• Title/Summary/Keyword: 초고층 구조

Search Result 418, Processing Time 0.028 seconds

Drift Control of the Structure Using Elasto-Plastic Hysteretic Dampers in High Rise Buildings (탄소성 이력댐퍼를 적용한 초고층 건축물의 변위제어)

  • Park, Ji-Hyeong;Park, Tae-Won;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.851-856
    • /
    • 2007
  • Recently, the matter controlling lateral drift is important in high rise buildings, In particular, seismic control dampers, such as mass damper and hysteretic damper, are emerging in the field of actively reducing drift. But. seismic control dampers have weak points with the lack of quantitative analysis and maintenance of the device. Accordingly, in this study we examine the structural characteristic of Steel Elasto-Plastic Hysteretic Damper, which is needless of maintenance, and then consider the basic conditions in the design and construction of the optimal seismic control effect which uses this device.

  • PDF

Reducing bi-directional response of SDOF building by new type Tuned Liquid Damper (새로운 형태의 동조액체댐퍼에 의한 단자유도 건물의 양방향 응답제어)

  • Lee, Hye-Ri;Min, Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.778-782
    • /
    • 2010
  • 본 논문에서는 TLD와 TLCD를 사용한 하나의 액체 감쇠기를 이용하여 건물의 양방향 응답 제어를 연구하였다. 초고층 건물이 풍하중을 받을때는 풍방향과 풍직각방향으로 진동하여 두 개의 댐퍼를 필요로 한다. 이 논문에서 제안된 댐퍼는 건물의 양방향 응답을 하나의 감쇠기로 제어할 수 있다는 장점이 있다. 이 댐퍼의 TLCD는 건물의 주축방향으로 TLD는 주축으로 직각되는 다른 방향으로 거동을 하게 된다. 실험을 통해 양방향 감쇠기를 사용하여 건물의 양방향 응답제어를 증명하였다. 첫 번째로 양방향 감쇠기에 의한 건물의 응답제어를 알기 위한 진동대 실험을 실시하였다. 진동대 가속도를 입력으로 하고 단자유도 건물의 가속도를 출력으로 하는 전달함수를 통해 결과를 나타내었다. 실험 결과 이 연구에서 제안된 감쇠기는 단자유도 건물의 양방향 응답을 제어하였고, 비틀림 응답도 제어 하였다.

  • PDF

Bending-Torsional Vibration Characteristics of Large Structures Influenced by Coupling Effects (연성효과에 의한 대형 구조물의 굽힘-비틀림 진동특성)

  • 송창용;손충열;송재영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.208-216
    • /
    • 1995
  • 대형선박, 항공기, 초고층 건축물 등은 얇은 박판 형태의 보로 이상화하여 구조 및 진동해석을 수행할 수 있다. 이러한 형태로 이상화한 구조물은 비틀림 강도면에서 매우 취약함을 보이고, 굽힘-비틀림 진동은 단면형상에 따라 연성도가 심화된다. 상하 굽힘 진동은 탄성거동 영역에서 도심과 전단중심이 일치하는 대칭 진동(Symmetric vibration) 현상을 보인다. 그러나, 수평 굽힘 진동은 도심과 전단중심의 차이가 커질수록 즉, 연성도가 높아질수록 비틀림 진동과 복합되어 복잡한 비대칭 진동(Antisymmetric vibration) 현상을 나타낸다. 본 논문에서는 연성효과에 의한 수평 굽힘 진동과 비틀림 진동 현상에 대한 연구를 수행하였고, 진동계산을 위해서 전달행렬법(Transfer Matrix Method)을 사용하였다. 수치계산은 첫번째로, 도심과 전단중심의 차이가 매우 작아 연성도를 무시할 수 있을 정도의 구조물에 대해서 일반적인 수평 굽힘 진동 현상과 비틀림 진동 현상을 연구하였다. 두번째로, 연성도가 매우 심할 경우에 굽힘-비틀림 연성 진동 현상을 Timoshenko 보의 이론과 Vlasov 보의이로네 따라 각각 계산을 수행하였다. 마지막으로, 첫번째와 두번째 구조를 결합한 경우에 대해서 굽힘-비틀림 연성 진동 현상을 연구하였다. 이 경우에 두 구조물의 결합부에서 비틀림 강성과 Warping 강성의 심한 변화로 인한 불연속 경계면이 발생하게 되고 이때의 진동해석을 위해서 보 이론에 기초를 두고 상당히 높은 정확도를 제공하는 Haslum[2] 등과 Pedersen[3]이 제시한 이론을 이용하였다.

  • PDF

Fuzzy Hybrid Control of Semi-active TMD (준능동 TMD의 퍼지 하이브리드 제어)

  • Kim, Hyun-Su;Lee, Dong-Guen
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.433-436
    • /
    • 2009
  • 본 연구에서는 준능동 TMD(STMD)가 설치된 초고층건물의 풍응답을 효과적으로 저감시키기 위한 퍼지 하이브리드제어기법을 제안하였다. 이를 위하여 STMD의 응답저감에 우수한 성능을 보이는 스카이훅(skyhook) 제어기와 구조물의 응답저감에 뛰어난 그라운드훅(groundhook) 제어알고리즘을 사용하였다. 본 연구에서는 두 제어기를 적절히 조합하기 위하여 최적의 가중치를 실시간으로 결정하는 퍼지 하이브리드제어기를 개발함으로써 일반적인 가중합방식의 하이브리드 제어기법의 성능을 개선하였다. 제안된 제어기의 성능을 검토하기 위하여 풍하중을 받는 76층 사무소 건물을 예제구조물로 사용하였다. MR 감쇠기를 이용하여 STMD를 구성하였고 STMD의 제어성능을 평가하기 위하여 TMD 및 ATMD의 성능과 비교하였다. 수치해석을 통하여 STMD의 제어성능이 TMD에 비하여 월등히 뛰어남을 확인할 수 있었다. 또한 퍼지 하이브리드 제어기법을 사용하면 스카이훅 및 그라운드훅 제어기를 효과적으로 조합하여 STMD와 건물의 응답을 동시에 줄일 수 있음을 확인하였다.

  • PDF

Hardness of AlTiN/TiAlN multilayer coatings deposited by Cathodic Vacuum Arc Deposition (음극 진공 아크 증착법에 의한 AlTiN/TiAlN 다층막의 경도)

  • Gwon, O-Jin;Kim, Mi-Seon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.35-35
    • /
    • 2018
  • 물리적 증착법에 의해 제조되는 초고경도 박막은 나노다층과 나노복합 구조가 대표적이며, 본 연구에서는 음극 아크 증착법으로 TiAlN과 AlTiiN 층 조합을 이용하여 나노다층구조를 포함하는 다층막 시편을 제작하였다. 초격자 두께 주기 12.1 ~ 15.6 nm에서 35 ~ 55 GPa의 경도값을 가졌으며, 절삭공구 코팅분야에 적용할 예정이다.

  • PDF

모서리 절단 효과로 인한 사각주상체의 공기력 특성변화 전산해석

  • Hwang, Gyu-Gwan
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.553-558
    • /
    • 2015
  • 교량의 주탑, 초고층빌딩과 같이 세장비가 큰 대형구조물의 경우 풍하중에 취약한 특성을 지니고 있어서 바람에 의해 직각 방향으로 발산 진동하는 갤로핑(galloping) 현상이 발생하게 된다. 구조물의 진동을 억제하려는 방안으로 단면 형상에 변화를 주어 공기역학적 불안정성을 감소시키는 방법이 사용되고 있다. 본 논문에서는 Edison_CFD를 이용하여 모서리 절단부의 비율과 받음각에 따른 공기력 특성에 대한 전산해석을 수행하였다.

  • PDF

Development of Construction Factory for Automated Building Construction System (건축물 시공 자동화 시스템 구축을 위한 건설공장 구조체 개발)

  • Kim, Tae-Hoon;Shin, Yoon-Seok;Cho, Hun-Hee;Kang, Kyung-In;Park, Kwi-Tae
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.163-169
    • /
    • 2008
  • The application of robot technology on construction sites is recognized an effective solution to the problems caused by labor shortage on the construction industry, and relevant studies are being carried out increasingly. Automatic construction system for frames of high-rise building was developed in Japan in 1990's. Practical use o F the system, however, was failed due to inefficiency Now, we are developing economic and practical automatic construction system that is lighter and suitable for building construction In Korea. This study has discussed developing the system of construction factory and climbing control system, which is the core technology of the automatic construction system in Korea.

  • PDF

Experimental Evaluation on the Vibration Control Effect of Tuned Liquid Damper with Embossment (벽면 요철형 동조액체댐퍼의 진동제어성능에 관한 실험적 평가)

  • Ju, Young Kyu;Kim, Dae Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.765-772
    • /
    • 2002
  • Many researchers have studied several vibration control devices such as TMD, TLD, and VED to reduce the acceleration level for tall buildings. Advantages of TLD (tuned liquid damper) include easy installation, low cost, and less maintenance. However, the dynamic characteristics of TLD must be verified by experiment and analysis due to the difficulties in evaluating the characteristics of water sloshing. In this study, free vibration and dynamic excitation experiments of structure with TLD were conducted to verify vibration control force of the proposed TLD for high-rise building. The parameters were mass ratio of water to structure, number of damping nets, and aspect ratio. From the test results, the responses of structure with water tank were observed to be smaller than those of structure alone. Furthermore, better damping effect could be achieved with larger mass ratio, more damping nets, and larger aspect ratio. However, in the case of water tank with no damping net, little damping effect was obtained.

A Study on Integrated Fire Protection System for high-rise Building (초고층빌딩 통합 화재방재시스템 설계 및 구현에 관한 연구)

  • Lee, Jeong-Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.39-47
    • /
    • 2020
  • The fire protection system for high-rise buildings is currently confined to the preparation of sprinklers, emergency stairs, and exit and monitoring systems. On the other hand, an integrated system, including the model with scenario-based actions, is required for effective fire protection. An integrated fire protection system is needed to operate and manage the total cycle of the fire protection. In this study, an integrated fire protection system, which included sensing and consequent processes related to fire emergencies, was designed and implemented. The designed scheme can gather and analyze the data of the production, operation, and consumption patterns as it integrates fire protection systems for fire fighters and evacuating people. The integrated fire protection technology and system, which has target performance with satisfied 1/2 sec transaction response time and 1.2 transactions per second, is expected to contribute to market creation in converged technology-based fire protection fields.

Study on Bearing Capacity of Ultra High Strengh End Extended PHC Pile by Loading Test (재하시험을 통한 초고강도 선단확장 PHC말뚝의 적용성 연구)

  • Hwang, Ui-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.269-275
    • /
    • 2019
  • As the national industry is developing gradually due to the expansion of the economic scale, the construction of large and super high-rise structures for building social infrastructure has been increasing, and studies have been conducted actively to transmit the large loads at the upper portion to the lower bedrock. In this study, the PHC was extended to an ultra-high strength PHC, which increased the concrete compressive strength of the PHC from the conventional 80 MPa to 110 MPa, and the PHC, which extended the tip of the pile. After construction with the driving method and injected pile method, the tendency of the bearing capacity was tested through a load test. Measurements of the bearing capacity of the extended PHC using the pile driving method revealed the main surface friction force to be smaller than that of the general PHC, and the stet-up effect was also insignificant. On the other hand, the effect of the friction force on the ground surface when the injected pile method was applied is expected to increase the bearing capacity when the gap between the main surface and the ground is wide and the cement paste is filled tightly. In addition, the ultrahigh strength PHC showed higher bearing capacity than the conventional PHC, and the permissible pile stress was less than 60%. Therefore, it is possible to reduce the number of piles and reduce the construction cost and effect of shortening the length of the pile by designing the tip of the pile on the ground with the intensity of soft rock as a method for utilizing the increased strength of the ultra-high strength PHC.