• 제목/요약/키워드: 초음파기기

검색결과 213건 처리시간 0.025초

한우에 있어서 초음파기기를 이용한 생체내 개체별 난자 채취 빈도 및 수정란 생산효율에 관한 연구 (Effect of Ovum Pick-up Frequency on In Vitro Production of Embryos in Hanwoo Cattle)

  • 박성재;양보석;임기순;성환후;양병철;장원경;정일정;정기화;심보웅
    • 한국수정란이식학회지
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2000
  • The ultrasound-guided oocytes cllection (ovum pick-up ; OPU) has become a substitution for superovlation in cattle. The objective of this study was to examine the effect of OPU frequency on the in vitro production of embryos in Hanwoo cattle. Six cycling Hanwoo cows were distributed into two groups for either once or twice weekly OPU sessions. Oocytes were collected by ultrasound-guided follicle aspiration(SA600) using a 6.5HMz transducer and attached with 18 gauge needle, with vacuum pressure of 40 mmHg. The cumulus-oocyte complexes (COCs) collected from each donor were matured in TCM 199 supplemented with 10% fetal bovine serum at 5% CO2 in air at 38.5$^{\circ}C$ for 22h and in vitro matured oocytes were co-incubated with sperm(separated by Percoll gradient) for 6h. The zygotes were co-cultured on cumulus cell monolayer in 10ul droplets in the same culture medium and conditions used for IVM for 7 days. On Day 7 of culture, development to blastocysts was examined. Although the number of oocytes collected was variable depending on individuals, overall embryo production in the twice per week OPU sessions was better that in the once per week sessions(6~21 vs 2~7 blastocysts produced, respectively). Two cows(E, A) were good oocyte donors and embryo production was superior in cow C ; however, cow F was a poor donor as compared to the others. In conclusion, these results suggest that for embryo production, twice weekly OPU sessions were better than once per week for producing embryos in vitro from Hanwoo cattle.

  • PDF

Rayleigh Wave를 이용한 KTX 제동 디스크의 균열 검측 시스템 개발 (Development of Nondestructive System for Detecting the Cracks in KTX Brake Disk Using Rayleigh Wave)

  • 김민수;염윤택;박진현;송성진;김학준;권성덕;이호용
    • 비파괴검사학회지
    • /
    • 제37권1호
    • /
    • pp.29-36
    • /
    • 2017
  • 최근 KTX (Korean Train Express) 열차의 사고의 대부분은 기기의 오작동, 차량 부품의 노후와에 따른 고장 및 장애발생, 신호장치에 대한 인적오류 등이 주된 원인이였다. 특히, 차량부품 중 제동 디스크의 파손은 하부 차축 및 차륜에 충격을 가해 탈선의 우려와 고속 충돌 등 대형 인명 피해를 낳을 수 있다. 따라서 본 연구에서 KTX의 제동 디스크(Solid Type, Ventilation Type)를 형상화하고, 이를 동작시켜 균열을 측정하여 DB화 할 수 있는 균열검측시스템을 구축하였다. 제동 디스크의 표면균열을 검사하기 위하여 Rayleigh wave를 이용하였으며 수침기법으로는 제동디스크 장착상태에서 탐상의 어려움이 인하여 국부수침 탐상기법을 활용하여 제동디스크의 초음파 검사모듈을 개발하였다. 또한 제동디스크의 회전에 따라 측정된 균열을 저장할 수 있는 균열검측 자동화장치와 제동 디스크의 초음파 검사모듈을 이용하여 제동 디스크의 표면결함을 평가하였다.

TRUS 전립선 영상에서 가버 텍스처 특징 추출과 평균형상모델을 적용한 전립선 경계 검출 (Detecting the Prostate Boundary with Gabor Texture Features Average Shape Model of TRUS Prostate Image)

  • 김희민;홍석원;서영건;김상복
    • 디지털콘텐츠학회 논문지
    • /
    • 제16권5호
    • /
    • pp.717-725
    • /
    • 2015
  • 전립선 영상은 비용이 상대적으로 저렴한 경직장 초음파 영상을 이용하여 전립선 진단에 많이 사용된다. 경직장 초음파 영상은 3차원으로 촬영되어 여러 장으로 하나의 진단 단위가 만들어 진다. 의사는 진단을 위해 2차원 영상을 순서대로 모니터에 표시하여 볼 수도 있고, 3차원의 영상을 볼 수도 있다. 2차원 영상은 원 영상을 그대로 출력하면 되지만, 3차원 영상은 다양한 각도에서 보이기도 하고, 내부의 어떤 면을 자른 형태로도 보여야 하므로 정확하게 전립선과 배경을 구분하여야 한다. 특히 경계를 구분할 때, 전립선의 중간 부분은 상대적으로 구분하기 쉬우나, 기저부와 첨단부는 불확실한 부분이 많으므로 경계를 구분하기기 매우 어렵다. 이에, 본 논문은 평균 형상 모델을 적용하여 전립선 경계를 추출하는 방법을 제안하고, 실험을 통하여 기존의 방법에 비해 우수함을 보인다.

실규모 하천 계측자료 기반 만곡 전후 2차류 흐름패턴 상세 분석 (Detailed Analysis for Secondary Flow Pattern Before and After Channel Bend in Actual River)

  • 손근수;김동수;김서준;김종민
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.80-80
    • /
    • 2015
  • 만곡부가 연속적으로 발생하는 사행하천은 만곡의 영향으로 2차류가 발생한다. 이러한 2차류의 영향은 하상변동, 제방침식 등의 문제를 발생시켜 사행수로의 흐름특성을 분석하기 위한 많은 연구들이 진행되어 왔다. 하지만, 대부분의 연구들은 실규모 하천의 유속측정의 어려움, 측정이 가능한 시설 및 경제적 제한으로 인해 주로 실내실험에서 측정된 자료를 이용하여 분석을 수행하여 흐름조건이 상이한 실제 하천에서 적용성에 한계가 있어 왔다. 본 연구에서는 상세한 3차원 유속 측정이 가능한 최신 계측기기인 초음파도플러유속계(ADCP)를 활용하여 실제하천과 유사한 흐름 상태 및 지형을 재현한 한국건설기술연구원 안동하천실험센터의 사행도 1.2, 1.5, 1.7의 실규모 사행수로에서 횡단면 측정을 수행하였다. 또한 초음파지점유속계(ADV)를 사행도 1.2의 ADCP 측정 단면과 동일한 횡단면에서 측정하여 공간평균된 ADCP 유속자료를 이용한 흐름패턴 분석의 적용성을 검증하였다. 그 결과 공간평균된 ADCP 유속분포는 시간평균한 ADV 유속분포와 다소 크기의 차이는 발생하였지만 패턴은 매우 유사하게 나타났다. 따라서, 공간평균된 ADCP 유속분포를 이용하여 2차류에 의한 흐름패턴 분석을 수행하였다. 2차류 패턴은 만곡의 위치에 따라 매우 복잡한 형태로 나타났다. 2차류에 의한 최대유속선과 최대수심선의 발생위치를 분석한 결과, 만곡의 정점부를 기준으로 만곡 전인 유입부에서는 이격되고 만곡 후인 유출부에서는 유사한 경로를 나타내고 있었다. 이때의 2차류강도(Secondary Current Intensity; SCI)는 만곡의 정점부 부근에서 최대로 증가했다가 다시 감소하는 결과를 보였다.

  • PDF

드론 기반 초분광 영상의 수집과 활용 (Collection and Utilization of Hyperspectral Image Based on UAV)

  • 유호준;김동수;김서준
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.76-76
    • /
    • 2019
  • 최근 기후변화로 인해 퇴적 및 세굴이 심화되었고, 4대강 사업으로 인해 급격한 하천 지형 변화가 발생하였다. 특히, 4대강 사업 이후 하상변동 모니터링에 대한 지속적인 수요가 증가하고 있다. 이에 따라 개정된 하천법에 따르면 하상변동조사를 기본 10년 주기로 정기적으로 실시하되, 퇴적 및 세굴 발생 구간에 대해서는 기본 2년을 기준으로 하상변동이 큰 곳에 대해서는 1년 주기로, 하상변동이 작은 곳에 대해서는 5년 주기로 실시해야 한다. 하지만 기술 및 예산의 한계로 인해 하상변동조사의 경우 현장 유사량 및 하상토 입도 측정과 유량-총유사량 관계식을 활용하여 모델링을 통해 하상변동을 예측하고 있는 실정이다. 하상변동은 기본적으로 하천 수심을 기본으로 하고 있으며, 사람이 직접 투입하여 임의의 지점에 대한 수심 계측을 실시하고 있다. 하지만 직접 수심 계측의 경우 낮은 자료의 밀도로 인해 많은 인력과 예산, 시간이 소요되며 무엇보다도 관측 대상인 물이라는 작업환경에서는 인명피해가 발생할 수 있는 문제점을 가지고 있다. 최근에는 이러한 한계를 극복하기 위해 초음파 센서가 탑재된 이동식 보트를 활용하여 경로형 수심 계측을 실시하고 있으나, 초음파 센서가 가지는 기기적 한계로 인해 약 50cm 이하에 대한 수심은 측정이 어려운 실정이다. 특히, 국내 하천의 경우는 홍수기를 제외하면 수심이 얕기 때문에 얕은 수심에 대한 자료 확보가 어려워 공간적 정밀도 확보가 어려운 실정이다. 따라서 기존의 하천계측의 패러다임을 지점, 선형 계측이 아닌 면 측량을 실시를 통해 높은 밀도의 자료를 확보해야 한다. 이러한 측량이 가능한 기술로 하천원격탐사가 대안으로 제시되고 있다. 하천원격탐사는 직접 접촉하지 않고, 대상체의 광학적 특성을 통해 물리적 특성을 파악하는 기술로서 적은 시간에 높은 밀도의 자료의 확보와 저예산의 고효율 방법으로 알려져 있다. 본 연구에서는 기존의 하천원격탐사에서 활용한 고비용, 저해상도의 시공간 스케일에 해당하는 위성 및 유인항공기가 아닌 하천의 흐름방향으로 비행이 가능하고 상대적으로 저비용, 고해상도의 시공간 스케일의 측정이 가능한 드론을 활용하여 하천원격탐사를 수행하는 방법에 대해 논하고자 한다. 특히, 기술적 한계가 존재하는 청색, 녹색, 적색에 해당하는 RGB 영상을 활용한 하천원격탐사를 극복하기 위한 대안으로 초분광 영상을 수집하고 활용하는 방법을 제시하고자 한다.

  • PDF

초음파기기를 이용한 맥상(脈象) 연구 (A Study on Pulse Pattern Using Ultrasonic Device)

  • 김희영;박정빈;금유정;여인금;엄동명;송지청
    • 대한한의학원전학회지
    • /
    • 제34권2호
    • /
    • pp.85-94
    • /
    • 2021
  • Objectives : Pulse diagnosis is one of the main diagnostic methods of Korean Medicine that understands the patient's condition and illness by reading changes in the patient's pulse, which is described in terms of pulse condition While they are described in detail in medical texts, it is difficult to grasp their true nature, as the written descriptions fail to do justice to the experience of pulse taking it tries to convey. As a way to approach pulse condition the effect of the body's tension on the radial vein was measured using an ultrasonic device, after which the measured changes and how they could be reflected in pulse condition were studied. In other words, changes in the radial vein following induced tension were analyzed. Methods : 1) The thickness of the subject's radial vein was measured using a linear probe of an ultrasonic device[LOGIQ 5 Basic, GE, USA]. 2) Fatigue level was increased through artificial stimulation using the Gripmeter[ks-301, Lavisen, Korea]. 3) Thickness of the radial vein post tension induction was measured. 4) The results were analyzed with the Tukey test or paired t-test as post hoc tests. Results : Thickness of the radial vein of the subject pre- and post- Gripmeter stimulation decreased with significance. Conclusions : Constriction of the radial vein that happened after tension induction could be linked to the Tight Pulse[緊脈] that is related to patterns of contraction and pulling.

초음파 센서 통신선 연장을 위한 인터페이스 변환 (Interface Conversion to Extend Communication Cable of Ultrasonic Sensor)

  • 서대일;권병혁;김상진
    • 한국전자통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.467-472
    • /
    • 2022
  • 3차원 초음파풍속계는 PC와 RS232C(:Recommended Standard 232C) 인터페이스로 연결하여 관측 자료를 전송한다. 관측 장소에 따라 PC와 센서를 연결하는 케이블 연장이 필요한 경우가 종종 발생한다. 항공기상청 항공기상관측장비 테스트베드에서 PC를 두는 콘테이너와 장비 설치하는 곳까지 거리가 30 m 이상 되어 본래의 AWM2919(:Appliance Wiring Material 2919) 케이블로의 연장이 필요했다. 문제 해결을 위해서 AWM2919 케이블 연장, PC와의 인터페이스를 RS232C에서 RS485로 개조, RS485 검사 등의 조치를 하였다. 연장된 케이블로 장비를 설치한 후에 원격으로 자료를 수집하고 분석하여 성공적인 케이블 연장을 확인하였다.

근골격계 초음파 진단기기를 활용한 견관절 통증 환자의 초음파 소견: 후향적 관찰 연구 (Musculoskeletal Ultrasound Findings of Shoulder Pain Patients: A Retrospective Observational Study)

  • 김현태;박혜진;이연우;박선영;허인;황의형;신병철;황만석
    • 한방재활의학과학회지
    • /
    • 제33권2호
    • /
    • pp.77-85
    • /
    • 2023
  • Objectives The aim of this study is to retrospectively evaluate the shoulder lesions in patients experiencing shoulder pain through the use of musculoskeletal ultrasound during Korean medicine intervention treatments. Methods A total of 20 cases were collected, including biceps tendinitis (n=4), calcification (n=3), SASD bursitis (n=4), partial tear (n=2), full-thickness tear (n=1), tendinopathy (n=5), and impingement syndrome (n=1). Musculoskeletal ultrasound was used by Korean medicine doctors to perform real-time scanning and to explain the patient's condition during treatment sessions. Results The use of musculoskeletal ultrasound allowed Korean medicine doctors to perform treatments such as pharmacoacupuncture, acupotomy, and acupuncture more safely and effectively. Patients were able to better understand their conditions through real-time imaging and explanations provided by the doctors. Conclusions Musculoskeletal ultrasound has the potential to enhance the safety and efficacy of Korean medicine intervention treatments for patients with shoulder pain. Institutional or governmental support is needed to further promote the use of medical devices by Korean medicine doctors, ultimately leading to an increase in cases and clinical evidence.

초분광 영상을 활용한 최대추정가능수심 산정 기법 개발 (Estimation of maximum measurable depth using hyperspectral image)

  • 서영철;김동수;유호준;권영화
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.444-444
    • /
    • 2022
  • 하천 수심 계측은 수심을 사람이 직접 계측하거나 초음파 기반 유속계 (ADCP) 등 최신 계측기기를 이용하여 간접적으로 계측을 실시하고 있다. 하지만 사람이 직접 하천에서 수심을 측정하는 것은 위험이 동반되고, 수심자료의 측정오차가 크게 발생한다. 따라서 수심측정에서 직접 측정 방식의 한계를 극복하기 위해, 초분광 영상의 반사도와 수심이 높은 상관관계를 보이는 것을 활용하여, 초분광 영상 기반 수심 산정 기법을 개발하였다. 초분광 영상 기반 수심 산정 기법은 복수의 파장이 존재하는 초분광영상으로부터 두 개의 파장대의 밴드를 추출하여 모든 경우의 수에 대해 밴드비를 산정한 후, 실측수심과 밴드비 간의 회귀분석을 실시하여 상관계수가 가장 높은 회귀식을 찾아내는 방식이 최적 밴드비 분석법에 기반한다. 최적 밴드비 분석법을 통해 획득된 높은 상관성의 밴드비-수심 관계식을 이용하여 수심을 추정할 수 있다. 이러한 방법은 직접 수심 측정 방식에 비해, 높은 해상도와 밀도, 양질의 데이터를 수집할 수 있는 장점이 있다. 과거 연구에 따르면 저수심부에서의 높은 정확도의 수심추정 결과를 보였지만, 고수심부에서는 실측수심과의 오차도 높아지는 등 정확성이 떨어지는 경향을 보인다. 따라서 본 연구에서는 보다 효율적인 수심계측을 할 수 있도록 최적 밴드비 분석법을 활용한 수심추정에서 신뢰성 있는 수심의 범위를 파악할 수 있는 방법을 제시하고자 한다. 본 연구에서는 대상지역으로 낙동강 본류와 황강 지류 합류부로 선정하였고, 초음파 기반 유속계(ADCP)와 드론을 활용하여 실측수심과 초분광 영상을 취득하였다. 민감도 분석을 위한 수심자료를 0.5m 단위로 분할하였으며, 구간별로 최적 밴드비 분석을 실시하였다. 그 결과, 구간별로 산정된 상관계수와 평균제곱근오차 (RMSE)를 통해 정확도가 높은 구간을 구별할 수 있었다. 또한 해당 구간을 초과하는 수심은 초분광 영상을 통해 추정이 어려운 것으로 판단되며, 분석한 구간까지를 최대 추정 가능 수심으로 정의하였다. 마지막으로 검증을 위해 최대추정가능수심으로 판단된 구간까지의 데이터만 활용하여 최적 밴드비 분석법을 적용하여 상관계수나 평균제곱근오차 결과의 개선여부 확인을 통해, 본 연구에서 제시한 방법이 정확한 최대추정가능수심 구간을 산정할 수 있는지 확인하였다.

  • PDF

유전자 분석을 통하여 선발된 한우로부터 초음파 유래 체외수정란 이식에 의한 고품질 한우 생산기술의 실용화 I. DNA 검정우에서 초음파기기를 이용한 난포란의 채란에 관한 연구 (Practical Applications of DNA Marker-Assisted Selection and OPU-Derived IVF Embryo Transfer for the Production of High Quality Meat in Hanwoo I. Collection of Follicular Oocytes with Ultrasound-Guided Transvaginal Ovum Pick-Up from DNA Marker-proved Hanwoo)

  • 박희성;이지삼;진종인;박준규;홍승표;이명열;정장용
    • 한국수정란이식학회지
    • /
    • 제16권3호
    • /
    • pp.183-191
    • /
    • 2001
  • 본 연구는 고품질육의 DNA marker가 규떵된 한우로부터 초음파유노 난포란의 연속적 채취를 통하여 능력이 우수한 한우 수정란온 대량생산하는 방법의 확립과 이를 한우농가에 응용하고자 초음파 난자채취기를 이용하여 등지방층두께, 일당증체량, 근내지방도 및배최장근 단면적에 연관된 DNA marker를 보유하고 있는 한우 5두로부터 개체및 난포수, 채취방법, 회수한 난포란의 등급 등을 조사하였다. 한우 5두의 개체별 난포수는 6, 10, 5, 4 및 11회 관찰하여 각각 59개(9.8$\pm$4.5개), 82개(8.2$\pm$4.8개), 83개(16.6$\pm$2.6개), 50개(12.5$\pm$0.5개) 및 79개(7.2$\pm$3.1개)였으며, 모두 36회에 걸쳐 관찰하였던 바 353개(9.8$\pm$4.9개)의 난포를 확인할 수 있었다. 전체 난포수는 small(227개), medium(112개), large follicles(14개) 순으로 나타났으며, 개체별 평균 난포수는 5101번 개체가 평균 16.6$\pm$2.6개로써 가장 높았다. 개체별 난포란의 회수율은 5101번 개체가 89.3%(50/56 ; >2mm) 및 94%(47/50 ; $\leq$2mm)로써 가장 높게 나타났으며, 5두 전체 회수율은 $\leq$2mm(손가락 촉지)가 85.7%(132/154)로써 >2mm (초음파 image)의 74.2%(201/271)보다 유의적 (P<0.01)으로 높게 나타났다. >2mm의 난포에서 채취한 회수란의 등급은 각각 1.0%(G I). 5.0%(G II), 31.3%(G III) 및 62.7%(G IV)로 나타났으며, $\leq$2mm의 난포로부터 채취한 회수란을 각각 2.3%(G I), 16.7%(II),38.6%(G III) 및 42.4%(G IV)의 등급별 회수을 보였다. 1등급(G I) 난포란은 2~6mm 난포에서 1개(1.1%)였으며, 2등급(G II)은 $\leq$2mm, 2-6mm 및 $\geq$6mm 난포에서 각각 5개(3.3%), 11개(11.7%) 및 3개(33.3%)로써 $\geq$6mm 난포에서 가장 높게 나타났다. 3등급(G III) 난포란도 각각 43개(28.9%). 35개(37.2%) 및 5개(55.6%)로써 $\geq$6mm 난포에서 가장 높았으나, 4등급(GIV) 난포란은 $\geq$6mm 난포에서 1개(11.1%)로써 $\leq$2mm 및 2-6mm 난포에서의 101개(67.8%) 및 47개(50.0%) 보다 매우 낮게 나타났다. 전체 회수 난포란수도 4등급이 59.1%(149/252)로써 1, 2, 3등급의 0.4% (1/252), 7.6%(19/252) 및 32.9%(83/252)보다 높게 나타났다. 1회 평균 회수 난포란은 $\leq$2mm 난포에서 4.8$\pm$3.7개로써 2-6mm(3.0$\pm$3.4개) 및 $\geq$6mm (0.3$\pm$0.6개)보다 높았으며, 1회당 평균 8.1$\pm$5.1개의 난포란을 회수하였다.

  • PDF