• Title/Summary/Keyword: 초간

Search Result 441, Processing Time 0.026 seconds

A Study on the Sound Amplitude and Decaying Time of the Jing Depending on the Depth of Rim (징악기의 RIM 깊이에 따른 음향 증폭 및 음향 지속 시간에 관한 연구)

  • Sohn Jung-ho;Bae Myung-Jin
    • Journal of Broadcast Engineering
    • /
    • v.9 no.4 s.25
    • /
    • pp.424-433
    • /
    • 2004
  • Jing(gong) is one of the most well known Korean traditional Samulnori instruments to the general public. Samulnori is consisted of four instruments, them being : the jingo the janggu (hour-glass drum). the kkwaenggwari, and the buk(drum). Of the four instruments, the jing with its deep, and yet soft and beautiful long lingering sound embraces the sounds of the other three. The jing is a brassware instrument, a compound of $70{\%}\;copper\;and\;22{\%}\;tin.$\;A high quality brassware is used when the jing is made. The jing is shaped with a 39-40cm circular plate and a rim that gives 7.0-7.5cm of depth to the instrument. Even with its most simple structure, when the circular plate is hit during performance, the rim which supports the circular plate gives resonance to the sound making low-frequency sounds. Therefore the range of the representative frequency of the full rim jing is between $118.4{\~}366.0[Hz],$\;the lingering sound lasts for more than 20 seconds afterwards. When the jing with half of its rim cut off is hit the basic frequency is $139.9{\~}387.5[Hz].$\;And the sound lasted for ten more seconds. The jing of its rimless frequencies are distributed between $990.5{\~}1,372[Hz].$\;And the lingering sound lasts for 5seconds afterwards. Therefore, different thickness and depth of the rim may give new resonance frequencies and alter the longing time of the sound. This thesis paper will try to reveal the relationship between the thickness or depth of the rim (which holds the bending circular plate) and the frequency or the lasting time of the sound.

EFFECT OF DENTIN SURFACE WETNESS ON TENSILE BOND STRENGTH OF SELF ADHESIVE RESIN CEMENTS (상아질 표면 젖음성이 수종 자가접착레진시멘트의 인장접착강도에 미치는 영향)

  • Yoon, Sung-Young;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.113-119
    • /
    • 2009
  • The purpose of this study was to compare the tensile bond strength of several self-adhesive resin cements bonded to dentin surfaces with different wet conditions. Three self-adhesive resin cements: Rely-X Unicem (3M ESPE, St. Paul, MN. USA). Embrace Wetbond (Pulpdent. Oakland. MA. USA). Maxcem (Kerr. Orange. CA. USA) were used. Extracted sixty human molars were used. Each self-adhesive resin cement was adhered to the dentin specimens (two rectangular sticks from each molar) in different wet conditions. Tensile bond strength were measured using universal testing machine (EZ Test. Shimadzu corporation. Kyoto. Japan) at a crosshead speed of 1.0mm/min. After the testing. bonding failures of specimens were observed by Operative microscope (OPMI pro, Carl Zeiss. Oberkochen, Germany). T-test was used to evaluate the effect of dentin surface wetness. One-way ANOVA test was used to evaluate the tensile bond strength of self-adhesive resin cements in the same condition. Scheffe's test was used for statistical analyzing at the 95% level of confidence. The result showed that wetness of dentin surface didn't affect tensile bond strength of self-adhesive resin cements and Maxcem showed the lowest tensile bond strength.

Studies on the browning inhibition of yam(Dioscorea aimadoimo) during hot air dehydration (단마(Dioscorea aimadoimo)의 열풍건조 시 갈변 억제 방안 연구)

  • Chung, Yong-Yul;Jeong, Woo-Sik;Chung, Shin-Kyo
    • Applied Biological Chemistry
    • /
    • v.39 no.5
    • /
    • pp.384-388
    • /
    • 1996
  • This research was conducted to investigate the effective methods for browning inhibition on yam (Dioscorea aimadeimo) during dehydration by physical and chemical pretreatments. Moisture, crude protein, crude fiber and N-free extract contents of yam were 81.17%, 1.43%, 0.29% and 15.81%, respectively. Yams were sliced to 0.5 cm thickness and placed to single and poly layer in plastic tray, and then changes of their weights were measured during air dehydration at $50^{\circ}C,\;65^{\circ}C,\;and\;80^{\circ}C$. The dehydration time reaching to optimum moisture level for the pulverization of the yam slices were 10, 6, 3 hours(single layered) and 12, 7, 5 hours(multi layered) at the respective temperature. To inhibit browning at $80^{\circ}C$ air dehydration, water and steam blanching, microwave treatment effects were investigated on yam slices for 30 sec. and 60 sec. Steam blanching for 30 sec. was comparatively effective to inhibit browning of yam slices. Yam slices were immersed in single and combined browning inhibitor solutions and evaluated for browing degree during dehydration by the values of Hunter L, a, b and ${\Delta}E$. The most effective pretreatment to inhibit browning of yam slices was immersion In the solution containing 500 ppm of citric acid and 1000 ppm of cysteine for 1 min.

  • PDF

Pulmonary function is related to basic physical fitness and physical activity in college students (대학생의 폐활량에 대한 기초체력과 신체활동량의 관계)

  • Bae, Ju Yong;Park, Kyung Jin;Kim, Ji Young;Lee, Yul-Hyo;Kim, Ji-Sun;Ha, Min-Seong;Roh, Hee-Tae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.4
    • /
    • pp.1165-1175
    • /
    • 2021
  • The purpose of this study was to analyze the correlation between pulmonary function, basic physical fitness (PF), and physical activity (PA), and to compare the differences by gender in Korean college students. Measurements of body composition, basic PF, PA (questionnaire), and pulmonary function tests of forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) using a Quark pulmonary function test were carried out on 312 healthy participants (150 males [mean age: 19.29±1.72 years] and 162 females [mean age: 19.05±1.17 years]). The pulmonary function of male students was related to right-handedness, left-handedness, and back strength, and the pulmonary function of female students was related to all basic PF. The pulmonary function of male students was related to all PA variables, whereas the pulmonary function of female students was related to middle-intensity PA. The findings of this study suggest that male students need to increase PA, and female students need to improve basic PF to sustain a healthy pulmonary function. Understand gender differences for pulmonary function-related factors and the gender-specific educational efforts are needed to improve and maintain pulmonary capacity in college students.

The Effect of Speed-Change Gait Training on Cardiopulmonary Function of Stroke Patients (속도변화 보행 훈련이 만성 뇌졸중 환자의 심폐기능에 미치는 영향)

  • Seo, Dong-Yel;Yang, Yong-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.303-309
    • /
    • 2021
  • This study examined the changes in the cardiopulmonary functions of stroke patients by adjusting the s heart rate during walking training. This study was conducted on 20 chronic stroke patients. The experimental group conducted walking training by varying the walking speed according to the change in heart rate on the treadmill. In contrast, the control group conducted walking training by the subjective speed of the subject. The walking training was conducted for 32 minutes, three times a week, for a total of six weeks. The changes after the intervention of the subjects were determined by measuring the VC, ERV, IRV, FVC, FEV1, and PEF. The study revealed interactions between the groups and timing in the VC, ERV, and IRV(p<.05). There were no interactions between the groups and timing in FEV1, FVC, and PEF. The main effects showed no significant differences between the groups (p>.05) but showed significant differences between periods (p<.05). These results suggest that the cardiopulmonary function was improved significantly when the training was conducted by changing the pace of the heart rate in the walking process, leading to significant changes in the cardiopulmonary function.

Determining the residual surfactants in the fruits and vegetable washed with detergent (세척제를 사용한 과일 및 채소의 세척단계별 계면활성제 잔류량)

  • Lee, So Jeong;Park, Na-Youn;Kho, Young Lim;Kim, Jung Hoan
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.6
    • /
    • pp.792-798
    • /
    • 2021
  • This study was conducted to determine the washing conditions in which surfactants were not detected after washing fruits and vegetables with detergent. Residual surfactants were analyzed using LC-MS/MS. The analyzed surfactants were LAS, SLES, AOS, SLS, CAPB, and LDAO. The survey found that 14% of the respondents used detergent correctly according to the directions indicated. After soaking the samples with 0.2% detergent, the average residual surfactant content was 2.61%. Soaking under 1% and 5% of the detergent, 4.68-5.50% of surfactant remained in the sample. In cherry tomatoes, the surfactants were below the LOD after rinsing twice. However, lettuce was rinsed three times. These results suggest that when using detergent for washing fruits and vegetables, following the labelled usage and rinsing at least three times in 30 seconds could minimize residual surfactants.

Effect of Aluminum Chloride Hemostatic Agent on Bonding Strength of RMGIC in Primary Tooth (염화알루미늄 지혈제가 유치와 레진강화형 글라스아이오노머 시멘트의 결합강도에 미치는 영향)

  • Woo, Seung-Hee;Shin, Jisun;Lee, Joonhaeng;Han, Miran;Kim, Jong Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.397-404
    • /
    • 2021
  • The purpose of this study was to evaluate the effect of a hemostatic agent containing aluminum chloride on the shear bond strength of resin-modified glass ionomer cement (RMGIC) to the dentin of primary teeth. Thirty-six extracted non-carious human primary teeth were collected in this study. Dentin surfaces were cut and polished. The specimens were randomly divided into 4 groups; group I: RMGIC without conditioning; group II: polyacrylic acid (PAA), RMGIC; group III: aluminum chloride, RMGIC; group IV: aluminum chloride, PAA, RMGIC. All teeth were thermocycled between 5.0℃ and 55.0℃ for 5000 cycles. Fifteen specimens from each group were subjected to shear bond strength test and 3 specimens from each group were inspected using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy. The mean shear bond strength of each group was as follows: 4.04 ± 0.88 MPa in group I, 8.29 ± 1.40 MPa in group II, 1.39 ± 0.47 MPa in group III, 6.24 ± 2.76 MPa in group IV. There were significant differences among all groups (p < 0.001). SEM image of the dentinal tubules were partially exposed in group III and group IV. Fully exposed dentinal tubules were found in group II. In conclusion, aluminum chloride decreased the shear bond strength of RMGIC to dentin, regardless of PAA conditioning.

Physical and Mechanical Properties of Phyllostachys pubescens Treated with Hot Water and Microwave Irradiation (열수 및 마이크로웨이브처리 맹종죽재의 물리적·기계적 특성)

  • Shin, Hoon-Jae;Ahn, Sang-Yeol;Byeon, Hee-Seop;Park, Sang-Bum;Kong, Young-To
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.40-49
    • /
    • 2004
  • Phyllostachys pubescens planted in the Nambu Forest Experiment station in Jinju city of Gyongnam province was used, to investigate the physical and mechanical property of bamboo in this study. The ages of the P. pubescens were 1, 2 and 3 years, respectively. This experiment was carried out in August and January. The P. pubescens were divided into upper, middle and lower parts according to the growing points. The physical and mechanical properties of the P. pubescens were investigated before and after treatment of hot water and microwave irradiation. 1. The upper part of the P. pubescens indicated the highest static MOE according to the growing points. The range of the static MOE was from 70,000 to 110,000kgf/cm2. 2. When P. pubescens were treated with hot water of 95℃, the ratio of softening was about 10~30%. 3. As microwave irradiation time was increased, the MOE values was decreased in both green and water-saturated bamboos. For the irradiation time of 20 and 30 seconds, the static MOE of P. pubescens was decreased up to about 50% comparing with non-treated.

Effect of convergence body stabilization exercise on the visual response speed and functional movement, balance, and vital capacity of High School Football Players. (융복합적 신체안정화운동이 고등학교 축구선수의 시각반응속도와 기능적 움직임, 균형 및 폐활량에 미치는 영향)

  • Seo, Yeon-Soon;Song, In-Young;Yoon, Jong-Hyuk
    • Journal of Digital Convergence
    • /
    • v.20 no.1
    • /
    • pp.191-202
    • /
    • 2022
  • The purpose of this study is to examine the effect of a 10-week body stability exercise program, which was conducted on 24 male football players. The result of the Visual Response Speed Test using BlazePod, showed a significant increase of the upper arms, left foot and right foot for 15 second in number of reactions and reaction time (p<0.001). As a result of evaluating whether or not 7 functional movements were improved in order to evaluate the functional movement screen, Hurdle Step (p=0.001) and Active Straight Leg Rise (p=0.022) movements were significantly improved. significantly improved. As a result of measuring the y-balance Test in order to evaluate the balance ability, composite score(p<0.001) of both sides was significantly improved. The result of evaluating vital capacity, which was conducted to evaluate mobility and muscle endurance, showed a significant improvement in Forced vital capacity(p<0.001) and Forced expiratory volume in 1.0(p=0.003). In conclusion, a 10-week BSE program intervention in high school period, which can most improve the technical fitness necessary for the game in power, agility, leg strength, leg stability, mobility, and muscle endurance, will improve overall technical fitness, prevent football players from being injured and enhance their performance.

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF