• Title/Summary/Keyword: 초음파기술

Search Result 1,184, Processing Time 0.024 seconds

The Study on the Perceptions of Radiological Technologist in Medical Imaging Equipment Used by the Oriental Doctor (한의사의 의료영상장비 사용에 대한 방사선사의 인식도)

  • Choi, Jae-Ho;Kang, Gi-Bong;Kim, Sang-Hyun;Kim, Tae-Hee;Kim, Gyoo-Hyung;Lee, Mi-Hwa;Ahn, Jung-Seong;Hong, Seong-Wan;Lee, Jae-Seok;Kwon, Ick-Su;Park, Jae-Yoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.109-120
    • /
    • 2017
  • In order to examine how Radiological Technologists perceive the oriental doctor's use of Medical Imaging Equipment, surveys were conducted for the members of the Korean Radiological Technologists Association. The total number of respondents were 515 and 481, with 34 insincere responses removed caused of nonvalidated answer. The results of the analysis are as follows. Although there were no statistical significance in the difference in perception by location of residence, work place, and educational background, respondents with higher education showed a tendency to agree on the use of comprehensive medical imaging equipment, but tended to oppose the use of special medical imaging equipment. Differences in perception by gender showed a greater negative perception toward the oriental doctor's use of medical imaging equipment by women than men. In particular, women showed more negative tendency for oriental doctor's use of special medical imaging equipment such as MRI, CT, and ultrasound equipment compared to men, and this was statistically significant. The difference in perception by age showed that the oriental doctor's use of medical imaging equipment was negative in the 20~30s, neutral in the 40~50s, and positive in the 60s, which were statistically significant. The difference in perception by work experience showed that the longer the work experience was, the more positive it was toward oriental doctor's use of medical imaging equipment. Specifically, the most favorable tendency was found with work experience of more than 30 years, which was statistically significant. The results of this study revealed the Radiological Technologists' perceptions on the oriental doctor's use of Medical Imaging Equipment and this can contribute to the direction of public health promotion in the future.

Prevalence and Risk Factors of Gallstones in Adult Health Screening Population (건강한 성인의 담석 유병률과 위험인자)

  • Lee, Mi-Hwa;Kwon, Duck-Moon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.287-294
    • /
    • 2014
  • Gallstone is the most common disease of the biliary system. Korean has experienced an increase in the percentage of cholesterol gallstones. The major risk factors associated with cholesterol gallstones are age, gender as well as obesity. This study was designed to determine the prevalence of gallstones in the last three years and evaluate the associated risk factors in the population who underwent health screening. The study population consisted of 2,484 males and 2,212 females who visited the health promotion center in Dalseogu, Daegu in Korea from January 2011 to December 2013. Each participant in the study had their biliary system gallbladder examined using ultrasonography. Classified as underweight, normal weight or overweight using the population of obese according to the body mass index, and classified according to mood diagnosis of diabetes presented by the American Diabetes Association. Fasting blood glucose and number of liver function, the divided the control group by referring to the normal liver function values used herein. The geological map, I was classified as NCEP APT III. A showed of total 148 people were found to have gallstones. The prevalence of sex among 148 patients (3.15%) 84 men (1.79%) and 64 women 1.36%) which shows significantly there is little difference. 1.84% 40 years and below, 3.38% 40's showed age prevalence was 4.66% in 50's and above. In addition, Total-cholesterol was at the most in 52 people, LDL-cholesterol in 398 people, Triglyceride in 36 people, HDL-cholesterol in 19 people. The abnormal group, was created from the total-cholesterol categories from a physical examination of a subject that has been found to be gallstones in the gallbladder. A result of conducting the univariate analysis shows the prevalence of gallstones, a correlation that is meaningful. The logistic regression analysis of multiple ages was chosen to show risk factors age independent cholelithiasis. In spite of the conclusion, gallstones are not displayed in relation to the metabolic syndrome but in order to clarify this, not only the subject of a health examination is needed but, a further study of the general public when possible.

Association of Metabolic Syndrome and Biochemical Examination of the Gallbladder Polyp (담낭 용종의 대사성 증후군 및 생화학적 검사의 연관성)

  • Park, Young-Joon
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.267-276
    • /
    • 2015
  • The gallbladder(GB) polyps have malignant potential and nowadays are increasing due to the extended use of ultrasonography. Even though there are various reports on the risk of GB polyps, there is few study on the relationship between the presence of metabolic syndrome including serum biochemistry, lifestyle and the development of gallbladder polyps in korean population. The aim of this study is to establish a relationship between the presence of metabolic syndrome including serum biochemistry and the development of gallbladder polyps in korean population. This study conducted on 151 men and 167 women who visited a musculoskeletal hospital in Gyeonggido to have an ultrasound scan of the abdomen from November 2, 2012 to January 31, 2014. They are randomly selected to evaluate the prevalence risk factors were analyzed by comparing various variables between the GB polyp positive and negative. The collected data were analyzed using the personal computer program SPSS version 20.0 for windows. The mean size of the GB polyps was 3.92mm in diameter. Size of GB polyps were less than 10mm in diameter. As to frequency in the people with the GB polyps, the number of patients with the GB polyps was 184(57.9%): the number of metabolic syndrome of them was 114(26.4%); these results showed that risk of the GB polyps got higher at patients with metabolic syndrome. As to the risk of the GB polyps, people with the GB polyps had significantly higher risk than those without the GB polyps, as follows: The risk was significantly 1.061 times higher by weight; 1.186 by BMI; 1.060 by systolic blood pressure; 1.030 by diastolic blood pressure; 1,009 by Total cholesterol; 2.736 by metabolic syndrome; 1.011 by blood sugar on an empty stomach; 1.064 by ESR. The risk factors of GB polyps were found to be weight, BMI, total cholesterol, Triglycerol, Glucose, systolic blood pressure, diastolic blood pressure, ESR and metabolic syndrome. This study has a possibility to be used an indicator to identify the GB polyps, and in the future larger-scale study will have to be conducted to objectify it.

Development of an anisotropic spatial interpolation method for velocity in meandering river channel (비등방성을 고려한 사행하천의 유속 공간보간기법 개발)

  • You, Hojun;Kim, Dongsu
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.7
    • /
    • pp.455-465
    • /
    • 2017
  • Understanding of the two-dimensional velocity field is crucial in terms of analyzing various hydrodynamic and fluvial processes in the riverine environments. Until recently, many numerical models have played major roles of providing such velocity field instead of in-situ flow measurements, because there were limitations in instruments and methodologies suitable for efficiently measuring in the broad range of river reaches. In the last decades, however, the advent of modernized instrumentations started to revolutionize the flow measurements. Among others, acoustic Doppler current profilers (ADCPs) became very promising especially for accurately assessing streamflow discharge, and they are also able to provide the detailed velocity field very efficiently. Thus it became possible to capture the velocity field only with field observations. Since most of ADCPs measurements have been mostly conducted in the cross-sectional lines despite their capabilities, it is still required to apply appropriate interpolation methods to obtain dense velocity field as likely as results from numerical simulations. However, anisotropic nature of the meandering river channel could have brought in the difficulties for applying simple spatial interpolation methods for handling dynamic flow velocity vector, since the flow direction continuously changes over the curvature of the channel shape. Without considering anisotropic characteristics in terms of the meandering, therefore, conventional interpolation methods such as IDW and Kriging possibly lead to erroneous results, when they dealt with velocity vectors in the meandering channel. Based on the consecutive ADCP cross-sectional measurements in the meandering river channel. For this purpose, the geographic coordinate with the measured ADCP velocity was converted from the conventional Cartesian coordinate (x, y) to a curvilinear coordinate (s, n). The results from application of A-VIM showed significant improvement in accuracy as much as 41.5% in RMSE.

A Study on the Relationship between Adiponectin, BDNF and Leptin with Abdominal Fat Thickness in Male Workers (남성 근로자의 복부지방두께와 adiponectin, BDNF 및 leptin의 관련성)

  • Ko, Kyung-Sun;Choi, Yoon-Jung
    • Journal of radiological science and technology
    • /
    • v.36 no.3
    • /
    • pp.209-217
    • /
    • 2013
  • Adiponectin (AdipoN), brain-derived nerotrophic factor (BDNF) and leptin (LeP) are mainly secreted from adipose tissue and are known to be involved in regulation of the development of obese. However, there are not many studies on the association between abdominal fat and neuropeptides such as AdipoN, BDNF and LeP. The aim of this study was undertaken to investigate the association between abdominal fat thickness, neuropeptides and cardiovascular disease (CVD) risk factors. The participants in the study were 138 male employees without CVD. This study was approved by the Institutional Review Board of Occupational Safety and Health Research Institute. Written informed consent for the participants in this study was obtained from all individuals. We obtained subcutaneous fat thickness (SFT) and visceral fat thickness (VFT) by using ultrasonography and neuropeptides levels were measured with ELISA kit according to the method suggested by kit manufacturer. The mean SFT and VFT were $1.58{\pm}0.51$ and $4.52{\pm}1.44$ cm. The mean concentrations of AdipoN, BDNF and LeP were $3.14{\pm}3.52$ ng/ml, $24.11{\pm}8.52$ pg/ml and $4.27{\pm}2.38$ ng/ml, respectively. VFT were positively correlated with total cholesterol (r=0.217, p<0.05), LDL-cholesterol (r=0.271, p<0.01), triglyceride (r=0.233, p<0.05) and insulin (r=0.338, p<0.01), but was inversely correlated with HDL-cholesterol (r=-420, p<0.01). AdipoN levels were positively correlated with HDL-cholesterol (r=0.220, p<0.05) and were inversely correlated with total cholesterol (r=-0.196, p<0.05), LDL-cholesterol (r=-0.190, p<0.05), triglyceride (r=-0.199, p<0.05), SFT (r=-0.195, p<0.05) and VFT (r=-0.412, p<0.01). However, LeP levels showed a reverse trend to AdipoN. AdipoN level was significantly higher in non-obese participants (BMI<25 kg/m), but LeP concentration was significantly higher in obese participants (BMI>25 kg/m) than in non-obese. On multiple logistic regression analysis, obese were significantly associated with AdipoN (odds ratio=0.784) and LeP (odds ratio=1.494). These results suggested that AdipoN and LeP concentrations are affected abdominal fat and that dysfunction and/or declination in the production and secretion of neuropeptides might induced ultimately obese and CVD.

Acoustic Scattering Characteristis of the Individual Fish (어체의 초음파 산란특성에 관한 연구)

  • 신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.1
    • /
    • pp.21-30
    • /
    • 1991
  • The estimation of the fish biomass density or the size of fish by means of the acoustic equipment is an important part in the quantitative assessment of fisheries resources. The precision of such estimates depend upon the target strength of fish and the accuracy to which the acoustic equipment has been calibrated. This paper examine the accuracy of the digital measurement system which is manufactured by way of trial in order to masure the target strength of fish, and calibrations of that system carry out with an ogive and a ellipsoid made of the aluminum and the epoxy, respectively. Furthermore, measurements of target strength for eight species of fish are made at 25, 50, 100 kHz. The accuracy of the digital measurement system is compared the theory with measurements on ogive and ellipsoid, and the agreement is reasonable. Result of establishments on the target strength to fish length and to fish weight regression obtained from the measurements are available to provide the methods of design for use in interpreting acoustic measurements of fish abundance on the experimented eight species.

  • PDF

Studies on Estimation of Fish Abundance Using an Echo Sounder ( 1 ) - Experimental Verification of the Theory for Estimating Fish Density- (어군탐지기에 의한 어군량 추정에 관한 기초적 연구 ( 1 ) - 어군량추정이론의 검증실험 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.1
    • /
    • pp.1-12
    • /
    • 1991
  • An experiment has been carefully designed and performed to verify the theory for the echointergration technique of estimating the density of fish school by the use of steel spheres in a laboratory tank. The spheres used to simulate a fish school were randomly distributed throughout the insonified volume to produce the acoustic echoes similar to those scattered from real fish schools. The backscattered echoes were measured as a function of target density at tow frequencies of 50kHz and 200kHz. Data acquisition, processing and analysis were performed by means of the microcomputer-based sonar-echo processor including a FFT analyzer. Acoustic scattering characteristics of a 36cm mackerel was investigated by measuring fish echoes with frequencies ranging from 47.8kHz to 52.0kHz. The fluctuation of bottom echoes caused by the effects of fish-school attenuation and multiple scattering which occurred in dense aggregations of fishes was also examined by analyzing the echograms of sardine schools obtained by a 50kHz telesounder in the set-net's bagnet, and the echograms obtained by a scientific echo sounder of 50kHz in the East China Sea, respectively. The results obtained can be summarized as follows: 1. The measured and the calculated echo shapes on the steel sphere used to simulate a fish school were in close agreement. 2. The waveform and amplitude of echo signals by a mackerel without swimbladder fluctuated irregularly with the measuring frequency. 3. When a collection of 30 targets/m super(3) lied the shadow region behind another collection of 5 targets/m super(3), the mean losses in echo energy for the 30 targets/m super(3) were about -0.4dB at 50kHz and about -0.2dB at 200kHz, respectively. 4. In the echograms obtained in the East China Sea, the bottom echoes fluctuated remarkably when the dense aggregations of fish appeared between transducer and seabed. Especially, in the case of the echograms of sardine school obtained in a set-net's bagnet, the disappearance of bottom echoes and the lengthening of the echo trace by fish aggregations were observed. Then the mean density of the sardine school was estimated as 36 fish/m super(3). It suggests that when the distribution density of fishes in oceans is greater than this density, the effects of fish-school attenuation and multiple scattering must be taken into account as a possible source of error in fish abundance estimates. 5. The relationship between mean backscattering strength (, dB) and target density ($\rho$, No./m super(3)) were expressed by the equations: =-46.2+13.7 Log($\rho$) at 50kHz and =-43.9+13.4 Log($\rho$) at 200kHz. 6. The difference between the experimentally derived number and the actual number of targets gradually decreased with an increase in the target density and was within 20% when the density was 30 targets/m super(3). From these results, we concluded that when the number of targets in the insonified volume is large, the validity of the echo-integration technique of estimating the density of fish schools could be expected.

  • PDF

Partial Anomalous Pulmonary Venous Connection to the Superior Vena Cava

  • Lee, Sub;Kim, Han-Woong;Kang, Hyoung-Seok;Bae, Chi-Hoon;Jheon, Sang-Hoon;Kwon, Oh-Choon;Ahn, Wook-Su
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.672-679
    • /
    • 2001
  • Background: Surgical correction of partial anomalous pulmonary venous connection to the superior vena cava has been associated with postoperative venous obstruction and sinus node dysfunction. In this paper we describe our current approach and its short-term results. Material and Method: Between April 1999 and January 2000, 5 consecutive patients, ranging from 2 months to 66 years old, underwent corrective operation for partial anomalous pulmonary venous connection to the superior vena cava at Sejong General Hospital and Daegu Catholic University Medical Center. Surgical correction involved diversion of the pulmonary venous drainage to the left atrium using a right atrial flap(2 patients) or prosthetic patch(3 patients) with division of the superior vena cava superior to the restore site of the pulmonary veins and reimplantation on the right atrial appendage to restore systemic venous drainage. Result: All patients were discharged between postoperative day 9 and 15 without complications. One Russian boy returned to his country, therefore, he was lost to follow-up after discharge. Remaining 4 patients were asymptomatic and in normal regular sinus rhythm at a mean follow-up of 17.75$\pm$4.27 months. Follow-up echocardiographic study (range, 12 to 24 months) revealed no incidence of narrowing of the venous pathways or of residual shunt. Conclusion: Our current approach is relatively simple and reproducible in achieving unobstructive pulmonay venous and SVC pathways. By avoiding incision across the cavoatrial junction, surgical injury to the sinus node and its artery may be minimized. The presented surgical technique can be safely and effectively applied to the selected patients.

  • PDF

Optimum Synthesis Conditions of Coating Slurry for Metallic Structured De-NOx Catalyst by Coating Process on Ship Exhaust Gas (선박 배연탈질용 금속 구조체 기반 촉매 제조를 위한 코팅슬러리 최적화)

  • Jeong, Haeyoung;Kim, Taeyong;Im, Eunmi;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.24 no.2
    • /
    • pp.127-134
    • /
    • 2018
  • To reduce the environmental pollution by $NO_x$ from ship engine, International maritime organization (IMO) announced Tier III regulation, which is the emmision regulation of ship's exhaust gas in Emission control area (ECA). Selective catalytic reduction (SCR) process is the most commercial $De-NO_x$ system in order to meet the requirement of Tier III regulation. In generally, commercial ceramic honeycomb SCR catalyst has been installed in SCR reactor inside marine vessel engine. However, the ceramic honeycomb SCR catalyst has some serious issues such as low strength and easy destroution at high velocity of exhaust gas from the marine engine. For these reasons, we design to metallic structured catalyst in order to compensate the defects of the ceramic honeycomb catalyst for applying marine SCR system. Especially, metallic structured catalyst has many advantages such as robustness, compactness, lightness, and high thermal conductivity etc. In this study, in order to support catalyst on metal substrate, coating slurry is prepared by changing binder. we successfully fabricate the metallic structured catalyst with strong adhesion by coating, drying, and calcination process. And we carry out the SCR performance and durability such as sonication and dropping test for the prepared samples. The MFC01 shows above 95% of $NO_x$ conversion and much more robust and more stable compared to the commercial honeycomb catalyst. Based on the evaluation of characterization and performance test, we confirm that the proposed metallic structured catalyst in this study has high efficient and durability. Therefore, we suggest that the metallic structured catalyst may be a good alternative as a new type of SCR catalyst for marine SCR system.

A Study on the Adsorption and Desorption Characteristics of Metal-Impregnated Activated Carbons with Metal Precursors for the Regeneration and Concentration of Ammonia (암모니아의 재생 및 농축을 위한 금속 전구체에 따른 금속 첨착 활성탄의 흡착 및 탈착 특성에 관한 연구)

  • Cho, Gwang Hee;Park, Ji Hye;Rasheed, Haroon Ur;Yoon, Hyung Chul;Yi, Kwang Bok
    • Clean Technology
    • /
    • v.26 no.2
    • /
    • pp.137-144
    • /
    • 2020
  • Metal-impregnated activated carbons were prepared via ultrasonic-assisted impregnation method for regeneration and low ammonia concentration. Magnesium and copper were selected as metals, while chloride (Cl-) and nitrate (NO3-) precursors were used to impregnate the surface of activated carbon. The physical and chemical properties of the prepared adsorbents were characterized by TGA, BET, and NH3-TPD. The ammonia breakthrough test was carried out using a fixed bed and flowing ammonia gas (1000 mg L-1 NH3, balanced N2) at 100 mL min-1, under conditions of temperature swing adsorption (TSA) and pressure swing adsorption (PSA, 0.3, 0.5, 0.7, 0.9 Mpa). The adsorption and desorption performance of ammonia were in the order of AC-Mg(Cl) > AC-Cu(Cl) > AC-Mg(N) > AC-Cu(N) > AC through NH3-TPD and TSA and PSA processes. AC-Mg(Cl) using MgCl2 showed the average adsorption amount of 2.138 mmol/g at TSA process. Also, AC-Mg(Cl) showed the highest initial adsorption amount of 3.848 mmol/g at PSA 0.9 Mpa. When metal impregnated the surface of the activated carbon, it was confirmed that not only physical adsorption, but also chemical adsorption increased, making enhancement in adsorption and desorption performances possible. Also, the prepared adsorbents showed stable adsorption and desorption performances despite repeated processes, confirming their applicability in the TSA and PSA processes.