• Title/Summary/Keyword: 초음파 조사

Search Result 795, Processing Time 0.025 seconds

Ultrasonographic and Magnetic Resonance Imaging Findings of Testicular Lymphoma (고환림프종의 초음파검사 및 자기공명영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.2
    • /
    • pp.105-112
    • /
    • 2010
  • Purpose : To evaluate the specific radiologic findings of testicular lymphoma which will be able to differentiated from other testicular tumors. Materials and Methods : Pathologically confirmed eight cases were included in this study. All eight cases were performed ultrasonography and four cases were performed magnetic resonance image. On ultrasonography, the size, location, shape, margin, internal echogenicity, homogeneity and vascularity were evaluated. On magnetic resonance image, the shape, margin, homogeneity, signal intensity on T1- and T2-weighted images, degree and homogeneity of the contrast enhancement and contrast enhancement change on dynamic enhancement study. Results : The margin of the mass was smooth on 6 of 8 patients. Internal echogenicity of the mass lesion was hypoechoic than normal testicular parenchyme on 7 of 8 patients. Four cases were homogeneous, 3 cases were relatively homogeneous and 1 case was heterogeneous. All 8 cases showed increased vascularity. The mass lesion was iso-signal intensity on T1-weighted image and low-signal intensity on T2-weighted image. All four cases were enhanced homogeneously and mildly than enhancing normal testicular parenchyme. On dynamic enhancement study, the mass lesion is progressively enhanced with time. Conclusion : The possibility of testicular lymphoma should be considered when testicular mass was homogeneously hypoechoic and low signal intensity on T2-weighted image in old age patients.

  • PDF

Combined Effects of Ionizing Radiation and Ultrasound on Malformation in ICR Mice at Organogenesis stage

  • Gu, Yeun-Hwa;Hasegawa, Takeo;Mori, Takehiko;Yamamoto, Youichi;Kusama, Tomoko
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.23-30
    • /
    • 1999
  • Pregnant ICR mice were treated with 137Cs gamma-ray / ultrasound on day 8 of gestation. In combined treatments, pregnant mice were treated with both 1.5 Gy of radiation and $1.0W/cm^2$ ultrasound at time intervals of -1, 0, 1, 3 and 6 hours. The mortalities and external malformations were investigated on day 18 of gestation. The threshold dose of mortality induced by radiation on day 8 of gestation was between 0.5 and 1.0 Gy, and that which was induced by ultrasound was between 1.0 and $1.5W/cm^2$. The mortalities in the late-stage of gestation induced by combined treatment with radiation and ultrasound increased synergistically. The threshold dose of exencephaly and anophthalmia induced by radiation were between 0.5 and 1.0 Gy and between 1.0 and 1.5 Gy, respectively. Those of exencephaly and anophthalmia induced by ultrasound were between 1.0 and $1.5W/cm^2$ and more than $1.5W/cm^2$, respectively. In combined treatments, the incidence of exencephaly and anophthalmia were found to increase synergistically. In the mice treated with both agents at a time interval of one hour, the incidence of exencephaly and anophthalmia reached maximum levels.

  • PDF

Optimization of Antioxidant Extraction from Dandelion (Taraxacum officinale) Leaves Using BBD-RSM (BBD-RSM을 이용한 민들레로부터 항산화성분의 추출공정 최적화)

  • Han, Kyongho;Jang, Hyun Sik;Hong, In Kwon
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.408-414
    • /
    • 2019
  • In this study, an antioxidant was extracted from dandelion leaves using traditional hot water and ultrasonic extraction methods. In order to optimize the extraction yield and total flavonoid, an antioxidant, Box-Behnken design (BBD) model among response surface analysis methods was used. In the case of hot water extraction, the extraction temperature and time as well as the ratio of alcohol/ultrapure water were set as variables, and for the ultrasonic extraction, the ultrasonic survey century and irradiation time and the ratio of alcohol/ultrapure water were variables. Optimum extraction conditions in the hot water extraction method were the extraction temperature and time of $45.76^{\circ}C$ and 1.75 h and the ratio of alcohol/ultrapure water of 41.92 vol.%. While for the ultrasonic extraction method the survey century of 512.63 W, the ratio of alcohol/ultrapure water of 56.97 vol.% and the extraction time of 20.79 min were optimum conditions. Expected reaction yield and flavonoid content values under the optimized condition were calculated as 22.09 wt.% and 28.98 mg QE/mL dw, respectively. In addition, the error value of less than 3% was obtained validating our optimization process.

Effects of sonication on physicochemical properties and pore formation of maize starch (초음파처리가 옥수수전분의 이화학특성과 기공 형성에 미치는 영향)

  • Choi, Eun-Hee;Lee, Jae-Kwon
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.5
    • /
    • pp.507-512
    • /
    • 2017
  • The physicochemical properties of maize starch sonicated at various amplitudes (100, 200, and 300 W) and times (10, 30, and 50 min) were examined. The amount of enzyme-susceptible starch increased marginally after sonication. Sonication increased the amount of oil absorbed in the starch although the degree of oil absorption decreased with an extension of the sonication time, implied that different types and extent of damages occurred. Scanning electron microscopy revealed that ultrasound sonication did not form pores on the surfaces, but caused damages such as depression and erosion. Pasting viscosity of starch decreased with an increase in the severity of sonication conditions because of the weakened polymer network. X-ray diffraction suggested that the crystalline domains in starch were not susceptible to sonication and were more resistance to degradation. Sonicated starch formed more pin-holes on the surfaces in the initial glucoamylase reaction; subsequently, as the reaction proceeded, porous starch with enlarged pores was formed and finally, disrupted granular fragments were observed.

A Comparative Analysis between Duplication Stage Gage Data (이중화 수위계 자료 비교분석연구)

  • Kim, Hwi-Rin;Yoo, Chul-Sang;Cho, Hyo-Seob;Kim, Yang-Su
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1177-1180
    • /
    • 2009
  • 현재 국토해양부 4대강 홍수통제소에서는 369개의(2007년 한국수문조사연보 기준) 수위관측소를 설치 운영하고 있으며 현장에서 수집되는 수위자료의 측정방법은 부자식, 레이더식, 초음파식, 영상수위계 등 다양하다. 한강홍수통제소에서 자체 시험연구과제로 수행한 "TM 및 일반수위관측자료 비교분석연구" (국토 해양부, 2007)에 의하면 홍수예보를 위한 주요지점을 위주로 부자식과 레이더식, 부자식과 초음파식 등으로 수위계가 이중화 설치된 것으로 조사된 바 있다. 최근 홍수예보시 수위계 장비 자체의 결함이나 통신이상 등으로 발생되는 결측치나 이상치 자료를 최소화하기 위하여 주 관측방식이 부자식인 수위관측소에서 부자식 수위계의 기기 고장이나 부자 걸림 등이 발생되어 정상적인 자료 취득이 어려운 경우, 보조로 설치된 레이더식 또는 초음파식 수위계의 자료를 수신 받아 자료 손실을 최소화하고 주요지점의 자료 생산 제공 활용의 안정화를 도모하기 위함이다. 따라서 이러한 활용성을 극대화하기 위해 평상시 주 수위계와 보조 수위계에서 생산되는 자료를 동시에 저장하여 두 자료를 비교 분석하여 향후 홍수통제소에서 적용 가능한 자료관리 및 운영에 대한 개선방안을 제안하고자 한다.

  • PDF

A Study on the Application Characteristics of Ultrasonically Irradiated Bio-Diesel Fuel in Common-mil Direct Injection Diesel Engine (커먼레일 디젤기관에 초음파 조사 바이오디젤유 적용 특성에 관한 연구)

  • Choi Dooseuk;Jung Youngchul;Im Seukyeon;Ryu Jeongin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.109-114
    • /
    • 2006
  • The reformed bio-diesel fuel irradiated by the ultrasonic wave is applied to the diesel engine of common rail in common use recently. This study has the object to examine the properties of engine performance and discharged materials. The bio-diesel fuel is mixed and used with the diesel fuel in common use at the ratio of $20\%\;or\; 100\%$. The ultrasonic energy is irradiated to the individually mixed fuel in order to reform the fuel. This fuel is applied to the engine in this experiment. And It is compared and analyzed from the experimental results with two cases irradiating the ultrasonic wave and no irradiating.

Experimental Study on Cutting State of Glass by Ultrasonic Scriber (초음파 절단기에 의한 유리 절단면의 상태에 관한 실험적 검토)

  • Lee Chai-Bong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.6 no.4
    • /
    • pp.212-216
    • /
    • 2005
  • In an ultrasonic glass scriber, the effect of ultrasonic vibration and its optimum driving frequency were investigated experimentally. To investigate the optimum ultrasonic frequency theoretically, the vibration model of the ultrasonic scriber is assumed. The frequency for maximum amplitude of acceleration is obtained theoretically. To investigate the depth of cutting edge corresponding the each frequency. The quartz glass plate specimen with a dimension of $200mm(L){\times}30mm(W){\times}3mm(T)$ is selected. The ultrasonic transducer is operated by the constant acceleration amplitude for the every frequency. The maximum crack depth was generated when the driving frequency was 18.35kHz. These results were in good agreement with those of the calculated model theoretically.

  • PDF