• Title/Summary/Keyword: 초음파가진

Search Result 271, Processing Time 0.027 seconds

A Study on Motion Characteristics of the Ultrasonic Transporting System according to the change of Flexural Beam Shape (Flexural Beam의 형태 변화에 따른 초음파 이송시스템의 동작특성에 관한 연구)

  • 정상화;신병수;차경래
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.696-699
    • /
    • 2003
  • In the semiconductor and the optical industry a new transport system which can replace the conventional sliding system is required. There systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system can solve these problem. In this paper, the object transport system using the excitation of ultrasonic wave is proposed. The experiments for finding the optimal excitation frequency, finding phase-difference between two ultrasonic wave generators are performed. The relationship of transporting speed according to the change of flexural beam shape is verified and the system performance for practical use is evaluated.

  • PDF

초음파 진동 절삭 공구 혼(tool horn)설계에 관한 연구

  • 강종표;송지복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.39-45
    • /
    • 1991
  • 최근 진동 절삭 가공 및 용착 등에 초음파 진동을 동력적으로 응용하려는 시도가 급증하고 있다. 이 분야에서는 진동자에서 발생되는 미소한 진폭의 적은 초음파 에너지를 큰 에너지로변환시키는 방법으로서 진동자의 끝단에 진동자와 동일한 진동수의 고유진동수를 가진 부스터와 tool horn을 부착하여 공진에 의해 진폭의 증폭으로 큰 에너지를 얻고 있다. 그러나 부스터와 tool horndml의 고유 진동수가 진동자의 진동수와 일치하지 않을 경우에는 tool horn 의 끝단에 진동이 전달되지 않는 결과를 초래하게 된다. 본 연구에서는 유한 요소법을 이용하여 축대칭 및 3차원 형상의 tool horn에 대한 고유 진동수 계산 퍼스널 컴퓨터만으로도 tool horn을 설계할 수 있도록 하여 이 결과를 실용 tool horn 설계 제작에 손쉽게 이용할 수 있도록 하였다.

Development of the object transport system using 2-Mode ultrasonic wave excitation (2-Mode초음파 여기 물체 이송 시스템 개발에 관한 연구)

  • 정상화;신병수;차경래
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.956-959
    • /
    • 2003
  • In the semiconductor and the optical industry a new transport system which can replace the common system is required. The common systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system solve these problem. In this paper the object transport system using the excitation of ultrasonic wave is proposed. The experiments for finding the optimal excitation frequency, finding phase-difference between two ultrasonic wave get orators are performed. The effect of transporting speed according to the change of weight and amplification voltage are verified. In addition, the system performance for actual use is evaluated.

  • PDF

Measurement Method of Deep Cervical Flexors from Cervical Ultrasound Images (경추 초음파 영상에서의 심부 경부 굴곡근 두께 측정 방법)

  • Kim, Kwang-Baek;Hong, Dong-Jin
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2012.07a
    • /
    • pp.35-38
    • /
    • 2012
  • 본 논문에서는 경추 초음파 DICOM 영상에서 심부 경부 굴곡근의 하단 후보 경계선을 이용하여 경추가 위치하는 후보 영역을 추출한다. 추출한 경추 후보 영역에 퍼지 시그마 이진화 기법을 적용하여 경추 객체를 추출한다. 심부 경부 굴곡근의 두께를 측정하기 위한 측정 기준점을 정확하게 추출하기 위해 심부 경부 굴곡근의 하단 경계선의 위치 정보를 이용하여 심부 경부 굴곡근내의 지방이 경추 객체로 추출되는 문제점을 개선하고, 개선된 영상에서 경추 객체들이 가진 픽셀 좌표를 이용하여 측정 기준점을 설정한다. 그 후, 객체들의 위치 정보를 이용하여 측정 기준점을 다시 설정한다. 심부 경부 굴곡근 영역과 측정 기준점을 이용하여 심부 경부 굴곡근의 두께를 측정한다. 제안된 방법을 경추 초음파 DICOM 영상에 적용하여 심부 경부 굴곡근의 두께를 측정한 결과, 기존의 심부 경부 굴곡근 두께 측정 방법보다 정확한 결과를 얻을 수 있는 것을 확인하였다.

  • PDF

Novel Analysis Algorithm of Fatty Liver using statistical feature vector from Ultrasound image (초음파 영상의 통계적 특징 벡터를 활용한 지방간 분석 알고리즘)

  • Ha, Soo-Hee;Yoo, Jae-Chern
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.05a
    • /
    • pp.556-558
    • /
    • 2019
  • 기존 초음파 지방간 분석은 Hepatorenal sonographic index(HI)를 사용하여 지방간을 진단하여 왔다. 이러한 HI 기법에서는 Hepato(간)과 Renal(신장), 두 부분의 영상데이터를 비교 활용하였다면, 본 논문에서는 신장의 영상데이터만을 이용하여, 이의 통계적 특징 벡터만을 활용하여 지방간을 진단을 함으로서 기존의 HI기반 분석대비 편리성과 정확도를 개선코자 Kidney Index(KI) 기반의 분석 기법을 제안한다. 본 논문에서 제안된 KI는 정상간과 지방간을 가진 실제 환자의 초음파 사진(정상간, 지방간 각 30명)을 학습 데이터를 구성하고, 이들 데이터군으로부터 특징 벡터들을 선별하여 머신러닝 기법 중 서포트 벡터 머신(Support Vector Machine)을 통해 학습시켜, 제안된 알고리즘의 유효성을 입증하였다.

Development of Ultrasonic Testing Method for Evaluation of Adhesive Layer of Blaster Tube (토출관 접합계면 평가를 위한 초음파 시험법 개발)

  • Kim, Y.H.;Song, S.J.;Park, J.S.;Cho, H.;Lim, S.Y.;Yun, N.G.;Park, Y.J.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.2
    • /
    • pp.46-53
    • /
    • 2004
  • Ultrasonic testing method has been developed to evaluate flaw of adhesive layers in blast tube for the reliability of the rocket nozzle. The ultrasonic reflection from the interface between the steel sheet and the epoxy adhesive is measured with a high-frequency Pulse-echo setup in order to identify contact debonding and missing adhesive in epoxy layer between steel and FRP layers. The steel sheet is resonated by low-frequency ultrasound, and the gap size underneath the measuring location is estimated from the resonance responses. For practical application in industry an automated testing system has been developed where the proposed approach is implemented. The performance of the proposed approach has been verified by actual measurement of gap sizes from the cross-sections of cut specimens using an optical microscope.

Development of ultrasonic testing method for the evaluation of adhesive layer of blast tube (토출관 접합계면 평가를 위한 초음파 시험법 개발)

  • Kim, Y.H.;Song, S.J.;Park, J.S.;Cho, H.;Lim, S.Y.;Yun, N.G.;Park, Y.J.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.230-237
    • /
    • 2003
  • Ultrasonic testing method has been developed to evaluate adhesive layers in blast tube for the reliability of the rocket. The main objective of the present work was to find debonding and missing adhesive in epoxy layer between steel and FRP layers. In this approach, the ultrasonic reflection from the interface between the steel sheet and the epoxy adhesive is measured with a high-frequency pulse-echo setup in order to identify contact debonding and missing adhesive. Then, the steel sheet is excited to resonance by low-frequency ultrasound, and the gap size underneath the measuring location is estimated from the resonance responses. For practical application in industry an automated testing system has been developed where the proposed approach is implemented. The performance of the proposed approach has been verified by actual measurement of gap sizes from the cross-sections of cut specimens using an optical microscope.

  • PDF

Design of Micro-meter Position Driver for X-Y Stage Using Linear Ultrasonic Motor (리니어 초음파 모터를 이용한 X-Y stage의 마이크로 미터급 위치 구동회로 설계)

  • Kim, Jeong-Do;Hong, Chul-Ho;Kim, Dong-Jin;Ham, Yu-Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.2
    • /
    • pp.165-171
    • /
    • 2005
  • The ultrasonic piezo motor is a new type motor that has an excellent performance and many useful features that electromagnetic motors do not have. But, it suffers from severe system non-linearities and parameter variations especially during speed control. Therefore, it is difficult to accomplish satisfactory control performance by using the conventional PID controller. In this paper, to achieve the precise control for linear type ultrasonic motor was analyzed as a function of response time and change with a driving time. Also, we propose controller that combines STEP controller and PD controller that have error of ${\mu}m$ about liner type ultrasonic motor.

  • PDF

Piezoelectric Polymer Ultrasound Transducers and Its Biomedical Applications (압전고분자 초음파 트랜스듀서와 생의학적 응용)

  • Ha, Kang-Lyeol;Cao, Yonggang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.585-596
    • /
    • 2012
  • PVDF(poly vinylidene fluoride) and P(VDF-TrFE)(poly vinylidene fluoride-tetrafluoroethylene) are the typical piezoelectric polymers with unique properties. Even they are inferior to conventional piezoelectric ceramics PZT in electromechanical conversion efficiency and interior loss, though they are superior in receiving sensitivity and frequency bandwidth. Their acoustic impedances are relatively close to water or biological tissue and it is easier to make thin film than other piezoelectric materials. Futhermore, the film is so flexible that it is easy to attach on a complex surface. Those properties are suitable for the ultrasound transducers which are useful for medical and biological application, so that various types of polymer transducers have been developed. In this paper, several important considerations for design and fabrication of piezoelectric polymer transducers were described and their effect on the transducer performance were demonstrated through the KLM model analysis. Then, it was briefly reviewed about the structures of the polymer transducers developed for obtaining images as well as the characteristics of the images in several important medical and biological application fields.