• Title/Summary/Keyword: 초기균열하중

Search Result 189, Processing Time 0.028 seconds

Flexural Experiments on Reinforced Concrete Beams Strengthened with SHCC and Special Reinforcements (SHCC와 특수 보강근으로 보강된 철근콘크리트 보의 휨 성능 실험)

  • Chang-Jin Hyun;Ji-Seok Seo;Yun-Yong Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.46-53
    • /
    • 2023
  • In this paper, we evaluated the flexural performance of three types of reinforced concrete beams (SHCC-RB, SHCC-SB, SHCC-FRP) strengthened with ordinary steel rebar, very high strength (super strength) rebar, and FRP bars together with strain-hardening cement composite (SHCC). For this purpose, a series of beam specimens were manufactured and four-point load bending experiments were performed. As a result of the experiment, all specimens strengthened with SHCC exhibited tightly controlled flexural microcrakcs with the crack width of less than 100 ㎛. This is mostly due to the material properties of SHCC showing tensile strain hardening properties with multiple microcracks under uniaxial tension. The specimen SHCC-FRP showed lower initial cracking moment and yield flexural strength than SHCC-RB, whereas the maximum flexural strength of SHCC-FRP was superior to that of SHCC-RC. This is because the tensile strength of FRP bars is higher than that of ordinary steel reabr. The initial cracking moment of the beam specimen SHCC-SB was similar to that of SHCC-RB, but the yield flexural strength and maximum flexural strength of SHCC-SB were evaluated to be the highest.

Constitutive Law of Reinforced Concrete Subjected to Biaxial Tension (2축 인장을 받는 철근콘크리트의 구성방정식)

  • Cho, Jae-Yeol;Kim, Nam-Sik;Cho, Nam-So;Choun, Young-Sun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.69-77
    • /
    • 2003
  • One directional and biaxial tension tests of 13 reinforced concrete panels were conducted to derive a constitutive law of concrete. Based on the test results, a model equation is derived for the stress-strain relationship of concrete in tension. Main test variables are reinforcement ratio and the load ratio applied in two directions. In addition a failure envelope of concrete in tension-tension region is suggested based on the initial crack occurrence. Test results show that the concrete carries substantial tensile stress even after cracking occurrence. However, the application of this proposed stress-strain relationship for concrete is limited to the case where the direction of reinforcement coincides with the direction of the applied principal stresses.

Evaluation on Shear Performance of the Dapped Ends of Precast Gerber′s U-Beams (프리캐스트 게르버 U형보의 댑 전단 거동평가)

  • 박현석;유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.492-502
    • /
    • 2002
  • The dapped ends of the Gerber's beam were designed by PCI(Prestressed Concrete Institute) and CPCI(Canadian Prestressed Concrete Institute) methods. The depths of nibs with precast and topping concrete, which were halves of the total beam depth, were 77 cm md 18.2 cm, respectably. Shear tests were performed on four full scale beam ends. All specimens designed by PCI and CPCI methods showed crackings at the re-entrant coner of dap before the 32 % of full service design loading, and failed at the load level higher than their design strength but less than their calculated nominal strength. The specimens with increased hanger reinforcement show more effective in development of initial crackings, more ductile in failure with distributed crackings, and failed in higher strength than those of PCI requirement. The tested specimens designed by CPCI method were more ductile in failure than those of the PCI methods.

A Study on the Fatigue Reliability of Structures by Markov Chain Model (Markov Chain Model을 이용한 구조물의 피로 신뢰성 해석에 관한 연구)

  • Y.S. Yang;J.H. Yoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.2
    • /
    • pp.228-240
    • /
    • 1991
  • Many experimental data of fatigue crack propagation show that the fatigue crack propagation process is stochastic. Therefore, the study on the crack propagation must be based on the probabilistic approach. In the present paper, fatigue crack propagation process is assumed to be a discrete Markov process and the method is developed, which can evaluate the reliability of the structural component by using Markov chain model(Unit step B-model) suggested by Bogdanoff. In this method, leak failure, plastic collapse and brittle fracture of the critical component are taken as failure modes, and the effects of initial crack distribution, periodic and non-periodic inspection on the probability of failure are considered. In this method, an equivalent load value for random loading such as wave load is used to facilitate the analysis. Finally some calculations are carried out in order to show the usefulness and the applicability of this method. And then some remarks on this method are mentioned.

  • PDF

Crack Detection of Concrete Using Fiber Optic Cables (Fiber Optic Cable을 이용한 콘크리트 균열탐사)

  • Cho, Nam-So;Kim, Nam-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.157-163
    • /
    • 2007
  • Crack detection technique for concrete structures has been developed in this study. Experimental tests were carried out to detect a surface and internal crack, employing common fiber optic cables and OTDR(optical time domain reflectometry), an optical signal analyzer which is widely used to detect damages at fiber optic cables in the field of optical engineering. While initial concrete crack is ready to occur under cracking force, the occurrence and location of the crack are simultaneously detected to give the same damage to fiber optic cables which have been attached to and/or embedded into concrete in advance. It is obtained through successive tests that the principal factors for crack detection is the covering state of fiber optic cable, and total 4 tests including a preliminary test were conducted and the crack detection technique was verified. The practical usefulness would be expected at crack management and maintenance of concrete structures.

Joint Behavior of Concrete Pavements Using Joint Crack Inducer (줄눈균열 유도장치를 사용한 콘크리트 포장의 줄눈거동)

  • Park, Moon Gil;Choi, Ki Hyo;Nam, Young Kug;Jeong, Jin Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1D
    • /
    • pp.57-65
    • /
    • 2008
  • Joint of concrete pavement contributes to improvement of pavement performance by preventing occurrence of random cracking due to drying shrinkage and temperature changes of concrete slabs at early age. However, saw-cutting operations performed prior to sufficient concrete hardening develop micro-cracking of the concrete near the joints, which may develop to long-term distresses due to repetitious traffic and environmental loadings. To reduce the distresses, the joint crack inducers with heights of 100 mm, 150 mm, and 220 mm and the joint cracking slots with various depth were installed at a test section to investigate occurrence of the joint cracks and their behaviors over 5 months. As the results, higher efficiency of the crack inducing and larger behavior of the joint cracks were observed for the taller joint crack inducer. Higher efficiency of the crack inducing and improvement of the joint performance are warranted by additional investigation and reformation of the joint crack inducer.

Fracture Behavior of Adhesive-Bonded Aluminum Foam with Double Cantilever Beam (접착제로 접합된 이중외팔보 알루미늄폼의 파괴 거동에 관한 연구)

  • Bang, Hye-Jin;Lee, Sang-Kyo;Cho, Chongdu;Cho, Jae-Ung;Choi, Hae-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.521-526
    • /
    • 2014
  • In this study, closed-cell aluminum foam with an initial crack was investigated to produce an axial load-time graph. Using the 10-kN Landmarks of MTS Corporation, a 15-mm/min velocity of mode I shape was applied to the aluminum foam specimen using the displacement control method. ABAQUS 6.10 simulation was used to model and analyze the identical model in three dimensions under conditions identical to those of the experiment. The energy release rate was calculated on the basis of an axial load-displacement graph obtained from the experiment and a transient image of the crack length, and then an FE model was analyzed on the basis of this fracture energy condition. The relation between load and displacement was discussed; it was found that the aluminum foam deformed somewhat less than the adhesive layer owing to the difference in elastic modulus.

A Study on the Fracture Behavior of Composite Laminated T-Joints Using AE (AE를 이용한 복합재료 T 조인트부의 파괴거동에 관한 연구)

  • Kim, J.H.;Ahn, B.W.;Sa, J.W.;Park, B.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.4
    • /
    • pp.277-287
    • /
    • 1999
  • Quasi-static tests such as monotonic tension and loading/unloading tension were performed to investigate the bond characteristics and the failure processes for the T-joint specimens made from fiber/epoxy composite material. Two types of specimens, each consists of two components, e. g. skin and frame. were manufactured by co-curing and secondary bonding. During the monotonic tension test, AE instrument was used to predict AE signal at the initial and middle stage of the damage propagation. The damage initiation and progression were monitored optically using m (Charge Coupled Device) camera. And the internal crack front profile was examined using ultrasonic C-scan. The results indicate that the loads representing the abrupt increase of the AE signal are within the error range of 5 percent comparing to the loads shown in the load-time curve. Also it is shown that the initiation of crack occurred in the noodle region for both co-cured and secondarily bonded specimen. The final failure occurred in the noodle region for the co-cured specimen. but at the skin/frame termination point for the secondarily bonded specimen. Based on the results, it was found that two kinds of specimen show different failure modes depending on the manufacturing methods.

  • PDF

Estimation of Transient Creep Crack-tip Stress Fields for SE(B) specimen under Elastic-Plastic-Creep Conditions (탄성-소성-크리프 상태에서 SE(B) 시편의 천이크리프 균열 선단 응력장 평가)

  • Lee, Han-Sang;Je, Jin-Ho;Kim, Dong-Jun;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.10
    • /
    • pp.1001-1010
    • /
    • 2015
  • This paper estimates the time-dependent crack-tip stress fields under elastic-plastic-creep conditions. We perform Finite-Element (FE) transient creep analyses for a Single-Edge-notched-Bend (SEB) specimen. We investigate the effect of the initial plasticity on the transient creep by systematically varying the magnitude of the initial step-load. We consider both the same stress exponent and different stress exponent in the power-law creep and plasticity to determine the elastic-plastic-creep behaviour. To estimation of the crack-tip stress fields, we compare FE analysis results with those obtained numerically formulas. In addition, we propose a new equation to predict the crack-tip stress fields when the creep exponent is different from the plastic exponent.

Suggestion, Design, and Evaluation of a New Modified Double Tee Slabs (새로운 개량 더블티 슬래브의 제안, 설계 및 평가)

  • Yu, Sung-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.809-820
    • /
    • 2008
  • A new modified full scale double tee slabs with the length of nib plate - 1,500 mm were suggested, designed, and experimentally evaluated up to the loading of flexural failure. This slabs were composed of the tee section which was same to original PCI double tee and the plate section which was modified in a new shape, and the prestressing force was applied at the bottom of tee section only. This specimens were made from the domestic precast factory. The safety and serviceability of the modified nib plate with the dapped ends were evaluated up to the ultimate flexural strength of tee section. As the experimental loading increased, the flexural crackings developed first in the bottom of the slab and they changed to the increased flexural shear and inclined shear crackings in the nib and dapped portion of the double tees. The suggested modified double tee slabs failed in ductile above the design loading with many evenly distributed flexural crackings. The thickness of nib plate - 250 mm does not show any cracking under the service loading and show several minor flexural cracking up to the ultimate state of tee portion. The proposed specimens were satisfied with the strength and ductility requirements in the design code provisions in the tests. Additional experimental tests are required to reduce the depth and tensile reinforcement of nib plate concrete for the practical use of this system effectively.