• Title/Summary/Keyword: 초고층 구조물

Search Result 204, Processing Time 0.032 seconds

A Column Shortening on High-Rise Building and Structural Effect under seismic load (초고층 건물의 기둥축소와 지진하중에 대한 구조적 영향)

  • 정은호;김희철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.3
    • /
    • pp.59-68
    • /
    • 1997
  • The necessity of a high-rise building in big cities gave a new problem to structural engineers. The shortening effect of vertical members needs special considerstion in the desigh and construction of high-rise buildings. The shortening of each column transfers load to nonstructural members such as partitions, cladding, and M/E systems which are not designed to carry gravity loads. Also, the slabs and beams will tilt due to the cumulative differential shortening of adjacent vertical members. The main purpose of estimating the total shortening of vertical structural members is to compensate the differential shortening between adjacent members. This paper presents the structural effect of differential shortening between in main structural members. Lateral earthquake load is applied to the 52 story concrete structure which has an initial vertical displacement due to the gravity load. Shortening amount for each vertical member was estimated using the computerized column shortening software. Comparison of stresses between the shortening corrected structure and the uncorrecated structure due to earthquake load was discussed.

  • PDF

A Development of BIM Quality Assurance Checklists for Applying Super-tall Buildings (초고층 복합건축물 적용을 위한 개방형 BIM 데이터 품질관리 체크리스트 개발)

  • Kim, In-Han;Cho, Geun-Ha;Choi, Jung-Sik
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.371-374
    • /
    • 2011
  • 본 연구는 개방형 BIM 환경의 품질관리 기준 확보를 목적으로 건설 산업의 공통업무분야와 추가적인 세부업무분야에 대한 품질관리 체크리스트를 제안하고자 한다. 공통업무는 일반적인 목적으로 적용 가능한 설계기준, 시설기준, 시공기준으로 대상을 분류하고, 세부업무는 초고층 건축물의 개방형 BIM적용 및 활용 목적에 따라 피난동선 검토, 에너지 분석 검토 측면으로 대상을 분류하여 각 분야 별 체크리스트를 도출하였다. 도출된 체크리스트가 검증을 통해 실무에 적용되면 BIM 모델의 작성 기준 및 지침과 연계되어 요구되는 조건들을 충족시키는 모델링을 유도하며 BIM 모델의 품질향상의 결과를 가져다 줄 것이라 기대한다.

  • PDF

A comparative study on the behavior of dynamic analysis and pseudo-static analysis considering SSI of a tall building and an adjacent underground structure (초고층 빌딩과 인접 지하구조물의 SSI를 고려한 동적해석과 유사정적해석의 거동 비교 연구)

  • You, Kwang-Ho;Kim, Seung-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.4
    • /
    • pp.671-686
    • /
    • 2018
  • Recently, earthquakes have occurred near Gyeongju and Pohang and the social demands are thus being increased for seismic analysis of tall buildings and their adjacent underground structure in big cities. Since most of the previous seismic analysis studies considered a tall building and an adjacent underground structure separately, however, they lack the analysis on dynamic mutual behavior between two structures. Therefore, in this study, a dynamic analysis with a full soil-structure interaction was performed for a complex underground facility with a tall building and an adjacent underground structure constructed on the bedrock with a surface layer. To improve the reliability, in particular, a pseudo-static analysis was performed and compared with the dynamic analysis results. It is comprehensively concluded that the analysis of adjacent underground structures being considered is more conservative than that of not considered.

Experiments on the Influence of Opening of Natural Smoke Ventilators on the Stack Effect in High-rise Mixed-use Residential Buildings (초고층주상복합건물에서 배연창 개방이 연돌효과에 미치는 영향에 대한 실험적 연구)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Park, Yong-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.89-94
    • /
    • 2009
  • The stack effect in high-rise buildings is expected more significant at nights in winter due to the large temperature difference between the inside and outside of the buildings. However, the existence of large openings such as natural ventilators on the floor may effect the position of neutral plane, smoke spread at fire and thus obstruct the door openings for rescue. In this paper, the vertical and horizontal pressure distribution with different openings of natural smoke ventilators was experimentally analyzed by investigating pressure differentials.

Wind Induced Vibarion Monitoring for High-rise Buildings (초고층건축물 풍진동 모니터링 기술)

  • Choi, Sun-Young;Jo, Ji-Seong;Lee, Jong-In;Kim, Hyun-Bae;Kim, Hong-Jin;Park, Je-Woo;Yu, Eun-Jong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.396-399
    • /
    • 2010
  • 본 논문에서는 실제 건설중인 초고층건물을 대상으로 상시 풍하중을 이용한 풍진동 모니터링을 통해 고유주기와 감쇠비를 예측하고 이를 설계단계에서의 구조해석 및 가정에 의한 고유주기 및 감쇠비와 비교하였다. 이를 위해 시공중 풍진동계측을 실시하여 고유주기와 감쇠비를 측정하고, 시공단계를 고려한 구조해석모델을 통해 고유주기와 감쇠비가 유사하도록 모델을 수정한 후 이를 바탕으로 완공단계에서의 구조해석모델을 재구성하였다. 이 완공단계에서의 구조해석모델을 바탕으로 완공후의 고유주기 및 감쇠비를 예측하고 이를 설계단계에서의 값과 비교하였다. 향후 이러한 실계측 및 분석을 충분히 축적된다면 초고층설계시의 보수적인 가정사항들을 개선시키고, 풍동실험에 의한 풍진동 산정시의 정확성을 크게 향상시킬 것으로 기대된다.

  • PDF

Modified Proposal for Optimal Location of Offset Outrigger System in High-rise Building (초고층 오프셋 아웃리거 구조의 최적 위치에 대한 수정제안)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.37-44
    • /
    • 2020
  • This research aimed to propose the more proper equation than the leading and existing equations to predict the optimum location of offset outrigger. In this study, a 79 existing models of offset outrigger system were examined. And the key factors in the existing offset outrigger models were the stiffness of shear wall and offset outrigger system, the stiffness of exterior column connected in offset outrigger, the frame stiffness, the ratios of lateral stiffness of frame in shear wall-frame structures, and all that. This paper proposed the modified equation of predicting the optimal location of offset outrigger system. Additionally, the findings of this study provided the important structure engineering materials of the optimal offset outrigger position in tall building.

An Introduction to Application of High Strength Concrete for the Construction of High Rise Complex Structure (초고층 주상복합구조물에 적응한 고강도 콘크리트의 사례)

  • Kim, Dong-Seok;Park, Sang-Jun;Won, Cheol;Lee, Sang-Su;Kim, Yeong-Jin
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.54-58
    • /
    • 2002
  • 대도시의 인구집중에 따라 토지의 고도이용을 위하여 건물의 고층화 및 복합화에 대한 요구가 점점 더 높아지고 있으며, 도심지에서의 삶의 질을 윤택하게 하기 위한 방법으로서 조망에 대한 욕구가 더 한층 중요시되고 있다. 이러한 이유로 인해 주거용 아파트에도 초고층 빌딩 개념이 도입되고, 상가 및 커뮤니티 시설 등이 추가되는 주상복합건물의 건설이 증가하는 추세에 있다.(중략)

The Application of Post-tensioned Slab System to Tall Buildings (초고층 건축물의 포스트텐션 슬래브 시스템 적용)

  • Chung, Kwang-Ryang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.879-882
    • /
    • 2008
  • The market of Korea of post-tension system for building is growing up since 2000 and many engineers and construction companies show interest in it. This paper introduces the structure system and construction of post-tension tall buildings including recent trend in the industry of post-tension system for buildings in Korea and the point to be considered when design post-tensioned tall building. Park Polis is composed of two towers of 39 stories with a level to the top of the roof +144m and is currently under construction at Ulsan in Korea. This building designed as the unbonded post-tension floor system and will be the tallest and first high-rise post-tensioned building in Korea. The structural system is composed of the flat slabs, perimeter columns and core walls. At first, this building had designed as regular RC flat slab with perimeter beams. However, floor structure system was reconsidered because the construction company wants to improve efficiency of construction. As a result, the floor system of PARK POLIS re-designed as PT flat slab.

  • PDF