• Title/Summary/Keyword: 초음파 조사

Search Result 795, Processing Time 0.025 seconds

Heating Characteristics Evaluation of Superposed Sonication Using Glycerol Tissue Mimic Phantom (글리세롤 조직유사 팬텀을 이용한 초음파 중첩 조사에 따른 가열 특성 평가)

  • Noh, Si-Cheol;Kang, Sang-Sik;Park, Ji-Koon;Kim, Ju-Young;Jung, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.523-528
    • /
    • 2015
  • In this study, we evaluated the heating characteristics of single sonication and superposed two low-intensity ultrasonic sonication. Compare the results, the superposed sonication was showed a superior thermal effect than single sonication. And the maximum temperature was increased as 120-150%. The starting time of temperature rising has been shortened in superposed sonication. In addition, the time up to the maximum temperature has been shortened, too. In generally, as the ultrasonic intensity is higher, the more surface damage is occurred. However, in the case of superposed sonication, the same thermal effect had be confirmed without surface damage. Through the results of the study, we thought that the superposed sonication will be able to reduce the intensity of the ultrasonic treatment. And, by using the low-intensity, the more safe and more effect therapy will be possible in therapeutic ultrasound application.

The Effects of ultrasonic irradition on germination of mung bean (녹두 발아에 미치는 초음파 조사의 영향)

  • Koh, Moo-Seok;Lee, Y.B.
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.18 no.2
    • /
    • pp.153-159
    • /
    • 1989
  • The experiment was carried out to examine on effect of ultrasonication on the growith of a mungbean while a mungbean is germinated and to measure amino acid content of a mungbean during its germination. Mungbean seeds soaked are divided into three groups; the first group was control group, untreated and naturally germinated. the second was ultrasonic treated group(UTG I), irradiated by ultrasonication for 8, 16 and 24min respectively immediately after soaking. the third was ultrasonic treated group(UTG II), irradiated by ultrasonication after 48hr germinating. The results were as foolows; Fresh weight, moisture, length of mungbean increased as its germination proceeds. while dry weight decreased. Ultrasonication tends to inhibit its germination of mungbean and results in the decrease in weight, length and moisture. Specially ultrasonication had a marked effect on UTG II. The longer the time of ultrasonication was, the more was the growth inhibited. In the control groups, the content of amino acid increased until 72 hours, but after that, it decreased. of the amino acid determined, glutamic acid decreased marekedly in the cotyledons, While the opposite was the case with aspartic acid in the hypocotyls. Comparing with the control groups, UTG I, the content of amino acid decreased. As the ultrasonic treaed time was increased, the concentration of amino acid in hypocotyl cotyledon tended to decreased. UTG II, the content of amino acid was lower than control groups, but higher than UTG I, and the effects of ultrasonication were similar to UTG I.

  • PDF

Sonolysis of Trichloroethylene in the Multi Ultrasound Irradiation Reactor (다중 초음파 조사 반응조에서의 TCE의 초음파 분해)

  • Lee, Min-Ju;Oh, Je-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.10
    • /
    • pp.873-882
    • /
    • 2009
  • Sonolysis of TCE (Trichloroethylene) was performed in 584 kHz rectangular reactor. At first, the effect of acoustic power and aqueous temperature which are both important factors to operate ultrasound system on sonolysis of TCE were examined under one side irradiation condition. First degradation rate constants of TCE and chloride yields were increased with increasing acoustic power from 100 to 300 W. And increasing the aqeuous temperature resulted in the increase of first degradation rate constants of TCE and the decrease of chloride yield. Sonolysis of TCE was performed under multi ultrasound irradiation conditions that total acoustic power of 300 W was distributed according to the number of irradiation sides. First degradation rate constants of TCE followed the order 4 sides > 3 sides > 1 side > 2 sides (parallel) > 2 sides (orthogonal). When comparing the experimental results under parallel and orthogonal irradiation conditions of 2 sides with 300 and 450 W, first degradation rate constants of TCE were similar, while production rate constants of hydrogen peroxide were more higher at parallel conditions compared to orthogonal conditions.

Sonolysis of Trichloroethylene in a Continuous Flow Reactor with the Multi Ultrasound Irradiation (연속식 다중 초음파 반응조에서 TCE의 초음파 분해)

  • Lee, Min-Ju;Oh, Je-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.6
    • /
    • pp.419-427
    • /
    • 2009
  • To test applicability for continuous flow treatment of ultrasound technology, sonolysis of TCE aqueous solution using 584 kHz multi irradiation reactor was performed under batch and continuous flow conditions. Under batch condition (3 and 4 sides irradiation, 600 W), first order degradation rate constant of TCE was higher under 4 sides than 3 sides irradiation conditions, while the generation of $H_2O_2$ and chloride was similar under both irradiation conditions. Under continuous flow condition with 4 sides irradiation, removal efficiencies of TCE in steady-state were decreased from 83 to 48% with increasing flow rate from 67 to 300 mL/min at 600 W, and were increased from 14 to 75% with increasing acoustic power from 100 to 600 W at 100 mL/min. Removal efficiency of TCE in groundwater was decreased 10% compared to in distilled water at 100 mL/min and 600 W.

A Study on the Disintegration of Sewage Sludge using Batch Ultrasonic Pretreatment (회분식 초음파 전처리를 이용한 하수슬러지의 분해에 관한 연구)

  • Ko, Hyun-Woong;Jung, Byung-Gil;Jung, Yon-Hwa;Kim, Hyeung-Seok;Jang, Seong-Ho;Sung, Nak-Chang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.4
    • /
    • pp.121-129
    • /
    • 2004
  • Anaerobic digestion is the most common process for sewage sludge stabilization and has benefits of VS reduction and biogas production. Many pretreatment methods have been studied to improve hydrolysis rate because the rate of sewage sludge degradation is slow in anaerobic digestion. This study mainly focused upon the effects on disintegration of sewage sludge by ultrasonic pretreatment according to the variation of acoustic density and duration of sonication time. In this study, acoustic density has been changed as follows : 33W/L, 70W/L, 88W/L, 139W/L in case of 40 kHz with the test time changes of 10min, 20min, 25min, 30min and 40min. In the comparison of $SCOD_{Cr}/TCOD_{Cr}$ variation for excess sludge and mixed sludge disintegration, the rates of $SCOD_{Cr}/TCOD_{Cr}$ have been increased in the condition of denser acoustic density and longer sonication time with acoustic frequency of 40kHz. The pH of the excess sewage sludge and mixed sewage sludge has been decreased in the condition of denser acoustic density and longer sonication time with acoustic frequency of 40kHz.

  • PDF

Improvement of Fouling in Membrane Separation Process for Leachate Treatment using Ultrasound(II) : Analysis of Membrane Materials, Solutes and Multi-ultrasonic Effect (초음파를 이용한 침출수 처리를 위한 막분리 공정의 막힘현상 개선(II) : 막의 재질, 용질과 복합초음파의 효과 분석)

  • Kim, Seok-Wan;Lim, Jae-Lim;Lee, Jun-Geol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.207-215
    • /
    • 2006
  • This study evaluated the effect of ultrasonic irradiation on reducing membrane fouling for the treatment of chemically treated leachate and biologically treated leachate. The experiments on improvement of membrane flux according to the membrane types(MF and UF) and membrane materials were performed with changing frequency(40 kHz and 120 kHz) and intensity(200 W and 400 W) of ultrasound in ultrasonic membrane separation apparatus which ultrasound can be periodically irradiated. Additionally, the effect of dual frequency ultrasound which 40 kHz md 120 kHz are irradiated simultaneously was evaluated. The improvement of membrane flux by periodical ultrasound irradiation was higher in microfiltration(MF) membrane than in ultrafiltration(UF) membrane. It was sustained more in the MF membrane of polyvinylidene fluoride(PVDF) than in that of polysulfon(PS). Ultrasonic improvement of membrane flux was different depending on the characteristics of target wastewater. It was sustainably maintained without reclogging using dual frequency ultrasound although the improvement of membrane flux was lower.

Observation of Acoustic Characteristic Change in bubble cloud by Ultrasonic Cavitation (초음파 캐비테이션에 의한 기포군에서의 음향특성 변화관찰)

  • Noh, Si-Cheol;Kim, Ju-Young;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.351-356
    • /
    • 2012
  • Ultrasonic cavitation is a physical phenomenon that generates and collapses microbubbles in media (mainly fluids) under conditions of strong ultrasonic irradiation. In this study, changes in the ultrasonic acoustic characteristics of bubble clouds in relation to ultrasonic irradiation were observed by the quantitative evaluation of cavitation yields. Concave-type single ultrasonic transducers with center frequencies of 500 kHz and 1.1 MHz were used to produce cavitation, and 2.25 MHz interference ultrasonic waves that would traverse any bubble clouds generated were used to analyze the cavitation. The parameters used for the evaluation of cavitation yields (changes in the center frequency, attenuation characteristics, and the propagation time of penetrating waves) were analyzed in relation to the cavitation-generating conditions (irradiation intensity, excitation signal, and center frequency). On the basis of these results, correlations between the changes in the center frequency and irradiation intensity were identified. Although the correlation coefficient was low, notable changes were observed in the center frequency under certain irradiation conditions. Attenuation trends in the interference ultrasonic waves showed high correlations with all the irradiation conditions, and it was noted that these trends were not affected by the forms of cavitation generated. No differences in the propagation time were observed among different irradiation conditions. These findings suggest that bubble yields can be quantitatively evaluated effectively by evaluating the diverse irradiation conditions and that such a quantitative evaluation could be used to study the basic cavitation phenomenon occurring in high-intensity ultrasonic wave treatment.

Application of Ultrasound for the Decomposition of Musty-Odorous Compounds in Water (수용액 중 Musty-Odorous Compound류의 분해에 따른 초음파의 응용)

  • 유영억;영전양웅;전전태소
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 1998
  • Musty-odorous compound (Geosmin, 2-Methylisobrneol) 수용액 중에 초음파 (200kHz, $6.0W/cm^{2}$)를 조사시켜 조사시간에 따른 농도 및 취기의 변화를 고찰했다. 초음파 조사에 의해 이 물질들은 빠르게 분해되었고 분해 형태는 농도에 대한 유사1차 반응을 나타내었다. 공기 포화 분위기에서 이들의 초기 분해속도는 각각 2.5 $10^{-3}{\;}Msec^{-1}$(2-MIB), 3.2 $10^{-3}{\;}Msec^{-1}$ (Geosmin)로 나타났다. 초음파 조사 시 포화가스 (Envelope gas)의 영향은 아르곤(Ar) 산소($O_{2}$) 공기(Air) 질소($N_{2}$) 순서로 순수한 아르곤(Ar) 분위기에서 musty-odorous compound 류의 분해가 가장 빠르게 진행되었고 그 분해생성물로 CO, $CO_{2}$ 그리고 HCOOH, $CH_{3}COOH$ 등의 저급 유기산류가 검출되었다. 또한 이들의 분해반응은 물의 초음파분해에 따라 생성된 hydroxylradical에 의한 radical반응, cavitation bubble내에서의 고온고압에 의한 열분해 및 직접연소반응으로 진행됨을 알 수 있었다.

  • PDF

Sonochemical Destruction of Aliphatic Aldehydes in an Aqueous Solution (수용액중 초음파조사에 의한 Aldehyde류의 초음파분해)

  • Yoo, Young-Eok;Howang, Kyu-Tak;Maeda, Yasuaki
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.4
    • /
    • pp.39-44
    • /
    • 1997
  • Propionaldehyde, n-Butyraldehyde, n-Valeraldehyde 수용액에 주파수 200 kHz, 출력 6.0 W/cm$^2$의 초음파조사후 그 분해반응에 관해 고찰했다. Aldehyde류는 초음파 조사에 의해 빠르게 분해되었고, 분해형태는 유사1차 반응을 나타내었다. 이들의 분해 속도는 Propionaldehyde

  • PDF

The Implementation of TMM test phantom for evaluating the thermal performance in High Intensity Focused Ultrasound system (강력 집속 초음파 시스템의 열적 성능 평가를 위한 팬텀 개발에 관한 기초연구)

  • Yu, Woo-Jin;Noh, Si-Cheol;Park, Moon-Kyu;Min, Hae-Ki;Park, Jae-Hyun;Choi, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.484-485
    • /
    • 2008
  • 초음파는 의학적 진단 및 치료의 목적으로 널리 사용되어 왔다. 일반적으로, 초음파 조사의 생물학적 무해성은 많은 연구를 통하여 보고되었으나, 최근 초음파 집속을 통한 강력 초음파의 사용에 대한 열적 안전성 평가가 중요한 요소로 대두되고 있다. 이에 본 연구에서는 강력 집속 초음파의 전달 에너지와 열적 분포를 측정하여 안전성 평가에 활용 가능한 초음파 열분포 팬텀을 제안하였다. 온도 분포 측정용 팬텀은 초음파 조직유사 팬텀 재료인 한천을 이용하였으며, 음향학적 특성의 유사성을 평가하였다. 온도 효과를 측정하기 위하여 $3{\times}3$의 형태로 온도 센서를 팬텀 내부에 배열하여 초음파 조사에 따른 온도 분포를 측정하였고 온도 측정을 위한 시스템을 개발하여, 초음파 가열 실험을 수행하였다. 본 연구에서 제안된 초음파 온도 분포 측정용 팬텀의 유용성을 확인하였으며, 온도 분포용 팬텀을 통한 강력 집속 초음파 장비의 열적 성능 평가에 적용 될 수 있을 것으로 사료되었다.

  • PDF