• Title/Summary/Keyword: 초고층 구조

Search Result 417, Processing Time 0.034 seconds

Case-Based Reasoning Method Using Case Data Base of Tall Buildings in Korea (국내 초고층 건물의 사례 데이터베이스를 이용한 사례기반추론기법)

  • Song, Hwa-Cheol;Park, Soo-Yong;Kim, Soo-Hwan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.6
    • /
    • pp.75-82
    • /
    • 2007
  • In this study, a design-supporting system, which is intended to assist engineers in the schematic phase of the structural design, is developed using a case database that contains design information of tall buildings in Korea. A case-based reasoning method utilizing the case database is proposed. The inductive retrieval module for selecting structural system, in the initial stage, from the design information of case database for 47 tall buildings is presented. Also, the nearest-neighbor retrieval method for selecting similar design cases is introduced.

  • PDF

Structural Analysis and Towing Test for Predicting Drag Coefficients of a Very High-rise Steel Artificial Reef (초고층 강제어초의 유체력 산출을 위한 예인시험 및 구조해석)

  • Hyun-Kyoung Shin;Ho-Gyun Park
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.38 no.2
    • /
    • pp.44-52
    • /
    • 2001
  • A modeling program was developed in Part I which represents the 3-D geometry, produces bill of material, automatically draws drawings and produces input data for structural analysis of Very High-rise Steel Artificial Reefs(VEHSAR). Model tests were carried out to measure drag forces acted on VEHSAR in the Ocean Engineering Wide Tank, the University of Ulsan and structural analyses were made to simulate structural behaviors of VEHSAR. The integrated package system is suggested to design VEHSAR with different geometries.

  • PDF

A study on the code improvement about the refuge safety area in high-rise buildings (초고층 건축물 피난안전구역 관련 기준의 개선을 위한 개념적 연구)

  • Han, Myung-Sin;Park, Jae-Sung;Choi, Young-Kwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.149-154
    • /
    • 2010
  • 건축기술의 눈부신 발전과 경제적 가치추구 등에 따른 국가 사회적 수요로 인하여 초고층 건축물의 건설물량은 이들 건축물에 대한 효과적인 피난안전대책을 정립하기도 전에 급속히 증가하는 추세이다. 우리나라는 2009년 7월 16일 재정된 건축법 시행령을 통하여 층수가 50층 이상이거나 높이가 200미터 이상인 건축물을 '초고층 건축물'로 규정하고, 이러한 건축물의 피난안전을 위하여 지상층으로부터 최대 30개 층마다 설치하는 대피공간을 '피난안전구역'으로 정의하였다. 이후 2010년 2월 18일 개정령에서는 초고층 건축물의 피난안전구역을 건축물의 '피난층'으로 인정하기에 이르렀다. 그러나 피난대상인원 등에 따른 대피공간의 면적이나 구조 등 내부시설에 대한 설치기준이 없어 피난안전구역으로서의 충분한 신뢰성을 확보하지 못하고 있어 이에 대한 심층적 연구와 기준의 개선이 필요한 실정이다.

  • PDF