• Title/Summary/Keyword: 초음파 비파괴평가

Search Result 342, Processing Time 0.027 seconds

Estimation of Rockbolt Integrity by Using Non-Destructive Testing Techniques(I) -Numerical and Experimental of Applicability- (비파괴 시험기법을 이용한 록볼트의 건전도 평가(I) -수치해석 및 실험적 적용성 평가-)

  • Lee, Jong-Sub;Lee, Yong-Jun;Eom, Tae-Won;Han, Shin-In;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.1
    • /
    • pp.3-12
    • /
    • 2006
  • The purpose of this study is to describe the Non-Destructive Testing(NDT) of the rockbolt and investigate the applicability of the NDT methods to estimate the integrity of the rockbolt. To examine the rockbolt integrity including rockbolt itself and grouting material, two methods are adopted: numerical and experimental methods. In the numerical method, the numerical code DISPERSE is used to analyze the dispersion of the rockbolt. The dispersion curve shows the effects of the thickness and stiffness of grouted materials on the embedded rockbolt. Therefore, the optimal frequency for the integrity test of the rockbolt is obtained: 20~120kHz in L(1,0) mode. In the experimental methods, destructive and non-destructive tests are carried out in a laboratory. In the non-destructive test, the low frequency mode generated by an impact and t he high frequency mode generated by an ultrasonic transducer seem to characterize the rockbolt condition readily. The experimental results show that the guided waves attenuate more significantly when the stiffness of the grouted material increases and/or the zone of the defect increases. Meanwhile, the ultimate capacity of rockbolt was evaluated through the pull-out tests and is compared to the NDT results. This study demonstrates that the NDT is a valuable tool for the rockbolt integrity evaluation.

  • PDF

Evaluation of Modulus of Elasticity of Wood Exposed to Accelerated Weathering Test by Measuring Ultrasonic Transmission Time (촉진 열화 목재의 초음파 전달 시간 측정을 통한 탄성 계수의 평가)

  • Park, Chun-Young;Kim, Gwang-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.275-281
    • /
    • 2014
  • In this study, accelerated weathering test was performed with wood, a major material for wooden cultural building. In order to evaluate the deterioration of wood, ultrasonic transmission times were measured to evaluate dynamic modulus of elasticity (MOE), which was verified by determining static MOE using three-point bending test. Ultrasonic transmission time was decreased with an increase in the weathering time levels (0, 500, 1000 hours) while it increased in 1500 and 2000 hours. Distribution of dynamic and static MOE was similar to that of the ultrasonic transmission time measurements. The results mean that the measurement of ultrasonic transmission time was very effective to evaluate MOE of wooden cultural buildings for their preservation and management. This method could be utilized to assess wooden cultural buildings as a way of preserving them in a scientific manner.

Ultrasonic Speckle Surpression Technique for Nondestructive Evaluation of Steam Generator in Nuclear Power plants (핵발전소의 증기발생기 비파괴 평가를 위한 초음파 스펙클 감소 기술)

  • Lee Youngseock;CHO Hyunseob
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.151-154
    • /
    • 2005
  • In this paper, we present a ultrasonic speckle suppression method for centrifugal-casted stainless steel sample by computer simulations of a flaw enhancement algorithm. Because of their practical importance in welds, the ultrasonic signal obtained from heat-affected zone or welds are investigated for computer simulation. The results for computer simulation present the more enhanced flaw-visibility and speckle suppression than the compared two techniques.

  • PDF

A Study on the Size Evaluation of Disc and Band Type Flaw by Ultrasonic Tandem Testing (초음파(超音波)TANDEM사각법(斜角法)에 의한 원형(圓形) 및 띠형결함(形缺陷)의 크기 평가(評價)에 관한 연구(硏究))

  • Han, E.K.;Eom, H.S.;Kim, J.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.5 no.2
    • /
    • pp.12-21
    • /
    • 1986
  • Generally, butt welds with plate thickness $30{\sim}40mm$ are welded with groove angle $40^{\circ},\;60^{\circ},\;70^{\circ}$, etc. In the detection of internal weld defects, oblique testing with single probe has been mainly used. But, recently, in acccordance with enlargement of welded structure, thick plate with 100-200mm are frequently required. Thus I-groove welding method was lately developed and often used. In this case, most frequently generated defects are the lack of weld penetration and incomplete fusion between base metal and welding material. If we would detect by oblique testing with single probe, detecting flaw is occassionally impossible or very underestimated. In this study, the limit for applying tandem method was studied in dise and band type flaws. The estimation of flaw size could be within 10% error compared to real flaws.

  • PDF

The effect of ultrasonic search units on the detectability and size evaluation of planar flaws (초음파(超音波) 탐촉자 특성(特性)이 판형결함(板形缺陷)의 크기 평가(評價)에 미치는 영향(影響))

  • Lee, J.P.;Kim, B.C.;Lim, H.T.;Joo, Y.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.6 no.2
    • /
    • pp.46-56
    • /
    • 1987
  • The effect of ultrasonic search units on the detectability and size evaluation of planar flaws was studied for thicker ferritic material using the technique of the DAC curve and reference level. Cylindrical holes were used as calibration reflectors. The planar flaws such as disc and band types were machined. They were detected and evaluated with different search units and sizing criteria. The value evaluated was compared with the actual dimension of planar flaws.

  • PDF

Experience in Ultrasonic Flaw Estimation and its Excavation on the Weldments of Nuclear Pressure Vessels (원전 압력용기 용접부 초음파탐상, 결함크기 평가 및 결함 수리 경험)

  • Lee, J.P.;Park, D.Y.;Lim, H.T.;Kim, B.C.;Joo, Y.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.11 no.1
    • /
    • pp.52-60
    • /
    • 1991
  • The importance and role of preservice and inservice inspection(PSI/ISI) for nuclear power plant components are intimately related to plant design, safety, reliability and operation etc.. The Korea Atomic Energy Research Institute(KAERI) has been performing PSI/ISI in Korea since the PSI of Kori nuclear power plant, unit 1 had been performed in 1977. KAERI has localized PSI/ISI technology and has done much experience in ultrasonic flaw detection, evaluation and its excavation on the weldments of large pressure vessels. The results of flaw estimation using ultrasonic examination are compared with the actual flaw sizes revealed by field excavation. KAERI's experience regarding PSI/ISI was described and some discussions were added.

  • PDF

The Comparison of Acceptance Criteria and Flaw Size Measurement between ASME and RCC-M Code in Ultrasonic Examination (초음파검사시 ASME와 RCC-M CODE에 따른 결함 크기측정 및 허용기준 비교평가)

  • Kim, B.C.;Lim, H.T.;Lee, J.P.;Joo, Y.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.8 no.1
    • /
    • pp.6-11
    • /
    • 1988
  • The comparison and analysis of flaw detectability, flaw sizing methods and allowable criteria in accordance with the applicable codes, ASME and RCC-M Code, in ultrasonic examination of pressure vessel in nuclear power plants were studied. Accordding to the codes, calibration blocks were made. The artificial flaws such as disc and band types in test specimens were machined. They were detected and evaluated with etch code requirements and measured values were compared with the actual flaws.

  • PDF

Fundamental Study on Degradation Evaluation of Marine Diesel Engine Exhaust Valve by Nondestructive Test (비파괴법에 의한 선박용 디젤엔진 배기밸브의 열화도 평가에 관한 기초적 연구)

  • Sim, K.H.;Kim, H.S.;Nam, K.W.
    • Journal of Power System Engineering
    • /
    • v.3 no.4
    • /
    • pp.51-56
    • /
    • 1999
  • The ultrasonic method, which is well known as nondestructive test method, is widely used to evaluate the material damage due to degradation. However, this method is just used for measuring the crack size and the thickness loss of the tube. The purpose of this study is to investigate the applicability of the ultrasonic technique for the evaluation of marine diesel engine exhaust valve and to suggest the correlations between the ultrasonic characteristics and valve degradation. From the evaluation of the results obtained, the technique of using the ultrasonic property was founds to be a efficient method to evaluate the degree of marine diesel engine exhaust valve by nondestructive test.

  • PDF

초음파 공명을 이용한 원전 연료봉의 산화막 두께 측정

  • 주영상;정용무;정현규
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.204-209
    • /
    • 1998
  • 핵연료 펠렛이 장입되어 있는 원전연료봉 피복관은 핵분열성 물질의 외부 유출에 대한 일차 방호벽 역할을 하므로 원전의 안전성을 위해서는 피복관의 구조건전성 확보가 매우 중요하다. 고온, 고압의 운전 조건 속에서 연료봉 피복관은 산화막이 생성 상장하여 연료봉을 취성 파괴시킬 가능성이 있으므로 이를 가동중에 비파괴적으로 측정할 수 있는 방법을 개발할 필요가 있다. 산화막이 존재하는 지르칼로이 피복관에 대한 음파의 공명산란을 이론적으로 모델링하고 수치해석을 수행하였다. 산화막이 피복된 원통형 쉘의 공명산란에서 공명 원주파의 전파 특성은 산화막의 존재 여부와 그 두께 증가에 따라 크게 변화한다. 수치 해석 결과 제 1차 반대칭 (A$_1$) 원주파의 특정 부분파의 경우에는 산화막의 존재에도 불구하고 위상속도가 일정한 특이성을 보였다. 이러한 위상속도 특성을 실험을 통하여 확인하였으며 이 현상을 이용하여 산화막의 두께를 측정할 수 있는 새로운 비파괴 평가 방법을 제안하였다.

  • PDF

A Size Evaluation for Continuous Flaw Monitoring Using the Tip Diffraction Method (초음파(超音波)의 Tip Diffraction 방법(方法)을 이용한 결함연속감시(缺陷連續監視)를 위한 크기 평가(評價))

  • Jung, H.K.;Cho, C.K.;Kim, B.C.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.7 no.1
    • /
    • pp.42-50
    • /
    • 1987
  • Most of significant defects in the pressure boundaries of nuclear power plant we re dispositioned to be monitored periodically every inservice inspection. Due to the difficulty of the defect sizing during operation, it is necessary to develope the continuous flaw monitoring techniques. The Tip Diffraction method, specifically speaking, spot seems to be suitable for flaw monitoring. The optimum conditions of selecting the transducer were 3.5 MHz and 45-57 degree according to compatibility with the defect height. The effective calculation of the defect height was to assume the fact that the incident beam is parallel. This method would be supplemented to ASME method about the defect characterization for the surface flaw.

  • PDF