• Title/Summary/Keyword: 초음파 장비

Search Result 250, Processing Time 0.029 seconds

Antifouling Effect of an Ultrasonic System Operating at Different Frequencies (주파수 변동에 따른 초음파방오장비의 파울링제거효과)

  • Bae, Jin-Woo;Park, Guan-Sik;Ru, Myung-Lok;Park, Goun-Ha
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.609-616
    • /
    • 2019
  • When the fouling of a vessel occurs, its resistance at sea increases and there is a corresponding increase in fuel consumption. The maintenance cost of the vessel also increases because it is time-consuming to remove the fouling. To solve this problem and minimize environmental contamination of sea-water, there have been recent developments in anti-fouling paints as self-polishing copolymers that not include toxic elements such as tin. When these conventional techniques are applied to vessels, polishing is promoted during the operation whereby friction or vibration with seawater occurs. This leads to enhanced anti-fouling performance. However, when fouling is intensified such as during an anchorage, there is no flow of seawater and polishing is suppressed. This leads to a deterioration of the performance of anti-fouling. To solve these problems, we developed a system that induces vibration in a vessel during anchorage. As such, the deterioration of polishing due to insuf icient flow of seawater is inhibited. The reliability of the ultrasonic antifouling system was evaluated by calculating its repeatability. The removal efficiency of fouling of the proposed system was qualitatively evaluated using test specimens. The test revealed that the value of the coefficient of variation for the reproducibility of the frequency and amplitude was 0.2 % and 4.0 % on average. The degree of fouling of the specimens was the highest at 73.3 g in the No.5 sepcimen. Moreover, efficiency of fouling removal was 93.2 % on average compared to the specimens without the proposed system.

Development of Ultrasound Phantom for Volume Calibration (부피 측정을 위한 초음파 팬텀 개발)

  • Kim, Hye-Young;Lee, Ji-Hae;Lee, Kyung-Ja;Suh, Hyun-Suk;Lee, Re-Na
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.227-230
    • /
    • 2008
  • The purpose of this study was to design and construct an ultrasound phantom for volume calibration and evaluate the volume measurement accuracy of a 2 dimensional ultrasonic system. Ultrasound phantom was designed, constructed and tested. The phantom consisted of a background material and a target. The background was made by mixing agarose gel with water. A target, made with an elastic material, was filled with water to vary its volume and shape and inserted into background material. To evaluate accuracy of a 2 dimensional ultrasonic system (128XP, ACUSON), three different shapes of targets (a sphere, 2 ellipsoids and a triangular prism) were constructed. In case of ellipsoid shape, two targets, one with same size length and width (ellipsoid 1) and another with the length 2 times longer than width (ellipsoid 2) were examined. The target volumes of each shape were varied from 94cc to 450cc and measurement accuracy was examined. The volume difference between the real and measured target of the sphere shape ranged between 6.7 and 11%. For the ellipsoid targets, the differences ranged from 9.2 to 10.5% with ellipsoid 1 and 25.7% with ellipsoid 2. The volume difference of the triangular prism target ranged between 20.8 and 35%. An easy and simple method of constructing an ultrasound phantom was introduced and it was possible to check the volume measurement accuracy of an ultrasound system.

  • PDF

A Study on the Efficiency Evaluation of Ultrasound Therapy Using Varicose Vein Simulated Tissue Phantom and Tissue Equivalent Phantom (하지정맥류 모사 생체조직 팬텀과 조직등가 팬텀을 이용한 초음파 치료효과 평가에 관한 연구)

  • Kim, Ju-Young;Jung, Tae-Woong;Shin, Kyoung-Won;Noh, Si-Cheol;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.427-433
    • /
    • 2018
  • Because of the expectation of the non-invasive treatment effect, Various studies on the treatment of varicose veins using focused ultrasound are reported. In this study, the bio-tissue phantom and tissue equivalent phantom that can be applied to estimation of ultrasonic varicose veins treatment effect. Each phantom was evaluated for its usefulness by evaluating the acoustic characteristics and the shrinkage rate according to the ultrasonic irradiation. A multi-layer structure phantom with three layers of skin, fat, and muscle was constructed considering the structure of the tissue where the varicose veins occurred. The materials constituting each layer were made to have characteristics similar to human body. In addition, the multi-layered phantoms with blood vessel mimic tube, with bovine blood vessel, and with animal tissue were fabricated. The degree of shrinkage of blood vessel mimic material and vascular tissue according to ultrasonic irradiation was evaluated using B-mode image. As the results of this study, it was thought that the proposed phantom could be used effectively in the evaluation of ultrasonic varicose veins treatment. In addition, it is thought that these phantoms could be applied to the development of varicose vein treatment device using the focused ultrasound and the verification of the therapeutic effect.

Comparison of Utrasonic and Vibration Diagnostic Techniques for the Inspection of Pipes in CVD System (화학증착 시스템에서의 파이프내 오염입자 관찰을 위한 초음파 및 진동 진단법의 비교연구)

  • Yun Ju-Young;Seong Dae-Jin;Shin Yong-Hyoen;Lee Ji-Hun;Moon Doo-Kyung;Kang Sang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.421-426
    • /
    • 2006
  • In examining particulate deposits in the pipes of a chemical vapor deposition (CVD) system, vibration diagnostics is compared and studied against ultrasonic diagnostics, The latter method involves pulsing the outer wall of pipes with an ultrasonic sensor and analyzing the resulting echo to observe particulate deposits inside pipes. Vibration diagnostics examines the existence of particulate deposits by analyzing the difference in the frequencies generated when a vibrator is adhered to the outer wall of pipes. With ultrasonic diagnostics, good test results were obtained only when particulate deposits were attached to the inner wall of the pipes, After some time, however, particulate deposits were not detected properly, as the ultrasonic wave failed to cross the fine gaps created between the inner wall of the pipe and the deposits. The ultrasonic wave bounced back because of the dried particulate deposits on the wall. Thus, it has been proven that the ultrasonic diagnostics is not an appropriate means of examining the particulate deposits in a vacuum, On the other hand, vibration diagnostics succeeded in detecting the particulate deposits regardless of the lapsed time. In conclusion, the vibration diagnostics is being expected as the effective method in monitoring the particulate deposits inside pipes in the CVD system where the desired behavior is reduced frequency along with the particulate deposits in comparison to the case where the pipe is clean.

A New Design of the Interrogating Waves for Medical Ultrasonic Imaging Based on Wavelets and Subband Filter Banks: A Simulation Study (의료용 초음파 영상시스템을 위한 Wavelet 과 Subband Filter Bank 에 기반한 새로운 탐침 파형의 설계: A Simulation Study)

  • Yang Yoon Seok
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.431-438
    • /
    • 2004
  • Medical ultrasonic imaging is a useful imaging facility known to be most safe and easy. It enables physicians to observe the inside structures of the bodies, blood flow, and motions of internal organs. Some physical properties of biologic tissues can also be estimated from backscattered sounds. However, the ultrasonic pulses interrogating the living organisms leave their footprints in the returning signals during imaging. Some significant details are buried in the footprints and their overlaps from adjacent particles. These distortions also decrease the quality of the images. Many research efforts have been made to enhance the image quality and to recover the acoustic information in various ways. In this study, a new interrogation method based on the wavelet and subband filter bank is proposed. It adopts the subband wavelet filters satisfying the perfect-reconstruction (PR) conditions as the interrogating pulses to restore the details useful in tissue characterization and to enhance the image quality. The proposed method was applied to two types of simulations of ultrasonic imaging. The results showed its ability to restore the detailsin the simulated interrogation of biologic tissues, and verified the improved image quality in the simulated imaging of general ultrasonic phantom compared with the conventional method.

Usefulness of X-ray Guided Biopsy and Ultrasound Guided Biopsy in Breast Microcalcification Biopsy (유방 미세석회화 조직검사에서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 유용성)

  • Choi, Miseon;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • Social interest in breast cancer has increased. The most basic exams for diagnosis include breast X-ray and breast ultrasound. In particular, breast microcalcification requires histological diagnosis, and breast microcalcification biopsy is commonly performed. Therefore, this study aimed to analyze and assess X-ray guided biopsy (needle localized open biopsy) and ultrasound guided biopsy (sono guided core needle biopsy), which are basics in diagnosis of microcalcification. Targeting 241 cases in which magnification mammography was performed for patients who visited the hospital due to breast microcalcification, age distribution and the location of lesions were analyzed in X-ray guided biopsy and ultrasound guided biopsy. By classifying exams performed after magnification mammography, the frequencies of X-ray guided biopsy and ultrasound guided biopsy were analyzed, and malignant and benign results were confirmed. The results showed that 64 cases(26.6%) were X-ray guided biopsy, which was 5.4 times higher than 12 cases(4.9%) of ultrasound guided biopsy. Due to development of ultrasound equipments, stereotactic vacuum-assisted biopsy, etc. the methods of histological diagnosis of microcalcification have become diverse, but when considering characteristics and limitations of each exam, X-ray guided biopsy is thought to be most accurate and useful.

Design and manufacture of supersonic waves system that there is no invasion that there is no stimulation of embedded base for crush bone fracture patient's treatment (II) (파쇄 골절환자의 치료를 위한 임베디드 기반의 무자극, 무침습 초음파 시스템의 설계 및 제작(II))

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.5
    • /
    • pp.583-590
    • /
    • 2006
  • BT technology, medical treatment engineering technology is offering important role and grow by creative technology. Specially, bone fracture treatment can achieve very important role in research of bone, physiology and dynamics of bone is very useful patient's diagnostic and treatment in presence at a sickbed. <중략>Furthermore embedded base of in administration aspect as well as if supersonic waves curer is treatment innocuously and without invasion very efficient tell. If apply supersonic waves in bone fracture treatment, can reduce curer about 40%. Operation frequency through bone fracture treatment supersonic waves curer of embedded base designs and manufactured 1m Hz, 1.2mHz, 1.3mHz, 1.4mHz, supersonic waves origination that have 1.5mHz's tranducer, and embodied protocol in PDA base in this research, and did so that is interfaced to general PC. If is using but supplement research water that see clinically by diagnosis in city, is seen to become convenient medical treatment assistance mounting to bone fracture patient's treatment and courtesy call. Specially, tried to approach basic form after modeling processing if may be applied variously to physiotherapy, orthopaedics patient who gouge late, and study standardization special quality little more.

  • PDF

Experiments on the Detection of Delamination in FRP Reinforced Concrete (탄소섬유 보강 콘크리트의 박리 탐사 실험)

  • Rhim, Hong-Chul;Jung, Hang-Chul;Woo, Sang-Kyun;Song, Young-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.3-9
    • /
    • 2007
  • With a growing concern about the state of infrastructure worldwide, the demand for the development of reliable nondestructive testing techniques (NDT) is ever increasing. Among possible NDT techniques, microwave method is proven to be effective in fast and non-contact inspection of concrete structures and inclusions inside concrete. It is also found that the microwave method has a potential in detecting the delamination between fiber reinforced polymers (FRP) plate and concrete. On the other hand, ultrasonic method can be another way to find the delamination. In this paper, the research work needed for the development of a reliable microwave method and ultrasonic method is studied in the measurements of concrete specimens reinforced with FRP. Concrete specimens are made with FRP and artificial delamination inside. A microwave measurement system with hom antennas with high center frequency and broad frequency bandwidth are used to image inside concrete specimens for the detection of debonding between concrete and FRP. Also, ultrasonic method is used for the same condition. Both results are compared with each other.

Automatic Noncontact Ultrasonic Inspection Technique (비접촉식 초음파탐상방법 자동화 기술)

  • Kim, Y.G.;Ahn, B.Y.;Lee, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.4
    • /
    • pp.25-31
    • /
    • 1994
  • A system for EMAT, which generates ultrasound by electro-magnectic forces and performs nondestructive testing in noncontact, was established. By linking it with a 3 axis scanning system and a data acquisition and processing system the automation of EMAT testing was attempted. A EMAT sensor was fabricated and the directivity pattern of it was measured. To be suitable automation, it has a transmitter and a receiver in one case and the main beam direction of it can be controlled by the frequency of driving signal. A program which controls the EMAT system, the 3 axis scanner and the data acquisition and processing system was developed. It also processes acquired data and displays the processing results. IBM-PC/AT compatible PC was used as main controller and the stratage of the program is emulation of real devices on the PC monitor. To provide the performance of the established EMAT system, two aluminium blocks containing artificial flaws and a welded aluminium block were tested. The result of the tests were satisfactory.

  • PDF

Round Robin Test for Performance Demonstration System of Ultrasonic Examination Personnel (초음파검사자 기량검증 체제를 위한 다자비교시험)

  • Yoon, Byung-Sik;Yang, Seung-Han;Kim, Yong-Ho;Kim, Yong-Sik;Yang, Dong-Soon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.378-383
    • /
    • 2004
  • The Korean Performance Demonstration(KPD) System for the ultrasonic testing personnel, equipments and procedures applicable to the Class 1 and 2 piping examination for nuclear power plant in Korea has been established. A round robin test was conducted in order to compare the examination results by the method of Performance Demonstration(PD) with the traditional dB-drop method. The round robin test shows that the reliability of the PD method is better than that of the dB-drop method. As a result, adoption of the PD method to the in-service inspection of the nuclear power plants will improve the reliability of the ultrasonic test results.