• Title/Summary/Keyword: 초기동결

Search Result 229, Processing Time 0.036 seconds

Pore Structures and Mechanical Properties of Early Frost Damaged Concrete using Electric Arc Furnace Slag as Aggregate (초기동결 피해를 받은 전기로 산화 슬래그 혼입 콘크리트의 공극 구조 및 역학적 특성)

  • Lee, Won-Jun;Choi, So-Yeong;Kim, Il-Sun;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.68-77
    • /
    • 2020
  • The purpose of the paper is to evaluate the pore structure and mechanical properties of early frost damaged concrete using electric arc furnace slag as aggregate. From the results, when the concrete is exposed to frost damage at an early age, the peak point of pores 100 to 150 ㎛ in diameter were transferred into larger one. When the freezing duration is not exceeded 24 hours, it is possible that the pore distribution of under the 200 ㎛ is maintained and pore size of over 500 ㎛ is not formed, and, the freezing resistance of concrete using EFG could be improved. When BFS was mixed in concrete using EFG as coarse aggregate, the relative strength is higher than that of natural coarse aggregate. Meanwhile, the elastic modulus and resonance frequency did not change significantly due to the early frost damage as compared with the compressive strength. So, it is necessary to analyze the correlation between the experimental results in order to evaluate the performance degradation due to early frost damage.

An Experimental Study on Strength Properties of Concrete Using Blast-Furnace Slag Subjected to Freezing at Early Age (초기재령에서 동결을 받은 고로슬래그 콘크리트의 강도발현특성에 관한 실험적 연구)

  • Choi, Sung-Woo;Ban, Seong-Soo;Ryu, Deuk-Hyun;Choi, Bong-Joo
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.43-51
    • /
    • 2003
  • Recently, to consider financial and constructive aspect usage of Admixture such as Blast-Furnace Slag and Fly-Ash, are increased. Also the use of cold-weather-concrete is increased. Blast-Furnace Slag, a by-product of steel industry, have many advantage to reduce the heat of hydration, increase in ultimate strength and etc. But it also reduces early-age strength, so it is prevented from using of Blast-Furnace Slag at cold-weather-concrete. In this study, for the purpose of increasing usage of Blast-Furnace Slag at cold-weather-concrete, it is investigated the strength properties of concrete subjected to frost damage for the cause of early age curing. The factors of this experience to give early frost damaged were Freezing temperature(-1, -10, $-15^{\circ}C$), Early curing age(0, 12, 24, 48hour), Freezing times(0, 12, 24, 48hour). According to this study, if early curing is carried out before haying frost damage, the strength of concrete used admixture, subjected to frost damage, is recovered. And that properties are considered, the effect of using admixture like blast-furnace-slag, is very high

Volatile Retention during Freeze Drying of Fruit Juices (과실쥬스의 동결건조 중 휘발성분 보유력)

  • 심기환;최진상;주옥수;강갑석
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.19 no.6
    • /
    • pp.555-564
    • /
    • 1990
  • The headspace gas chromatographic(analytical) technique was used to evaluate the retention of volatiles in fruit juices during freeze drying as a function of freezing rate, the content of initial solid and chamber pressure. The effects of freezing rate and drying time on the volatile retention under the experimental conditions were marked, particulary at long freezing time. The retention of volatiles in the freeze dried was largely affected by the freezing rate. The highest volatile loss under the freeze drying conditions was observed during the first stage of drying. The behavior during freeze drying of the volatile substances was affected by high content of initial solid. The volatile retention was higher in quick freeze drying than slow freeze drying and low pressure than high.

  • PDF

Studies on the Freezing Time Prediction and Factors Influencing Freezing Time Prediction (식품의 동결시간 예측 및 동결시간에 영향을 미치는 요인에 관한 연구)

  • Kong, Jai-Yul;Jeong, Jin-Woong;Kim, Min-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.827-833
    • /
    • 1988
  • The objectives of this investigation were to develop an improved analytical method and to review with respect to experimental parameters and thermo-physical properties influencing the freezing time prediction. The results indicate that the relationship between freezing time and product size is dependent on the surface heat transfer coefficient. As the magnitude of surface heat transfer coefficient decreases, the influence of product size on freezing time becomes more profound. But the freezing time does decrease slightly as the coefficients are increased to values greater than 150 $w/m^2^{\circ}C$. In addition, influence of thermo-physical properties on the freezing time prediction shown generally density, water content, specific heat and thermal conductivity, in order of % difference. Multiple linear regression equation for freezing time prediction were obtained with respect to 4 different food materials with varying thickness.

  • PDF

SOLIDIFICATION OF AQUEOUS BINARY SOLUTIONS SA TURA TED PACKED BED FROM ABOVE (다공성물질이 충전된 수용성 혼합용액의 동결거동에 관한 실험 연구)

  • 최주열;김병철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.16 no.3
    • /
    • pp.42-50
    • /
    • 1992
  • 다공성 물질이 충전된 밀폐용기 내에서 수용성 이원혼합용액($H_2O{+}NaCl$)이 수평한 상부전열면으로 부터 동결될 때 혼합용액의 초기농도, 액체의 과열 및 다공성물질의 입자직경 크기가 온도와 농도분포에 미치는 영향을 실험하였으며, 동결이 진행됨에 따라 이동하는 고액상 혼합영역의 계명위치를 측정하였다. 다공성물질은 평균직경이 2.85mm, 6mm인 구형의 유리구슬을 이용하였다. 수용성 혼합용액의 초기농도는 공융농도도 이하로 하였으며 상부 전열면은 공융온도 이하로, 하부전열면은 액상선온도 이상으로 유지하여 동결 실험한 결과 상부 전열면으로 부터 고체 영역, 고액상혼합영역, 액체영역으로 구분되었다. 액체의 초기농도가 5%인 경우 과냉현상이 관찰되었으나 10%, 15%인 경우 액체온도는 액상선 온도보다 더 높았다. 용액의 초기농도를 감소시킬수록 고체와 고액상혼합영역의 범위는 증대되었으며 고액상혼합영역과 고체영역의 계면은 더욱 강해진 자연대류에 의하여 2차원성이 증가된 형상을 보였다. 용액의 자연대류는 다공성물질의 직경이 클수록 증가되었으며 계면에서의 제융해현상은 관찰되지 않았다.

  • PDF

Strength Development and Freeze-Thaw Resistance of Concrete Incorporating High Volume Blast-Furnace Slag Subjected to Initial Frost Damage (초기동해를 받은 고로슬래그 다량 혼입 콘크리트의 강도발현 및 동결융해 저항성)

  • Koh, Kyung-Taek;Ryu, Gum-Sung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.79-87
    • /
    • 2011
  • Concrete incorporating high volume blast-furnace slag placed in cold weather regions might be in danger of initial frost damage because dependently on the mix proportions, the setting and the hardening would be remarkably delayed. Therefore, this study investigated to effect of the degree of frost on the strength development and the resistance to freezing and thawing of the concrete incorporating blast-furnace slag when being subjected to freeze at early age. As the experimental results, the concrete incorporating blast-furnace slag attacked by initial frost damage showed the remarkable reduction of both the compressive strength development and the resistance to freezing and thawing. Especially, the resistance to freezing-thawing of the concrete incorporating high volume blast-furnace slag became much lower than that of the normal concrete.

  • PDF

An Experimental Study on Freezing Behavior of NaCl and Heavy Metal Aqueous Solution Using Freeze Concentration Method (동결농축법을 이용한 염수 및 중금속 수용액의 동결거동에 관한 실험 연구)

  • Kim, Jung-Sik;Lim, Seung-Taek;Oh, Cheol
    • Journal of Navigation and Port Research
    • /
    • v.37 no.2
    • /
    • pp.129-135
    • /
    • 2013
  • Recently, waste water treatment system is developed in small and middle size to get more economic advantage. Freeze concentration system has high thermodynamic efficiency and low energy consumption, can re-use purified water and cold energy obtained from ice. This study was experimentally performed to investigate pollution containment in frozen layer by cooling wall temperature, air-bubble flow methods, initial ice-lining thickness of frozen layer in NaCl aqueous solution and the representative heavy metals, Pb and Cr aqueous solution. As the result, a decrease in the cooling wall temperature bring a higher growth rate of ice front and the more solute was involved in frozen layer. The method to inject directly air-bubble into ice-liquid interface through ring shape nozzle gave high purity of ice compared to indirect method. Ice lining in 5mm thickness resulted in frozen layer with higher purity than 1mm thickness.

Changes in Quality of Spray-dried and Freeze-dried Takju Powder during Storage (분무 및 동결 건조 탁주 분말의 저장 중 품질변화)

  • Jeong, Jin-Woong;Park, Kee-Jai;Kim, Myung-Ho;Kim, Dong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.4
    • /
    • pp.513-520
    • /
    • 2006
  • Spray-dried (SD) and freeze-dried (FD) takju powders were stored at 5, 15 and $25^{\circ}C$, and various quality characteristics such as moisture, amino nitrogen, color value, total viable cell count, total sugar, reducing sugar organic acid, and flavor compounds were measured for 50 days at 10-day intervals. After 50 days of storage, the moisture content was increased from an initial 6.64% to 7.24-7.38% in the SD powder, and from an initial 4.86 to 5.43-5.61% in the FD powder. pH, total acid content and total viable cell counts were slightly increased. Organic acid content was decreased in the SD powder from an initial 3,949.9 mg% to 805.9-922.3 mg%, and in the FD powder from an initial 5,171.5 mg% to 3,646.0-4,110.2 mg%. Amino nitrogen content was increased in the SD powder from an initial 1.2% to 1.9-2.2% and in the FD powder from an initial 1.9% to 2.2-2.5%. Total sugar and reducing sugar contents were increased in the SD powder from an initial 17.2% and 4.0% to 25.9-27.3% and 5.8-6.9%, and in the FD powder from an initial 19.1% and 5.2% to 29.2-30.2% and 8.3-8.8%, respectively. With increasing storage time, L and b values in the SD powder increased slowly, while L value in the FD powder tended to decrease and b value tended to increase. About 20 major volatile flavor components were identified in the SD and FD powders by GC-MS and all such component levels were decreased with increasing storage time.

Effect of Initial Freshness of the Japanese Spotted Mackerel on Freezing Storage of the Fish (점고등어의 초기선도(初期鮮度)가 동결저장(凍結貯藏)에 미치는 영향(影響))

  • Park, Chan-Sung;Choi, Kyoung-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.15 no.3
    • /
    • pp.213-221
    • /
    • 1986
  • Japanese spotted mackerels(Scomber tapeinoephalus) were stored at $0^{\circ}C$ for 7days as the maximum, and then, they were stored again at $-3.5^{\circ}C$(partial freezing) or $-20^{\circ}C$(freezing), respectively. During storage by partial freezing, the fishes with a longer period of prestorage at $0^{\circ}C$ showed an earlier increase in the number of bacterial cells on their skin, however, it was not apparent in the freezing storage. K value of the fishes with 7 days of prestorage increased from 20% to 65.4% for 36 days of partial freezing storage, that of the fishes prestored for 0 and 4 days were 39.9% and 53.2% respectively. On contrastly, no drastic increase in K value was observed in the fishes of freezing storage. Content of volatile nitrogen of the fish muscle prestored for 4 days gradually increased from 10mg% to 29.4mg% and 17.2mg% during 36 days of partial freezing and 83 days of freezing storage respectively, that of the fishes with 7 days of prestorage showed no significant increase, moreover, it was decreased within early period of both of the storages. Free drip from the fishes with partial fleering was higher almost 5 times than that from the fishes with freezing, the highest free drip was observed from the fishes with 4 days of prestorage.

  • PDF

A Experimental Study on Waste Water Concentration by Separating Method of Freezing (동결분리방법을 이용한 폐수농축에 관한 실험적 연구)

  • Kim, Jung-Sik
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.51-52
    • /
    • 2006
  • This study was progressed on the freezing behavior of waste water in relation to freeze concentration method useful to waste water treatment system of small and middle size and which can re-use purified water. The object of this experiment is comparing a pollutant contain of the frozen layer and of an aqueous solution by cooling wall temperature, a flow field effect and a initial thickness of frozen layer.

  • PDF