Evaluation of the Corroded Pipe by Time-Frequency Analysis (시간-주파수 해석에 의한 부식된 배관의 평가)

  • Ahn, S.H.;Kim, J.W.;Do, J.Y.;Nam, K.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.89-92
    • /
    • 2006
  • In this study, the pressure vessel piping with corrosion used during long term were investigated from the time-frequency analysis method. The damage of piping could be evaluated the attenuation factor by ultrasonic parameters such as center frequency and echo waveform. Based on NDE analysis by time-frequency analysis method, it should also be possible to evaluate from various damages and defects in piping members.

  • PDF

Operation of the Pangyo experimental catchment to assess the hydrological effect by new town development (신도시 개발에 따른 수문학적 영향 평가를 위한 판교시험유역의 운영)

  • Kim, Chul-Gyum;Kim, Hyeon-Jun;Jang, Cheol-Hee;Noh, Seong-Jin;Park, Chang-Eon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.889-893
    • /
    • 2007
  • 본 연구에서는 도시화로 인하여 대규모 토지이용 변화가 예상되는 신도시 개발예정지구인 판교 운중천유역을 시험유역으로 선정하고, 2004년 8월부터 수문관측망을 구성하여 장기적인 수문모니터링을 수행하고 있으며, 2007년 현재 시험유역내 4개의 하천수위관측소 (판교교, 삼평교, 매송2교, 내동교), 3개의 우량관측소(매송2교, 내동교, 운중저수지), 그리고 저수지 및 용수로 수위관측소 (운중저수지) 등 총 8개 지점에 대하여 초음파 수위계 5개, 압력식 수위계 5개, 전도형 강우계 3개가 설치되어 운영중이다. 모든 자료는 10분 단위로 관측되고 있으며, 무선인터넷시스템을 통하여 모니터링 서버에 주기적으로 전송되어, 현장의 계측상황 및 장비에 대한 제어, 자료 분석 및 저장이 가능하도록 되어 있다. 관측된 모든 자료는 홈페이지(http://218.148.68.59/kict)를 통해 실시간으로 제공되고 있다.

  • PDF

A Study on Ppray Ignition Phenomena Using Shock Tube Combustion System Design (충격파관 시스템설계에 의한 분무의 착화현상 연구)

  • ;水谷幸夫
    • Journal of Energy Engineering
    • /
    • v.3 no.1
    • /
    • pp.54-61
    • /
    • 1994
  • 계단형태의 고온발생장치로서, 고온의 흐름을 형성하고 난류유동이 없이 일정한 혼합기류를 만들 수 있는 2단격막구조 충격파관 장치를 이용하여, 혼합을 동반하지 않는 분무의 착화과정에 관한 실험을 수행하였다. 본 실험에서는 충격파관 속에 하향으로 설치된 초음파 분무기에 의해 자유낙하 상태에 있는 예혼합 분무주를 만들어서 반사충격파에 의해 순간적으로 단열압축시켜서 착화 현상을 관찰하였다. 고온영역과 저온영역에서 얻어진 활성화에너지는 큰 차이가 나며 본 연구에서 얻은 착화지연의 실험결과는 통상의 분무착화 실험인 전기로법, 급속압축기법, 고온기류속에 연료를 분사하는 방법과 다른 현상을 보였다. 그 대표적인 결과에 대한 예로는 착화지연에 대한 압력 의존성과 연료분사율의 영향이 일반적인 분무의 결과에 비해 적게 나타났다.

  • PDF

Implementation of the parking management system based on PLC (PLC기반의 주차장 관리시스템 구현)

  • Ryu, Dong-Wan;Kim, Sun-Hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.497-499
    • /
    • 2015
  • According to the rapid progress of the altitude information society and various sensor technologies, The role of information and communication systems became important during social activities. In this paper, It is measured access and availability alongside parking and availability using an ultrasonic sensor and a pressure sensor. And the measuring data is sent to the controller by using the PLC (Power Line Communication). And it is implementing the parking management system made secure by controlling the LED and LCD with the received data.

  • PDF

A Study on a Quantitative Measurement of Contact Pressure Between two Rough Flat SurFaces by Means of Ultrasonic Waves. (초음파를 이용한 이체 평면접촉부의 정량적인 접촉압력 측정에 관한 연구)

  • 김경모;정인성
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.3
    • /
    • pp.8-26
    • /
    • 1990
  • It is important to have exact information about the contact pressure distribution in the design of connected parts of machines and structures. In previous works, stress analyses on a two body contact problem have been carried out in large numbers. Besides, the measurement of contact stress is important to confirm the adequateness of the theoretical analysis, to verify appropriateness of Hertzian contact theory and to know the practical pressure distribution, but an excellent measuring method con't be found at present. Therefore, a quantitative measurement of contact pressure by means of ultrasonic waves using a normal probe and an angle has been proposed to measure the contact pressure distribution between two rough flat surfaces. At first, in a new proposed calibration method, the relation between mean contact pressure and sound pressure of reflected waves is obtained by using calibration blocks with various surface roughnesses made of the same material as the rectangular section beams And then, this experimental results are compared with the analytical ones, and the utility of this method is discussed.

  • PDF

Construction of the Intelligence Stress Predictor for Compression Strength Evaluation (압축강도 평가를 위한 지능형 응력예측기 구축)

  • 박원규;우영환;이종구;윤인식
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.95-101
    • /
    • 2001
  • This work is concerned with construction of the intelligence stress predictor far compression strength evaluation using neural network-ultrasonic waves. The contact pressure in jointed plates was measured by using ultrasonic technique. Neural network is used to evaluate and predict contact pressure from the results of the calibration curves. The organized neural system was leaned with the accuracy of 99%, as a result of learning the ultrasonic echo ratio to the contact pressure measurement between SM45C and STS410 materials. And it could be evaluated and predicted with the accuracy of 90% in the evaluation of ultrasonic echo ratio difference in the same surface roughness and contact pressure, and 85% in the prediction of virtual ultrasonic echo ratio. Thus the proposed stress predictor is very useful for the evaluation and prediction of the contact pressure between SM45C and STS410 materials.

  • PDF

가슴 착용형 보행 재활로봇의 개발

  • Kim, Hyeon;Gwon, Jeong-Gwan;Song, Sang-Yeong;Gang, Seok-Il;Kim, Jeong-Yeop
    • ICROS
    • /
    • v.21 no.2
    • /
    • pp.25-30
    • /
    • 2015
  • 본 논문에서는 간병인의 도움없이 자가 보행 재활에 효과적으로 사용될 수 있는 새로운 개념의 가슴 착용형 로봇을 개발하였다. 개발된 로봇의 특징은 크게 세 가지로 나뉜다. 첫째, 구조적 특징으로써, 하박에 착용하는 기존 지팡이 타입의 엘보 크러치와 달리 개발된 로봇은 가슴에 착용되어 착용자의 두 팔을 자유롭게 하는 동시에 팔의 부담을 제거하여 준다. 둘째는 구동 알고리즘의 특징으로써, 가슴부에 부착된 압력센서로부터 사용자의 보행의도를 자동적으로 인식하여 로봇의 다리를 이동시킨다. 또한 착용자의 안전을 위해 초음파 센서를 이용하여 착용자 전방에 장애물이 나타날 시 보행을 멈추고 경고음을 발생시킨다. 마지막으로, 스카치요크 메커니즘을 사용하여 지지다리의 상승과 하강 시 지면 반발력으로 인하여지지 발 상/하강 모터에 과도한 토크가 부과되지 않도록 하였다. 이러한 세 가지 특징으로부터 개발된 로봇이 자가 보행 재활에 효과적으로 사용될 수 있음을 실험적으로 보였으며, EMG (Electromyography) 센서를 이용하여 근력 보조 성능을 정량적으로 검증하였다.

  • PDF

Smart Chair system using Raspberry Pi (라즈베리파이를 활용한 스마트 의자)

  • Song, Gil-Ho;Na, Hyun-Ju;Park, Jung Hyun;Oh, Jae-Gon;Kim, Do-Hee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.10a
    • /
    • pp.295-298
    • /
    • 2019
  • 본 논문은 기존의 수동으로 높이 조절만 가능한 단순 의자를 탈피하여 자라나는 아이의 신장과 체형에 맞게 의자 높이를 자동으로 조절해주는 스마트 의자를 제안한다. 본 논문의 주요 특징은 다음과 같다. 첫째, 초음파센서와 무게센서를 사용하여 아이의 신장과 체중을 측정함으로써 신체에 맞게 자동으로 의자의 각도와 높낮이를 조절해준다. 둘째, 센서를 통해 실시간으로 데이터를 수집하여 App 화면에 건강 상태를 보여주고 아이 등급표와 비교하여 아이의 성장률을 가시적으로 보여준다. 셋째, 압력 센서를 이용하여 아이의 자세 상태를 보여주고 App 알림과 데이터 분석으로 아이의 자세 교정에 도움을 준다. 넷째, 신호를 전달하면 지정된 자리로 의자가 자동으로 이동하는 기능을 제공한다. 제안된 시스템은 IoT 기술을 접목함으로써 성장이 빠른 영유아를 키우는 가정을 대상으로 의자 교체에 필요한 비용 절감 효과와 바쁜 현대인들을 위해 아이의 건강관리를 보다 효율적으로 돕는 것을 목표로 한다.

CT Diagnosis of Paradoxical Embolism via a Patent Foramen Ovale in a Patient with a Pulmonary Embolism and Prominent Eustachian Valve (난원공개존증과 거대 유스타기오밸브를 가진 환자에서 기이색전증의 CT 진단)

  • Min Ji Son;Seung Min Yoo;Charles S White
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.435-439
    • /
    • 2021
  • While there is a high prevalence of patent foramen ovale in adults, paradoxical embolism via a patent foramen ovale is rare. Previous echocardiographic studies indicated that paradoxical embolism might only occur in patients with high-risk features of patent foramen ovale (i.e., large defect size, presence of a Eustachian valve, and high right atrial pressure). Here, we present a case of patent foramen ovale with high-risk CT features for paradoxical embolism.

Non-Destructive Testing of Damaged Thermoplastic Pipes Electrofusion Joints Using Phased Array Ultrasonic (위상배열초음파를 이용한 손상된 열가소성 플라스틱배관 전기융착부 비파괴검사)

  • Kil, Seong-Hee;Kim, Byung-Duk;Kwon, Jeong-Rock;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.64-68
    • /
    • 2013
  • Non destructive testing(NDT) methods of electrofusion(EF) joints of thermoplastics pipes are required for fusion joint safety and for the long term reliability of a pipe system. Electrofusion joints, which are joined at the proper fusion process and procedures, may encounter defects due to the difference of ovality between pipes and coupling, improper fusion process or porosity result from electrofusion joining. These defects can cause the failure of pipeline and by extension, they can be caused the limit to expand the use of plastics pipes. This paper studies inspection results using ultrasonic imaging method for damaged polyethylene electrofusion joints. Gas was leaking from 250mm diameter polyethylene electrofusion joints at February 2004 which was electrofused at December 1994 and operation pressure was 2.45kPa. First, surface inspection was conducted and then in order to find the types of defects examination using ultrasonic imaging method was performed. Lack of fusion and inappropriate inserting for polyethylene pipes into electrofusion coupling were found and causes of the gas leak were judged that misalignment and insert defect. Cutting inspection was performed and each inspection results were compared to. Results of ultrasonic imaging method and cutting inspection were the same.