• Title/Summary/Keyword: 초음파 장비

Search Result 248, Processing Time 0.033 seconds

Usefulness about BSGI (Breast Specific Gamma Imaging) in Breast Cancer Patients (유방암 환자에서 Breast Specific Gamma Imaging (BSGI)의 유용성)

  • Cho, Yong-Gwi;Pyo, Seong-Jae;Kim, Bong-Su;Shin, Chea-Ho;Cho, Jin-Woo;Yeo, Ji-Yeon;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.92-101
    • /
    • 2009
  • Purpose: Scintimammography is one of the screening tests for the early diagnosis of breast cancer. It has been widely accepted as very useful in assessing masses that have not been detected in breast scanning. This method is highly sensitive and specific with respect to the diagnosis of primary and relapsing breast cancer. It has some difficulties, however, in detecting tumors sized 1 cm and below due to the radioactivity around the breast and the geometrical structure of the equipment. The recent introduction of high-resolution Breast-specific Gamma Imaging (BSGI) has made it possible to more accurately discriminate between malignant and benign tumors than with any other test method. Thus, the possibility of an unnecessary biopsy being performed has decreased. The purpose of this study was to examine the diagnostic capacity of mammography, breast sonography, and scintimammography, which are used for the early diagnosis of known breast cancer, and of BSGI, and to evaluate the skillfulness of radiologists. Materials and Methods: The 53 volunteers participants who had no clinical manifestation of breast cancer underwent the BSGI in February 2009. In the BSGI procedure, scanning images were obtained from the craniocaudal projection (CC) and the mediolateral Oblique projection (MLO), as well as from the additional $80{\times}80$-matrix-sized views at various angles in the Present Time method, 10 minutes after the 25 mCi $^{99m}Tc$-MIBI was injected. Results: The results of the BSGI showed that two participants had masses in their breast tissue. As the results of the diagnosis of four participants were not clear, they were retested and the results of the second test were negative. The results of the clinical screening test for breast cancer showed that the sensitivity of BSGI, scintimammography, mammography, and breast sonography was 86.5%, 77.8%, 85~90%, and 66.7%, respectively, and that their specificity was 92.4%, 84.2%, 20~42%, and 68%, respectively. Conclusion: The autodiagnosis and breast cancer screening test are needed for the early diagnosis of breast cancer. It was not easy, however, to accurately determine the presence of a mass in the breast using the existing breast cancer screening test. The patients with unclear test findings were made to undergo a histologic biopsy for a more accurate diagnosis. It is expected that the BSGI can provide useful information for the early diagnosis of breast cancer and of primary breast cancer, and will reduce the performance of unnecessary biopsies because of its higher sensitivity and specificity than existing breast cancer screening tests.

  • PDF

핵융합로용 플라즈마 대향부품 개발을 위해 제작된 텅스텐/FM강 HIP 접합 목업의 수명 평가 해석

  • Lee, Dong-Won;Sin, Gyu-In;Kim, Seok-Gwon;Jin, Hyeong-Gon;Lee, Eo-Hwak;Yun, Jae-Seong;Mun, Se-Yeon;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.452-452
    • /
    • 2014
  • 블랑켓 일차벽이나 디버터와 같은 핵융합로 플라즈마 대향부품은 플라즈마로부터 입사되는 중성자 및 입자들을 차폐하여 구조물을 보호하고, 발생열을 에너지로 변환하기 위해 냉각재를 활용한 열제거 기능을 담당한다. 특히, 고속중성자와 입사 열부하 및 여러 입자들로부터 블랑켓 및 내부 구조물을 보호하기 위해 차폐체와 구조물로 구성된다. 세계적으로 차폐체로서는 텅스텐 혹은 텅스텐 합금, 구조물용 재료로는 저방사화 Ferritic Martensitic (FM) 강이 유력한 후보재료로 개발, 연구 중에 있다. 국내에서는 국제핵융합로(ITER) 사업을 통해 고온등방가압(HIP, Hot Isostatic Pressing)을 이용한 이종금속간 접합기술과 한국형 저방사화 고온구조재료인 ARAA (Advanced Reduced Activation Alloy)가 개발되고 있으며, 이를 활용한 설계, 접합법 개발, 제작목업의 건전성 평가 등이 수행되고 있다. 한국원자력연구원에서는 핵융합 기초사업의 일환으로 전북대와 공동으로 수행 중인 건전성 평가체계 개발을 위해, 기 개발된 접합법을 활용한 $45mm(H){\times}45mm(W){\times}2mm(T)$의 W/FM강 목업을 제작한 바 있으며, 이를 국내 구축된 고열부하 시험 장비인 KoHLT-EB (Electron Beam)를 활용한 고열부하 인가 건전성 평가시험을 준비 중에 있다. 이종금속간 접합 특성은 기계적 평가를 위한 파괴시험을 통해 검증, 이를 활용한 목업이 제작되었으며, 제작된 목업에 대한 초음파를 이용한 접합면의 비파괴 검사를 통해 결함이 없음을 확인하였다. 최종적으로 실제 사용되는 핵융합 운전조건과 유사 혹은 가혹한 조건에서 고열부하를 인가하여, 그 건전성을 평가가 이루어질 것이다. 고열부하 시험을 위해서는 냉각조건, 인가 열부하, 수명평가를 통한 반복 고열부하 인가 횟수 등이 사전에 결정되어야 한다. 이를 위해 상업용 열수력, 구조해석 코드인 ANSYS-CFX와 -mechanical을 이용한 시험조건 모의 및 수명 평가가 수행되었다. 구축 장비의 냉각계통을 고려하여 냉각수의 온도 및 속도는 $25^{\circ}C$, 0.15 kg/sec로, 열부하는 0.5 및 $1.0MW/m^2$에 대해 모의를 수행하였다. 정상상태 시 텅스텐의 최대 온도는 각 열부하 조건에 따라 $285.3^{\circ}C$$546.8^{\circ}C$였으며, 이에 도달하는 시간을 구하기 위해 천이해석을 수행하였고, 이를 통해 30초에 최대온도 95 %이상의 정상상태 온도에 도달함을 확인하였다. 또한, 목업의 초기 온도에 도달하는 냉각시간도 동일한 천이해석을 통해 30초로 가능함을 확인하였고, 최종 시험 조건을 30초 가열, 30초 냉각으로 결정하였다. 결정된 반복 열부하 인가 조건에서 이종금속 접합체가 받는 다른 열팽창 정도에 따른 응력을 계산하여 목업의 수명을 도출하였고, 이를 시험해야 할 반복 횟수로 결정하였다. 각 열부하 조건에 따른 온도조건을 ANSYS-mechanical 코드를 활용하여 열팽창과 이에 따른 접합면의 응력분포로 계산하였다. 0.5 및 $1.0MW/m^2$에 대해, 목업이 받는 최대 응력은 334.3 MPa와 588.0 MPa 였으며, 이 때 텅스텐과 FM강이 받는 strain을 도출하여 물성치로 알려진 cycle to failure 값을 도출하였다. 열부하에서 예상되는 수명은 0.5 및 $1.0MW/m^2$에 대해, 100,000 사이클 이상과 2,655 사이클로 계산되었으며, 시간적 제약을 고려 최종 평가는 $1.0MW/m^2$에 대해, 3,000사이클 정도의 실험을 통해 그 수명까지 접합건전성이 유지되는 지 실험을 통해 평가할 예정이다.

  • PDF

Comparison of apical sealing ability of continuous wave of obturation technique using EndoTwinn and System B (EndoTwinn과 System B continuous wave of obturation units를 이용한 근단부 근관충전 효율비교)

  • Shin, Hyun-Ju;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.522-529
    • /
    • 2007
  • The purpose of this study was to compare the apical leakage of the root canal filled with the System B and the EndoTwinn(the combined application of heat and ultrasonic vibration). Sixty extracted premolars with straight root were cleaned and shaped to size 35. Group SB was obturated using System B and Group ET was filled with EndoTwinn. A size 35 of 0.06 tapered gutta-percha and Adseal were used and the plugger which could be introduced to 4 mm short of working length was selected in the obturation procedure. As the positive control, Group PC was not filled. In Group SB, ET and PC, all external surfaces of each tooth were coated with nail varnish leaving only 1 mm area around the apical foramen. In the negative control of Group NSB and Group NET, all of external tooth surface including apical foramen was coated with the nail varnish. The specimens were immersed in methylene blue dye solution for 2 days. Then the specimens were sectioned at each 1 mm from apex to 5 mm level. The final score of one specimen was given by summing up of the points at all levels. The dye leakage of Group ET was significantly less than that observed in Group SB (p < 0.05). And the frequency of gutta-percha pulling out from root canal when the plugger was removed was more often with the System B than with EndoTwinn but there was no significant difference.

The Effect of Increase in Length and Volume of Source in Radioactive Iodine Thyroid Uptake Rate (갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향)

  • Hwang, Dong Hun;Oh, Shin Hyun;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.70-75
    • /
    • 2017
  • Purpose Radioactive iodine thyroid uptake (RAIU) rate is an examination which determines and seeks about general functions of thyroid gland. The size of thyroid gland is normally different between each person, also patients having thyroid diseases have had a variety of size of thyroid gland compared with others. The purpose of this study will investigate about the counting rate which is effected by the geometric factors through the length and volume changes of the source in RAIU rate. Materials and Methods I-131 185 kBq ($5{\mu}Ci$) were placed in a cylindrical phantom of 0.5 cm, 1 cm, 1.5 cm, and 3 cm in diameter, respectively, and saline was added to gradually increase the length by 1 cm in the horizontal and vertical directions to give a change in volume. The source was measured 20 times for 20 seconds from a distance of 25 cm to $364.4keV{\pm}20%$ energy ROI with Captus 3000 thyroid uptake system (Capintec, NJ, USA). Results When the source was located in the transverse direction of the detector, the consequence of one-way ANOVA is that even though the length of source is increased each diameter, there is mostly no significant difference. When the source was located in the longitudinal direction and the counting rate of length 1 cm at all diameter is set to 100%, the average is 92.57% for length 2 cm, 86.1% for 3 cm, 80.69% for 4 cm, 74.82% for 5 cm, and 69.68% at 6 cm. Conclusion According to this study, it is expected that the gap of RAIU rate has been depended on the thickness of thyroid gland as well as the diameter of the beaker. We know that the change of the volume with the increase of the length of the source had less effect on the change of the counting rate. Thus, in order to reduce the error in the measurement of the counting rate with the thyroid uptake rate equipment, an accurate counting rate can be relatively measured if the counting rate which is measured is corrected by thickness or the distance between the thyroid and the thyroid uptake rate equipment is changed.

  • PDF

The Effects of Bilateral Chewing Exercise on Occlusion Force and Masseter Muscle Thickness in Community-Dwelling Elderly (양측저작 운동이 지역사회 거주 노인의 교합력과 깨물근에 미치는 효과)

  • Hong, Jun-Yong;Jung, Young-Jin;Kim, Min-Ji;Hwang, Se-Hyun;Park, Ji-Su;Lee, Gi-Hyoun;Kim, Tae-Hoon;Jung, Nam-Hae;Yoon, Tae-Hyung
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.10 no.1
    • /
    • pp.31-38
    • /
    • 2020
  • Objective : The purpose of this study is to investigate the effects of bilateral chewing exercise applied for 6 weeks on occlusion force and masseter muscle thickness in the elderly living in the community. Methods : This study recruited 25 community residents. All participants performed bilateral chewing exercise using equipment developed for the purpose of oral chewing exercise. The chewing exercise was divided into isometric and isotonic type and applied for about 20 minutes a day, five times a week for six weeks. For the evaluation, the masseter muscle thickness and the maximum occlusion force were measured three times at three week intervals using a portable ultrasound instrument and an occlusion force gauge. Results : As a result of the change in masseter muscle thickness, baseline, 3 weeks later, and 6 weeks later referred to 7.51±0.43, 7.63±0.44, and 7.83±0.46, respectively (F=3.819, p<.05). The post hoc test resulted in a significance between baseline and 6 weeks later (p=0.023). Similarly, as a result of the change in occlusion force, baseline, 3 weeks later, and 6 weeks later referred to 265±9.22, 268±9.57, and 271.59±10.16, respectively (F=3.031, p<.05). The post hoc test resulted in a significance between baseline and 6 weeks later (p=0.048). Conclusion : This study confirmed that bilateral chewing exercise was effective for increasing masseter muscle thickness and occlusion force in the elderly. Therefore, bilateral chewing exercise can be applied as a therapeutic exercise method for improving oral function.

The Usefulness of 3T-TOF MR angiography in Patients with Cerebral Infarction (뇌졸중 환자에서 3 Tesla 자기공명혈관조영술의 유용성)

  • Han, Je-Hee;Chung, Tae-Woong;Yoon, Woong;Jang, Nan-Kyu;Shin, Sang-Soo;Lim, Hyo-Soon;Song, Sang-Gook;Jeong, Yong-Yeon;Kang, Heoung-Keun;Seo, Jeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.94-100
    • /
    • 2005
  • Purpose : This study was designed to evaluate the usefulness of 3T-TOF MR angiography (3T-TOF MRA) compared with transcranial Doppler sonography (TCD) and conventional angiography (CA) in patients with suspected cerebral infarction. Materials and Methods : Fifty four patients with clinical symptoms of cerebral infarction were involved in this study, and had undergone 3T-TOF MRA and TCD, with CA in 11 patients. On the basis of divisions of the carotid artery, four groups were designated: group I, both vertebral arteries and basilar artery; group II, segment between 2 cm below bifurcation of common carotid artery and genu portion of internal carotid artery; group III, segment between petrous portion of internal carotid artery and bifurcation of anterior and middle cerebral artery; group IV, from bifurcation of anterior and middle cerebral artery to thier distal branches. Two radiologists retrospectively reviewed the vascular imaging and stenosis in 3T-TOF MRA, TCD, and CA. Results : A total of 432 arteries, 108 in each group, were available. The assessment of vascular imaging quality in 3T-TOF MRA is scored 2.98, 2.96, 2.91, 2.88 in 4 groups, respectively. Agreement among 3T-TOF MR angiography, TCD, and CA was high. Conclusion : 3T-TOF MR angiography may be useful method for the assessment of stenotic lesions of cranial vasculature in patients with cerebral infarction.

  • PDF

COMPARATIVE STUDY ON THE EARLY DETECTION OF ENAMEL LESIONS USING DIFOTI AND LASER FLUORESCENCE (Digital Imaging Fiber-Optic Trans-Illumination과 Laser Fluorescence를 이용한 법랑질 우식증의 조기 진단에 관한 비교 연구)

  • Maeng, Myoung-Ho;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.207-220
    • /
    • 2006
  • The newly developed equipments for the early detection of carious lesion are LFD (laser fluorescence device), Ultrasonic diagnostic system, CLSM(confocal laser scanning microscopy), QLF(quantitative light-induced fluorescence) and DIFOTI (digital imaging fiber-optic trans-illumination) system. In this study, DIFOTI system and LFD were used for the detection of early enamel caries. Twenty five primary teeth extracted from twenty one children at around the dentitional exchanging period were selected as samples. The results obtained from DIFOTI imaging and LFD measurement were compared with those of CLSM and comprehensive evaluations were made for the diagnostic capacity of each device. In vitro test, 40 sample teeth with their buccal & lingual surface formed by a window of $2{\times}3mm$ in diameter were immersed in artificial demineralizing solution for the period of 4, 8, 12 and 16 days. The results obtained from the experimental groups (DIFOTI, LFD) were compared to control group (CLSM) and we have reached to the following conclusions. 1. The sensitivity and specificity of DIFOTI system operated in oral environment was 88.2% and 76.9% respectively. 2. The sensitivity and specificity of LFD measured in oral environment was 76.5% and 69.2% respectively. 3, Regression analysis on the light transparent rate of DIFOTI showed its decrease according to the length of primary enamel decalcification performed in vitro(r=-0.96, p<0.05). 4. No statistically significant difference between LFT measurement and the length of in vitro decalcification was found in regression analysis (p>0.05). 5. The correlation coefficient of DIFOTI image transparent rate and the lesion depth of CLMS was -0.6988 (p<0.05), whereas no statistically significant difference was found for LFD measurement.

  • PDF

Development of deep learning network based low-quality image enhancement techniques for improving foreign object detection performance (이물 객체 탐지 성능 개선을 위한 딥러닝 네트워크 기반 저품질 영상 개선 기법 개발)

  • Ki-Yeol Eom;Byeong-Seok Min
    • Journal of Internet Computing and Services
    • /
    • v.25 no.1
    • /
    • pp.99-107
    • /
    • 2024
  • Along with economic growth and industrial development, there is an increasing demand for various electronic components and device production of semiconductor, SMT component, and electrical battery products. However, these products may contain foreign substances coming from manufacturing process such as iron, aluminum, plastic and so on, which could lead to serious problems or malfunctioning of the product, and fire on the electric vehicle. To solve these problems, it is necessary to determine whether there are foreign materials inside the product, and may tests have been done by means of non-destructive testing methodology such as ultrasound ot X-ray. Nevertheless, there are technical challenges and limitation in acquiring X-ray images and determining the presence of foreign materials. In particular Small-sized or low-density foreign materials may not be visible even when X-ray equipment is used, and noise can also make it difficult to detect foreign objects. Moreover, in order to meet the manufacturing speed requirement, the x-ray acquisition time should be reduced, which can result in the very low signal- to-noise ratio(SNR) lowering the foreign material detection accuracy. Therefore, in this paper, we propose a five-step approach to overcome the limitations of low resolution, which make it challenging to detect foreign substances. Firstly, global contrast of X-ray images are increased through histogram stretching methodology. Second, to strengthen the high frequency signal and local contrast, we applied local contrast enhancement technique. Third, to improve the edge clearness, Unsharp masking is applied to enhance edges, making objects more visible. Forth, the super-resolution method of the Residual Dense Block (RDB) is used for noise reduction and image enhancement. Last, the Yolov5 algorithm is employed to train and detect foreign objects after learning. Using the proposed method in this study, experimental results show an improvement of more than 10% in performance metrics such as precision compared to low-density images.