• Title/Summary/Keyword: 초과 착용

Search Result 18, Processing Time 0.025 seconds

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

Changes in Subjective/Objective Symptoms and the Light Transmissibility of Lens Associated with Overusage of Daily Disposable Circle Contact Lenses in Normal Eyes (일회용 써클소프트렌즈의 초과 착용에 의한 정상안의 자·타각적 증상 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.

The Survey on its Wearing Schedule of Workers Wearing Contact Lens (콘택트렌즈 착용 직장인의 착용시간에 관한 조사)

  • Kim, Ki-Sung;Kim, Sun-Kyung;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.43-49
    • /
    • 2015
  • Purpose: This study was to compare the habitual soft contact lens wear to recommended wearing schedule for subjects and suggest a clinical guideline for prescribing contact lens. Methods: 611 adults (39 men and 572 women) with contact lens experience took part in this study. The survey collected information about current wearing schedule (hours/day and days/week), types of lenses worn and awareness of recommended wear schedule. Results: The subjects wore the daily contact lens for $7.97{\pm}3.60$ hours/day in average. Of these, 247 subjects (40.4%) exceeded the recommended wear schedule and 36 (5.9%) wore for over 15 hours. It turned out that subjects with 3-month extended contact lenses and the ones with the conventional daily wear wore for $9.79{\pm}2.68$ hours and $8.98{\pm}3.30$ hours/day, respectively. For subjects wearing contact lenses longer than five days/week it tended to wear for over 9 hours. Those who were aware of the wear schedule were 293 (48.0%), and those not were 318 (52.0%). 56.7% of subjects who were aware of the wear schedule respected the recommendation whereas only 22.3% of those unaware of it were found to respect it. The possibility to respect the wear schedule was 4.55 times higher when wearers were aware of it. Conclusions: Korean office workers wearing contact lenses wore for $7.97{\pm}3.60$ hours/day. 247 (40.4%) of subjects wore contact lens longer than recommended wear schedule. This implies that it will need to educate contact lens wearer about recommended wear schedule and advice for the long time wearer.

Changes in Centration of Contact Lenses on Cornea and Blink Rate Associated with Overusage of Disposable Lenses (일일 착용 렌즈의 착용기간 초과시 유발되는 렌즈의 중심 안정 위치 및 순목횟수 변화)

  • Park, Mijung;Yang, Jae Heon;Kim, Sun Mi;Park, Sang-Il;Park, Sang Hee;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.51-58
    • /
    • 2008
  • Purpose: This study was assessed to investigate adverse effect induced by overuse of disposable soft contact lenses (CL). Methods: Three disposable lenses (etafilcon A, hilabilcon A, and nelfilcon A) were applied to 19 normal subjects free from any eye diseases for either a single day or variable periods by when subjects complained any discomforts. On the first and last days, localizations of lens' center on corneal surface and blink rates were recorded at every case. Results: Among CL wearers, 10.5% and 47.4% of total subjects quit wearing on the second day and third day, respectively. The case of stopping disposable lens wear was continuously increased with extended hour of lens application. On fourth day, 70.2% of CL wearers reported severe discomforts such as redness, dryness, irritation, pain and blurred vision. When subjects stopped CL wear, decentration of lens from the center of cornea was observed when it compared to the case of single usage of disposable CL. Also about 80% of total subjects showed increased blink rate when CL were worn for more than 2 days. These changes in lens centration and blink rate were consistantly shown regardless of lens types. Conclusions: Blurred vision and acute/chronic discomforts could occur to CL wearers by decentration of lens and increased blink rate when CL were overused more than 2 days even the numbers of two parameters measured in this study were variable by each subject or lens types. Therefore, consideration of individual characteristics and lens types is critical to prevent adverse effects may induced by overusage of disposable lens.

  • PDF

Comparison of Corneal Edema Induced by Material of Contact Lens (콘택트렌즈의 재질별 각막부종의 비교)

  • Kim, Ki-Sung;Kim, Sun-Kyung;Kim, Tae-Hun;Kim, Hyo-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.151-156
    • /
    • 2015
  • Purpose: This study has been compared the degree of corneal edema arising from the material of the lens after wearing the recommended wearing time for the contact lens. Methods: For the study, 43 adults of 77 eyes who did not use drugs and have not any disease participated. Three types of lenses including narafilcon A, HEMA, and silicone hydrogel material regular replaceable lenses were used. Central corneal thickness was measured before and after 8 hours from wearing lenses using Pentacam. The degree of corneal edema was determined by the difference before and after wearing. Results: The average corneal edema of narafilcon A, HEMA material lens, and silicone hydrogel material regular replaceable lens were $2.36{\pm}6.15{\mu}m(Mean{\pm}SD)$, $23.61{\pm}10.71{\mu}m$, $18.25{\pm}8.64{\mu}m$, respectively. The central corneal thickness after wearing narafilcon A was not statistically significant with the central corneal thickness before wearing the lens. Central corneal thickness before and after wearing HEMA material lens and silicone hydrogel material regular replaceable lens were statistically significant. Conclusions: The amount of corneal edema induced by silicone hydrogel material regular replaceable lens was no statistically significant difference to the amount of corneal edema induced by HEMA material lens, but there was significant difference to narafilcon A. Therefore, it is judged to be careful not to exceed the recommended wearing time depending on the composition of the contact lens material.

A Study on Carbon Monoxide and Other Gases During the Fire Test (A-class:1st Rating & B-class:1st Rating) (한국 A급, B급 1단위 화재 시험시 발생하는 일산화탄소 등의 정량적 연구)

  • Jeong, Incheon;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.44-56
    • /
    • 2013
  • This research is to identify how much toxic combustion gases are produced from Korea standardized real fire test (Class A&B) by using Room Corner Tester (RCT) and how much those gases are possibly dangerous to testing personnel by estimating the level of carboxyhemoglobin (% COHb). It is confirmed that testing personnel can be affected as more than 40% COHb from Class A 9th and 10th rating in respiration minute volume (RMV) 2 and from Class A 5th to Class A 10th rating in RMV 3 during the time for initial three minutes. Also, in the case of Class B real fire tests, although it is considered rather safe for the initial 1 minute, testing personnel can be affected as more than 20% COHb from Class B 16th to 20th rating in RMV 3 during total test time. Currently, the Korea standard is only focusing on the protection measures against the heat, but the it is neglecting the protection measures against toxic combustion gases. Therefore, according to this study, it is strongly recommended that testing personnel should wear a self-contained breathing apparatus, or the equivalence depending on the real fire test rating.

Exposure to Styrene in the Lamination Processes with Fiberglass-Reinforced Plastics: Health Diagnosis Case Report (유리섬유강화 플라스틱을 이용한 적층공정 근로자들의 스티렌 노출 평가: 보건진단 사례)

  • Choi, Sangjun;Jeong, Yeonhee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.126-133
    • /
    • 2015
  • 연구목적: 이 연구는 노동부의 보건진단 명령에 의해 유리섬유 강화플라스틱(FRP)을 이용한 이중벽 탱크 제조 사업장의 적층 공정 근로자들을 대상으로 스티렌 노출 특성을 평가하기 위해 수행되었다. 연구방법: 스티렌의 주요발생원 파악을 위해 불포화 폴리에스테르 수지(UPR), 경화제, 조색제, 세척액 등의 원료 내 스티렌 함유량을 가스크로마토그래피 질량분석기(GC-MS)를 이용하여 분석하였다. FRP 적층 공정에 근무하는 작업자들을 대상으로 NIOSH 1501 공정시험법에 의해 공기 중 스티렌 노출 농도에 대한 개인노출 평가를 실시하였고, 생물학적 노출 지표로 뇨 중 만델릭산을 채취한 후 고성능액체크로마토그래피(HPLC)로 분석하였다. 또한 각 직무 특성과 단위작업 중심으로 스티렌에 대한 단시간 노출평가를 수행하였다. 연구결과: 스티렌의 함유량이 가장 많은 주요 원료는 중량비율로37%의 스티렌이 함유된 UPR이었다. 적층 공정의 FRP분무 작업자와 보조 작업자들 모두 스티렌의 8시간 가중평균 노출기준(20 ppm)을 초과하였다. 단시간 노출평가 결과 FRP분무 작업자의 경우 45.9 ppm에서 86.1 ppm 수준으로 FRP를 사용하지 않는 작업보다 통계적으로 유의하게 높은 수준이었다(P<0.01). 가장 높은 수준의 스티렌에 노출되는 단위작업은 FRP를 이용하여 1차 코팅 하는 작업으로 특별한 관리가 필요하였다. 결론: 보건진단을 위해 실시한 이중벽 탱크 제조 사업장의FRP 적층 공정 작업자의 스티렌 노출수준은 노출기준을 초과할 정도로 높은 수준이었다. 그러나 탱크를 천장에 매달고 돌리면서 적층작업을 수행하기 때문에 적절한 국소환기 시스템을 구축하는데 어려움이 있다. 따라서 적절한 방독마스크 착용으로 스티렌 노출 예방이 필요하였다.

Analysis of Microbiological Hazards to Determine S. aureus Contamination Levels at School Foodservice Operations in Gyeonggi Province (경기지역 학교급식에서의 S. aureus 오염도 파악을 위한 미생물 위해분석)

  • Kim, Eun-Jung;Choi, Jung-Hwa;Kwak, Tong-Kyung
    • Korean journal of food and cookery science
    • /
    • v.25 no.3
    • /
    • pp.365-378
    • /
    • 2009
  • This study performed microbiological hazards analysis in raw food materials, cooking processes, kitchen staff, utensils, and the environment in order to obtain contamination levels of S. aureus in school foodservice operations. S. aureus was not detected in cooked foods offered by the foodservice operations; however, it was found in raw food materials prior to cooking. In the case of vegetables, S. aureus was detected in washed mung bean sprouts, parboiled mung bean sprouts, and bellflower roots both before and after disinfection, at levels of 2.2, 1.0, 1.0, and 1.0 log CFU/g, respectively. For processed foods, S. aureus was detected in one sample of packaged bean curd as well as in mung bean jelly cake at the level of 1.5 log CFU/g. For meat products, S. aureus was detected in beef brisket and chicken at levels of 2.3 and 1.3 log CFU/g, respectively. To determine microbiological hazard data for the hands and gloves of cooking personnel, the staff members were divided into two groups: a group presenting Enterobacteriaceae or coliforms, and another group presenting neither Enterobacteriaceae nor coliforms. The results showed that S. aureus was detected on the hands of staff in each group at levels of 2.0 and 2.1 log CFU/hand, respectively, and at 1.8 and 0.0 log CFU/hand on the gloves of staff in each group, respectively. Among kitchen utensils, as an environmental factor in school foodservice operations, S. aureus was detected on meat knives, mixing bowls, and dish cloths at levels exceeding 1.0 log CFU/hand.

Induced Prism by the Categories of Spectacle Frames (안경테 종류에 따른 유발프리즘)

  • Park, Woo-Jung;Kim, Soo Woon;Hwang, Hae-Young;Yu, Dong-Sik;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.311-319
    • /
    • 2012
  • Purpose: One of the critical aspects on dispensing glasses is to match the center of pupils to the optical center of lenses as the mismatched glasses are able to induce uncomfortable effects called prism which has been known to induce phoria, a main cause for asthenopia in many cases. Therefore, we investigated the induced prism occurred by mismatching centers between the center of pupils and the optical center of lenses. Methods: In this study, total 103 subjects were examined whether the center of pupils and the optical center of lenses are matched in horizontal and vertical directions, and then, the data was categorized into 4 groups based on the structural components of glasses. Total amount of prism was compared to show the effect of the glasses frame on the prism induction, and the value of measured prism was compared with the German RAL-RG 915 regulations. Results: The results in respect to the horizontal component showed that the induced prism was not found in 10.7% of total subjects. 73.8% of total subjects were influenced by induced prism, the range of prism was in a tolerance level. However, the 15.5% of total subjects seemed to be influenced by prism which is out of the criterion of tolerance. In case of vertical component, 23.3% of total subjects showed no effects of prism while early adopting glasses, 54.4% of total subjects showed a little prism effect within the criterion of tolerance, and 22.3% of total subjects showed the prism effect out of the tolerance range. This data indicates that group A and B that are less likely adjustable by fitting induce more prism than group C and D in horizontal and vertical components. Conclusions: In higher refractive error condition, it was found that aligning the optical center of lenses with the center of pupils by pre-fitting of glasses frame minimized prism induction in horizontal and vertical components, which ameliorates ocular fatigue. Therefore, appropriate optometric dispensing through fitting by opticians and precise design about monocular PD and monocular Oh are necessary to improve visual perception.

Finite Element Analysis on the Stress and Deformation Behaviors of a Safety Helmet (안전헬멧의 응력 및 변형거동에 관한 유한요소해석)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.4
    • /
    • pp.27-32
    • /
    • 2009
  • This paper presents the stress and deformation behaviors using the finite element method as a function of the thickness of the helmets without the bead frames on the top of the shell structure. The helmet that would provide head and neck protections without causing discomfort to the user when it was worn for long periods of time should be manufactured for increasing the safety and impact energy absorption. The FEM computed results show that when the impulsive force is applied on the top surface of a helmet, the maximum stress and strain have been occurred around the position of an applied impact force, which may lead to the initial failure on the top surface of the helmet shell. As the helmet thickness is decreased from 4mm to 2mm, the impact energy absorbing rate is radically increased, and the maximum stress of the helmet is increased over the tensile strength, 54.3MPa of the thermoplastic material. Thus, the top surface of the helmet should be supported by a bead frame and increased thickness of the shell structure.

  • PDF