• Title/Summary/Keyword: 초음파건

Search Result 128, Processing Time 0.023 seconds

Blind and Ultrasonography-guided Injection Therapy for Calcific Tendinitis of Supraspinatus (극상건 석회화 건염에 대한 맹검 주사요법과 초음파하 주사요법)

  • Moon, Young-Lae;Nam, Gi-Young;Noh, Kyung-Hwan
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.86-90
    • /
    • 2008
  • Purpose: To evaluate the differences between blindly and ultrasonography (US)-guided during multiple needling and dextrose injection technique for calcific tendinitis of shoulder. Materials and Methods: We chose 36 symptomatic calcific tendinitis patients, whose age ranged from 27 to 69. Our procedures were multiple needling and injection of dextrose over the lesion of calcific deposits. The bind injection group were 19 patients whose age ranged from 27 to 64-year-old (mean 52.2), and the US-guided injection group were 17 patients ranged from 31 to 69-year-old (mean 49.0). We compare these groups by VAS (visual analogue scale) and range of motion before and after procedures. Results: There is no difference between two groups in VAS and ROM before procedure (p>0.05). Two groups revealed significant improvement without limitation of shoulder function, however, the group under US-guided revealed better results than under blind (VAS:p=0.001, Flexion:p=0.000, Abduction:p=0.000, External rotation: p=0.016). Conclusion: Ultrasonography-guided procedure showed better results than blind, so the use of ultrasonography is more promising procedure.

  • PDF

Ultrasonographic Finding of Acetabular Labral Tear Accompanied with Iliopsoas Bursitis: 2 Cases Report (장요 점액낭염과 동반된 비구순 파열의 초음파 소견: 2예 보고)

  • Lee, Kyung-Jae;Min, Byung-Woo;Cho, Chul-Hyun;Park, Jin-Hyun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.97-100
    • /
    • 2011
  • The iliopsoas bursa lies between the iliopsoas tendon and the anterior hip joint capsule and is difficult to detect by ultrasonography in normal setting. However, some of them communicated with the hip joint and the iliopsoas bursitis can be detected as a reflection of intra-articular pathology. We report two cases of acetabular labral tear accompanied with the iliopsoas bursitis detected by ultrasonography.

  • PDF

Cause of Pes Anserinus Tenderness (거위발 건 압통의 원인)

  • Kim, Jung-Man;Lee, Dong-Yeob;Koh, In-Jun;Kim, Sang-Il
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.1
    • /
    • pp.13-17
    • /
    • 2009
  • Purpose: The purpose of this study was to know the cause of the tenderness at pes anserinus. Materials and Methods: Out of 24 patients with tenderness at pes anserinus, 23 patients were female and 1 patient was male, and their average age was 65.9 years old. We checked the tenderness at pes anserinus by history taking & physical examniation and then, checked the pes anserinus for the presence of bursitis by US in outpatient clinic. With no evidence of bursitis by US, we injected steroid-lidocaine mixture intraarticularly and checked whether the tenderness disappeared after 2~3 minutes. Results: There was no case with bursitis at pes anserinus by US. The tenderness at pes anserinus diminished in 2-3 minutes after the intraarticular injection of the steroid-lidocaine mixture. After 6 weeks follow up, 16 patients(66.7%) had little or no tenderness at pes anserinus. 8 cases had the recurrence of tenderness recurred, 4 cases underwent arthroscopic operation on the meniscal tear, and 1 case underwent total knee arthroplasty. All cases underwent any operations had the tenderness at pes anserinus disappeared. The others 3 cases did not undergo total knee arthroplasty despite of radiologic obliteration of knee joint adequate for Kellgren-Lawrence grade IV. Conclusion: Without the bursitis at Pes Anserinus, patients the osteoarthritis may have the tenderness due to the referred pain.

  • PDF

Extraction of Blood Flow of Brachial Artery on Color Doppler Ultrasonography by Using 4-Directional Contour Tracking and K-Means Algorithm (4 방향 윤곽선 추적과 K-Means 알고리즘을 이용한 색조 도플러 초음파 영상에서 상환 동맥의 혈류 영역 추출)

  • Park, Joonsung;Kim, Kwang Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.11
    • /
    • pp.1411-1416
    • /
    • 2020
  • In this paper, we propose a method of extraction analysis of blood flow area on color doppler ultrasonography by using 4-directional contour tracking and K-Means algorithm. In the proposed method, ROI is extracted and a binarization method with maximum contrast as a threshold is applied to the extracted ROI. 4-directional contour algorithm is applied to extract the trapezoid shaped region which has blood flow area of brachial artery from the binarized ROI. K-Means based quantization is then applied to accurately extract the blood flow area of brachial artery from the trapezoid shaped region. In experiment, the proposed method successfully extracts the target area in 28 out of 30 cases (93.3%) with field expert's verification. And comparison analysis of proposed K-Means based blood flow area extraction on 30 color doppler ultrasonography and brachial artery blood flow ultrasonography provided by a specialist yielded a result of 94.27% accuracy on average.

Prolotherapy for the Lower Extremities (하지에서의 프롤로 치료)

  • Kim, Yong Uck
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.1
    • /
    • pp.37-44
    • /
    • 2009
  • Prolotherapy, the technology for strengthening lax ligaments, has found increased acceptance in recent years. Prolotherapy involves the injection of the irritant solutions into the weakened or stretched ligaments which are a source of chronic pain. This induces an inflammatory response which mimics the normal repair sequence. Various musculoskeletal disorders of lower extremities such as degenerative arthrtitis, ligament and tendon injuries can be treated with prolotherapy. Prolotherapy is a very good, powerful nonsurgical conservative treatment in various musculoskeletal disorders. Ultrasound exam is very useful to find and confirm the exact location of disorders and check the progress in prolotherapy practices.

  • PDF

Ulnar Nerve Subluxation Diagnosed by Dynamic Ultrasonography (동적 초음파를 이용하여 진단한 주관절 척골 신경 아탈구)

  • Ji, Jong-Hun;Jung, Jae-Jung;Kim, Young-Yul;Kang, Hyun-Taek;Park, Sang-Eun;Kim, Dong-Jin
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.2
    • /
    • pp.79-83
    • /
    • 2010
  • Musculoskeletal ultrasonography has been used as a convenient and simple tool for diagnosis of various conditions of orthopaedic diseases for many years. Generally magnetic resonance imaging (MRI) is thought to be the best method to search for anatomical structures or variations. However, for dynamic conditions such as dislocation or subluxation of tendons and nerves, MRI is not superior to ultrasonography, especially dynamic ultrasonography. So we present such a patient with an ulnar nerve subluxation at the elbow who has symtoms mimicking cubital tunnel syndrome diagnosed by dynamic ultrasonography and treated successfully by ulnar nerve anterior transposition and think that dynamic ultrasonography is a useful method for diagnosing dynamic condition such as ulnar nerve subluxation mimicking cubital tunnel syndrome.

  • PDF

Ultrasound-Guided Shoulder Injections (초음파 유도하 견관절 주사요법)

  • Moon, Young Lae;Jun, Yong Cheol;Sun, Jae Myeong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.393-401
    • /
    • 2019
  • The shoulder pain is one of the most common problems to orthopaedic surgeons in clinic. Among therapeutic modality used to manage this pain, joint and periarticular injection, as well as suprascapular nerve block, show good clinical outcome. Ultrasound guidance is a safe technique, increasing the safety and accuracy of the procedure and reducing complications. An accurate understanding of the surface anatomy is important in performing the ultrasound-guided shoulder injections. This article aims to describe the surface anatomy and sono anatomy of both the shoulder and the surrounding structures and also summarize different infiltration techniques and peripheral nerve blocks.

The study on Development and characteristic of ultrasound biopsy training phantom of breast (유방 초음파 팬텀의 제작과 특성에 관한 연구)

  • Ma, Sang-Chull;Kong, Young-Kun;Ahn, Young-Man
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.19-24
    • /
    • 2003
  • We carried out studies on development and characteristic of ultrasound brast training biopsy phantom. the major finding were of follow ; (1) C type TMM was shown good homogeneity, brightness and attenuation as like human soft tissue. (2) $TiO_2$ 4.10%w/v TMM was shown good homogeneous echo texture and propagated speed as like the human Tissue. (3) $TiO_2$ type TMM was appeared lower brightness and higher penetration rate than C type TMM. Therefor, Breast TM phantom and target material TMM will be useful $TiO_2$ 4.10 %w/v TMM and C 2.09 %w/v TMM.

  • PDF

Comparative Evaluations of Magnetic Resonance Image, Spiral Computed Tomography and Ultrasound in the Diasnosis of Experimental Diaphragmatic Rupture in the Rabbit (토끼의 횡격막 파열 진단에 있어서 자기공명영상, 나선형전산화단층촬영 및 초음파의 가치 비교)

  • 김학희;정승은;이배영;최병길;신경섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.154-161
    • /
    • 1997
  • Purpose: Traumatic rupture of the diaphragm is not easy to diagnose and often delayed. Delayed diagnosis of diaphragmatic rupture accompanied by higher chances of strangulation of herniated viscera which may result in higher morbility and mortality. The purpose of this study was to evaluate diagnostic accuracy of spiral CT, MRI and US for the diagnosis of diaphragmatic rupture in an animal model. Materials and Methods: Small, medium, and large sized transabdominal diaphragmatic ruptures were surgically made in experimental rabbits and then followed up with spiral CT, MR!, and US at 1 day, 3 day, and 1 week after operation. Results: US was superior to MR! or spiral CT in diagnosis of diaphragmatic rupture(P(0.05). The sensitivity and specificity were 94.4% and 92.9% for US, 54.0% and 85.7% for MRI, and 46.0% and 78.6% for spiral CT, respectively. The size of laceration was not related to diagnostic sensitivity in US. Sensitivity of MRI and spiral CT increased as the size of laceration were larger, but no statistical significance was present(P>0.05). All experimental animals developed pleural effusion or hemothorax one day after operation. In acute phase, US and MRI were more sensitive than spiral CT in detecting diaphragmatic rupture. Spiral CT was more sensitive than US and MRI in delayed phase but without statistical significance(P>0.05). In the experimental rabbits with accompanying visceral hernia through the diaphragmatic defect, diagnostic accuracy was found equally high among three image modalities(P>0.05). Conclusion: This study indicates that US is the most accurate diagnostic method in detecting injury to the diaphragm in a rabbit model. The findings obtained in this experimental study can be applied to the diaphragmatic rupture of human being.

  • PDF