe inspection system for nuclear power plants. A high performance multi-channel ultrasonic pulser/receiver module, an A/D converter module and a digital main CPU module were developed and the performance of the developed modules was verified. The S/N ratio, noise level and signal acquisition performance of the developed modules showed proper level as we designed in the beginning.

Ultrasound Attenuation in the Assessment of Bone Mineral Density and Elastic Modulus of Human Trabecular Bone

  • Han, S.M.;Kim, M.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.171-176
    • /
    • 1998
  • The objective of this study was to re-evaluate ultrasound attenuation as an indicator of bone properties. Ultrasound attenuation(BUA), were measured in the three orthogonal directions of trabecular bone cubes, Measurements of bone mineral density(BMD) were made using quantitative computed tomography and apparent density by weighing bone specimens and measuring their volume. Ultrasonic modulus was calculated from the standard equation with apparent density and ultrasound velocity. Ultrasound attenuation at a frequency of 0.5 MHz and BUA were correlated with BMD and ultrasonic modulus in the anterior/posterior, medial/lateral, and superior/inferior directions. Analysis of correlations demonstrated that attenuation at 0.5 MHz was superior to BUA in describing both BMD and elastic modulus of trabecular bone. This result may be used to improve current ultrasound diagnostic techniques for assessing bone status.

  • PDF

Implementation of Capacitance Measurement Equipment for Fault Diagnosis of Multi-channel Ultrasonic Probe (다중채널 초음파 프로브 고장진단을 위한 커패시턴스 측정 장치 구현)

  • Kang, Bub-Joo;Kim, Yang-soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.175-184
    • /
    • 2016
  • In this paper, we propose the method to measure the capacitances using not LCR meter but capacitance to voltage(C/V) conversion. And we design the analog MUX circuits that convert 192 channels to 6 MUX channels in order to implement the diagnosis of multi-channel ultrasonic probe. This paper derives the conversion function that converts the digital voltage of each MUX channel to the capacitance using the least squares method because the circuit characteristics that convert the voltage of each MUX channel to the capacitance are different. The developed prototype illustrates the performance test results that the measure times are measured by within 4sec and the measure error rates of maximum, minimum, and average values are within 5% in terms of the repeated measurements of all 192 channels.

A Study on the Improving the Resolution using Synthetic Focusing in B-mode Ultrasound Imaging System (B-mode 초음파 진단장치에서 합성 집속방법에 의한 해상도 증대에 관한 연구)

  • 배무호;정목근
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.14-22
    • /
    • 1998
  • 기존의 널리 사용되는 초음파 영상진단기에서는 수신집속은 모든 점에 대해 행하는 것이 가능하지만 송신접속은 미리 정해진 수 개의 점에 대해서만 행하는 한계가 있다. 본 논문에서는 영상화할 대상이 정지해 있거나 매우 느리게 움직이는 경우에 한하여, 송신음장 의 집속은 합성집속방법(synthetic focusing)을 사용하고, 수신집속은 동적 집속(dynamic receive focusing)을 이용함으로써 모든 영상점에서 송수신 집속하여 측방향 해상도를 향상 시키는 방법을 제안하였다. 컴퓨터 시뮬레이션 결과 초점깊이에서와 같은 해상도를 유지하 는 음장거리(fields of depth)가 기존의 방법에 비하여 월등히 우수하였으며, 3.5MHz의 선형 배열변환기를 이용하여 펜텀 영상에 대한 실험 결과도 모든 영상 깊이에서 측방향 해상도가 기존의 B-mode의 영상보다 우수하였다.

  • PDF

Studies on Live-carcass Trait of Parity and Region in Hanwoo Cows Measured by Real-time Ultrasound (초음파 진단장치를 이용한 한우 암소의 산차 및 지역별 산육특성 구명)

  • Ha, Jae-Jung;Kim, Jong-Bok;Lee, Chang-Woo;Song, Young-Han
    • Journal of Animal Science and Technology
    • /
    • v.51 no.3
    • /
    • pp.255-262
    • /
    • 2009
  • Current study was conducted to investigate the influence of parity and region variation in ultrasound live carcass traits of Hanwoo cows. A total of 1,386 heads of Hanwoo cows, spreading over six regions in Gangwon province of South Korea, were measured for longissimus muscle area, back fat thickness, marbling score and rump fat thickness by using real-time ultrasound method. The results revealed that, positive correlations were found in all ultrasound live carcass traits. All live carcass traits were increased in accordance with parity until the sixth, and then decreased thereafter. Statistical significant differences (p<0.01) were found among regions in ultrasound live carcass traits, e.g. Hanwoo cows showed highest longissimus muscle area and marbling score in Hwacheon, while the lowest back fat thickness and rump fat thickness were observed in Yanggu. Greater longissimus muscle area and marbling scores were found in Hanwoo cows which were born during autumn, 2000. Moreover, individuals born during autumn, 2005 and 2006 showed a thicker back fat and rump fat thickness. Back fat thickness had the highest positive correlation with rump fat thickness, while rib eye area and rump fat thickness had the lowest correlation.

Deterioration Diagnosis of Epoxy Mold-type Transformer Using Ultrasonic Waves (초음파를 이용한 에폭시 몰드변압기의 열화 진단)

  • 이상우;김인식;이동인;이광식;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.73-81
    • /
    • 1999
  • Measurements of ultrasonic signals caused by partial discharges were perlonnrl by using an ultrasonic measurement technique to diagnose the electrical treeing deterioration in an epoxy mold-type power transformer. We also examined the characteristics of tree growth, partial discharge magnitude and ultrasonic pulse number with the increase of the deterioration time. From these results, it was found that the shape of the tree was a branch-type, and the rates of the tree growth were examined when ac voltages of 16[kV] and 20[kV] were applied Ultrasonic pulse number and discharge magnitude were rapidly increased as the length of the tree grows after the middle stage of the deterioration time, and it appeared that ultrasonic pulse number was proportional to discharge magnitude. Attenuation, time-delaying and directivity characteristics of ultrasonic signals propagated into epoxy resin by using ultrasonic oscillation and receiving systems are also re[prted as a basic data of ultrasonic mesasurements in mold-type power transformer.former.

  • PDF