• Title/Summary/Keyword: 초음파 압력

Search Result 219, Processing Time 0.028 seconds

The principle and a prototype system for burning rate measurement of solid propellants using ultrasound (초음파를 이용한 고체추진제 연소속도의 측정원리 및 시범시스템 개발)

  • Song Sung-Jin;Jeon Jin-Hong;Kim Hak-Joon;Kim In-Chul;Ryoo Baek-Neung;Yoo Ji-Chang;Jung Jung-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.259-265
    • /
    • 2005
  • To measure burning rate of solid propellants using ultrasonic technique, a special closed bomb and an ultrasonic and pressure measurement system are fabricated. During pressurization tests and burning tests on propellants, ultrasonic and pressure signal are acquired in realtime fashion by this system. Based on acquired signals, analysis programs using two different algorithm which can measure burning rates corresponding to pressures are compared. One algorithm is to correct sound velocity variation of propellants and solid couplant, another one is only to correct sound velocity variation of propellants. And accuracies of homing rates measured through these algorithms are calculated through comparison with homing rates measured using strand burner method.

  • PDF

The Principle and a Prototype System for Burning Rate Measurement of Solid Propellants Using Ultrasound (초음파를 이용한 고체추진제 연소속도 측정원리 및 시범시스템 개발)

  • Song, Sung-Jin;Jeon, Jin-Hong;Kim, Hak-Joon;Oh, Hyun-Taek;Kim, In-Chul;Yoo, Ji-Chang;Jung, Jung-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.4
    • /
    • pp.61-68
    • /
    • 2006
  • To measure burning rate of solid propellants using ultrasound, a special closed bomb and an ultrasonic and pressure measurement system are fabricated. During pressurization tests and homing tests on propellants, ultrasonic and pressure signal are acquired in real time fashion by this system. Based on acquired signals, analysis programs using two different algorithm which can measure burning rates corresponding to pressures are compared. One algorithm is to correct sound velocity variation of propellants and solid couplant, another one is only to correct sound velocity variation of propellants. And accuracies of homing rates measured through these algorithms are calculated through comparison with the burning rates measured using strand burner method.

Evaluation of fracture Appearance Transition Temperature to Pressure Vessel by Ultrasonics (초음파에 의한 압력용기의 연취성천이온도 평가)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.373-380
    • /
    • 2000
  • It is useful to use NDE methods to assess the mechanical properties of materials since destructive methods are time-consuming and usually require cutting of sample from the material/component. In the present research, ultrasonic characteristics have been utilized to evaluate changes of mechanical properties due to heat treatment temperature and condition. The attenuation coefficient of ultrasonic wave increased as the heat treatment temperature because the grain size increased in size as the temperature. The attenuation coefficient decreased as the heat treatment has been progressed (quenched, tempered, PWHT). In the case of ultrasonic velocity measurement, velocity difference between quenched and tempered/PWHT was 40 m/s. There was a good relationship between the attenuation coefficient and the toughness. The relationship can be used for the nondestructive evaluation of the forged reactor vessels. Moreover, the method may be effectively used in the field application.

  • PDF

Preparation of Nano-liposome by Sonication and Pressure (초음파와 압력을 이용한 나노 리포솜의 제조)

  • Lee, Jung-Min;Cho, Yong-Jin;Park, Dong-Joon;Ko, Sung-Ho;Lee, Seung-Cheol
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.1
    • /
    • pp.115-117
    • /
    • 2008
  • Liposomes are artificial membranes prepared by phospholipid. In this study, liposomes were prepared by dehydration-rehydration method, and then nano-sized by sonication and pressure. The sizes of the prepared multilamellar vesicles (MLV) were greater than 10 μm. Sonication with a tip-type sonifier or pressurization with a French press on MLV were carried out to reduce size. Sonication with an output of 112.5 W for 10 min on MLV resulted in sizes less than 450 nm. French press with 6,000 psi of pressure was able to manufacture liposomes of approximately 100 nm uniformly. Also, the sonication or pressure clarified the color of the liposome solutions. The results indicate that sonication and pressure via French press can be applied to obtain nano-sized liposomes.

Synergistic Effect of Oxygen Pressure and Sonophoresis for Skin Permeability (산소 압력과 초음파를 이용한 피부투과도 증대에 관한 연구)

  • 차민석;이철규;윤영로;이원수
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.189-196
    • /
    • 2002
  • Transdermal drug delivery offers an alternative method to the conventional oral and injection delivery method. Its advantages include its ability to deliver drugs directly into systemic circulation. However, there have been restrictions in its application to deliver drugs because of the skin's barrier function. In this study, we try to combine a Sonophoresis and oxygen Pressure method in order to increase the Permeability of the skin. we used water as the compound and by utilizing the skin impedance method. we measured the hydration Permeability of skin Ultrasound was applied using a sonicator(Solcare-U1000. Solco, Korea) operating at a frequency of 1MHz. oxygen Pressure was applied using a compressor(Oxyjet-Pointer, Nora Bode. Germany) operating at a pressure of 2Bar/cm2. Experiment was performed in vivo for 42 People. We divided the subjects into four smaller groups. A different transdermal drug delivery method was applied for each group on the back of their hand. We measured the skin impedance variations on the hand. during a 20-minute time Period. The control group did not show any significant increase or variation of skin impedance to water. In comparison to the control group(Passive diffusion) the hydration Permeability of the ultrasound group and the oxygen Pressure group was approximately 25 and 30 times higher consecutively. Futhermore, the hydration permeability of the combination of ultrasound and oxygen Pressure group was about 70-fold higher in comparison to the control group(passive diffusion) . The results reveal that a combination of ultrasound and oxygen Pressure will significantly enhance transdermal water transport compared when only one of them is used.

Measurement of High Temperature Anisotropic Elastic Constants of Zr-2.5Nb Pressure Tube Materials by Resonant Ultrasound Spectroscopy (초음파공명분광법에 의한 Zr-2.5Nb 압력관 재료의 고온 이방성 탄성계수 측정)

  • Cheong, Yong-Moo;Kim, Sung-Soo;Kim, Young-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.140-148
    • /
    • 2002
  • Anisotropic elastic constants of Zr-2.5Nb pressure tube materials were determined by a high temperature resonant ultrasound spectroscopy (RUS). The resonant frequencies were measured using alumina wave-guides and wide band ultrasonic transducers in a small furnace. The rectangular parallelepiped specimens were fabricated along with the axial, radial and circumferential direction of the pressure tube. A nine elastic stiffness tensor for orthotropic symmetry was determined in the range of room temperature ${\sim}500^{\circ}C$. As the temperature increases, the elastic constant tensor, cij gradually decreases. Higher elastic constants along the transverse direction compared to those along the axial or radial direction are similar to the case of Young's modulus or shear modulus. A crossing of shear elastic constants along axial direction and radial direction was observed near $150^{\circ}C$. This fact corresponds to the crossing of c44 and c66 of single crystal zirconium.

A Study on Hemodynamic Characteristics at the Occlusion on Radial Artery (Radial artery occlusion 시 혈류역학적 특성변화)

  • Lee, Yu-Jung;Lee, Jeon;Ryu, Hyun-Hee;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1989-1990
    • /
    • 2008
  • 한의학에서 맥진은 한의사가 손가락으로 환자의 손목의 요골동맥을 짚어 맥박이 손가락에 닿는 느낌에 근거하여 병세를 감별하는 진찰방법으로 인체의 건강상태를 살피고, 정상인의 평맥(平脈)으로부터 환자의 병맥(病脈)을 분석하는 진단법이다. 손목에 있는 요골 경상돌기(styloid preocess) 부근의 볼록한 지점을 고골(高骨)이라하는데 이 돌기를 기준으로 맥이 느껴지는 위치를 검지, 중지, 약지를 이용해 진맥위치를 잡는다. 맥진 시 한의사는 맥진위치에 압력을 서서히 가하면서 손끝에 느껴지는 감각을 이용해 진단한다. 이 과정에서 맥진위치 요골동맥의 혈관이 서서히 occlusion 된다. 본 논문에서는 맥진과정 시 요골동맥의 혈류역학적인 변화를 초음파를 이용해 분석해보고자 한다. 건강한 남자 피험자(34세)를 대상으로 초음파 장비(Voluson 730Pro, GE Medical, U.S.)를 이용해 맥진 위치의 혈관특성을 관찰한다. 혈압계를 이용해 혈관에 압력을 0에서 130mmHg까지 10mmHg씩 단계별로 가압한 후 초음파를 측정한다. 그 결과, 요골동맥에 압력을 가할수록 혈류속도가 서서히 감소함을 알 수 있었으며, 회귀식을 분석할 수 있었다(y = -0.3509x +44.323, $R^2$ = 0.9547). 또한, 가압 단계를 0$\sim$10mmHg, 20$\sim$40mmHg, 50$\sim$70mmHg, 80$\sim$100mmHg 110$\sim$130mmHg으로 가압단계를 나누어 보면, 각 단계별로는 42.32cm/sec, 33.08cm/sec, 24.8cm/sec, 14.3cm/sec, 0cm/sec로 혈류속도가 변화를 보였다. 각 단계별로 혈류속도가 평균 10.58cm/sec의 차이를 보임을 알 수 있다. 본 연구를 통해 가압력에 대한 맥진위치의 혈류변화를 관찰하였다. 그러나 직접 맥진위치를 가압하면서 초음파를 통해 혈류속도를 측정할 수 있는 방법이 없어, 맥진 위치 바로 위쪽을 가압하고 초음파 측정을 하였다. 직접 혈관을 가압하고 그때의 혈류속도를 측정하면 보다 정확히 맥진시의 혈류역학적 특성을 분석할 수 있을 것으로 판단된다. 장비의 고안을 통해 다음 연구에서는 직접적인 가압 후 혈슈속도를 측정해 봄으로써 본 결과와 비교 분석해 보고자 한다.

  • PDF

The Study of Pressure Vacuum Measurement Techniques Using Ultrasonic Acoustic Impedance Transducers (초음파 음향임피던스 변환기를 이용한 저압 저진공 측정기술 연구)

  • Hong, S.S.;Shin, Y.H.;Cho, S.H.;Ahn, B.Y.;Lim, J.Y.;Choi, I.M.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.5
    • /
    • pp.319-325
    • /
    • 2010
  • Pressure vacuum measurement technique using acoustic impedance change of ultrasonic transducers was studied. The sensor has been setup using two air-coupled ultrasonic transducers, one as a transmitter and the other as a receiver, and put it into vacuum chamber and measured pressure versus ultrasonic amplitude. The result confirms that the standard deviations of four repeat measurements were from 0.0093 to 0.3325 at pressure 6.66 kPa to 202.65 kPa(about two atmosphere), and the relative percents were 0.018% and 0.164% at pressure 133.32 kPa and 202.65 kPa, respectively.

Development of Ultrasonic Inspection System and Application to Overlay Weld Flaw Detection (초음파 자동 검사시스템의 개발과 오버레이 용접부의 결함검사)

  • Nam, Young-Hyun;Seong, Un-Hak
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.562-567
    • /
    • 2000
  • Many pressure vessels for power and industrial plant are fabricated from low alloy carbon steels. The inner sides of pressure vessels are commonly weld-cladded with austenitic stainless steels to minimize problems of corrosive attack. Disbonding cracks are often detected at the transition region of welding interlayer, which is serious problem to reliability of pressure vessels. We have developed C-scan system to high speed inspection of overlay weld using DSP(digital signal processor). This system consists of signal processing parts (oscilloscope, pulser/receiver, digitizer, DSP), scanner, program and position controller. The developed system has been applied to a practical ultrasonic testing in overlay weld, and demonstrated high speed with precision

  • PDF